Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAdmitted-Fee/PreQual/Technical/Finance | ₹6.1 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹6.1 L+₹1,220 (0.20%)Admitted-Fee/PreQual/Technical/Finance | ₹6.1 L+₹1,220 (0.20%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹6.7 L+₹54,780 (8.96%)Admitted-Fee/PreQual/Technical/Finance | ₹6.7 L+₹54,780 (8.96%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹6.8 L+₹72,819 (11.9%)Admitted-Fee/PreQual/Technical/Finance KUNZER KUNZER TANGMARG BARAMULLA JAMMU KASHMIR 193401 | BUDGAM | JAMMU AND KASHMIR | 193401 | ₹6.8 L+₹72,819 (11.9%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | L5₹7.2 L+₹1.1 L (17.9%)Admitted-Fee/PreQual/Technical/Finance 12 BUMHAMA KUPWARA KUPWARA BUMHAMA KUPWARA KUPWARA JAMMU KASHMIR 193222 | KUPWARA | JAMMU AND KASHMIR | 193222 | ₹7.2 L+₹1.1 L (17.9%) | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | NARWARI ELECTRICALS L9 | IMPLA GENERAL SUPPLIERS L8 | GULMARG ELECTRICALS AND SUPPLIERS L2 | DAR ELECTRICALS L6 | M/S BHAT ELECTRICAL & ELECTRONICS L4 | m/s rahmiya electricals L3 | AFTAB ELECTRONICS L7 | WAZA ELECTRICALS L1 | KHAN AND SONS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433KV, 63 kVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2 of BIS and with LV Cable Box having detachable Aluminium Gland plate. Transformer should have arrangement for vertical Take off | 1 | No. | 1,65,000 ₹1,65,000 | 1,40,000 ₹1,40,000 Lowest | 1,45,000 ₹1,45,000 | 2,30,000 ₹2,30,000 | 1,70,000 ₹1,70,000 | 1,50,000 ₹1,50,000 | 2,00,000 ₹2,00,000 | 1,70,000 ₹1,70,000 | 1,70,000 ₹1,70,000 |
| 2.00 | Supply , Transportation and errection of 9MTR long ST Poles (410 SP-33) completely errected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit. (as per REC Standard) | 12 | No. | 19,899 ₹2,38,788 | 20,000 ₹2,40,000 | 17,000 ₹2,04,000 Lowest | 20,000 ₹2,40,000 | 18,000 ₹2,16,000 | 17,000 ₹2,04,000 Lowest | 20,000 ₹2,40,000 | 18,000 ₹2,16,000 | 18,500 ₹2,22,000 |
| 3.00 | Supply, Transportation and errection of 8MTR long ST Poles (410-SP 15) completely erected in the pit of 1/5th of the pole length including excavation and back filling of the pole pit . (as per REC standard) | 3 | No. | 13,000 ₹39,000 | 12,500 ₹37,500 | 12,500 ₹37,500 | 16,000 ₹48,000 | 11,000 ₹33,000 Lowest | 13,000 ₹39,000 | 13,000 ₹39,000 | 14,000 ₹42,000 | 15,000 ₹45,000 |
| 4.00 | Supply,Carraige upto site,, laying ,stringing, tensioning , binding of ACSR Weasel Conductor, (30mm2 ACSR Conductor) as per REC standard. | 0.1 | Kms | 42,500 ₹4,250 | 30,000 ₹3,000 | 32,000 ₹3,200 | 50,000 ₹5,000 | 1,000 ₹100 Lowest | 35,000 ₹3,500 | 30,000 ₹3,000 | 35,000 ₹3,500 | 35,000 ₹3,500 |
| 5.00 | Supply,Carraige upto site,, laying and commissioning of, 70 mm² AB (HT) Cable (3 x 70 + 1x95 insulated)mm² XLPE(11 kV, 3C + Earth) | 0.4 | Kms | 14,99,000 ₹5,99,600 | 12,00,000 ₹4,80,000 | 1,10,000 ₹44,000 | 20,000 ₹8,000 | 3,00,000 ₹1,20,000 | 1,20,000 ₹48,000 | 5,70,000 ₹2,28,000 | 1,400 ₹560 Lowest | 2,50,000 ₹1,00,000 |
| 6.00 | Supply, transportation and fixing of GI Channel /Angle Iron for Cross Arms, Braces, Transformer Belt, F-Top, Collers etc for Sub Station and poles (Complete Job including Nuts & Bolts and Washers) | 490 | Kgs | 145 ₹71,050 | 130 ₹63,700 | 120 ₹58,800 | 350 ₹1,71,500 | 100 ₹49,000 Lowest | 130 ₹63,700 | 110 ₹53,900 | 115 ₹56,350 | 135 ₹66,150 |
| 7.00 | Supply and fixing of Gapless surge arrestor, 9 KV, 10KA , LA station Type including nuts and bolts, washers, clamps etc. complete job as per REC standard. (Drilling of holes prohibited) | 1 | Set | 4,500 ₹4,500 | 2,000 ₹2,000 | 3,500 ₹3,500 | 2,000 ₹2,000 | 2,000 ₹2,000 | 9,000 ₹9,000 | 1,300 ₹1,300 Lowest | 2,000 ₹2,000 | 7,000 ₹7,000 |
| 8.00 | Supply and fixing of 11KV G.O set (AB Switch 3-phase,3 -pole,200A) including nuts and bolts, washers, clamps etc. complete job as per REC standard. (Drilling of holes prohibited) | 1 | Set | 10,599 ₹10,599 | 8,500 ₹8,500 | 6,000 ₹6,000 Lowest | 10,000 ₹10,000 | 14,000 ₹14,000 | 10,000 ₹10,000 | 8,500 ₹8,500 | 10,000 ₹10,000 | 10,000 ₹10,000 |
| 9.00 | Supply and fixing of lt Fuse Set. complete job as per REC standard. (Drilling of holes prohibited) | 1 | Set | 4,000 ₹4,000 | 6,000 ₹6,000 | 3,500 ₹3,500 | 3,000 ₹3,000 | 2,000 ₹2,000 Lowest | 5,000 ₹5,000 | 3,500 ₹3,500 | 3,000 ₹3,000 | 8,000 ₹8,000 |
| 10.00 | Supply, Carriage up to site, Installation, testing and Commissioning of LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp
MCCB 3P 16 kA 1 No.s for Outgoing Circuits | 1 | No. | 24,500 ₹24,500 | 35,000 ₹35,000 | 32,000 ₹32,000 | 2,000 ₹2,000 Lowest | 30,000 ₹30,000 | 40,000 ₹40,000 | 35,000 ₹35,000 | 50,000 ₹50,000 | 20,000 ₹20,000 |
Tender Value
₹11.1 L
EMD Value
₹22,220
Closing Date
11 Aug 2026, 2:00 pmClosed
Assistant executive Engineer KPDCL Tangmarg
KPDCL Tangmarg
Installation of Transformer at Gojri Mohalla Wailoo under PRI Grants for the year 2026-27
2026_PDD_317230_1
E-NIT No.SSDT/09 of 2026-27 dated 21.07.2026
Open Tender
Electrical Works
Turn-key
30 days
Gojri Mohalla Wailoo
Please refer Tender documents.
4 documents required · 4 mandatory
₹650
Treasury Officer
₹22,220
24 Aug 2026
22 Jul 2026
12 Aug 2026
22 Jul 2026
11 Aug 2026
23 Jul 2026
22 Jul 2026 - 23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433KV, 63 kVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2 of BIS and with LV Cable Box having detachable Aluminium Gland plate. Transformer should have arrangement for vertical Take off | 1 | No. | - | - |
| 2 | Supply , Transportation and errection of 9MTR long ST Poles (410 SP-33) completely errected in the pit of 1/6th of the pole length including excavation and back filling of the pole pit. (as per REC Standard) | 12 | No. | - | - |
| 3 | Supply, Transportation and errection of 8MTR long ST Poles (410-SP 15) completely erected in the pit of 1/5th of the pole length including excavation and back filling of the pole pit . (as per REC standard) | 3 | No. | - | - |
| 4 | Supply,Carraige upto site,, laying ,stringing, tensioning , binding of ACSR Weasel Conductor, (30mm2 ACSR Conductor) as per REC standard. | 0.9 | Kms | - | - |
| 5 | Supply,Carraige upto site,, laying and commissioning of, 70 mm² AB (HT) Cable (3 x 70 + 1x95 insulated)mm² XLPE(11 kV, 3C + Earth) | - | Kms | - | - |
| 6 | Supply, transportation and fixing of GI Channel /Angle Iron for Cross Arms, Braces, Transformer Belt, F-Top, Collers etc for Sub Station and poles (Complete Job including Nuts & Bolts and Washers) | 490 | Kgs | - | - |
| 7 | Supply and fixing of Gapless surge arrestor, 9 KV, 10KA , LA station Type including nuts and bolts, washers, clamps etc. complete job as per REC standard. (Drilling of holes prohibited) | - | Set | - | - |
| 8 | Supply and fixing of 11KV G.O set (AB Switch 3-phase,3 -pole,200A) including nuts and bolts, washers, clamps etc. complete job as per REC standard. (Drilling of holes prohibited) | - | Set | - | - |
| 9 | Supply and fixing of lt Fuse Set. complete job as per REC standard. (Drilling of holes prohibited) | - | Set | - | - |
| 10 | Supply, Carriage up to site, Installation, testing and Commissioning of LT Distribution Box for 63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp
MCCB 3P 16 kA 1 No.s for Outgoing Circuits | - | No. | - | - |
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.86 MB
Tendernotice_2.pdf
PDF • 18.30 MB
BOQ_1038681.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .