Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹26.0 L+₹1.0 L (4.03%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹28.9 L+₹3.8 L (15.4%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹29.1 L+₹4.0 L (16.2%)Rejected-Finance H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 5 | L5₹33.1 L+₹8.0 L (32.1%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| Sl No | Description | Qty | Unit | om sai enterprises L3 | MAYUR ELECTRIC SERVICES L5 | Srinivash Engineers L1 | RAMESH CONSTRUCTION COMPANY L4 | Sri Surya Enterprises L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance and servicing to switchgear (VCB/RMU) once in year and 4 visits to inspect / attend VCB complaints on demand/fault under AMC period as specified by Engr-In-charge and duly carring out servicing, overhauling, calibration by using suitable test kits, and cleaning the switch gear terminals/moving parts of electric / mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom / Schneider) of any technical specification of 11 KV grade VCB current rating 400/630/800/1250 Amps (incomings of MAFI 1 & 2) Including for checking, examining complete VCB in terms of electrical and mechanical side in all respects after complete with facilitated automatic operating features and review the control switches with wiring and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory complete all as specified and as directed. | 4 | Each Job | 15,000 ₹60,000 | 15,000 ₹60,000 | 4,000 ₹16,000 Lowest | 16,000 ₹64,000 | 5,000 ₹20,000 |
| 2.00 | All as per Item No 01 above here in before but Comprehensive maintenance and servicing to switchgear of out going HT 11 KV grade switch gears (VCB/RMU's of ay type is as one unit) once in year and visits shall be on complaints/defects under maint period as complete all as specified and as directed.
Note for Ser item No 1 & 2 above :-
(i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in the item rate.
(ii) Servicing shall be got carried out thorugh a approved agency of any state/Central govt CEI (chief electrical Inspectorate)
(iii) Engineer shall be consider repair/servicing duly reference taken from OEM drawings and tech specifications and service engineer will submit a service report and calibration certificate for each VCB.
(iv) Any minor item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included in the quoted rates.
(v) Failing attend the lodged complaint of any mode within 24 Hours will imposed penalty of Rs. 1000 / fault for each day cumulatively and same shall be deducted from his dues. | 13 | Each Job | 6,500 ₹84,500 | 7,500 ₹97,500 | 4,000 ₹52,000 Lowest | 6,000 ₹78,000 | 5,000 ₹65,000 |
| 3.00 | Tracing/tracing and pointing out fault in 11KV underground cable any size with the help of fault tracing machine and rectify the fault by making joints of any type and size as specified and directed to restore the supply complete all as specified and as directed.
Note:-
(i) Joint kit shall be measured and paid separately.
(ii) Earth work shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width given in SSR for each size of cable.
(iii) All other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted.
(iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account.
(v) Cable required, if any shall be measured and paid for separately.
(vi) Fault & location thereof shall be traced within 12 hours of intimation by the Engineer-in-Charge. failing shall be imposed penalty of Rs 500/fault for each day cumulatively and same shall be deducted from his dues. | 8 | Each Fault | 10,000 ₹80,000 | 15,000 ₹1,20,000 | 10,000 ₹80,000 | 9,000 ₹72,000 Lowest | 11,000 ₹88,000 |
| 4.00 | Supply only multi function digital panel meter (Micom relay) having the parameters the HT voltage,current, frequency, power factor , KVA, KVAR and short CCT current/fault level currenct sensor measurements etc suitable for operating Voltage 24/110/230 volts complete all as specified and as directed.
Make : L&T (Micom relay) / CADLE / Socomech | 2 | Each | 12,000 ₹24,000 Lowest | 18,000 ₹36,000 | 13,000 ₹26,000 | 17,000 ₹34,000 | 13,000 ₹26,000 |
| 5.00 | Supply only potential transformer model ECS11J or suitable to existing and conforming to IS 3156-1992, insulation class 'B' suitable for existing breakers complete all as specified and as directed.
Make :- Schneider or equvalent in AREVA/SIEMENS/ABB/Megawin | 2 | Set of 3 | 19,000 ₹38,000 | 3,500 ₹7,000 | 900 ₹1,800 Lowest | 1,600 ₹3,200 | 900 ₹1,800 Lowest |
| 6.00 | Supply only trip circuit supervision relay VAX30-34V model No.VAX31ZG8043FCH make- Alstom including taking out old U/S relay complete all as specified and as directed.
Make :- Alstom or equvalent in L&T/MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider | 2 | Each | 3,600 ₹7,200 | 7,500 ₹15,000 | 1,100 ₹2,200 Lowest | 1,700 ₹3,400 | 1,100 ₹2,200 Lowest |
| 7.00 | Supply only Gear box of 11 KV HT VCB panel including taking out old U/S Gear box complete all as specified and as directed.
Make :- Magawin or equivalent in AREVA / SIEMENS / ABB / Schenider | 2 | Each | 12,000 ₹24,000 | 12,000 ₹24,000 | 1,500 ₹3,000 Lowest | 17,000 ₹34,000 | 1,500 ₹3,000 Lowest |
| 8.00 | Supply only multi function meter model EN 8400 having the parameters the HT voltage,current, frequency, power factor , KVA, KVAR etcsuitable for existing RMU complete all as specified and as directed.
Make : Elmeasure or equivalent | 2 | Each | 5,500 ₹11,000 | 7,900 ₹15,800 | 3,500 ₹7,000 Lowest | 7,000 ₹14,000 | 3,500 ₹7,000 Lowest |
| 9.00 | Supply only single phase under voltage or over voltage relay 20/110 V or 82/264V suitable for existing breakers complete all as specified and as directed.
Make : L&T or equvalent in MEGHAWIN / AREVA / SIEMENS / ABB / Schenider | 2 | Each | 7,500 ₹15,000 | 11,000 ₹22,000 | 5,000 ₹10,000 Lowest | 10,000 ₹20,000 | 5,000 ₹10,000 Lowest |
| 10.00 | Supply only single phase over current or earth fault relay 20/110 V or 82/264V suitable for existing breakers complete all as specified and as directed.
Make : L&T or equvalent in MEGHAWIN / AREVA / SIEMENS / ABB / Schenider | 2 | Each | 6,000 ₹12,000 | 12,000 ₹24,000 | 5,000 ₹10,000 Lowest | 8,500 ₹17,000 | 5,000 ₹10,000 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
4 Aug 2025, 6:00 pmClosed
CWE (AF) Secunderabad
CWE (AF) Secunderabad
COMPREHENSIVE MAINTENANCE AND REPAIRS TO HT 11KV GRADE MAFI I AND II SUB STATIONS AND MAINTENANCE TO HT DISTRIBUTION LINES, TRANSFORMERS, HT VCBs AND ALLIED WORKS UNDER GE (AF) BIDAR
2025_MES_718900_1
85654/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Bidar
₹70,000
Yes
28 Aug 2025
7 Jul 2025
6 Aug 2025
7 Jul 2025
4 Aug 2025
21 Jul 2025
7 Jul 2025 - 17 Jul 2025
Amount
Comprehensive maintenance and servicing to switchgear (VCB/RMU) once in year and 4 visits to inspect / attend VCB complaints on demand/fault under AMC period as specified by Engr-In-charge and duly carring out servicing, overhauling, calibration by using suitable test kits, and cleaning the switch gear terminals/moving parts of electric / mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM and incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to VCB/protection relay by disconnecting, opening of indoor/out door type VCB (Make : Crompton / Megawin / Yamuna Denson / ABB Ltd, Alsthom / Schneider) of any technical specification of 11 KV grade VCB current rating 400/630/800/1250 Amps (incomings of MAFI 1 & 2) Including for checking, examining complete VCB in terms of electrical and mechanical side in all respects after complete with facilitated automatic operating features and review the control switches with wiring and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the VCB complete in all respects upto serviceablility state of switch gear to satisfactory complete all as specified and as directed.
All as per Item No 01 above here in before but Comprehensive maintenance and servicing to switchgear of out going HT 11 KV grade switch gears (VCB/RMU's of ay type is as one unit) once in year and visits shall be on complaints/defects under maint period as complete all as specified and as directed. Note for Ser item No 1 & 2 above :- (i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in the item rate. (ii) Servicing shall be got carried out thorugh a approved agency of any state/Central govt CEI (chief electrical Inspectorate) (iii) Engineer shall be consider repair/servicing duly reference taken from OEM drawings and tech specifications and service engineer will submit a service report and calibration certificate for each VCB. (iv) Any minor item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included in the quoted rates. (v) Failing attend the lodged complaint of any mode within 24 Hours will imposed penalty of Rs. 1000 / fault for each day cumulatively and same shall be deducted from his dues.
Tracing/tracing and pointing out fault in 11KV underground cable any size with the help of fault tracing machine and rectify the fault by making joints of any type and size as specified and directed to restore the supply complete all as specified and as directed. Note:- (i) Joint kit shall be measured and paid separately. (ii) Earth work shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width given in SSR for each size of cable. (iii) All other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted. (iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account. (v) Cable required, if any shall be measured and paid for separately. (vi) Fault & location thereof shall be traced within 12 hours of intimation by the Engineer-in-Charge. failing shall be imposed penalty of Rs 500/fault for each day cumulatively and same shall be deducted from his dues.
Supply only multi function digital panel meter (Micom relay) having the parameters the HT voltage,current, frequency, power factor , KVA, KVAR and short CCT current/fault level currenct sensor measurements etc suitable for operating Voltage 24/110/230 volts complete all as specified and as directed. Make : L&T (Micom relay) / CADLE / Socomech
Supply only potential transformer model ECS11J or suitable to existing and conforming to IS 3156-1992, insulation class 'B' suitable for existing breakers complete all as specified and as directed. Make :- Schneider or equvalent in AREVA/SIEMENS/ABB/Megawin
Supply only trip circuit supervision relay VAX30-34V model No.VAX31ZG8043FCH make- Alstom including taking out old U/S relay complete all as specified and as directed. Make :- Alstom or equvalent in L&T/MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider
Supply only Gear box of 11 KV HT VCB panel including taking out old U/S Gear box complete all as specified and as directed. Make :- Magawin or equivalent in AREVA / SIEMENS / ABB / Schenider
Supply only multi function meter model EN 8400 having the parameters the HT voltage,current, frequency, power factor , KVA, KVAR etcsuitable for existing RMU complete all as specified and as directed. Make : Elmeasure or equivalent
Supply only single phase under voltage or over voltage relay 20/110 V or 82/264V suitable for existing breakers complete all as specified and as directed. Make : L&T or equvalent in MEGHAWIN / AREVA / SIEMENS / ABB / Schenider
Supply only single phase over current or earth fault relay 20/110 V or 82/264V suitable for existing breakers complete all as specified and as directed. Make : L&T or equvalent in MEGHAWIN / AREVA / SIEMENS / ABB / Schenider
Supply only Tripping coil DC 24/110 volts suitable for existing breakers complete all as specified and as directed. Make : MEGHAWIN / AREVA / SIEMENS / ABB / Schenider
Supply only Closing coil DC 24/110 volts suitable for existing breakers complete all as specified and as directed. Make : MEGHAWIN / AREVA / SIEMENS / ABB / Schenider
Supply only Spring charge motor 1.5 KW single phase for functional of HT VCB suitable for existing makes complete all as specified and as directed. Make : MEGHAWIN / AREVA / SIEMENS / ABB / Schenider
Supply only current transformer suitable for existing breakers complete all as specified and as directed. Make :- Megawin or equvalent in AREVA / SIEMENS / ABB / Schenider
Supply only female & male contact made out of copper with silver coating type suitable for existing HT 11 KV breakers complete all as specified and as directed.
Supply only cast resin bush unit of suitable for existing HT 11 KV breakers along with copper studd duly coated with sliver plate for fixing of 11 KV bus bars along with suitable nut bolts and watchers complete all as specified and as directed.
Supply only moving arm unit (male & female) type suitable for existing HT 11 KV breakers complete all as specified and as directed.
Supply only HT barrel fuse 2 Amps suitable for 11 KV potential transformer of existing makes conforming to IS complete all as specified and as directed.
Supply only HT barrel fuse 32 Amps Din type suitable for existing HT 11 KV breakers conforming to IS complete all as specified and as directed.
Supply only HT barrel fuse 32 Amps BS type suitable for existing HT 11 KV breakers conforming to IS complete all as specified and as directed.
Taking down old unserviceable relay of any type from VCB breaker and supply and fix microprocessor based numerical relay with local display & communication port on IEC 61850 protocol comprising of IDMT/Ins 30/C+ E/F (50,51,50N,51N) complete all as specified and as directed. Make: ABB model REJ 601 / ALSTOM / ABB / ASHIDHA
Taking down old unserviceable relay of any type from VCB breaker and supply and fix microprocessor based numerical relay with local display & communication port on IEC 61850 protocol comprising of IDMT/Ins 30/C+ E/F (50,51,50N,51N) complete all as specified and as directed. Make: ABB model REF 651 / ALSTOM/ABB / ASHIDHA
Taking down of HT XLPE/ PVC UG cable 11000 V grade ,3 core of any size/dia up to 240 Sqmm from the trenches along complete all as specified and as directed.
Relaying of old serviceable HT XLPE/ PVC UG cable 11000 V grade ,3 core of any size/dia up to 240 Sqmm from the trenches along complete all as specified and as directed.
S&F for XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3 core, 11000 volts, grade of the size 240 Sqmm complete all as specified and as directed.
All as per item no 25 above here-in-before but of size 185 Sqmm complete all as specified and as directed.
All as per item no 25 above here-in-before but of size 120 Sqmm complete all as specified and as directed.
All as per item no 25 above here-in-before but of size 95 Sqmm complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 m in depth but not exceeding 3 mtr in hard soil complete all as specified and as directed.
Supply and laying unreinforced pre cast concrete cable cover class HV type 1 flat size 300 x 180 x 40 mm for cable protection complete all as specified and as directed.
Material and labour for returning and filling of trenches in two parts complete all as specified and as directed :- (i) using riddled soil obtained from excavated soil up to depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable. (ii) refilling the trench of remaining depth with normal excavated soil all as specified and as directed. Note: Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS-1255-1983 and refilling in trenches by adding stone crushed sand as in cable cushioning under relevant items of the schedule.
Supply and spreading crushed stone sand in trenches for cushioning of under ground cable all as directed by Engr-in-Charge at site complete all as specified and as directed. Note:- (i) Only punned thickness 18 cm will be measured and paid. (ii) supplied crushed stone sand shall be mixing with separated riddled soil as directed and the rates shall be deemed to include in quoted rates.under relevant items of the schedule.
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and as directed.
Relaying old serviceable unreinforced pre cast concrete cable cover taken out from the trenches complete all as specified and as directed.
Disconnection & Removing the unserviceable steel tubular poles and Supply & erect Steel tubular swaged poles 11.00 metres long ISI marked complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 complete all as specified and as directed. Note:- Excavation, PCC, returning filling, pole painting and numbering will be measured and paid sepertely under relevant of items of Sch A.
M&L plain cement concrete in foundations, filling and mass concrete Type C2 1:3:6 using 40 mm graded aggregate complete all as specified and as directed.
M&L plain cement concrete in coping, filling and mass concrete Type B1 1:2:4 using 20 mm graded aggregate complete all as specified and as directed.
Disconnection and removing the unserviceable earth conductor and S&F earth continuity conductor 25x4 mm galvanised iron strip buried in ground / fixed on pole / drawn in 40mm dia light grade GI pipe complete all as specified and as directed.
S&F for indoor type jointing kit heat shrinakable for 11KV grade UG cable end termination with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of size 240 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
All as per item no 40 above here-in-before but of size 120 to 185 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
All as per item no 40 above here-in-before but of size 95 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
M & L for outdoor type ,jointing kit,heat shrinakable for 11KV grade UG cable end termination with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of size 240 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
All as per item no 43 above here-in-before but of size 120 to185 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
All as per item no 43 above here-in-before but of size 95 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
S&F for outdoor type Straight through, Jointing kit, heat shrinakable for 11KV grade UG cable with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of of size 240 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
All as per item no 46 above here-in-before but of size120 to 185 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
All as per item no 46 above here-in-before but of size 95 Sqmm complete all as specified and as directed. Make:- Densons/ M-Seal/ Birla-3M/ CCI
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick, width not less than 1 mtr for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) IEC/BS EN 61111: 2009 BIS/ERDA/CPRI approved suitable for electrical shock safety complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) IEC/BS EN 61111: 2009 BIS/ERDA/CPRI approved suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Supply and fixing power pack unit of capacity 415/ 110 Volts 3 having 9 battyeries 12 volt x 90 AH phase and making necessary connection to PTs complete including taking out old U/S power pack unit complete all as specified and as directed. Make : Power pack
Supply and fixing power pack unit of capacity 230/12 Volts single phase and making necessary connection to PTs complete including taking out old U/S power pack unit complete all as specified and as directed. Make : Power pack
Supply and fixing power pack unit of capacity 230/24 Volts single phase and making necessary connection to PTs complete including taking out old U/S power pack unit complete all as specified and as directed. Make : Power pack
Servicing of Automatic Power Factor Correction (APFC) panel monthly of the capacity upto 200 KVAR complete comprising any type capacitors, APFC relay, MCCB, Cooling fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as specified and as directed. Note: (i) Major spares shall be measured and paid separetely. (ii) spares not inlcude in the schedule shall be provide by the contractor upto servicibility of the capacitor panel and satisfactory complete all as specified and as directed.
Supply only Heavy duty capacitors suitable for 300 kVAr, voltage grade 11 KV HT suitable to inbuilt in existing panel , having operating losses 0.35 W/kVAr complete all as specified and as directed.
Supply only APFC relay, 4 Stage, auto set function, having digital display complete all as specified and as directed.
Supply only APFC relay, 6 Stage, auto set function, having digital display complete all as specified and as directed.
Supply only thyristor switching module, suitable to 11 KV grade HT, 50 Hz, having high peaking inverse voltage suitable to exisiting panel complete all as specified and as directed.
Supply only capacitor duty contactor suitable for 11 KV grade, 50 Hz, 1 NO, suitable for kVAr rating up to 5 kVAr complete all as specified and as directed.
Supply only electronic time switch suitable for 900 KVAr capacitor panel voltage grade 11 KV HT complete all as specified and as directed.
Supply only LED indicator lamp (RED, YELLOW, GREEN) complete all as specified and as directed.
Supply only push button actuator with carrier any colour complete all as specified and as directed.
Supply only PVC Cooling fan for APFC panel 6” sweep as per sample complete all as specified and as directed.
Disconnecting cables from the transformer of capacity upto 1000 KVA of Resin/Dry open ventilated of voltage grade 11/.433 KV copper wound from the HT/LT side for servicing and insulating weaken winding using good quality varnish, tightning the terminals and cleaning the juction points with using suitable cleaning solutions and checking,calibration electrically/mechanically of the tansformer and configure the auto system without disturbing exising auto connectivity and reassembly the equipment by taking reference OEM drawings fixing/connect the same in all respects complete all as specified and as directed. Note:- (i) Minor spares like nut,bolt,lugs,terminal blocks, int wiring.fuse wires for repair/maint of the transformer is deemed to include in quoted rates. (ii) Major spares shall be measured and paid separately.
All as per item No 65 above here in before but transformer capacity 200 KVA, 3 phase 11/433 Volt of oil cooled with taking reference to OEM drawings complete all as specified and as directed.
Disconnecting the oil cooled servo voltage sabilizer of capcity 750 KVA of voltage grade 433 volt copper wound, taking out the connected cables for servicing and insulating the weaken winding using good quality varnish duly lifting from the chamber by taking care safety measures, tightning the terminals and cleaning the juction points with using suitable solutions and checking/calibration electrically/mechanically of and configure the auto system without disturbing exising auto connectivity and reassembly the equipment by taking reference OEM drawings and fixing/connect the same by dehydrate the oil upto measureable value obtain in all respects complete all as specified and as directed. Note:- (i) Minor spares like nut,bolt,lugs,terminal blocks, int wiring.fuse wires for repair/maint of the transformer is deemed to include in quoted rates. (ii) Major spares shall be measured and paid separately.
All as per item No 67 above here in before but Sevo voltage stabilizer of capacity upto 200 KVA of oil cooled with taking reference to OEM drawings complete all as specified and as directed.
All as per item No 67 above here in before but Isolation transformer of capacity upto 750 KVA of oil cooled of LT voltage grade 433 Volt 3 phase with taking reference to OEM drawings complete all as specified and as directed.
Supply and fixing in replacement of ceramic LV (primary/secondry) bushing complete with bushing stud (brass metal) for transformer of capacity up to 750 KVA complete all as specified and as directed.
Disconnection and removing the u/s PCB Unit from Servo stabilizer of capacity 750 KVA carefully and S&F new PCB unit complete of same size and capacity suitable for existing 750 KVA Servo Stabilizer complete all as specified and as directed.
Disconnection and removing the unserviceable servo motor unit along with shaft from the existing servo stabilizers (Oil / Air cooled ) carefully and replace same with the identical equivalent servo controlling unit of same size and capacity consisting of Reverseble synchronous motor with constant speed - Instant Start/Stop operates on single phase 230 V , 50Hz suitable for Voltage stabilizer of capacity 750 KVA(Oil Cooled) complete all as specified and as directed.
Disconnection and removing the u/s Main contactor carefully from voltage stabilizer 750 KVA and S&F new power contactor 3 POLE MNX 400, coil voltage 240 volt comprising of all accessories suitable for 750 KVA voltage stabilizer complete all as specified and as directed. Make : L&T or its equivalent Havells / C&S / Standard.
Taking down old unserviceable 11 KV insulated discharge rod and S&F in replacement of highly insulated FRP & Fiber glass industrial use earth telescopic discharge rod for 3 phase use having 3 Nos extendeble type upto 11 mtr height of capacity upto 66 KV HT lines complete all as specified and directed.
S&F for HT cable route indicator of RCC fabricated plate of size 50 cm x 30 cm of 5 cm thick duly colored with yellow and writing with black color letters on plate as "HT CABLE MES" and arrow mark to be colored and including laying of the route indicator as specified duly embedded in PCC 1 : 3 : 6 type C2 of size 20 x 20 x 30 cm block in trench over the cable route complete all as specified and directed.
Comprehensive maintenance and general servicing to LT switchgear ACB of capacity upto 1600 amps once in year duly carring out cleaning,overhauling, calibration by using suitable test kits, and cleaning the switch gear terminals/moving parts of electric/mechanically with suitable cleaning agents in all respects by taking care of reference drawings & specifications of OEM for automatic facilitated operating featuresand incl attending complaints on faults for the same on faulty/requirement/emergency calls of any type within the maintenance period and testing to ACB/protection relay by disconnecting, opening (Make : L&T,Crompton/CSS/ ABB Ltd/Scheneider) and review the control switches with wiring and replacement of minor spares like fuses, wires, terminals/blocks and removing/replace unserviceable / defective spare parts with new spares under relevent items, reassembling the ACB complete in all respects upto serviceablility complete all as specified and as directed. Note: (i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in the item rate. (ii) Servicing shall be got carried out thorugh a approved agency of any state/Central govt CEI (chief electrical Inspectorate) (iii) Engineer shall be consider repair/servicing duly reference taken from OEM drawings and tech specifications and service engineer will submit a service report and calibration certificate for each ACB. (iv) Any minor item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included in the quoted rates. (v) Failing attend the lodged complaint of any mode within 24 Hours will imposed penalty of Rs 500/fault for each day cumulatively and same shall be deducted from his dues.
Supply only Auxilary Switch (7 NO +7 NC) 14 way complete all as specified and as directed.
Supply only Under Voltage Trip Device cosisting of UVT Coil & control device fitted in ACB complete all as specified and as directed.
Supply only Shunt trip & Closing coil complete all as specified and as directed.
Supply only Vertical Connection Copper Adapter complete all as specified and as directed.
Supply only Trip Indication switch complete all as specified and as directed.
Supply only Spring Charged' indication switch complete all as specified and as directed.
Supply only Castle key lock ; Type: CKI - 1 complete all as specified and as directed.
Supply only Making current release / Instanteneous trip ; Type: CS-MCR - 1 complete all as specified and as directed.
Supply only Earth Fault Relay ,Type : EFR 1 complete all as specified and as directed.
Supply only Draw out mould Base(Cradle Side) type : 6D-16D complete all as specified and as directed.
Supply only Arcing Contacts ( Set of 1 No. Fixed & 1 No Moving) type 16 D complete all as specified and as directed.
Supply only Main Isolating Contacts ( Jaw contacts) ( Set of 1 No. Fixed & 1 No Moving) type 16 D complete all as specified and as directed.
Supply only Main fixed Contacts ( Upper Terminals) type 16 D complete all as specified and as directed.
Supply only Lower Terminals with fitting plates Contacts ( Upper Terminals) type : 16 D complete all as specified and as directed.
Supply only Circuit Terminals/Draw out terminals Type : 16D complete all as specified and as directed.
Supply only Main moving Contacts Assembly; type 16 D complete all as specified and as directed.
Supply only Single pole unit for 16 D complete all as specified and as directed.
Supply only Arc chutes; type 6 D - 16 D complete all as specified and as directed.
Supply only Charging motor (110 V AC/DC ) or (220 V AC/DC) Type: 6D- 16 D complete all as specified and as directed.
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal) & common salt Crystal and connected to copper earth strip20x3 mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 5 of SSR Part I of 1991 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box, including 20mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc complete all as specified and as directed. Note:- (i) Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items (ii) Qoted rate deemed to include the cost or excavation and earth work PCC Chamber, funnel cover etc.
Disconnection and removing the U/S / broken / bent Aluminium strip from the roof/ down conductors of the buildings and M&L for Aluminium strip of size 25x3.15 mm complete including cut to length and size to match the existing system and fixing the same to the wall / roof on suitable porcelin insulators along with fixing materials complete all as specified and as directed. Note : (i) Porcelin insulators will be measured and paid separately under the respective of the schedule (ii) Materials required for removing the u/s earth strips from any height the technical buildings (Apprx Upto 10 mtrs height) deemed to be included in the quoted rate.
All as per item No 97 here in above but Copper strip of size 20x3.15mm complete all as specified and as directed.
All as per item No 97 here in above but Copper strip of size 32x6mm complete all as specified and as directed.
M&L Tripod Earthing Complete with 3 numbers of Chemical earthing (maintenance free) using corrosion resistant earth electrode copper cladded, copper coating thickness of 250 microns, 17.20 mm dia, high tensile low carbon COPPER BONDED RODS WITH 99.9% with 25KA current discharge test from CPRI of length 3.0m as per UL 467, with suitable compressive coupler planted at depth not less than 3.0m of bore 100mm below gorund level and duly covered with low resistant superior conductive powdered non corrosive, highly hydrous earth enhancing material all as directed including connecting upto common bus bar grid of size 25 x 3 mm to achieve optimum low earth resistance on inspection/ testing complete all as specified and as directed. Note :- (a) The make shall be of manufactures as listed in particuler specification here-in-after. (b) The earthing shall comply to IS-3043 and the earth resistance shall be less than 1 ohm (c) The electrode shall carry UL marking and amanufacturer's name (d) The quoted rate shall also deemed to be included the following:- (i) Survey of earth resistance if required for testing of the earth shall be carried out along with departmental representative. (ii) The Grid point/ testing point shall be of 25 x 3mm copper bus bar of length 150mm mounted on porcelain insulators and enclosed in suitable enclosure of mild steel 2mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. (iii) The carbon based earth enhancement compound shall have very minimum resistance value (less than 0.12 Ohm) to keep the earth resistance at the lower level. The back fill compound shall be filled with highly conductive and eco friendly ground enhancing compound as per IEC 62561-7 shall not be less that 90KG per pit. (iv) Testing of earth shall be carried out alongwith the departmental representive and report shall be submitted. (v) The 35 Sqm single core copper cable PVC insulated for inter connection of earthing to equipment. The quoted rate shall deemed to include the cost of copper cable 35 Sqm up to 7.5 Mtr. (vi) Earthwork such as auguring and making good the surrounding area shall carried out in any type of soil. The bore hole shall be not less than 80mm dia and 3.0m deep from ground level. (vii) Earth termination clamps shall be provided to facilitate connection to equipment.
Supply, installation, testing & commissioning of Digital Grounding Device 240 kA 3 phase 4 wire portable type with resistance sensor built in low impedance equipment grounding and bonding system, provides 100% protection against Lightning surges, static charge, noises,ESD,EPR and eliminates abnormal electrical disturbances which enter from power and other service lines and ensuring clear bonding potential (earth to neutral voltage) less than 1.0 V having a digital 6 digit lightening surge counter, self-health visual status indicator with facility to monitor online input voltages & earth to neutral voltages pre-wired pulverulent body painted metal enclosure to be connected in parallel to the powersupply circuit, tested and certified from CPRI, MIL STD810G, IEC61000-6-1,IEC 61000-6-3, IEC 61643-11-2011 & confirming to ISO 9000 & ISO 14001-2015 & CE complete all as specified and as directed. Make : - Model: DSE-MII 3P4 240 of make DSS Digital Equipement protection Co. or equivalent model in Nextechno Gen Pvt ltd / Magnus Global Power solutions as approved by GE.
Supply, installation, testing & commissioning of Digital Grounding Device 120 kA 1 phase 3 wire portable type with resistance sensor built in low impedance equipment grounding and bonding system, provides 100% protection against Lightning surges, static charge, noises,ESD,EPR and eliminates abnormal electrical disturbances which enter from power and other service lines and ensuring clear bonding potential (earth to neutral voltage) less than 1.0 V having a digital 6 digit lightening surge counter, self-health visual status indicator with facility to monitor online input voltages & earth to neutral voltages pre-wired pulverulent body painted metal enclosure to be connected in parallel to the powersupply circuit, tested and certified from CPRI, MIL STD810G, IEC61000-6-1,IEC 61000-6-3, IEC 61643-11-2011 & confirming to ISO 9000 & ISO 14001-2015 & CE complete all as specified and as directed. Make : - Model: DSE-MII 1P3 120 of make DSS Digital Equipement protection Co. or equivalent model in Nextechno Gen Pvt ltd / Magnus Global Power solutions as approved by GE.
Supply only indicating lamp red,yellow,blue,green, white of operating voltage 24/110/230 volts including taking down u/s indicators complete all as specified and as directed. Make - Wipro / Bajaj / Havells
M&L for topping up and replacement of old transformer oil with new transformer oil in the existing transformer 11/0.433 for topup or achieve the required level after centrifuging by the centrifuging machine complete all as specified and as directed Make - Power Oil / Transol / GET
M & L for Silica Gel of Transformer including removing the unserviceable Silica gel and replace the same in serviceable breather in various locations all as directed at site complete all as specified and as directed.
Removing the unserviceable silica gel container and S& F Silica gel container (breather unit complete) suitable for existing transformers of any capacity upto 750 KVA complete all as specified and as directed.
M & L for Mild steel plates, plain or chequered, 5mm thick cut to shape and size to match the existing HT / LT cable ducts including provision of holes to accomodate the handles and painting the same with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Supply and fix mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including bolts, nuts, washers inclusive of one coat primer and two coats of painting including dismantling the unserveable one complete all as specified and as directed. Make - SAIL/ TISCO/ RINL/ Jindal Steel
M&L for stringing and fixing in position of ACSR conductor in OH line connections as per site requirement including provision of aluminium binding wire incl takingh down old US conductor of any type and size complete all as specified. Make - All-Ind/ ICC/ Bharat Conductors
Repairing and servicing (Oiling and greasing) of gang operated switch 11 KV vertical/Horizontal mounted and Including replacement of U/S spare parts with seviceable parts such as male,female links, earth wire, spring mechanism as required for smooth functioning of switch, testing for its proper operation complete all as specified and as directed.
Disconnecting and removing the unserviceable 11 KV Disc type insulator from HT poles and S&F Disc type insulator, porcelain, vitreous 145mm hight and 255mm dia ball and socket type, white, brown or green single disc assembly of 11000 Volts ISI Marked along with fixing material such as GI bolt, nut and washers etc complete all as specified and as directed. Make - BHEL/ Jayshree/WS Insulators.
Disconnecting and removing the unserviceable 11 KV Pin insulator from HT poles and S & F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 Volts ISI Marked along with fixing material such as GI bolt, nut and washers etc. complete all as specified and as directed. Make - BHEL/ Jayshree/WS Insulators.
Disconnecting & Removing the unserviceable GODO horizontal / vertical of capacity 400 A, 11 KV from the Two/four pole / six pole structure carefully and supply and fix gang operated air-break switch 400 A, 11 KV, triple pole, mounted on post insulator along with 25mm light grade GI tubing operating from operating mechanism from ground level of 12 insulators complete all as specified and as directed. Note: Cost of Jumper connections along with fixing material deemed to inclusive in the unit rate. Make - Pactil, Mumbai/ Southern Switchgear, Jaipuria Brothers/BHEL
All as per Item No 113 here-in-above but of capacity 200 Amps complete all as specified and as directed
Disconnecting and removing the unserviceable 11 KV Lightening arrester carefully from the 2/4/6 Pole structure and Supply & fix lightining arrester suitable for 11000 Volts of discharge capacity 65 Kilo Amp, 3 Phase including connecting of the same to the supply with necessary fixing materials such as nut bolt, washers etc. complete all as specified and as directed. Make - Oblum/BHEL/ GEC-ELPRO.
Disconnection and removing the unserviceable 11 KV Expulsion fuse single pole carefully from the 2/4/6 Pole structure and Supply & fixing Expulsion fuse single pole along with post insulators suitable for 11000 Volts, 50 A capacity including connecting of the same to the supply with necessary fixing materials such as Aluminium jumpers, Aluminium binding wire etc. complete all as specified and as directed. Make - Southern Switchgear / Crompton greaves / Schenider
Restringing of HT 3 lines of existing over head line of ACSR conductor after disconnecting from the insulators & jumpers to the required tension & sag & binding up & connecting to insulators & jumpers properly test complete, chopping off trees branches (coming in the way/line) of span 45-60 mtr 3 wire all as directed. Note : (i) Trimming of tree branches up to 1.5 RM from the conductor deemed to be inclusive in the unit rate. (ii) single conductor shall be considered for measurement complete all as specified and as directed.
S&F PVC sleeves of 15 mm dia in RYB colour for protection of Jumper on HT/LT poles /structure complete all as specified and as directed.
Removing the unserviceable Danger notice plate and S&F danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size complete all as specified and as directed.
M & L for painting to HT Steel tubular poles 11 mtr height by scapping the existing painting and repainting after due preparation of surface and applying a coat of primer i.e. red oxide complete with another coat of Aluminium paint complete all as specified and as directed.
Disconnection & Removing the unserviceable Aluminium conductor/jumper wires from the HT 4 Pole structure and M & L for New Aluminium overhead conductor jumpers sorrounded by PVC insulation sleeves with R,Y& B color code complete all as specified and as directed. Note : (i) All the jumper wires should be replaced with New jumper wires (ii) Type of conductor used for jumper shhould be RABBIT. (iii) Cost deemed to be include for all the misc work such as Nut,bolts, washers, welding etc. for satisfactory completion of job . (iv) Min clearance should be maintained among the conductors as per the Electricity Regulations. (v) Zero percent Sag should be maintained for each jumper wire to avoid short ckts.
All as per item No 121 above here-in-before but for 3 Pole structures complete all as specified and as directed.
All as per item No 121 above here-in-before but for 2 Pole structures complete all as specified and as directed.
Sri Surya Enterprises (BID ID -3374608)
om sai enterprises (BID ID -3374546)
RAMESH CONSTRUCTION COMPANY (BID ID -3381592)
MAYUR ELECTRIC SERVICES (BID ID -3377364)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .