| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAdmitted-Finance 10TH FLOOR VATIKA BUSINESS PARK BLOCK II SOHNA ROAD SECTOR 49 GURGAON HARYANA 122002 | GURGAON | GURGAON | HARYANA | 122002 | L1 | Admitted-Finance | |
| 2 | L2₹33.1 L+₹19.4 L (142.4%)Admitted-Finance B 17 I P I A ROAD NO 2 KOTA | KOTA | RAJASTHAN | 324001 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | STRYKER INDIA PRIVATE LTD L1 | AKASH ASSOCIATES L2 |
|---|---|---|---|---|---|
| 1.00Group –A: DIAGNOSTIC AND ACCESSORIES All the consumable Items must be approved/ being used in leading Govt. hospitals in India like AIIMS, New Delhi, PGI-Chandigarh,SGPGI-Lucknow, SMS Jaipur etc. | |||||
| 1.01 | LONG INTRODUCER SHEATH
· Sizes4fr,5fr, 6fr,7Fr, 8Fr, &9 French and above
· Should be Available in length from 65- 90 cm long
· 0.021 to 0.038-inch guide wire compatible
· Kink resistant | 1 | Each | - | - |
| 1.02 | INTRODUCER SHEATH FOR ADULT
· Sizes 4fr,5fr, 6fr,7Fr, 8Fr, &9 French and above
· Should be 10-24cm
· 0.021 or 0.038 inch guide wire compatible
· Kink resistant
· With dilator-hub lock mechanism to prevent its back-out during insertion | 1 | Each | - | 715 ₹715 Lowest |
| 1.03 | LONG INTRODUCER sheath 90 CM or Above (stainless steel BRAIDED ) :
Should be available in 6fr,7fr with 0.088 in – 0.091 inch with rounded automatic tip | 1 | Each | 34,500 ₹34,500 Lowest | - |
| 1.04 | PUNCTURE NEEDLE FOR VASCULAR ACCESS IN ADULT (18G) | 1 | Each | - | 35 ₹35 Lowest |
| 1.05 | MICRO PUNCTURE NEEDLE FOR VASCULAR ACCESS IN CHILDREN- (20-22G) | 1 | Each | - | - |
| 1.06 | HEAD HUNTER CATHETER
· In various standard lengths and curves
· 035-038 compatible
· 100 cm long | 1 | Each | - | - |
| 1.07 | SIMMONS/ SIDEWINDER CATHETER
• In various standard lengths and curves
• 035-038 compatible
• 100 cm long | 1 | Each | - | - |
| 1.08 | VERTEBRAL CATHETER -In various standard lengths and curves | 1 | Each | - | - |
| 1.09 | DISTAL ACCESS Catheter for CO- Axial Systems
• In various standard lengths
• 5f, 6f,7fr size
• 0.035” to .070”, .074 inner lumen. | 1 | Each | 34,000 ₹34,000 Lowest | 61,900 ₹61,900 |
Tender Value
₹10 Cr
EMD Value
₹20 L
Closing Date
10 May 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPDT. AND MEM. SEC. R.M.R.S.,M.B.S. HOSPITAL KOTA
MBS HOSPITAL KOTA
SUPPLY OF CONSUMABLE IN NEURO INTERVANTION LAB IN MBS HOSPITAL KOTA (RATE CONTRACT TWO YEAR)
2023_GMCK_330044_1
NITNO-01-2023-24
Open Tender
Medical Equipments/Waste
Item Rate
720 days
KOTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
2500 SUPDT. AND MEM. SEC. R.M.R.S.,M.B.S. HOSPITAL
₹20 L
Yes
MBS HOSPITAL KOTA
14 Aug 2023
16 Apr 2023
11 May 2023
16 Apr 2023
10 May 2023
16 Apr 2023
17 Apr 2023
Amount
Group –A: DIAGNOSTIC AND ACCESSORIES All the consumable Items must be approved/ being used in leading Govt. hospitals in India like AIIMS, New Delhi, PGI-Chandigarh,SGPGI-Lucknow, SMS Jaipur etc.
LONG INTRODUCER SHEATH · Sizes4fr,5fr, 6fr,7Fr, 8Fr, &9 French and above · Should be Available in length from 65- 90 cm long · 0.021 to 0.038-inch guide wire compatible · Kink resistant
INTRODUCER SHEATH FOR ADULT · Sizes 4fr,5fr, 6fr,7Fr, 8Fr, &9 French and above · Should be 10-24cm · 0.021 or 0.038 inch guide wire compatible · Kink resistant · With dilator-hub lock mechanism to prevent its back-out during insertion
LONG INTRODUCER sheath 90 CM or Above (stainless steel BRAIDED ) : Should be available in 6fr,7fr with 0.088 in – 0.091 inch with rounded automatic tip
PUNCTURE NEEDLE FOR VASCULAR ACCESS IN ADULT (18G)
MICRO PUNCTURE NEEDLE FOR VASCULAR ACCESS IN CHILDREN- (20-22G)
HEAD HUNTER CATHETER · In various standard lengths and curves · 035-038 compatible · 100 cm long
SIMMONS/ SIDEWINDER CATHETER • In various standard lengths and curves • 035-038 compatible • 100 cm long
VERTEBRAL CATHETER -In various standard lengths and curves
DISTAL ACCESS Catheter for CO- Axial Systems • In various standard lengths • 5f, 6f,7fr size • 0.035” to .070”, .074 inner lumen.
SHEPHERD’S HOOK CATHETER In various standard lengths and curves
PIGTAIL CATHETER 4 French/5 French /6 French/7 French/8French in various standard lengths.
COURNARD CATHETER 4 French/5 French /6 French/7 French/8French in various standard curves and lengths.
COBRA TYPE CATHETER • In various standard lengths and curves. • 4Fr, 5fr, 6fr size
HYDROPHILIC DIAGNOSTIC GUIDE WIRE – TYPE (REGULAR LENGTH, REGULAR STIFFNESS) • Must be available in 0.025, 0.032, 0.035 and 0.038 inches size • Should have superelastic alloy core • Should have super flexible wire tip • Should be available in straight and angled tip • Should be between 120-150 cm long
HYDROPHILIC DIAGNOSTIC GUIDE WIRE – TYPE (EXCHANGELENGTH,EXTRA STIFFNESS) • Must be available in 0.025, 0.032, 0.035 and 0.038 inches size • Should have superelastic alloy core • Should have super flexible wire tip • Should be available in straight and angled tip • Should be between 180-260 cm long
BALLOON TIPPED GUIDING CATHETER SIZES 6Fr,7 fr,8 fr,9fr,10 fr
INFLATION DEVICE WITH ANALOG DISPLAY
TUOHY BORST HAEMOSTATIC Y-CONNECTOR
TUOHY BORSTHAEMOSTATIC Y-CONNECTOR WITH DOUBLE SIDE ARM
DISPOSABLE LUER LOCK SYRINGE • SHOULD BE COMPITABLE WITH CUANOACRYLATE. • SHOULD BE AVAILABLE IN 1 C.C/2C.C/3C.C/5C.C/10 C.C/20 C.C/ 50C.C
PICARD CATHETER • In various standard lengths and curves • 035-038 compatible 100 cm long
ENVOY CATHETER • In various standard lengths and curves • 058-070 compatible 100 cm long
AMPLATZ CATHETER : • In various standard lengths and curves • 035-038 compatible 100 cm long
Group –B: CAROTID ANGIOPLASTY All the consumable Items must be approved/ being used in leading Govt. hospitals in India like AIIMS, New Delhi, PGI-Chandigarh, SGPGI-Lucknow, SMS Jaipur etc.
Guiding catheter for Neuro Vascular Use • Should have atraumatic soft tip& flexible shaft • Should be available in various tip shapes and curves for access to different parts of the Neuro vasculature • Should have Outer Diameter of 6Fr,7 fr,8 fr,9fr,10 fr available • Should have Inner Diameter of 4.2fr • Should have various lengths from 90-110 cm
PROXIMAL NEURO-PROTECTION DEVICE FOR EMBOLIC PROTECTION (PROXIMAL BALLOON OCCLUSION TECHNIQUE)
DISTAL NEURO-PROTECTION DEVICE FOR EMBOLIC PROTECTION (FILTER WITH PROXIMAL BALLOON OCCLUSION TECHNIQUE)
DISTAL NEURO-PROTECTION DEVICE FOR EMBOLIC PROTECTION (FILTER) • Should be on a .014” wire • Should be made of polyurethane with radio-opaque nitinol loop • Should be suspended on the .014” wire with a suspension arm • Should not occlude flow while in placement • Should be rapid exchange type • Should be compatible with a 6 F guiding catheter (0.066” ID) • Should allow optimal filtration in vessels 3.5 – 5.5 mm size
CAROTID ANGIOPALSTY BALLOON CATHETER (Over The Wire/Rapid Exchange) • Should have hydrophilic coating • Should be available in various outer diameters and balloon lengths and various shaft lengths
CAROTID SELF EXPENDABLE STENTS • Should be 0.014” compatible • Should be over the wire and rapid exchange (OTW/RX) • Should be available in various diameters and length Should be on a shaft length of 80-140 or above length
CAROTID SELF EXPENDABLE STENTS • Should be 0.018” compatible • Should be over the wire and rapid exchange (OTW/RX) • Should be available in various diameters and length • Should be on a shaft length of 80-140 or above length
CAROTID SELF EXPENDABLE STENTS • Should be 0.035” compatible • Should be over the wire and rapid exchange (OTW/RX) • Should be available in various diameters and length • Should be on a shaft length of 80-140 or above length
CAROTID STENTS BALLOON EXPENDABLE • Should be 0.014” compatible • Should be over the wire and rapid exchange (OTW/RX) • Should be available in various diameters and length • Should be on a shaft length of 80-140 or above length
CAROTID STENTS BALLOON EXPENDABLE • Should be 0.018” compatible • Should be over the wire and rapid exchange (OTW/RX) • Should be available in various diameters and length • Should be on a shaft length of 80-140 or above length
CAROTID SELF EXPENDABLE STENTS WITH TAPERED DIAMETER • Should be 0.014” compatible • Should be over the wire and rapid exchange (OTW/RX) • Should be available in various diameters and length • Should be on a shaft length of 80-140 or above length
PERIPHERAL Balloon Expandable STENT – (OTW/RX) • Should be 0.014/0.018” compatible • Should over the wire • Should be made of cobalt chromium / Bare • Should have balloon OD available in 4-7 mm • Should have balloon/stent lengths of 12-18 mm • Should have shaft lengths of 80-150 cm
Group–C: ANEURYSMS COILS& ADHESIVES All the consumable Items must be approved/ being used in leading Govt. hospitals in India like AIIMS, New Delhi, PGI-Chandigarh, SGPGI-Lucknow, SMS Jaipur etc.
SPECIAL MICRO GUIDEWIRE WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS (SIZE: 0.007”- 0.014”)
SPECIAL MICRO GUIDEWIRE (EXCHANGE LENGTH- 260- 300 CMs) WITH TORQUE DEVICE FOR USE WITH MICROCATHETERS (SIZE: 0.010”- 0.014’)
ELECTROLYTE DETACHABLE 3-D TYPE/ HELICAL/ 360 COILS FOR INTRACRANIAL ANEURYSMS TREATMENT- BARE PLATINUM COILS
ELECTROLYTE DETACHABLE 3-D TYPE/ HELICAL/ 360 COILS FOR INTRACRANIAL ANEURYSMS TREATMENT- COATED/BIOACTIVE PLATINUM COILS
THERMO MECHANICAL DETACHABLE 3-D TYPE/ HELICAL/ 360 COILS FOR INTRACRANIAL ANEURYSMS TREATMENT- NON-BIOACTIVE PLATINUM COILS
THERMO MECHANICAL DETACHABLE 3-D TYPE/ HELICAL/ 360 COILS FOR INTRACRANIAL ANEURYSMS TREATMENT- BARE PLATINUM COILS
MECHANICAL DETACHABLE 3-D TYPE/ HELICAL/ 360 COILS FOR INTRACRANIAL ANEURYSMS TREATMENT- BARE PLATINUM SHOULD BE AVAILABLE FROM VARIOUS SIZES FROM 1.0 MM – 4.0MM DIAMETER
MACHENICAL DETACHABLE 3-D TYPE/ HELICAL/ 360 COILS FOR INTRACRANIAL ANEURYSMS TREATMENT- COATED PLATINUM COILS
POWER SUPPLY ACCESSORIES AND CONNECTING CABLES FOR DETACHABLE COILS
DETACHABLE BALLOON CATHETER
DETACHABLE BALLOON MICROCATHETER FOR DETACHABLE BALLOONS
TISSUE ADHESIVE FOR AVMs/AVFs/DAVFs/TUMOR-EMBOLIZATION (N-BUTYL CYANOACRYLATE)
POLY VINYL ALCOHOL (PVA) PARTICLES FOR PRE-OPERATIVE TUMOUR EMBOLIZATION
ETHYL VINYL ALCOHOL EMBOLIC AGENT (WITH DMSO) FOR AVMs/AVFs/DAVFs/TUMOR-EMBOLIZATION
LIPIDOL ULTRA FLUID
Group-D: STENTS& BALLOONS FOR CRANIAL USE All the consumable Items must be approved/ being used in leading Govt. hospitals in India like AIIMS, New Delhi, PGI-Chandigarh, SGPGI-Lucknow, SMS Jaipur etc.
DOUBLE LUMEN BALLOON ANGIOPLASTY CATHETER FOR INTRA-CRANIAL USE
OPEN CELL DESIGN INTRA-CRANIAL STENTS FOR STENT ASSISTED COILING OF ANEURYSMS • SHOULD HAVE OPEN CELL DESIGN • SHOULD BE AVAILBLE IN VARIOUS SIZES & DIAMETER
CLOSED CELL DESIGN INTRA-CRENIALSTENTS FOR STENT ASSISTED COILING OF ANEURYSMS • SHOULD BE COMPITABLE FOR SMALL/ LARGE VESSEL • SHOULD BE AVAILBLE IN VARIOUS SIZES & DIAMETER
EXTRA-CRANIAL STENT FOR CAROTID & VERTEBRAL ARTERIES & DURAL SINUSES: SELF EXPANDABLE & CLOSED CELL DESIGN
EXTRA-CRANIAL BARE METAL STENT FOR CAROTID & VERTEBRAL ARTERIES & OSTEAL LESIONS: BALLOON MOUNTED
SELF EXPANDABLE INTRA-CRANIAL STENT FOR TREATMENT OF ATHEROSCLEROTIC STENOTIC LESIONS OF INTRACRANIAL VESSELS
BALLOON MOUNTED INTRA-CRANIAL STENT FOR TREATMENT OF ATHEROSCLEROTIC STENOTIC LESIONS OF INTRACRENIAL VESSELS
STENT-GRAFT (Covered Stent) FOR PSEUDO ANEURYSM OR FISTULA TREATMENT
FLOW DIVERTER FOR INTRACRANIAL ANEURYSM TREATMENT
SINGLE LUMEN BALLOON ANGIOPLASTY CATHETER FOR INTRA-CRANIAL USE
HYBRID CELL DESIGN INTRA-CRANIAL STENTS FOR STENT ASSISTED COILING OF ANEURYSMS • SHOULD HAVE OPEN CELL DESIGN SHOULD BE AVAILBLE IN VARIOUS SIZES & DIAMETER
Group –E: CLOT RETRIEVAL DEVICES FOR THROMBECTOMY All the consumable Items must be approved/ being used in leading Govt. hospitals in India like AIIMS, New Delhi, PGI-Chandigarh, SGPGI-Lucknow, SMS Jaipur etc.
REVASCULARIZATION DEVICE FOR MECHANICAL THROMBECTOMY
ENDO VASCULAR SNARES FOR RETRIEVAL OF INTRAVASCULAR FORIEGN OBJECT
THROMBUS SUCTION CATHETERS FOR CLOT RETRIEVAL FROM CAROTID & VERTEBRALS
INFUSION CATHETERS FOR MOTORIZED FRAGMENTATION AND SUCTION FOR CLOT RETRIEVAL WITH SEPARATOR
STENT RETRIEVER FOR THROMBECTOMY
WEB DEVICE INTRA SACCULAR – AVAILABLE IN ASSORTED SIZES
FULLY VISIBLE UNDER FLUOROSCOPY REVASCULARIZATION DEVICE FOR MECHANICAL THROMBECTOMY
Group – F: EMBOLIZATION/AVMs All the consumable Items must be approved/ being used in leading Govt. hospitals in India like AIIMS, New Delhi, PGI-Chandigarh, SGPGI-Lucknow, SMS Jaipur etc.
AKASH ASSOCIATES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
TECHANICAL-BID-NERUO-IMPLANTS.pdf
Tender Documents • 13.38 MB
BOQ_586170.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .