Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹40.3 L+₹59,023 (1.49%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹44.0 L+₹4.3 L (10.8%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
3 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-04/2023-24 PROVN OF CERTAIN WORK SERVICES AT OFFICERS MESS AND CERTAIN MINOR/REVENUE WORKS AT DIFFERENT LOCATIONS AT AF STN AMBALA UNDER GE (AF) AMBALA
2023_MES_594184_1
GE AF/AMB-T-04/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹92,000
Yes
22 Jun 2023
9 May 2023
5 Jun 2023
9 May 2023
3 Jun 2023
22 May 2023
10 May 2023 - 17 May 2023
Amount
Surface Excavation not exceeding 30 cm deep and averaging 15 cm deep wide and getting out soft/disintegrated soil complete all as specified and directed.
Excavation in post hole each not exceeding 0.5 cum getting out, returning filling and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm in soft / loose soil, complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and welol remming in layers not exceeding 25 cm complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation, filling and mass concrete complete all as specified and directed.
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F framed brackets of angles or Tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc not exceeding 10 kg each brackets, conforming Fe- 290. Gde -E-165 (brackets over 10 kg each to be measured under structural steel complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm but not exceeding 10cm long complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F 16mm thick, UV coated polycarbonate roofing sheet of any colour as in roof, fixed with all accessories, compete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic paint over a coat of red oxide primer over 10 cm width or girth not otherwise described etc, complete all as specified and directed.
Providing plain cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including neessary form work complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block rubber finish of any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment finished with coloured rubber finish on top, finished over sand dust cushion of 30mm thick, complete all as specified and directed.
S&F water saving long body bib tap 15mm dia, cast copper alloy, CP fancy type fixed including taking down of old unserviceable bib tap of any description and type complete all as specified and directed Make Jaquar Model No. CON-CHR-107PM/GA or equivalent in CERA/ JAINKO/SHAKTI/ PRAYAG ,
M&L Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as specified and directed.
All as per item No 16.00 (here-in-before) but 8mm dia ,cut to length, bent to shape required, including cranking, complete all as specified and directed.
M&L Hard core of, broken stone to gauge n exc 63 mm, deposited, spread and leveled in layer n. exc 15 cm thick complete all as specified and directed.
M&L for75mm thick PCC 1:4:8 type D-2 using 40mm mechanical crushed stone aggrgate as in floor, complete all as specified and directed.
M&L for100mm thick PCC 1:2:4 type B-2 using 40mm mechanical crushed stone aggrgate as in floor, complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm mechanically crushed stone aggregate as in coping , kerbs ,benching etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded aggregates) Concrete bed to100mm drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed.
M&L for 100mm dia RCC pipe class NP-2, laid in trenches and joints complete all as specified and directed.
Precast RCC, 1:2:4, type B-1 (using 20mm graded aggregates) set in cm 1:6 as in manhole covers, complete all as specified and directed.
S & F grease trap made of 2mm thick stainless steel (304 grade) of size 1500 x 600x 600mm having flow rate 400 lit/ min and volume 450 litres. Inlet and outlet shall be 100mm bore all as per manufracturer's instructions, complete all as specified and directed.
E/M Portion
M&L for point wiring with single core PVC insulated FRLS unsheathed, 1100 volt grade cable with multi strand copper conductor of size 2.5 Sq mm (Nominal area) drawn through and including non metallic concealed PVC conduit, medium grade, as directed/ ground requirement, ISI marked of suitable size, ceiling with GI screws, rawl plugs with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated or PVC Box of suitable size with 3 mm thick laminated or PVC sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated FRLS unsheathed 1100 Volts grade cable with stranded copper conductor of size 2.5 Sq mm for 15 Amps (Nominal area) complete all as specified and directed.
S&F switch piano flush type single pole, one way 15A complete all as specified and directed.
S&F socket outlet 2 in 1 , 3 pin 15 A flush type complete all as specified and directed.
M&L for 3 phase Surge Protection Device (SPD) type 1+2AC, 25 KA Including MCB 4 pole 63 Amps before SPD with all incoming & outgoing connection of LT Cable upto 240Sqmm & for fixing the SPD with SPN DB 8 way double door enclosure all as directed and specified. Make :- Schneider/ ABB/ Legrand
Supply and install hi wall split units indoor /outdoor complete with cordless remote control unit and with inbuilt with air ioniser on plasma filter for better indoor air quality with min. 4 star rating and EER 3.2 of capacity of 1.5 Ton capacity complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one Double pole pole MCB 240 Volrt 20 Amp complete all as specified and directed.
M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 1.5 sqmm drawn through PVC conduit 25mm dia ISI marked as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 1.5 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly complete all as specified and directed. Note : Two runs of 1.5 sqmm cable alongwith one run of 1.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length
M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 2.5 sqmm drawn through PVC conduit 25mm dia ISI marked as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2.5 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly complete all as specified and directed. Note : Two runs of 2.5 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit 25mm dia ISI marked as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly complete all as specified and directed. Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length
S&F sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
S&F MCBs SPN 63 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
S&F MCBs SP 5 to 40 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified and directed.
S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63A complete all as specified and directed.
Supply Installation Testing and Commissioning of a set of maintenance free tripod earthing system consisting of 3 No. of Copper Bonded Earth Rod of 10 feet length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x50x6mm for long lasting and connection . Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 25KA Fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriter laboratories confirming to comply with UL467 international standard for grounding and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed , Resisitivity of the earth enhancing compond should be less than 0.05 ohm meter - an international standard for Earth Enhancement Compound by NABL accredit Lab, complete all as direcected by Engr -in- charge. Note : The rate for interconnection of tripod earth with Copper strip of size 20x3 mm and poly carbonate earth pit cover -03 Nos shall deemed to be included in the quoted rates. The Earth result should be less than 1 ohm and the result will be checkedin presence of user rep & MES Rep.
Supply and fixing metal body exhaust fan 380 mm sweep single phase 230 volts with Louvers shutter complete including making hole of suitable size in wall and make good the disturbed surface complete all as direcected by Engr -in- charge.
Supply and fixing metal body exhaust fan 450 mm sweep single phase 230 volts with Louvers shutter complete including making hole of suitable size in wall and make good the disturbed surface complete all as direcected by Engr -in- charge.
M & L for point wiring on wall/ surface in PVC conduit/ casing caping of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through PVC conduit/casing caping including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete for the following :-
M&L switch piano flush type single pole, one way 6amp .
S/fix ceiling rose 65x17mm of three terminals.
Supply, install, testing and commissioning of CPRI approved LT Panel board, outdoor cubicle , dust and vermin proof made out of 3.15mm thick MS sheet with front and back door openable type fitted with nuts, bolts and washers fitted with knobs and hinges incl painting with two coats of enamelled paint over a coat of red oxide primer suitable for 415Volts 50Hz, 3 phase, 4 wire suitable and including the following :- (a) MCCB FP 415V 200Amps 35kA, adjustable thermal & magnetic settings - 01 No as incomer (b) MCCB TP 415V 125Amps 25kA, adjustable thermal & magnetic settings - 01 No as outgoing(Storage No. I & II) (c) MCB TP 63A, 10kA adjustable thermal & magnetic settings- 01 No as outgoing (d) Digital Voltmeter 0-500V - 01 No (e) Digital Ammeter 0-2000A with CTs 01 No (f) Indicators RYB LED type - Set of three (g) Aluminium bus bars 400 A TPN - 01 Set (h) Internal wiring of panel board with copper cable of appropriate size single core including control fuses and cable glands, lugs of sutable size for incoming and outgoing cables, earthing terminals and cable glands
Supply and spread clean dry river sand traveles for cushing of UG cables complete all as specified and directed.
M&L for bricks of size 230 x 115 x 75 mm perpendicular to the cable abutting each other all as specified and directed over sand cushioning for protection of UG cable in trenches, complete all as specified and directed.
Supply and laying GI pipe light grade 40mm size under hard standing and road for cable protection with all fittings, complete all as specified and directed.
S & laying, testing LT Cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5Core including all joints complete all as specified and directed
Supply and fix on load change over switch 415V in existing panel of capacity 4 pole 63Amps, complete all as specified and directed.
Supply and fix on load change over switch 415V in existing panel of capacity 4 pole 125Amps, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick buried directly in ground vertically to a depth of not less than 2.25M below ground level with the top edge of earth plate at a depth of not less than 1.5m below normal ground level connected to GI earth strip of 32 x 6mm by means of bolts, nuts, check nuts, washers, protected by GI pipe 15 mm bore, light grade and 20 mm GI pipe med grade for water with wire mesh funnel all as shown on electrical plate No.03 of SSR Part-I complete including necessary excavation & earth work in any type of soil and PCC(1:3:6) type CI using 20mm graded stone aggregate earth chamber, RCC (1:2:4) type B1 cover slab 40mm thick complete including testing complete all as specified and directed.
M&L copper strip 20x3mm on FRP insulator fixed on wall/ MS sheet or floors including connecting to lightening arrester/earthing/test point strip should be brazed/ welded at each joint complete all as specified and directed.
M/s Kang Builders
Swami Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .