Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.2 LAccepted-AOC | 1 | Accepted-AOC AGREEMENT EXECUTED | |
| 2 | 2₹3.3 L+₹10,048 (3.13%)Rejected-Finance | 2 | Rejected-Finance REJECTED |
Tender Value
₹3.3 L
EMD Value
₹8,300
Closing Date
28 Dec 2022, 5:00 pmClosed
AMBILI.T.A ,The Executive engineer
Kochi Municipal Corporation, Park Avenue Ernakulam, Kochi 682011
(S 961/23) Electrification of Vanitha Swayam Thozhil Pariseelana Kendram DIV 41 (Computer plug points at second floor) under Kochi Municipal Corporation General Electrical Work
2022_LSGD_539765_62
KMC CCPC4/44073/22 dtd 14/12/2022
Open Tender
Electrical Works
Item Rate
120 days
Ernakulam
Please refer Tender documents.
8 documents required · 8 mandatory
₹830
₹8,300
20 May 2023
20 Dec 2022
29 Dec 2022
20 Dec 2022
28 Dec 2022
20 Dec 2022
Amount
Part I- Electrification (Materials used for the work shall be as per the List of materials approved by the CCTCE
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD276151/2022-2023:Supply Conveyance, installation, testing and commissioning of 20 w out door light fittings ( Crompton make /Equilent Philips/Havells make ) on existing GI pipe and giving connection with 16/0.20 mm 3 core PVC insulated copper conductor cable
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD275785/2022-2023:Earthing with G.I. earth plate 600mm X600 mm X 6 mm thick with watering pipe 1.7 metre long and test joint using 2 nos 25x3mm GI Strip with sufficient drilled holes minimum size 25 cm suitably shaped and tightly clamped to the watering pipe using 25x6 mm steel bolts nut and washer and providing 2 nos, 20x3 mm GI strip from test joint to earth plate bottom level clamped at 2 locations on the plate and on the test joint bolted with steel bolts,nuts etc ,providing GI funnel welded with the watering pipe and making masonry chamber built with bricks and duly plasterd and providing cast iron cover plate etc complete
OD275801/2022-2023:Supply and installation of 16 Port 10/100 /1000 Mbps rack mountable switch Make: tp -link TL-SG 1016 D
OD275802/2022-2023:Supply and fixing of 19", 4U, 500 MM Depth Wall Mount Rack with Front Glass door, cooling fan 90cm ,NVRS, 1 No Power Distribution Unit Rack mounting type - 1 no, Cable Organizer /1U/Loop - 1No.(Netrack or equivelent make)-
OD275803/2022-2023:Supply and fixing 2 module moulded plastic box/metal box on surface/recess, fixing moduler face plate with RJ 45 CAT 6 jack(Legrand/AMP/MK) make
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.53.2:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
OD275836/2022-2023:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,residual current circuit breaker (RCCB), having a sensitivity current up to 30/100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD275918/2022-2023:Supply & fitting camera weather proof housing in position as required for outside camera.
OD275919/2022-2023:Supply & crimping RJ 45 Jack connector in position as required.
OD275920/2022-2023:supply & fixing camera PVC fixing box in position as required.
OD275921/2022-2023:Supply & fixing surveillance hard disk 4000 GB in position as required.
OD275922/2022-2023:supply & fixing HIKVISION 16 port GIGA POE switch (DS-3E0518P--E/M) in position as required.
OD275923/2022-2023:supply &fixing TV wall mounting rack in position as required.
OD275924/2022-2023:supply & fitting LED HDMI Monitor in position.
OD275925/2022-2023:HIKVISION 16 CHANNEL NVR,2 SATA (up to 4 TB each) incoming band width,160mbps. outgoing band width.100mbps, recording resolution.5MP/3MP/108p/UXGA/720p/VG/4CIF/DCIF/2CIF/QCIF, Frame rate. Mainstream.50fps(P) /60fps(N)sub stream.50fps(P)/60fps(N)HDMI and VGA outputs at up to 1920x1080 resolution.
OD275926/2022-2023:Supply and fixing HIKVISION 4 Megapixel digital IP full HD with 4mm fixed lens, true WDR, HLCBLC, IR bullet night vision network camera.
OD275927/2022-2023:Supply & fitting HDMI cord in position as required.
OD275964/2022-2023:HYKON make BIS Certified 2KVA/48VDC True Online Double Conversion IGBT Based Pure Sine Wave Online UPS with Hykon make 4 Nos of 12V/100AH Tubular Battery with Battery rack and Accessories including installation and testing
OD276077/2022-2023:Supply and providing FTTH data connection with TV channel support with accessries on suitale location including all payment to be paid to service provider and data cable laying through existing PVC conduit upto accessable service point of service provider
AJITH
Bidder Name
CHANDRAMOHANAN
AJITH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .