Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-Finance FIRST FLOOR DOOR NO 3 BQ COMPLEX OPP GRAMAPANCHAYAT MALAYINKEEZHU P O THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695571 | L1 | Accepted-Finance AS PER RESOLUTION | |
| 2 | L2₹4.1 L+₹10,929.15 (2.77%)Rejected-Finance | L2 | Rejected-Finance AS PER RESOLUTION | |
| 3 | Rejected-Technical ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | - | Rejected-Technical AS PER RESOLUTION | |
| 4 | Rejected-Technical ASSISTANT EXECUTIVE ENGINEER PANTALAM MUNICIPALITY DISTRICT TREASURY ALAPPUZHA | - | Rejected-Technical AS PER RESOLUTION |
| Sl No | Description | Qty | Unit | BOSS LIGHT L1 | Sreekumar P L3 | Kerala SIDCO Ltd L2 | Angel electricals L4 |
|---|---|---|---|---|---|---|---|
| 1.00Annual Plan-MINI MAST - Installation and Commissioning of 2 No. New Minimast Lights and Maintenance of 6 No. existing Minimast Lights-Project No. S0246/25 of Pandalam Municipality-General Electrical Work | |||||||
| 1.00 | 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters | 2 | each | 23,500 ₹47,000 Lowest | 29,842 ₹59,684 | 25,100 ₹50,200 | 29,000 ₹58,000 |
| 1.00 | 90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 10 | each | 11,000 ₹1,10,000 | 13,680 ₹1,36,800 | 8,500 ₹85,000 Lowest | 16,000 ₹1,60,000 |
| 1.00 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 6 | each | 6,500 ₹39,000 Lowest | 9,000 ₹54,000 | 7,500 ₹45,000 | 10,200 ₹61,200 |
| 1.00 | 90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 10 | each | 5,100 ₹51,000 Lowest | 7,200 ₹72,000 | 5,500 ₹55,000 | 8,100 ₹81,000 |
| 1.00 | OD423104/2024-2025:Supply and providing 6mm thick Bakelite sheet of required size for fixing 3 or 4 SP MCBs and with 16sq:mm Stud Terminals for mounting inside the base compartment of the Octagonal Pole. | 4 | each | 250 ₹1,000 Lowest | 1,039.95 ₹4,159.8 | 500 ₹2,000 | 1,000 ₹4,000 |
| 1.01 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 3.2 | cum | 980 ₹3,136 | 396.13 ₹1,267.62 | 3,665 ₹11,728 | 396 ₹1,267.2 Lowest |
| 1.01 | 14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. | 0.29 | cum | 7,500 ₹2,175 Lowest | 7,962.13 ₹2,309.02 | 27,586 ₹7,999.94 | 7,900 ₹2,291 |
| 1.01 | OD423107/2024-2025:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tore steel | 50 | kg | 175 ₹8,750 | 84.67 ₹4,233.5 | 325.6 ₹16,280 | 84 ₹4,200 Lowest |
| 1.01 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. | 0.93 | cum | 10,600 ₹9,858 | 9,087.41 ₹8,451.29 | 4,301 ₹3,999.93 Lowest | 9,000 ₹8,370 |
Tender Value
₹5.1 L
EMD Value
₹12,863
Closing Date
9 Apr 2025, 2:00 pmClosed
JAYAKUMAR K
AE
246/25 MINI MAST LIGHT
2025_LSGD_756135_1
246/AE/LSGD/PDM/24-25
Open Tender
Electrical Works
Item Rate
PANDALAM MUNICIPALITY
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,135
Yes
₹12,863
Yes
28 Aug 2025
28 Mar 2025
9 Apr 2025
28 Mar 2025
9 Apr 2025
28 Mar 2025
Amount
Annual Plan-MINI MAST - Installation and Commissioning of 2 No. New Minimast Lights and Maintenance of 6 No. existing Minimast Lights-Project No. S0246/25 of Pandalam Municipality-General Electrical Work
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD423104/2024-2025:Supply and providing 6mm thick Bakelite sheet of required size for fixing 3 or 4 SP MCBs and with 16sq:mm Stud Terminals for mounting inside the base compartment of the Octagonal Pole.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
OD423107/2024-2025:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tore steel
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.3:Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD423105/2024-2025:Supply, installation, testing and commissioning of freestanding LT Panel Board with base supported on angle iron frame, made of 16 gauge sheet steel, phosphatised and painted, dust and vermin proof, Weatherproof, IP 65/ IP67 having two separate compartments arranged vertically with required no. of knock outs for cable entry as per the approved design, the upper compartment for accommodating Single phase Energy Meter with provision for fixing 1No. HRC Fuse, neutral link & DIN rail suitable for fixing ELCB and lower compartment as control module having DIN rails in two rows, suitable for fixing MCB/ isolator /Contactor/ Timer etc. and with provision for locking of both the compartments.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD423103/2024-2025:Supply and installation of Programmable time switch 24 Hour (Timer) with dual contactor/ Light Sensor suitable for outdoor light fittings, Hager/ L&T / Havells make.
OD423102/2024-2025:Supply and fixing 230V, 25A, 3 Pole Mini contactor, AC 3 Rating with AC coil, L&T make, Model MNX 22 or equivalent in the existing LV Panel Board and giving connections etc. as required..
OD423100/2024-2025: Supply and fixing 6A, Two way Toggle Switch (Auto-Manual Switch) in the indication panel of LV Panel / Switch Board.
90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
OD423098/2024-2025:Supply and providing 32A, 415 V Bakelite fuse fitting in the existing meter board and giving connections etc.
OD423110/2024-2025:Supply of 32A, 415V, 2way Neutral link mounted on DMC/ SMC base and fixing in the existing Energy Meter Box and giving connections etc.
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
OD423108/2024-2025:Supplying and clamping 16mm dia corrugated PVC flexible conduit with necessary compression gland with locking ring and check nut at termination points, suitably fixing inside the LV Panel / clamping using suitable size GI / painted MS saddles, spacing not exceeding 60cms on surface etc. as required.
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD423101/2024-2025:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/cm2- Internal work - Exposed on wall, as per item specification No. 50.18.7.3.1 for Civil works. T
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
OD423097/2024-2025: Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / Earth bus etc. as required including drilling necessary holes as required.
OD423096/2024-2025:Supplying and installation of supports / suspenders, anchor bolts etc. made out of suitable size channel sections, single section square tube, slotted angles, flats, MS plates, iron rods etc. as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc. as required.
OD423099/2024-2025: Charges for preparation of KSEB service connection documents for availing single phase service connection / regularisation of additional load and producing to the consumer including submitting test report, drawing etc.
Kerala SIDCO Ltd (BID ID -2191805)
Sreekumar P (BID ID -2192418)
Angel electricals (BID ID -2192156)
Bidder Name
BOSS LIGHT
Sreekumar P
Angel electricals
Kerala SIDCO Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_1227966.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .