Loading…
Loading…
Tender Value
₹4.8 L
EMD Value
₹9,602
Closing Date
9 Sept 2026, 6:00 pm
Superintending Engineer, North Campus of IIT M
O/o Superintending Engineer, North Campus of IIT Mandi, Kamand HP-175075
Servicing and Maintenance of AHU/FCU Units and Chemical Treatment of Water for Hot Water Generator System and allied piping network for Academic Buildings at North Campus, IIT Mandi
2026_IITMD_922947_1
IIT Mandi (CW)/SE-1824/2026-27/1598-1600 dated 19-08-2026.
Open Tender
Electrical Works
Item Rate
75 days
North Campus of IIT Mandi
Please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹9,602
20 Aug 2026
20 Aug 2026
11 Sept 2026
20 Aug 2026
9 Sept 2026
20 Aug 2026
20 Aug 2026 - 9 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing comprehensive cleaning and servicing of Air Handling Unit (AHU)/ Fan Coil Units of up to 200 CFM ( Heating Only) including opening of access panels, thorough cleaning of cooling/heating coils using approved HVAC coil cleaning chemicals, removal of accumulated dust, dirt and debris from coil fins, cleaning of drain tray, condensate drain line, filters, blower/impeller, motor exterior and internal AHU casing, checking of belts, bearings, dampers, electrical connections and other AHU components for proper functioning, reassembly of all components after cleaning, testing and commissioning of AHU after servicing, and submission of inspection report indicating any defects, repairs or replacements required. The scope shall include all labour, tools, coil cleaning chemical, transportation and safety equipment complete as required and as directed by Engineer-in-Charge. No spare parts is included in this item. | 124 | Each | - | - |
| 2 | Providing comprehensive cleaning and servicing of Air Handling Unit (AHU)/ Fan Coil Units of above 200 CFM to 800 CFM ( heating / cooling ) including opening of access panels, thorough cleaning of cooling/heating coils using approved HVAC coil cleaning chemicals, removal of accumulated dust, dirt and debris from coil fins, cleaning of drain tray, condensate drain line, filters, blower/impeller, motor exterior and internal AHU casing, checking of belts, bearings, dampers, electrical connections and other AHU components for proper functioning, reassembly of all components after cleaning, testing and commissioning of AHU after servicing, and submission of inspection report indicating any defects, repairs or replacements required. The scope shall include all labour, tools, coil cleaning chemical, transportation and safety equipment complete as required and as directed by Engineer-in-Charge. No spare parts is included in this item. | 11 | Each | - | - |
| 3 | Providing comprehensive cleaning and servicing of Air Handling Unit (AHU)/ Fan Coil Units of above 800 to 4000 CFM (both heating & cooling ) including opening of access panels, thorough cleaning of cooling/heating coils using approved HVAC coil cleaning chemicals, removal of accumulated dust, dirt and debris from coil fins, cleaning of drain tray, condensate drain line, filters, blower/impeller, motor exterior and internal AHU casing, checking of belts, bearings, dampers, electrical connections and other AHU components for proper functioning, reassembly of all components after cleaning, testing and commissioning of AHU after servicing, and submission of inspection report indicating any defects, repairs or replacements required. The scope shall include all labour, tools, coil cleaning chemical, transportation and safety equipment complete as required and as directed by Engineer-in-Charge. No spare parts is included in this item. | 17 | Each | - | - |
| 4 | Providing comprehensive cleaning and servicing of Air Handling Unit (AHU) Units of above 4000 to 6900 CFM (both heating & cooling ) including opening of access panels, thorough cleaning of cooling/heating coils using approved HVAC coil cleaning chemicals, removal of accumulated dust, dirt and debris from coil fins, cleaning of drain tray, condensate drain line, filters, blower/impeller, motor exterior and internal AHU casing, checking of belts, bearings, dampers, electrical connections and other AHU components for proper functioning, reassembly of all components after cleaning, testing and commissioning of AHU after servicing, and submission of inspection report indicating any defects, repairs or replacements required. The scope shall include all labour, tools, coil cleaning chemical, transportation and safety equipment complete as required and as directed by Engineer-in-Charge. No spare parts is included in this item. | 6 | Each | - | - |
| 5 | Supply, dosing, circulation and application of approved descaling chemical for removal of scale, silica and hardness deposits from Hot Water Generator system (Having 2 X 600 KW Hot water Generator), including flushing and cleaning of all piping network in A9, A10, A11, A12, A13, A14, A16 blocks, complete as required and as directed by Engineer-in-Charge. | 80 | Ltr. | - | - |
| 6 | Supply and dosing of oxygen scavenger chemical in hot water system (Having 2 X 600 KW Hot water Generator), complete as required and directed by Engineer-in-Charge. | 80 | Ltr. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.74 MB
BOQ_969881.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].