Loading…
Loading…
Tender Value
₹56.9 Cr
EMD Value
₹1.1 Cr
Closing Date
30 Jun 2026, 12:00 pmClosed
Construction of Platform & platform shelter , Dismantling and relocation of existing Buildings/ structures, shifting of utilities, development of circulating area & other allied works including Electrification & Telecommunication works in connection with Re-development of Jajpur -Keonjhar road Station.
ETCECONIIIBBS2026021~ECOR
ETCECONIIIBBS2026021
Open
Works - General
18 Months
Jajapur, Odisha
₹0
₹1.1 Cr
29 May 2026
29 May 2026
16 Jun 2026
A- Station Building,FOB,Road,Circulating Area Etc(DSR-23 items) 313190609.76 Below/P
B- Structural Steel (FOB) (DSR-23 items) 83867781.60 Below/P
C-Ancilliary Works (Non - DSR items) 3893155.78 Below/P
D-Supply of Steel Reinforcement(DSR-23 items) 34988804.85 Below/P
E-Landscaping Work ( DSR-20 items) 1039823.85 Below/P
F-Unforseen works as per DSR-23 items 1000000.00 Below/P
G-Unforeseen works as per DSR-20 (Landscaping) items 100000.00 Below/P
J- Telecommunication Works (Supply of Telecom Materials ) 11869445.54 Below/P
H2-Electrification of PF shelter 23122394.60 Below/P
H3-Electrification of station building. 10031689.40 Below/P
H4-Electrification of circulating area. 9087447.67 Below/P
H5-Power supply arrangement for major upgradation 17513861.87 Below/P
H6-Provision of Lifts, Escalators and other misc works 33322304.41 Below/P
H7- Provision of DG set & Solar Plant 16484498.00 Below/P
Item Breakup - A- Station Building,FOB,Road,Circulating Area Etc(DSR-23 items)
Item Breakup - B- Structural Steel (FOB) (DSR-23 items)
Item Breakup - C-Ancilliary Works (Non - DSR items)
Soil architectural plans, elevations, structural designs, drawings including proof check etc. ECOR-CONST-HQ-ENGG/ECOR
Hiring of Telescopic all terrain Hour Hydraulic mobile Crane Main boom 52 mitis length Road Crane of 300/330 pacity DEMAG HC 810 model including necessary, oil, and operating staff including helpers, supervisors etc. with contractors own diesel, lubricants, other consumables, tools. spares, with all lead, lift complete as directed by engineer-in- charge. The contractor shall be responsible for arranging all types of permits, taxes, required for movement of the crane, Truck for assembling and dismantling of booms or internal shifting, arrange for necessary ground preparation for placing of crane at the work site. Payment shall be made for actual working hours at site. (For further any conditions are will not accepted by the Railway).
Mobilization Telescopic crane 300/330 Telescopic all Terrain mobile Crane model- DEMAG HC-810 with 52 mtrs Main Boom by contractor with required, fuel, spares, labour, tools and equipments etc., including all taxes, octroi, all complete. (For further any conditions are will not accepted by the Railway). Telescopic crane 300/330 (From Jagat pur (CTC)NH-16 to BHC Rly Stn (PF-1 to PF-4) side 100 km by Road).
De-Mobilization charges for the Each Telescopic crane 300/330 Telescopic all Terrain mobile Crane model- DEMAG HC-810 with 52 mtrs Main Boom by contractor with required, fuel, spares, labour, tools and equipments etc., including all taxes, octroi, all complete. (For further any conditions are will not accepted by the Railway). Telescopic crane 300/330 (From BHC Railway station to Jagat pur (CTC)NH-16) 100 km by Road).
Hiring of Hydraulic Excavator (3D) Day with driver and fuel for dismantaling structures alongwith levelling and dressing of ground with all contractor's machinaries, operator & fuel etc. Payment shall be made for actual working hours at site ECOR-CONST-HQ-ENGG/ECOR
"Metallizing of steel work of girders Sqm with sprayed aluminium after surface preparation by Sand/grit blasting, followed by one coat of etch primer (IS:5666) & one coat of Zinc Chrome primer (IS:104) and two coats of aluminium paint (IS:2339) with all labour, T&P and material as a complete job duly conforming to all relevant specifications and process given under Clause 39 of IRS-B1- 2001. Note: Nominal Thickness of sprayed Aluminium coating shall be 150 microns. DFT of Zinc chrome primer shall be 25-30 microns and DFT of each coat of Aluminium paint shall be 12-14 microns. On new girder during fabrication" Total 3893155.78
Item Breakup - D-Supply of Steel Reinforcement(DSR-23 items)
Item Breakup - E-Landscaping Work ( DSR-20 items)
Item Breakup - I-Telecommunication Works
"Excavation of trenches of depth Kilometre 0.8Meter and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, ramming, consolidation of soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found."
Excavation of trenches in all kinds of Metre soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including transportation and laying of DWC/RCC/Split RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Contractor. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All materials including cement are to be supplied by the contractor.
Laying of Signalling/4 Quad/ 6 Quad/ Kilometre Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables to work site and transportation of empty cable drums with left over cables from site to the stores. The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer. ECOR-CONST-HQ-ENGG/ECOR
Horizontal boring of dia.120 mm Metre under Railway Track/Road/ Culvert etc. laying of cables at a minimum depth of 1.4 meter extending up to 2.5 meter from formation level (Level of Earth below Ballast) as per drawing and directed by trenchless technology including the cost of self lubricated HDPE pipe of 120 mm. The bore should be capable enough for insertion of 120 mm dia DWC pipes. (a) The Cost shall includes horizontal boring through any intermediate obstruction either natural of man made or any boundary strata. (b) The rate is inclusive of all materials, equipment's and labour required for doing trenchless horizontal boring under the railway track. To this extra shall be admissible on any account than the rates as per above. (c) The pipes are to be laid under railway track/road/ culvert. All necessary arrangements are to be provided and all precautions are to be taken so that bore coming out at other end is not deviated from the horizontal level line by more than 250 mm horizontal or vertical location.(d) The rates shall be inclusive of detection and protection of underground utilities encountered during boring.
"Supply, Installation of earth electrode (make TATA or Jindal as per Rly. practice) including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rcak, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post & other equipments as per instruction on earthing of S&T equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat (make TATA/Jindal or Similar) to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK/13/85 Alt. A) NOTE: This includes testing of earth value and indicating the same on the Earth enclosure by paint." ECOR-CONST-HQ-ENGG/ECOR
Cutting of Trench across / on Metre Platforms with refilling and repairing the platforms for concealed wiring for a depth of about 25cm and width 10cm with marble cutting machine and filling the trench after cable laying and restoring the surface/trenching in non concrete area to depth of one meter. Refilling after cable laying and restoration the surface to normal condition etc. as per Technical instruction given in Chapter-III para no. 1.1.3.
Laying cable/PA Cable/ Data cable and all other types of telecom cable through HDPE pipe/casing capping/ false ceiling with laying/fixing of HDPE pipe/casing capping/PVC pipe for connecting/interfacing various components and system integration. All materials for jointing and termination of power/CAT-6 cable as per site requirement are to be supplied by contractor. this item also includes supply of RJ-45 connector with cap for terminating CAT-6 cable and (This incudes releasing of existing cables, display boards if any as per the instruction of Rly. representative at site).
Supply and installation of on-line Numbers interactive 5kva UPS with battery, having battery back up of 120 minutes at rated load, make: APC/Unline/Amararaja. Inspection by the Representative of Railway.
Installation, commissioning of CDC set as per RDSO Specification No.RDSO/ SPN/TC/108/2019 Ver.0.0 Amdt 1 with Set latest amendments, Versions.
Supply, installation, testing and Numbers commissioning of Train formation At A Glance display board with all accessories as per RDSON specification no.RDSO/ SPN/TC/108/2019 Rev.0.0 with Amdt - 1 or latest. Inspection by the Representative of Railway. Inspection by the Representative of Railway.
Installation, commissioning of PDC as per RDSO 11 Specification No.RDSO/SPN/TC/ 108/2019 Ver.0.0 with Amdt 1 Nos. or latest as supplied.
Installation, Commissioning of Double Faced Coach Guidance Display Boards and daisy chain junction box in Open 12 area including supply, erection & fabrication of pole, angles, Nos fastening & rain-hood as per Technical instruction given in Chapter-III para . 1.1.1 ECOR-CONST-HQ-ENGG/ECOR
Installation, Commissioning of Coach Guidance Display Board and Daisy Chain Junction Box in covered area. All fixtures required for this purpose will be arranged by the contractor at his own cost as per Technical instruction given in Chapter-III para no. 1.1 1.
Installation and commissioning of Numbers Multi line Train Indication Boards cum video display LED Type single face with all necessary accessories and video display controller, LED type as per RDSO specification No. RDSO/SPN/TC/108/2019 Ver.0.0 Amdt 1 or latest.
Supply and installation of Audio Numbers Amplifier of Make- Ahuja model SSA- 350 or similar,workable on 230V AC / 12VDC supply with protection against wrong battery polarity connections in the control console, as directed at site. Inspection by the Representative of Railway.
"Supply, [Commissioning of GPS based double faced Digital platform clock as per RDSO Specification no. RDSO/ SPN/ITC/ 62/ 2008 Rev. 3.0 or latest. It also includes all fitting arrangements. Inspection by the RDSO"
Supply Communication system model no.CCS.-2300 (Ahuja make) or s i m i l a r . Inspection by the Representative of Railway.
Supply and installation[splicing of Numbers fiber] of Rack Mount LIU 12 Core Loaded with SC Adaptors. Make : D- Link or similar of reputed make. Inspection by the Representative of Railway.
Supply and installation of cablofil wire Metre mash cable tray as per detailed specifications. It should be of size 150 mm width and 54 mm depth Electro Galvanised type ( cat No. 000081 of legrand), fast couplers EDRN type (Legrand cat no. 558241) and Kitaster (Legrand cat no 558081) for Joining two length, round corners and centre joint, wall mounting type accessories in GS material CSN for running the cable tray along with the wall (legrand cat No.556110)and Faslock for roundcorners (cat no 558347 of legrand)and equipped with Cover (legrand cat No 646030) equal to the length of the Cable tray and fixing clips for the cover (cat no 646200) and RCSN 200 (legrand cat no 13200) support for vertical mounting. Inspection by RITES.
Supply, commissioning of 2core screened/shielded multi strand PVC insulated wire [24/0.2mm dia.] for speaker load line. ECOR-CONST-HQ-ENGG/ECOR
Fixing of aluminium/Krone type CT Numbers Boxes/rossetts and termination on following PIJF/U/G cable, SB cables in cable termination box including all other works required for cable termination. This includes plumbing of cable, painting, cementing &lettering of CT box.
Splicing of fibre.
Transportation of HDPE pipe from the Kilometre store of SSET/Stores/KUR to the work site, laying of the same ( with 4mm nylon rope,pre inserted inside the HDPE pipe) in excavated trench/already laid GI/RCC pipe/tubes,jointing, levelling and end sealing the pipes. HDPE pipe, couplers and end rope shall be supplied by the railways, Nylon rope shall be supplied by the contractor.
Transportation of OFC from the store Kilometre of to work site with care, and pushing/ pulling OFC through the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.
Supply, installation of RCC joint chamber with two piece top cover and bottom cover with hole for drainage and cable entry as per drawing No.RCIL/ER/DRG- 02/06 (Section-H). This includes trenching for joint pit, back filling and ramming of pit after placing the joint closure and cable loop in the chamber without causing damage to the same and consolidation of soilas well as disposal of excess soil.
Supply and installation of 19" rack Numbers mounted 24port LIU(FMS) with pigtail/couplers and all other accessories and termination/splicing of 24 fibre OFC cable in it as per sr. No. 14.0 of Technical Specification.Inspection by Consignee.
Supply ,transportation& installation of Numbers Optical Fibre cable joint enclosure and splicing of OFC (24 Fibre) and testing. OFC spicing shall be done in presence of Railway Representative.
Supply, transportation &installation of Numbers 2 KVA online UPSwith 120 Minutes back up time.
Supply and installation of Surface Pair Mount Speakers similar to Make EV Model EVID 4.2t as per specification ANNEXURE-KK or better. Inspection by RITES. (Unit: Pair = 2nos.) ECOR-CONST-HQ-ENGG/ECOR
Installation, Testing & Commissioning Numbers of 4K UHD Bullet Type IP Colour camera along with Mount. All the accessories and fixing materials including Mount required for this installation are to be supplied by contractor within the same cost.
Installation, Testing & Commissioning Numbers of Layer-2 PoE Switch (minimum 8+2 port manageable) with 8 nos 10/100/1000 Mbps Ethernet Port, POE & 2 Nos 1000 base X SM SFP Port with optical modules. All the accessories & fixing materials required for this installation are to be supplied by the contractor within the same cost.
Supply and Installation of Modular Numbers socket Box with one RJ-11 double Socket Box & two RJ45 socket complete with 3 module metal flush box and top plate with all required accessories It Shall comply to TEC GR No.TEC/GR/SLC - 01/02.AUG05 (TEC Standard Number: TEC52010:2005) with latest amendments ,Version. Inspection by Consignee.
Supply, placing and covering of RCC Running duct, 500 mm from Home to Home as Metre per RDSO drawing No.SDO/CABLE LAYING/ 007, Dt.31.10.2011. Inspection by representative of Railway.
Supply of HDPE pipe of 110 mmdia, Metre Pressure rating: PN 10,Material grade: PE 80 and wallthickness:10.0 to 11.1 mm,colour: Black with blue stripesconfirming to spec IS 4984:1995and latest. Coil length: 100 Mtrs.Inspection by RITES. Total 8247297.95
Item Breakup - J- Telecommunication Works (Supply of Telecom Materials )
Supply of Central Data Controller Unit Set conforming to system requirement as per RDSO specification no.RDSO /SPN /TC/108 /2019 Ver.0.0 Amdnt 1.0 with latest amendments, Versions. Thecontrol console shall havemain and standby CPU towork in standby mode, UPSof minimum 1 KVA withminimum 25 minutesbattery backup on 0.8 KVA shall be provided for uninterrupted operation of the CDC., LCD monitor, CCURack, KVM Switch,CDS(Layer3 Switch of make HP,CISCO, Juniper, Brocade,IBM, Alcatel, Lucent, Avaya,Netgear, D- link, Moxa, Phoenix Contact etc. orother similar make) andother accessories, housedin a standard size cabinet along with driving Software for integrated passenger information system as per RDSO Specification No RDSO/SPN/TC/108/2019 ver.0.0 amdt 1 or latest. This includes supply and installation of SW for Announcement system with necessary interface and announcement recording (Hindi/English/Local language) fresh studio copy of voice files.) as per RDSO Specification No.RDSO/ SPN/ TC/108/2019 Ver.0.0 amdt 1 or latest (the same to be interfaced with existing audio and video system installed at the station.) The software should support all types of display/ announcement by merely adding necessary hardware in future (single/ multiline) arrival/departture train information display boards. (singlesided/double sided) CGDB,AGDB, LCD/LED/PlasmaTVs etc.This IPIS Software shall be integrated with existing IPIS Software to fetch the train data. Inspection by RDSO.
Supply of Double Face Coach Numbers Guidance Display Board with accessories as per RDSO/SPN/TC/108/2019 Ver 0.0 Amdnt 1.0 with latest amendments, Versions. (Inspection by RDSO)
Supply of Multi line Train Indication Numbers Boards (6 linesTrue color) LED Type single face with all necessary accessories and video display controller (Alluminiumcabinet with Nichia LED asper RDSO specification No. RDSO/SPN/ TC/108/2019 Ver.0.0 Amdt 1 or latest. (Inspection by RDSO)
Supply of permanently lubricated two Kilometre layer type HDPE duct, outer dia 40 mm, inner dia 33 mm with three end plugs and two couplers for every Km length of pipe in length of 500 m confirming to RDSO Spec. No. RDSO/SN/ TC/45/2013 Rev.2.0 Ammendment 1.0 or latest. Note: The HDPE Duct should be pre inserted with 4 mm nylon rope, inside the HDPE Duct. (Inspection by representative of Railway) ECOR-CONST-HQ-ENGG/ECOR
Supply of Platform Data Controller Numbers (PDC) conforming to System requirement of RDSO Specification No. RDSO/SPN/TC/108/2019 Ver.0.0 Amdnt 1.0 with latest Amendments, Versions. (Inspection by RDSO)
Supply of PVC insulated flexible 3 Metre core x 2.5 sq.mm multi strand power cable as per specification no. IS:694:1990 reaffirmed 1995 or latest. (Inspection by representative of Railway)
Fiber splice closure box suitable for 6 Numbers fiber. (Inspection by representative of Railway)
Supply of UTP CAT 6 Cable (Roll305 Metre Mtr).Make DLink, Amp or Molex. (Inspection by representative of Railway)
Supply of rack (9U) with all Numbers accessories. Make:Valrack/HCL/ Hunt/ Rontel/D-link. (Inspection by representative of Railway)
Supply of PVC pipes conduits of Metre nominal size 25mm. Outer dia25mm inner dia 22.1 mm approx.Color gray/black/white, ISI marked. (Inspection by representative of Railway)
Supply of OFC single mode 6fiber Metre armoured cable of makefinolex/Polycab/Paramount. (Inspection by representative of Railway)
"Supply of double walled corrugated Numbers pipe 6 mtr in length, 120 mm outer dia and 103 mm inner dia, with one suitable coupler conforming to RDSO Specification No. RDSO/SPN/204/2011 Version 1.1 Amdt 1 or latest for under ground cable protection . Colour- Orange. Inspection by the Representative of Railway. Note: If required, the DWC pipe shall be supplied split in two halves."
Supply of public address amplifier Numbers solid state of capacity 500 watts (RMS) output The amplifier shall be of type SSA 5000 EM of Ahuja make or Shure OR Bosch OR Studio Master OR Ahuja or Philips or latest version. Details conforming to clause No 4.6 of Part IV in the tender document. (Inspection by representative of Railway)
Supply of optical fibre joint closure for Numbers straight through joint with modification for 24 fibre as per RDSO Specn No. RDSO/SPN/TC/68/2014, Revision 0.1 Amnd. 1 or latest. Inspection by the Representative of Railway.
Supply of Thermo shrink jointing kit Numbers for underground cable as per Specn No. IRS: TC-77/2012 [Rev.3] Amd 3. (Cable jointing kit shall be procured from RDSO approved sources only). (Inspection by RDSO) ECOR-CONST-HQ-ENGG/ECOR
Supply of Ceiling Mount Access Point Numbers with 802.11ac standard, 1200Mbps, WAN/PoE: 1x 10/100/1000Mbps 802.3at/af PoE Port, LAN: 1x10/100/1000Mbps, Antenna: 5dBi,Multiple Operational Modes, Multiple SSID Support (Upto 4 SSIDs per frequency band). WiFi Transmit Power : Up to 27dBm, Make Digisol,D- link, Cisco or similar. (Inspection by representative of Railway)
Supply of 20 pair Aluminium CT box Numbers to spec No- IRS:TC 18/75. Inspection by the Representative of Railway.
Supply of Krone type fiber box indoor Numbers surface installation complete with module and locks suitable for 20 pair. Inspection by the Representative of Railway.
Supply of GPS based-digital clock Numbers office type as per RDSO specification no.-RDSO/SPN/TC/47/2008 rev 3.0 or latest make/brand- Autolite or Similar as per TS. (Inspection by representative of Railway)
Supply of Switch Board 10p/0.5mm. Inspection by Representative of Railway.
Supply of 19" 12U rack. Inspection By Numbers Representative of Railway.
Supply and Installation of Smart Numbers Television Tv 65 Inch LED as per technical specification attached. Inspection by representative of Railway.
Supply of Perforated G.I. pipe of 100 Metre mm dia with socket. G.I. pipe of make TATA/JINDAL shall be as per IS: 1239 part-I/2004 Specification for medium gauge and shall be perforated by drilling 7 mm dia holes length wise in zig-zag manner staggered at a distance of 300 mm. Inspection by representative of Railway.
Supply Polythene sheathed armoured Jelly filled Telephone cable with Poly-AL moisture barrier 0.63 mm dia, 20 pair to specification No. IRS:TC-41-97 with latest amendment. Inspection by representative of Railway.
Supply of Polythenes insulated, Kilometre polythene sheathed, jelly flled telecommunicaton cables having annealed copper conductors polythene insulated colour coded cores twisted into pairs laid up and fully flled with petroleum jely, taped cable applied with poly aluminium laminated moiture barrier, polythene sheathed and double steel taped armoured and jacketed cable conforming to Spec.No.IRS:TC41/97 with amendment No.1 or latest 50 pair x 0.63 mm dia. Drum Size 500 meters. ( Warranty Period : Upto 30 months from the date of supply) Inspection by representative of Railway. ECOR-CONST-HQ-ENGG/ECOR
Supply of UNDERGROUND RAILWAY Kilometre JELLY FILLED 06 QUAD CABLE 0.9 mm DIA AS PER IRS SPECIFICATION No IRS:TC 30/2005 (Ver-1) (Amd 1 to 5) OR LATEST, IF ANY. Make Brand:SRIRAM or Similar. ( Warranty Period : Upto 30 months from the date of supply) Inspection by Representative of Railway.
SUPPLY OF MONOMODE OPTIC FIBER Kilometre CABLE ARMOURED 24 FIBER AS PER RDSO SPECIFICATION No IRS:TC:55/2006 [Rev-1] WITH AMENDMENT No 3 OR LATEST, IF ANY. Make/Brand: PCL OR SIMILAR ( Warranty Period : Upto 30 months from the date of supply). Inspection by Representative of Railway.
Supply of 24 port VDSL2 IPDSLAM Numbers system with Expandability; 2U, Temperature- Hardened, 5-Slot Chasis, MSAN AC Power Module & Fan Module- (01 No.) with Management Card with 2GbE combo ports (2 SFP and 2 1000BASE-T), (SIP-01 No.) and 24 port VDSL Line Card, with built-in- Splitter - 01 No. with Telco 64 to open ended Cable- 02 Nos. Make- ZYXEL or similar. Accepted firms offer Description/Make/Brand-Zyxel IES- 4105M + MSC1002G + VLC1124A-51 + Telco64 Cable, [ 24 Port VDSL2 IPDSLAM System with: 2U Temperature-Hardened 5-Slot Chassis MSAN AC Power Module & Fan Module (1 No) with Management card with 2 GbE combo ports (2 SFP and 2 1000BASE-T) (SIP) (1 No) and 24-Port VDSL Line Card. Inspection by representative of Railway.
Supply, testing of VDSL Modem with Numbers all accessories (Power Adapter, Spliter, Line Cord etc) Make: Zyxel, VMG1312 or Similar Inspection by representative of Railway.
Supply of 30Mbps LAN Extender Pair supporting short & longer distance ( up to 10km or more) dual power supply AC/DC from a single socket plug in module in the stand alone unit to be accommodate in central rack multi ware 16. Make-MROTEK model- WL-LG or similar. Inspection by representative of Railway.
Supply of MODEM PAIRS V.35 AND Pair G.703 2MBPS AND 2WIRE LEASED LINE 2 MBPS (NX64 KBPS) MAKE: TEAM ENGINEER 4 TIRE OR SIMILAR. RDSO SPECIFICATION NO. - RDSO/SPN/TC/80/2020 Revision 2.0 Firm's offered make-'Nomus Gateway e/2M/2W/G.703/V.35.' ( Warranty Period : Upto 30 months from the date of supply) Inspection by representative of Railway.
Supply of 3 KVA/12960 VAH without Numbers trolley & with battery Sine Wave Inverter of Make: LUMINOUS or similar. Inspection by representative of Railway. ECOR-CONST-HQ-ENGG/ECOR
Supply of 12V,100AH SMF battery of Numbers make OKAYA, Exide, Amron or similar. Inspection by representative of Railway.
Supply of 4K UHD Bullet Type IP Numbers Colour camera (Type-A) as per RDSO spec. No: RDSO/SPN/TC/65/2021 Rev.6.0 or latest Clause no.5.5. Inspection by RDSO.
Supply of Industrial grade operator Numbers VDU of size 55" full HD 4K, HDMI/DVI connectivity, Inbuilt speaker etc of suitable to existing EI system for 24*7 application. Accepted Make/Brand- Samsung/LG/Sony/Panasonic ( LH- 55AN6ND). Warranty period upto 30 months from the date of supply. Inspection by representative of Railway.
Supply of industrial grade fanless Numbers embedded processor unit with good quality keyboard and mouseas per specification, Make/Model-Moxa V2406A or Vecow ECS9210M or Advantech or similar. Inspection by representative of Railway.
Supply of Layer-2 PoE Switch Numbers (minimum 8+2 port manageable) with 8 nos. 10/100/1000 Mbps Ethernet port, PoE and 2 nos. 1000 Mbps SFP port with optical modules complete with all accessories etc. as per RDSO spec. No: RDSO/SPN/TC/65/2021 Rev.6.0 or latest, Clause no. 14.0(III). Inspection by RDSO
Supply and Transportation of 6 TB Numbers Surveillance HDD, Make SEAGATE/WD or similar. Inspection by representative of Railway.
Supply of 32 channel NVR as per Numbers specs No. 10.2 of RDSO specs No. RDSO/SPN/TC/65 /2021 Version:6 or latest including 1 TB Surveillance HDD. Firm's Offer Make- CP PLUS ( Warranty Period : Upto 30 months from the date of supply) Inspection by RDSO. Total 11869445.54
Item Breakup - H1-Electrification of 12 m FOB
Supply of 20W LED batten
Fixing, testing and commissioning of Numbers light fitting, ceiling fan and exhaust fan
Surface wiring of light/ fan/ signage Point point with copper wire
Supply, commissioning of 6-way distribution box (acrylic window) with I/C:1x32A MCB DP, 10KA C curve, O/G:4x6A/10A/16A MCB SP 10KA C curve ECOR-CONST-HQ-ENGG/ECOR
Supply aluminium cable of size 4 C x 16 sq.mm having heat resisting insulation
Supply of GI Cable Tray and laying of Metre cable through cable tray
Single Cable road/track
Single Cable laying in air
Provision chemical earthing Total 1141231.22
Item Breakup - H2-Electrification of PF shelter
Supply of 20W LED batten
Supply of BLDC energy ceiling fan 1200 mm sweep
Design, manufacture, supply of LED Square signage Foot
Fixing, testing and commissioning of Square LED signage Foot
Surface wiring of light/ fan/ signage Point point with copper wire
Supply of materials and surface Metre wiring of mains with 2 x 6 sq.mm + 1 x 2.5 sqmm copper wire
Supply of materials and surface Metre wiring of sub-main with 2 x 4 sq.mm + 1 x 2.5 sqmm copper wire BDB to individual switch board in PVC conduit
Modular type concealed wiring of 6A Numbers socket point on separate board with 2.5 sq.mm copper conductor inside PVC conduit
Modular type concealed wiring of 16A Point socket point on separate board with 4 sq.mm copper conductor inside PVC conduit
Supply and erection of loop-in/ loop- Numbers out Junction Box made up of moulded FRP, outdoor type, weather proof confirming to IP55/65
Supply, commissioning of 4-way DB
Supply, commissioning of Power Junction box fitted with 4 No. bus bar type terminal blocks with accessories
Supply aluminium cable of size 4 C x 25 sq.mm having heat resisting insulation
Supply aluminium cable of size 4 C x 70 sq.mm having heat resisting insulation
Supply aluminium cable of size 4 C x 120 sq.mm having heat resisting insulation
Supply of GI Cable Tray and laying of Metre cable through cable tray ECOR-CONST-HQ-ENGG/ECOR
Single Cable road/track
Single Cable laying in air
Provision chemical earthing
Supply & erection of (50X6/25x6)mm Kg GI flat for earthing connection
"Supply, installation, testing and Metre commissioning of 4P+PE, 63A Copper lighting bus-duct trunking with plug in points at every 500 mm complete including straight feed, supports etc. "
Supply, installation, testing and Numbers commissioning of End Feed Unit (direct type) for 4P+PE, 63A copper lighting busduct
Supply, installation, testing and Numbers commissioning of flexible elbow for 4P+PE, 63A copper lighting busduct
Supply, installation, testing and Numbers commissioning of plug-in box direct type 6/ 10/ 16/ 25A for 4P+PE, 63A copper lighting busduct
Supply & testing of water cooler-cum- Numbers purifier of 120 ltr capacity
Supply commissioning of 125A pre-cooling/ battery charging socket with complete accessories
Supply & erection of 32A, 3-pin plug Numbers (3P +N+E) and socket with 40A, 4P, 10 kA, C-curve MCB
Dismantling of TFL/ CFL/ LED fittings Numbers and transportation of the same to Railway consignee's store
Dismantling of ceiling fans/exhaust Numbers fans and transportation of the same to Railway consignee's store
Dismantling of RSJ/ WPB/ SST/ Rail Numbers pole/ or any other outdoor/ indoor structure and transportation to Railway consignee's store
Dismantling of street light fitting and Numbers transportation of the same to Railway consignee's store.
Dismantling pillar/floor mounted/ wall mounted panel board and transportation of the same to Railway consignee's store Total 23122394.60
Item Breakup - H3-Electrification of station building.
Supply of 20W LED batten
Supply of BLDC energy efficient Numbers ceiling fan 1200 mm sweep.
Supply of LED down light fitting Per Unit complete with luminaire (Note: The unit is taken per Unit which means Watt)
Supply of LED swivelling type Per Unit spotlight fitting complete with luminaire (Note: The unit is taken per Unit which means Watt) ECOR-CONST-HQ-ENGG/ECOR
Supply of exhaust fan 300mm sweep Numbers single phase, 230 V, 50 Hz with bird screen
Supply of exhaust fan 200 mm sweep Numbers single phase, 230V, 50Hz with movable louvers
Supply of 5W LED mirror light
Supply of foot light with LED lamp Numbers complete:
Modular type concealed wiring of Point light/fan/call bell point with 1.5 sq.mm copper wire
Modular type concealed wiring of 6A Point socket point on separate board with 2.5 sq.mm copper conductor inside PVC conduit
Modular type concealed wiring of 16A Point socket point on separate board with 4 sq.mm copper conductor inside PVC conduit
Concealed wiring copper wire
Concealed sub-sub main wiring with 4 Metre sq.mm copper wire
Concealed wiring copper wire
Supply, installation of cassette type Numbers air conditioner 2 TR capacity
Supply of Split Air-Conditioner capacity 2 TR, Star rating- 5
Installation charge Conditioner
SETC of 20A AC Box with 16/32A SP Numbers MCB and 25A starter switch
Supply, commissioning of 4-way DB
Supply of 12 way double door DB with Numbers 01 No 40A TPN MCB,2 Nos 32A DP and 4 Nos 16A/25A/32A MCB
Supply and erection of VTPN DB with Numbers I/C: 1 No. 100A MCCB and O/G: 3 no. 63 A TP MCB, 3 No. SP MCB 16A/25A/32A
Supply of PVC insulated flexible Metre copper cable 4 core size 16 sq.mm, voltage rating up to 1100 V, confirming to IS 694:2010 or latest, 126 strand of 0.4 mm diameter, FRLSH, sheath type ST-3
Excavation of wall and fixing of cable Metre with cement plastering
Supply and erection of Electronics Numbers Door Bell.
Fixing, testing and commissioning of Numbers light fitting, ceiling fan and exhaust fan
Supply, commissioning of energy efficient electrical Geyser, 10 ltr capacity
Erection of LED down light fitting with Numbers all accessories including connection
Supply, installation, testing and Numbers commissioning of HVLS fan, Dia-8 feet, Air flow-136000 CFM, Blades- 5 No. ECOR-CONST-HQ-ENGG/ECOR
Supply and fixing of new energy- Numbers saving Occupancy Sensor (Motion and Light Sensors), Multifunction Sensor, Range 20m & above. Warranty-3- year, Detection Angle 360 Degree, Time Delay 10 sec to 30 min. Total 10031689.40
Item Breakup - H4-Electrification of circulating area.
Supply commissioning of 12-sided hot dip galvanized High Mast Tower of height 12m with all accessories
Construction of suitable foundation for high mast
Supply of 200W LED flood luminaries Numbers
Supply, commissioning of 9W LED integral decorative bollard with optical acrylic luminaire
Supply, commissioning of LED building contour lighting, IP 67 with aluminium channel and gripping
Supply, commissioning of LED facade light system
Supply luminaries of operating voltage range.90-260 volt, operating temperature range -10 degC to +50 degC, rated voltage - 240V AC, 50 HZ, system wattage-12W
Supply of 4- way linear warm white Numbers decorative fixture with IP-67 housing power output 5W
Supply of LED pendant luminaries of Numbers 20W narrow beam powder coated aluminium housing and pressure die- cast heat-sink having high efficiency colour temperature 3000 K
Supply, commissioning of 6 m high double- arm decorative GI/CI pole with cast aluminium arms including 2 no. 80W tear-drop LED fittings along with foundation as per manufacturer's design
Supply, commissioning of 6 m high single-arm decorative GI/CI pole with cast aluminum arm including 1 no. 80W tear-drop pendant LED fitting along with foundation as per manufacturer's design
Supply, commissioning of 3 m height decorative GI/CI pole with cast aluminum arm including 1 No. 60 watt LED post-top lantern along with foundation as per manufacturer's design
Supply and erection of 70W LED Numbers Highbay fitting complete ECOR-CONST-HQ-ENGG/ECOR
Surface wiring of light/ fan/ glow Point signage point with copper wire
Supply of materials and surface Metre wiring of main with 2(1x6 sqmm) + 1x(2.5 sqmm) copper wire
Supply of materials and surface Metre wiring of sub-main with 2(1x4 sqmm) + 1x(2.5 sqmm) copper wire BDB to individual switch board in PVC pipe
: Supply, erection, testing and Numbers commissioning of sub service main wall mounted consisting of 8-way SPN DB with 8x 6A/10A/20A/25A C curve SP MCB 10kA.
Supply of 12 way double door DB with Numbers 01 No 40A TPN MCB,2 Nos 32A DP and 4 Nos 16A/25A/32A MCB
Supply aluminium cable of size 4 C x 16 sq.mm having heat resisting insulation
Supply aluminium cable of size 4 C x 70 sq.mm having heat resisting insulation resisting insulation.
Single Cable road/track
Single Cable laying in air
Single Cable road/track
Dismantling of hard concrete in any cum shape and size and laying of cable
Provision chemical earthing
: Supply & laying of 6/8/12 SWG GI Kg steel wire Total 9087447.67
Item Breakup - H5-Power supply arrangement for major upgradation
Supply of 11/0.4 KV, 500 kVA oil type Set Packaged substation
Erection of substation
Supply commissioning of Outdoor 11KV, 630A, 21kA for 3 sec. motorized SCADA compatible non-extensible VVVV type 4-way RMU (1 I/C + 3 O/G VCBs)
"Supply, commissioning of main distribution panel including copper bus bar, incomer 2x 800A MDO type ACB and one 800A MDO type ACB as bus coupler. Outgoing 8 No. 250A MCCB and 2 No. 100A MCCB with all accessories "
: commissioning of floor mounted indoor LT panel (I/C: 1 no. 630A ACB and OG: 2X250A, 2X100A & 2X63A MCCB)
Supply of three core 11 KV screened Metre XLPE cable of size 3X185 sq mm ECOR-CONST-HQ-ENGG/ECOR
Supply of LT XLPE armoured cable of Metre size 1 C x 630 sq.mm size having heat resisting insulation
Supply aluminium cable of size 4 C x 120sq.mm having heat resisting insulation
Supply aluminium cable of size 4 C x 70sq.mm having heat resisting insulation
Single Cable road/track
Single Cable laying in air
Cable laying across the road/track by Metre using trenchless construction (HDD) method
Excavation of wall and fixing of cable Metre with cement plastering
Dismantling of hard concrete in any cum shape and size and laying of cable
Supply, commissioning of outdoor type distribution feeder pillar box consisting of copper bus bar 200Amp, I/C: 1X200A MCCB 4P, 35kA, O/G: 4X63A MCCB FP, 25kA, 2X32A MCB TPN 10kA, C curve
Provision chemical earthing
Supply & erection of G.I. 50X6/25x6 Kg flat for connection earthing
Lumpsum enhancement and Additional SD towards payments to state power supply authority with other associated works. Total 17513861.87
Item Breakup - H6-Provision of Lifts, Escalators and other misc works
Supply, Installation, Commissioning Numbers and maintenance of electric operated machine room less and gearless type passenger lift/elevator for 20 persons (1360 kg)
Supply, Installation, Commissioning Numbers and Maintenance of electric operated machine room less and gearless type passenger lift/elevator for 13 passengers (884 kg)
Design, Installation, Testing and Commissioning of Escalators as per as per RDSO Specification
"Supply of 100W LED street light "
Erection of street light fitting on Numbers SST/Rail/GRP/GI octogonal pole
Supply of 9 m Long Hot Dip Numbers Galvanized Octagonal Pole with double arm, Foundation Type Base Plate & Foundation Bolts with accessories ECOR-CONST-HQ-ENGG/ECOR
Supply commissioning of external lightning protection system with complete accessories
Supply, commissioning of High Risk area SPD, 100 kA, 3P+N for main panel areas with box complete with all accessories
supply, commissioning of general purpose SPD, 50 kA, 3P+N , Class I (T1) for sub panel areas with box complete with all accessories Total 33322304.41
Item Breakup - H7- Provision of DG set & Solar Plant
Supply, Installation, Commissioning of Set DG set of capacity 250kva with complete
Design, manufacture & supply of Grid Per Unit connected Solar Photo voltaic (PV) Plant without battery backup complete.Capacity 250kWp. Note:- Per Unit to be read as "KWP" Total 16484498.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .