| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC Awareded |
| 2 | L2₹1.8 Cr+₹56,546.14 (0.32%)Rejected-Finance | ₹1.8 Cr+₹56,546.14 (0.32%) | L2 | Rejected-Finance rejected |
| 3 | L3₹1.8 Cr+₹3.0 L (1.74%)Rejected-Finance BANSAL NIWAS RAM NAGAR SHIMLA 171004 HIMACHAL PRADESH | SHIMLA | HIMACHAL PRADESH | 171004 | ₹1.8 Cr+₹3.0 L (1.74%) | L3 | Rejected-Finance Rejected |
Tender Value
₹1.4 Cr
EMD Value
₹1.7 L
Closing Date
30 Jul 2024, 5:00 pmClosed
District Project Manager, HPCDP (Phase-II), JICA-O
District Project Manager, HPCDP (Phase-II), JICA-ODA, Mandi Distt. Mandi (H.P.). Agriculture Complex Khaliyar Mandi Distt. Mandi (H.P).
C/o Flow Irrigation Scheme Delag Tikkari at Village Tikkari , G.P. Delag,Tehsil Chachyot, District Mandi (H.P.)., C/o Flow Irrigation Scheme Gawad at Village Gawad , G.P. Gawad,Tehsil Chachyot, District Mandi (H.P.). and C/o Flow Irrigation Schem
2024_HPCDP_90739_1
F(5)-93/2024-548dt19.07.2024
Open Tender
Civil Works - Water Works
Item Rate
365 days
Village Tikkari, G.P. Delag, Tehsil Chachyot, Dis
Please refer Tender documents.
15 documents required · 15 mandatory
₹5,000
District Project Manager, HPCDP (Phase-II), JICA-O
₹1.7 L
District Project Manager, HPCDP (Phase-II), JICA-O
6 Sept 2024
19 Jul 2024
31 Jul 2024
19 Jul 2024
30 Jul 2024
19 Jul 2024
24 Jul 2024
Amount
C/o Flow Irrigation Scheme Deoli to Delag Tikkari, G.P. Delag ,Tehsil Chachyot, District Mandi (H.P.)
Demolishing of cement concrete manually/ by mechanical means including disposal of material within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Excavation work by mechanical means / manual means in foundation trenches or drains , including dressing of sides and ramming of bottoms , lift up to 1.5 mtr. Including getting out the exvcavbated soil and disposal of surplus excavated soil as directed , within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation, trenches or drains, pits upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, chieselling soft / hard rock including getting out the excavated soil, dressing of sides, ramming of bottoms and returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all lead and lifts including restoration of unmettalled surfaces to its original condition complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Dismantling of old plaster or skirting raing out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns, mass concrete complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Suspended floor , roofs , landing , balconies and access plateform etc.complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Column , Pillar, Piers, abutments, posts and struts etc.complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge. (Extra for shuttering in circular work (20% of respective centering and shuttering item)
Edges of slab and break in floor and walls complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Extra Allowance for formwork in concrete lining in:
In sides complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
In sides complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Providing and laying in position cement concrete 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of centering and shuttering All work up to plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of centering and shuttering for all work up to plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position reinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete in :
All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position reinforced cement concrete 1:1:2 ( 1cement : 1 sand : 2 graded stone aggregate 20 mm nominal size) and curing complete:
In foundation, beams, suspended floors, roofs having slope landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing cement concrete lining 15 cm thick or less for irrigation channels, using cement concrete 1:2:4 (1 cement2 sand :4 stone aggregate 20 mm nominal size) in:
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Side slopes complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing CI Sluice Valve of following dia & class of Leader / Kartar / Kirloskar make with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
80 mm dia, PN-1.0 (10.2 Kg/cm²)
150 mm dia, PN-1.0 (10.2 Kg/cm²)
Providing, laying, jointing , commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239: 2004, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing ,cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
150 mm Dia
Providing and welding M.S. flanges @ 1% of joints, conforming to following tables as per IS 6392-1971 (Latest with upto date amendments) 150 mm Dia Medium Class with plain end GI pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of GI pipes to be measured and paid for seprately). The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.
Providing circumferencial Butt welded joints by electrical arc welding to G.I pipe having 150 mm dia of pipe, wall thickness, welded in requisite numbers of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of ADVANI Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
Providing, laying, jointing, commissioning & testing in trenches HDPE pipes of following diameters & classes as per IS 4984 (1995) and jointing the pipes with push type compression joints by hydraulically operated machines, butt fussion welding & electro fusion welding machines i/c necessary fittings, bends, tees, unions, flanges, collars & reducers etc. confirming to IS 8360 & IS 8008 with latest ammendments & shall be provided as per site conditions. Flanging of the pipes shall be made as & where required. Jointing shall be confirming to IS code 8008 & IS 7634, stub ends will be welded on pipes & MS flange shall be provided with slip on covered by epoxy coating/plastic powder. The flange should be confirm to ANSI B 16.5 with necessary nuts & bolts. All manufacturing maerial used shall be in accordance to IS 4427-2007 (latest revision) with 100 % virigin pre-compounded or natural PE resin. Jointing shall be complete in all respects i/c testing at site upto entire satisfaction of the Engineer-in-Charge.
90 mm dia HDPE pipe (PN 6.0, PE 100)
Providing M.S Flat 50x5 mm Clamps & 16 mm Dia Nut Bolts for suporting the MSERW Pipe over the RCC Column provided at 6 mtr. Interval complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Finishing with epoxy paint (two or more coats) at all locations prepared on steel work and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Cutting of MS Plate permanents engraving marked scale/ calibration on the plate and fixed at the site of work complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Fencing with angle iron post at required distance embeded in cement concrete blocks , every 15th post , last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonal interwoven with horizontal wires , of babrbed wire weighing 9.38 kg. per 100m (minimum), betwwen the two posts fitted and fixed with G.I staple , turn buckels etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Restoration charges for digging of Katcha road & shoulder including getting permission from concerned authority & repair the same complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Writing new letters and figures of any shade with synthetic enamel black or any other approved colour to give an even shade as per drawings and technical specifications clause 1701 in English and roman, hyphen, commas and the like not to be measured and paid complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
C/o Flow Irrigation Scheme Gawad at Village Gawad , G.P Gawad, Tehsil Chachyot, District Mandi (H.P.).
Demolishing of cement concrete manually/ by mechanical means including disposal of material within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Excavation work by mechanical means / manual means in foundation trenches or drains , including dressing of sides and ramming of bottoms , lift up to 1.5 mtr. Including getting out the exvcavbated soil and disposal of surplus excavated soil as directed , within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation, trenches or drains, pits upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, chieselling soft / hard rock including getting out the excavated soil, dressing of sides, ramming of bottoms and returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all lead and lifts including restoration of unmettalled surfaces to its original condition complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns, mass concrete complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Column , Pillar, Piers, abutments, posts and struts etc.complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Edges of slab and break in floor and walls complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Extra Allowance for formwork in concrete lining in:
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
In sides complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Providing and laying in position cement concrete 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of centering and shuttering All work up to plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of centering and shuttering for all work up to plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor etc., up to floor five level,excluding the cost of centering, shuttering and finishing with in all leads & lifts in all respect and to the entire satisfaction of the Engineer in Charge.
Providing and laying in position reinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete in :
All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing cement concrete lining 15 cm thick or less for irrigation channels, using cement concrete 1:2:4 (1 cement2 sand :4 stone aggregate 20 mm nominal size) in:
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Side slopes complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Stone/ Boulder filling behind the Retaining wall , also under floor and upstream of i/ gallery/ under floor etc.complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing CI Sluice Valve of following dia & class of Leader / Kartar / Kirloskar make with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
80 mm dia, PN-1.0 (10.2 Kg/cm²)
150 mm dia, PN-1.0 (10.2 Kg/cm²)
Providing, laying, jointing, commissioning & testing in trenches HDPE pipes of following diameters & classes as per IS 4984 (1995) and jointing the pipes with push type compression joints by hydraulically operated machines, butt fussion welding & electro fusion welding machines i/c necessary fittings, bends, tees, unions, flanges, collars & reducers etc. confirming to IS 8360 & IS 8008 with latest ammendments & shall be provided as per site conditions. Flanging of the pipes shall be made as & where required. Jointing shall be confirming to IS code 8008 & IS 7634, stub ends will be welded on pipes & MS flange shall be provided with slip on covered by epoxy coating/plastic powder. The flange should be confirm to ANSI B 16.5 with necessary nuts & bolts. All manufacturing maerial used shall be in accordance to IS 4427-2007 (latest revision) with 100 % virigin pre-compounded or natural PE resin. Jointing shall be complete in all respects i/c testing at site upto entire satisfaction of the Engineer-in-Charge.
90 mm dia HDPE pipe (PN 6.0, PE 100)
Providing, laying, jointing , commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239: 2004, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing ,cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
100 mm Dia
150 mm Dia
Providing and welding M.S Flanges, joint conforming o table as per IS 6392-1971(Latest with up to date amendments) with plain end G.I pipe in requisite number of layers on both faces to makethe joint leak proof (The cost of Providing and laying of G.I pipe to be measured oaid separately). The weldingof flanges should conforms to IS:816-1969 withelectrode as per IS :814-1991 and required number of nuts and bolts conforming to is:1364. Including cost of gasket sheet nuts and bolts. The thickness of gasket sheet not be less than 3.00 mm conforming to IS: -2712-1998. The work shall be done to the entire satisfaction of engineer in charge with all in leads and lifts.(100 mm dia G.I Pipe)
Providing circumferencial Butt welded joints by electrical arc welding to G.I pipe having 100 mm dia of pipe, wall thickness, welded in requisite numbers of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of ADVANI Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
Finishing with epoxy paint (two or more coats) at all locations prepared on steel work and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Restoration charges for digging of metalled road & shoulder including getting permission from concerned authority & repair the same complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Cutting of MS Plate permanents engraving marked scale/ calibration on the plate and fixed at the site of work complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Writing new letters and figures of any shade with synthetic enamel black or any other approved colour to give an even shade as per drawings and technical specifications clause 1701 in English and roman, hyphen, commas and the like not to be measured and paid complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
C/o Flow Irrigation Scheme Kharkan Khad to Lehoti at Village Oari & Dari , G.P Nehra & Bassa, Tehsil Chachyot, District Mandi (H.P.).
Demolishing of cement concrete manually/ by mechanical means including disposal of material within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation, trenches or drains, pits upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, chieselling soft / hard rock including getting out the excavated soil, dressing of sides, ramming of bottoms and returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Excavation work by mechanical means / manual means in foundation trenches or drains , including dressing of sides and ramming of bottoms , lift up to 1.5 mtr. Including getting out the exvcavbated soil and disposal of surplus excavated soil as directed , within all leads and lifts complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and then disposing of surplus excavated soil as directed, within all lead and lifts including restoration of unmettalled surfaces to its original condition complete in all respect and to the entire satisfaction of the Engineer-in-Charge.
Centering and shuttering including strutting, propping etc. and removal of form work for :
Foundations, footings, bases for columns, mass concrete complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Edges of slab and break in floor and walls complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Extra Allowance for formwork in concrete lining in:
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
In sides complete in all respect within all leads and lifts and to the entire satisfaction of the engineer-in-charge.
Providing and laying in position cement concrete 1:5:10 (1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of centering and shuttering complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centering , shuttering in All work up to plinth level, complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position cement concrete 1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and curing complete excluding the cost of centering and shuttering for all work up to plinth level complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed, bkocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering & finishing cpmplete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying in position reinforced cement concrete 1:1.5:3 (1cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size) and curing complete in :
All work up to plinth level excluding the cost of centering, shuttering & reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto all level, excluding the cost of centering, shuttering and reinforcement complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
In beams, suspended floors, roofs having slope upto 15 degree landing , balconies, shelves, chajjas, lintel , bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level , excluding the cost of centeringb , shuttering , finishing and reinforcemen with 1:1.5:3 ( 1 cement : 1.5 coarse sand:3 graded stone aggregates 20 mm nominal size) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing cement concrete lining 15 cm thick or less for irrigation channels, using cement concrete 1:2:4 (1 cement2 sand :4 stone aggregate 20 mm nominal size) in:
Bed complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Side slopes complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and Laying Stone/ Boulder filling behind the Retaining wall , also under floor and upstream of i/ gallery/ under floor etc.complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Cement concrete flooring 1:2:4(1 cement :2 coarse sand :4 graded stone aggregates) finished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
20 mm cement plaster of mix, complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Dismantling of old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 mtrs.
Providing Mild steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing CI Sluice Valve of following dia & class of Leader / Kartar / Kirloskar make with MS Flange of Table 5 as per IS 6392-1971 & welding of MS Flanges in two layers on both faces complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
80 mm dia, PN-1.0 (10.2 Kg/cm²)
150 mm dia, PN-1.0 (10.2 Kg/cm²)
Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS:16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ± 2%) Zinic+PVC coated, Mesh wire diameter 2.7/3.7mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing, laying, jointing , commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239: 2004 of 150 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
Providing, laying, jointing , commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239: 2004 of 100 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
Providing, laying, jointing , commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239: 2004 of 80 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
Providing, laying, jointing , commissioning and testing in trenches (to level or grade) GMS tubes confirming to IS : 1239: 2004 of 25 mm dia, medium class with all necessary fittings conforming to IS specification capable to withstand the required hydraulic test pressure as per IS code in random length of 6.00 mtrs. including flushing , cleaning and hydraulic testing of pipe complete in all respect within all leads and lifts and to the entire satisfaction of Engineer-in-Charge.
Providing circumferencial Butt welded joints by electrical arc welding to GMS tubes confirming to IS : 1239: 2004 of 150 mm dia,welded in requisite numbers of weld runs to make the joint leak proof so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
Providing circumferencial Butt welded joints by electrical arc welding to GMS tubes confirming to IS : 1239: 2004 of 100 mm dia,welded in requisite numbers of weld runs to make the joint leak proof so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - Citojet / ESAB make conforming to IS 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
Providing, laying, jointing, commissioning & testing in trenches HDPE pipes of following diameters & classes as per IS 4984 (1995) and jointing the pipes with push type compression joints by hydraulically operated machines, butt fussion welding & electro fusion welding machines i/c necessary fittings, bends, tees, unions, flanges, collars & reducers etc. confirming to IS 8360 & IS 8008 with latest ammendments & shall be provided as per site conditions. Flanging of the pipes shall be made as & where required. Jointing shall be confirming to IS code 8008 & IS 7634, stub ends will be welded on pipes & MS flange shall be provided with slip on covered by epoxy coating/plastic powder. The flange should be confirm to ANSI B 16.5 with necessary nuts & bolts. All manufacturing maerial used shall be in accordance to IS 4427-2007 (latest revision) with 100 % virigin pre-compounded or natural PE resin. Jointing shall be complete in all respects i/c testing at site upto entire satisfaction of the Engineer-in-Charge. For Approved makes as per the list Enclosed in bidding Document Page No. CF-8.
90mm Dia (PN-6,PE-100)
110mm Dia (PN-6,PE-100)
Providing and fixing of 63 mm hydrant with main or submain line including HDPE Riser 63 mm double threaded PN-10.0, 63 mm PP ball valve, bend, male female coupler threaded PN-10.0, service saddle PN-10.0 and elbow bend with steel clamp complete in all respect and jointing by butt fusion process (as per requirement of main & sub main line) complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and Fixing Puddle Collar 100mm Dia complete with all necessary fitting & accessories to the entire satisfaction of the Engineer-in-Charge.
Providing and Fixing Puddle Collar 80mm Dia complete with all necessary fitting & accessories to the entire satisfaction of the Engineer-in-Charge.
Cutting of MS Plate permanent engraving marked scale/calibration on the plate and fixed at the site of work.
Providing and Fixing Valve Box for Hydrant Size 12'' (Rectangular) complete in all respects and up to entire satisfaction of the Engineer-in-Charge. 12'' Box
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Writing new letters and figures of any shade with synthetic enamel black or any other approved colour to give an even shade as per drawings and technical specifications clause 1701 in English and roman, hyphen, commas and the like not to be measured and paid complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Finishing with epoxy paint (two or more coats) at all locations prepared on steel work and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete in all respect within all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
ANKUSH CHAUDHARY
Sandeep Kumar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .