Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC | L1 | Accepted-AOC valid | |
| 2 | L2₹1.7 L+₹294.24 (0.17%)Rejected-AOC | L2 | Rejected-AOC reject |
Tender Value
₹1.7 L
EMD Value
₹4,326
Closing Date
14 Dec 2022, 4:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
ASSISTANT EXECUTIVE ENGINEER O/o AEE PWD ELECTRICAL SUB DIVISION KOLLAM
Civil Station Kollam Supply and installation of inverter at Collector 39 s chamber
2022_PWD_537452_1
PWD/BLDG/TR/15013/2022
Open Tender
Electrical Works
Item Rate
30 days
Kollam
Please refer tender documents
9 documents required · 9 mandatory
₹555
₹4,326
24 Jan 2023
8 Dec 2022
17 Dec 2022
8 Dec 2022
14 Dec 2022
8 Dec 2022
Amount
Supply and installation of Inverter
OD110461/2022-2023:Supply and installation of 1kVA online UPS. BIS Certified 1kVA/36VDC Pure Sine Wave online UPS, DSP and Dual microprocessor controlled system, Capacity-1kVA With Isolation Transformer, Single Phase Input Single Phase output and Earth, Input power factor=0 .9, Input current Distortion, I-THD-<=5%, Nominal output voltage=230 V AC Single phase, Output voltage regulation- +/-1%, efficiency - >90%, Ventilzation=Forced Air cooled, LED Display for Mains on, Inverter on, Battery Low, Over Load,Trip , Common Alarm, - Battery low Pre-alarm, Trip, Output short circuit protection, Output over/under voltage, Battery over temperature alarm, Battery 12V/65Ah CPRI Certified Tubular Battery 3 Nos with battery stand. Mandatory Certification-ISO9001-2015, ISO14001 -2015, OHSAS 18001 : 2007, CE Certification AND BIS Certification, CPRI Certification for batteries.
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
JEBIN JOHN MG POWER CONTROLS
Bidder Name
K J JOSEPH AND SONS ELECTRICAL CONTRACTORS AND ENGINEERS
JEBIN JOHN MG POWER CONTROLS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_781569.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .