Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.3 LAccepted-AOC CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹81.3 L+₹3.9 L (5.07%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹84.0 L+₹6.6 L (8.57%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹81.5 L
EMD Value
₹1.5 L
Closing Date
12 Jul 2023, 6:00 pmClosed
Shri Santosh Kumar Rai IDSE SE CWE NB
Commander Works Engineer NB Kochi Kataribagh Naval Base PO Kochi 682 004
COMPREHENSIVE MAINTENANCE OF CERTAIN VACANT QUARTERS IN SMA RAMESWARAM PAMPA VIHAR I II AND DAD RESIDENTIAL COMPLEX UNDER GE FORT KOCHI
2023_MES_601175_1
81092
Open Tender
Civil Works
Item Rate
337 days
FORT KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE FORT KOCHI
₹1.5 L
Yes
27 Jul 2023
5 Jun 2023
15 Jul 2023
5 Jun 2023
12 Jul 2023
29 Jun 2023
Amount
Attending the following day to day and comprehensive maintenance complaints and repair works and rectify the complaints to the entire satisfaction of Engineer-in-Charge:- (a) cleaning and servicing of bottle traps and reconnecting to WHB etc. complete all (b) resecuring of chowkhats and frames of any size, taking down shutters and refixing in same opening resecuring after easing and adjusting etc, easing and adjusting of wooden door/window etc. complete all (c) minor plumbing works such as refixing of flushing cistern etc. or any other similar work including dismantling and refixing the same after repair and cleaning complete including material likes screws anf rawl plugs etc. complete all (d) minor mason works such as joint filling, around and inside floor/Nahani trap with white cement to arrest leakage seepage in below floor complete including appliation of chemical water proof treatment to below cieling etc. complete all (e) Filling gaps between chowkats of door & windows with crack filler and finishing uniformly to match the existing surface, etc. complete all (f) minor carpenter works such as refixing of curtain rod and brackets, tower bolts, sliding bolts, hinges , hasp and stapple , knobs etc. complete all (g) removal of choke of RWP/any pipe, Removal of choke in nahani trap or floor trap in WHB, kitchen and toilets, etc. complete all (h) Dismantling and servicing including removal of choke, renewal of rubber washer and refixing in same postion items like 15mm dia bib taps, pillar taps , Angle valves, stop cocks , mixer valves, health faucet,PVC connections, float valves of FT etc. complete all (j) any other miscellaneous complaints and repair works etc. Note :- (i) Complaints will be attended on Sunday/Holidays also. (ii) Complaints/Job cards shall be collected from complaint cell and trade man should submit the feedback of complaints the same day. (iii) The trademen shall wear uniform incl all necessary safety gears etc. (iv) In case of non rectification of complaints a penalty of Rs. 500.00/complaint/day shall be recovered from contractor.
S & F in repairs PVC connections 15mm size with PTMT nuts of length 450 mm long complete all as specified and directed.
S & F in repairs PVC connections 15mm size with PTMT nuts of length 600 mm long complete all as specified and directed.
Taking down 15/16 mm bore UPVC / CPVC / PPR pipe and connections incl cleaning for refixing or removal from site complete all as specified and as directed.
Taking down 20 to 25 mm bore UPVC / CPVC / PPR pipe and connections incl cleaning for refixing or removal from site complete all as specified and as directed
Taking up or down 40/50 mm bore UPVC / CPVC / PPR pipe and connections incl cleaning for refixing or removal from site complete all as specified and as directed
S& F CPVC pipes 16mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified and as directed.
S& F CPVC pipes 20mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified and as directed.
S& F CPVC pipes 40mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified and as directed.
S& F CPVC pipes 50mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified and as directed.
M & L for minor plumbing work to stopping leakages of CPVC pipes of any size upto 4th floor in shafts incl all necessary safety precaution and staging works upto 1 mtr length of pipe including fittings complete all as specified and as directed.
M & L for for minor plumbing work to stopping leakages of CPVC pipes of any size 5th to 8th floor in shafts incl all necessary safety precaution and staging works upto 1 mtr length of pipe including fittings complete all as specified and as directed.
M & L for for minor plumbing work to stopping leakages of CPVC pipes of any size 9th to 12h floor in shafts incl all necessary safety precaution and staging works upto 1 mtr length of pipe including fittings complete all as specified and as directed.
M & L for for minor plumbing work to stopping leakages of CPVC pipes of any size in terrace upto 1 mtr length of pipe including fittingscomplete all as specified and as directed.
S&F 16 mm dia plain CPVC SDR11 stop/ball valves fitted to pipe on walls/ceiling or laying in floors complete all as specified and as directed.
S& F CPVC reducer socket 50mm x 15/20 mm fitted to pipe on walls/ceiling or laying in floors complete all as specified and as directed.
S& F CPVC brass elbow 50mm dia fitted to pipe on walls/ceiling or laying in floorscomplete all as specified and as directed.
S& F CPVC union socket 50mm dia fitted to pipe on walls/ceiling or laying in floors complete all as specified and as directed.
S& F CPVC brass adaptor socket one side threaded and other end pasting 50mm / male threaded fitted to pipe on walls/ceiling or laying in floors complete all as specified and as directed.
Supply and fix in repairs, Soap dish any type fixed to plug with chromium plated fitted to walls with CP/ Brass screws complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair chromium plated shower rose 125 mm dia with swivel joints including fixing to steel/ cpvc pipe or union complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs cast copper alloy chromium plated bib taps 15mm bore fancy type, screwed down, screwed for iron pipe/ cpvc pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-Charge.
S&F two way long body cast copper alloy CP bib cock quarter turn,15mm with wall flange complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repairs stop valves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) , screwed down ,high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 15mm bore cast copper alloy chromium plated fancy type angle stop valve, single lever with wall flange complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair cast copper alloy ball brass valves (float valve), high pressure, with polyethene float and flynut complete screwed for cpvc pipe of 15mm dia complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 15mm bore CP fancy type pillar tap for wash hand basin complete all as specified and directed.
S&F in repairs 32mm bore bottle trap of PTMT having minimum water seal of 25mm (minimum weight 32mm-260 gms), and bore dia of discharge pipe 32mm complete all as specified and as directed.
S&F in repair 17.5mm thick solid plain PVC Sheet suitably fixed as in shelves & partitions in cupboards with stainless steel screws and glue complete all as specified and as directed by the Engineer-in-Charge.
S&F 18/19 mm thick prelaminated HDF board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with 04 Nos SS box hinges per shutter to CB timber frame complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by the Engineer-in-Charge.
S&F 4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane n. exc 0.5 sqm including taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and removed off form premises complete all as specified and as directed by the Engineer-in-Charge.
S&F 4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters area of each pane exc 0.5 sqm complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs stainless steel kitchen plate rack of size 600 mm x 600 mm x 250 mm of 0.5mm thick fixed with plugs screws, washers and waster, including necessary chipping/drilling holes to fix on wall suitable size in wall as per IS specification complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs SS continuous (piano) hinges , mild steel, bright finish or electro galvanised, with width of flap 30mm complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 100mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 150mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 200mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 200mm size PVC sliding door bolt with hasp, staple (bolt type) and fixing clips of PVC and fixing bolts suitable for PVC door shutters complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 125mm size PVC door handle suitable for PVC door shutters complete all as specified and as directed by the Engineer-in-Charge.
S&F butt hinges 100 mm , medium weight, cold rolled and mild steel and complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs butt hinges 75mm , medium weight, cold rolled and mild steel complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs butt hinges 125mm, medium weight, cold rolled and mild steel complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 200mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 150mm aluminium anodised handles, cast typecomplete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 100mm aluminium anodised handles, cast type complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 150mm aluminium anodised hooks and eye complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs hasp and staple,100 mm, safety type, aluminium anodised with mild steel hinge pins including bolt to hinge plate and fixed with screws complete all as specified and as directed by the Engineer-in-Charge.
S&F 75 mm long floor door stopper, aluminium anodised with rubber bush complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair curtain rods fancy type aluminium powder coated not less than 18mm dia complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair fancy type aluminium powder coated bracket suitable for curtain rods fancy type powder coated conduit not less than 18mm dia complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair SS towel rail 20mm dia, D type, 600 mm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in foors etc. set and jointed in cement slurry in isolated area not exceeding 3 Sqm and pointed in white or coloured cement to match over and including 10 mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in foors etc. set and jointed in cement slurry in isolated area not exceeding 3 Sqm and pointed in white or coloured cement to match over and including 10 mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in foors etc. set and jointed in cement slurry in isolated area not exceeding 3 Sqm and pointed in white or coloured cement to match over and including 10 mm thick screed bed in CM 1:4 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 300200/400x250 mm x 7-8 mm thick on vertical surface such as skirting, dados, risers to steps etc set jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10 mm thick backing coat in CM 1:3 in isolated patches not exceeding 1.5 Sqm complete all as specified and as directed by the Engineer-in-Charge.
M&L for minor mason work such as joint filling, refixing of existing tile, plastering work area n. exc 0.1 Sqm each complete including material complete all as specified and directed.
M&L for minor mason work such as joint filling, around and inside floor/nahani trap with white cement to arrest leakage seepage in below floor complete including appliation of chemical water proof treatment to below celing complete all as specified and as directed by the Engineer-in-Charge.
M&L for making 3 mm grooves with cutting machine in floor/wall tiles, filling with epoxy joint filler MYKLAT KRETE SP 100 (Part A, B & C) or equivalent make including filling around floor trap to arrest seepage leakage complete all as specified and as directed by the Engineer-in-Charge.
M&L for minor mason work such as joint filling, of wall tiles with eppoxy including making 4mm joint grooves to arrest leakage seepage complete all as specified and as directed by the Engineer-in-Charge.
M&L for minor mason work such as joint filling around PVC rain water pipes at terrace with CM 1:3 complete all as specified and as directed by the Engineer-in-Charge.
M&L for minor mason work such as filling opening around PVC water pipes at terrace with PCC 1:2:4 type B-0 complete all as specified and as directed by the Engineer-in-Charge.
M&L for minor mason work such as filling around rain water pipes on wall with PCC 1:2:4 type B-0 and finished with plastering in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Raking out/ peeling off decayed wooden part from wooden door frame and shutters and applying anti termite/borer chemical TERMINATOR to the affected area , filling the affected area with a mixture of saw dust , cement putty and white cement , levelled uniformly to match with other part of shutter and finally applying a coat of primer and two coat of enamel paint to match complete all as specified and as directed by the Engineer-in-Charge.
Making good bottom ends of wooden /steel door frames by removing decayed/ rusted portion and filling with concrete and finished to match the frame complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete unreinforced in ground floor or any floor level, PCC curbs and pavings not exceeding 15cm thickness (below or above ground level) and removal of unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 as in kerbs for handrails and similar items including formwork complete all as specified and as directed by the Engineer-in-Charge.
S&F 4mm dia PVC coated cloth drying wire incl hookes at both ends fixed to walls complete all as specified and as directed by the Engineer-in-Charge.
Making 50mm dia holes in RCC parapet and providing UPVC pipe 50mm dia 60 cm long spouts and making good complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) for 20mm bore pipe, as in loft tank complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms) for 15mm bore pipe, as in loft tank complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs PVC flush tank float valve with ball complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC syphon assembly suitable for PVC low level flushing cistern complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair rubber washer suitable for PVC syphon assembly of PVC flushing cistern complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair flush tank knob with lever rod suitable for PVC flushing cistern complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PTMT Floor trap grating doom/ jalli 100mm dia with square frame150x150mm complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC ' L' type flush pipe white colour, of standard length suitable for low level PVC Flushing cistern for EWC complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC ' L' type flush pipe white colour, of standard length suitable for high level PVC Flushing cistern for IWC complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair brass spindle suitable for 15 mm dia bib taps, pillar taps , angle valves, stop cocks , mixer vlaves and similar articles complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair SS knob / head suitable for 15 mm dia bib taps, pillar taps , angle valves, stop cocks , mixer vlaves complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair PVC ball suitable for ball float valve 20mm dia complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair aluminium connecting rod suitable for ball float valve 20mm dia complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 32mm bore waste coupling of PTMT (half or full threaded) (Minimum weight 5gms/40mm-60 gms).suitable for wash basins complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 40mm bore waste coupling of PTMT (half or full threaded) (Minimum weight 5gms/40mm-60 gms) suitable for kitchen sink complete all as specified and as directed by the Engineer-in-Charge.
S&F 32mm bore, 900 mm long PVC flexible waste pipe suitable for wash basin/ kitchen sink complete all as specified and as directed by the Engineer-in-Charge.
M&L for weeding out plants, bushes and completely removing algae, fungus, moulds etc by scraping the surface with putty blades and applying one coat of antifungal cement primer carried out in highrise building complete all as specified and as directed by the Engineer-in-Charge. Note :- The work shall be carried out within one month of work order. The area treated as above shall be maintained free of plants/bushes/algae/fungus/moulds till completion of the contract and payment will be released proportionality.
M&L for preparing old treated surface and applying two coats of damp seal coat of make Dr. Fixit/Syka or equivalent make complete all as specified and as directed by the Engineer-in-Charge.
Taking out decayed/damaged styles/rails of wooden doors and replacing the same with new style/rails of 35 mm thick second class hard wood, to match with the door shutter including two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed by the Engineer-in-Charge.
Taking out decayed/damaged styles/rails of window and replacing the same with new style/rails of 30 mm thick second class hard wood, to match with the window shutter including two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhat with shutter (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhat with shutter (without taking off shutters from the frames) exc 1.5 sqm each complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutter of any description exc 1 sqm but n exc 2 sqm each and refixing in same opening after repair complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, supplying and fixing in opening as per specification and drawing complete all as directed by the Engineer-in-Charge.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing complete all as directed by the Engineer-in-Charge.
S&F pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed by the Engineer-in-Charge.
S&F pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed by the Engineer-in-Charge.
S&F second class hard wood, plain, solid, straight chowkats and frames wrought framed rebated on the solid, rounded or chamffered put together with glue pinned at joints complete all as specified and as directed by the Engineer-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
S&F second class hard wood 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed by the Engineer-in-Charge.
S&F second class hard wood, 35mm thick glazed and skeleton shutters with 8 panels, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed by the Engineer-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
S&F second class hard wood 30mm thick glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats but divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers complete all as specified and as directed by the Engineer-in-Charge.
S & F butt hinges 100mm, medium weight, cold rolled and mild steel complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs butt hinges 100mm, medium weight, cold rolled and mild steel complete all as specified and as directed by the Engineer-in-Charge.
S & F 150mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs 150mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by the Engineer-in-Charge.
S & F 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed by the Engineer-in-Charge.
S & F 150mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs 150mm aluminium handles, cast type, anodised complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparation of new or previously untreated wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described applying with two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 10mm thick in CM 1:6 finished even and smooth without using extra cement with water proofing liquid 200 ml per bag of cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement as on ceiling with water proofing liquid 200 ml per bag of cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of old treated surfaces of wall by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, filling the cracks properly and finally washing with water jet of wall and applying one coat of acrylic distemper over a coat of alkali resitant primer using rollers made from foam or synthetic fibres, to get a smooth and tint free surface complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of old decorated surfaces of wall and applying one coat of white wash complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparing old decorated surfaces of ceiling and applying one coat of white wash on ceiling complete all as specified and as directed by the Engineer-in-Charge.
S&F standard aluminium deco grills including making arrangement for opening window (wt not less than 3 kg per Sqm) grill shall be fixed with suitable clip beading /clamps complete all as specified and as directed by the Engineer-in-Charge.
S&F aluminium powder coated dark cololured two track sliding type window consisting of two numbers glazed shutter with 4mm thick plain sheet glass including provision of airtight beading and one number fly proof shutter with aluminium anodised expanded mesh having mesh size of 1.5mmX3mm and 20g thick,filling the gap with sealent complete with using following sections:- (a)Two track Outer frame 50.80 x 25.40 x 1.2mm, (b) shutter frame 31.80 x 18 x 1.20 mm, (c) Shutter interlock 31.80 x 18 x 1.20mm, (d) Sliding wheel, top bush,handle and locking arrangement etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for 16mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite, set and jointed in neat cement slurry over 20mm thick screed bed in CM 1:4 and pointed in white or coloured cement to match the shade complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white including 'P' or 'S' trap 100mm dia plastic water closet seat, black or white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (including fixing bolts but excluding flushing cistern and flush pipe) complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including provision of cement concrete bedding complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair vitreous China wash basin, white, flat back, size 550x400mm including taps, waste coupling, chain and plug and including brackets/ fixing with bolts etc. complete all as specified and as directed by the Engineer-in-Charge.
M&L for cutting out wall cracks to V-section, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed by the Engineer-in-Charge.
Attending day to day and comprehensive E/M complaints and rectify the complaints with replacement of old unserviceable items such as switches/sockets/holders/fixtures/bells/bell push/light fittings/MCBs/RCBOs etc, to the entire satisfaction of Engineer in charge. Note:- (i) The quoted rate shall be deemed to be included for the cost of minor items like insulation tape, screws, etc. (ii) The materials required for replacement shall be measured and paid seperately under respective item. (iii) Complaints will be attended on sundays/holidays also. (iv) Minimum one electrician and one mate shall be detailed for one set of complaints, with all required tools in neat tool bag. (v) The trademen shall wear uniforms with safety shoes incl all necessary safety gear. (vi) Complaints/job cards shall be collected from complaint cell and trade man should submit the feedback of complaints the in two day, if fails to attend the complaint in prescribed time, penality of Rs. 500 per complaint per day will be recovered.
Supply only switch piano, flush type, single pole, one way, 5 Amps ISI marked complete all as specified and directed.
Supply only switch piano, flush type, single pole, two way, 10 Amps ISI marked complete all as specified and directed.
Supply only switch socket combination outlet multipurpose 2 in 1, 5 pin, 6 Amps and 2 pin 6 Amps flush type ISI marked complete all as specified and directed.
Supply only switch socket combination outlet multipurpose , 6 Amps and 16 Amps flush type ISI marked complete all as specified and directed.
Supply only socket outlet multipurpose 2 in 1, 5 pin, 5 Amps and 2 pin 5 Amps ISI marked complete all as specified and directed.
Supply only socket outlet multipurpose 5 Amps and 16 Amps ISI marked complete all as specified and directed.
Supply only switch piano, flush type, single pole, one way, 15 Amps ISI marked complete all as specified and directed.
Supply only ceiling rose PVC poly carbonate, isolated body with two to three terminals, ISI marked complete all as specified and directed.
Supply only lamp holder, PVC / Poly carbonate type, with cord grip cap suitable for pendent/batten/angle fittings ISI marked complete all as specified and directed.
Supply only bell push, flush type, 5 Amps ISI marked complete all as specified and directed.
Supply only bell Ding Dong AC, 230 volts, single pole ISI marked complete all as specified and directed.
Supply only modular switch 1 way 6A,1 module complete all as specified and directed.
Supply only modular switch 1 way 16A,1 module complete all as specified and directed.
Supply only modular bell push 6A, 1 module complete all as specified and directed.
Supply only modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed.
Supply only modular Socket 6A/16A - 2/3 pin combined, 2 module complete all as specified and directed.
Note for item No141 to 144: Sample for the items are available with AGE E/M Office.
Supply only MCB, SP, 6 to 32 Amps, 240 Volt, having breaking capacity 10 kA, B curve with visual indication complete all as specified and directed.
Supply only MCB, SPN, 6 to 32 Amps, 240 Volt, having breaking capacity 10 kA 'C' curve, with visual indication complete all as specified and directed.
Supply only MCB, TPN, 40 to 63 Amps, 415 Volt, having breaking capacity 10 kA 'B' curve, with visual indication complete all as specified and directed.
Supply only RCCB 25 Amps 30 MA sensitivity short circuit current rating 6 KA double pole complete all as specified and directed.
Supply only high performance low height aesthetic look LED downlight fittings of wattage 15 W suited for modern workplace complete all as specified and directed. Note : Sample for the item is available with AGE E/M Office.
Fixing only surface mounted LED integrated batten four feet long, 22/20/18 Watt with IP 20 protection comprises of PVC housing, integrated electronic driver, diffuser etc and all accessories including connecting up complete all as specified and directed.
Fixing only surface mounted LED fitting 2 feet, 9/10 Watt with IP 20 protection comprises of PVC housing, integrated electronic driver, diffuser etc and all accessories pre-wired including connecting up complete all as specified and directed.
Note for item Nos. 151 & 152 : Light fittings shall be issued by department under Sch "B" stores.
Supply only two pin type LED lamp B22 10 watts suitable for existing angle/batten holder with IP 66 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
Supply only decorative wall light fixture made up of polycarbonate 9 watts with IP 20 protection comprises of polycarbonate housing, high efficiency diffuser polycarbonate cover, lamp 9 watts warm white, etc and all accessories pre-wired complete all as specified and directed by Engineer-in-Charge. Make : Havells City 3 or equivalent from Crompton/ Phillips as approved by GE.
Supply only LED building security light fitting 25 watts protection comprises of a pressure die cast aluminium housing, polycarbonate cover, high power LED with lenses, 10KV built-in-surge protection, electronic driver, etc and all accessories pre-wired including PVC insulated copper conductor cable 1.5 Sq mm, 3 core as required for connections and 32 mm bore light grade G I tube mounting bracket of 1.5 metre in length, bend to shape at 140 degree in ‘L’ shape and flat iron clamps, nuts, bolts and washers etc for fixing complete all as specified and directed by Engineer-in-Charge.
Supply only 3mm thick hylum sheet, cut to suitable size, cutting holes for fixing switches, regulators, sockeets etc complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type TPN 415 volts 4 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type TPN 415 volts 8 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type TPN 415 volts 12 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type SPN 240 volts 8 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type SPN 240 volts 12 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified and directed by Engineer-in-Charge.
S&F MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type SPN 240 volts 4 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified and directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosure with two pin and earth plug and socket complete with one MCB 20 Amps single pole having breaking capacity 10 KA complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1..5 mtr normal ground level, connected to GI strip 32x6mm size as earth lead by means of bolts, nuts , check nuts and washers of GI or steel as shown in electrical plate No 3 connected to earthing test point, testing, (Earthing shall be interconnected) including necessary excavation, 50mm thick RCC 1:2:4 cover reinforced with 8mm TMT bars 100 mm c/c in both ways, salt, charcoal, removal of surplus soil etc including taking out old earth plate complete all as specified and directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket etc) complete, incl fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, lamp holder etc,refixing removed fittings and making good the disturbed surface of wall to match with existing surface complete all as specified and directed by Engineer-in-Charge.
Taking down submain wiring of any type complete all as specified and directed by Engineer-in-Charge.
Taking down DB of any size complete all as specified and directed by Engineer-in-Charge.
Material and labour for point wiring with copper conductor, single core, multistranded, 1100 volt grade, conforming to IS-694 PVC insulated unsheathed FRLSH cables of size 1.5 Sq.mm , one run of 1.5 Sq.mm for earth continuity to be drawn in PVC casing and capping not less than 25 mm width, MS sheet metal switch / terminal box 1.2 mm thick and Hylum sheet switch including all necessary wall cutting for sinking's of boxes and making good disturbed surface to existing walls incl colour washing etc for one light point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 169 here-in-before but for one exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 169 here-in-before but for one fan point controlled by one switch and regulator complete all as specified and directed by Engr-in-Charge.
All as per srl item No 169 here-in-before but for one wall mounted fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 169 here-in-before but for one 5 Amps socket outlet point on same board alongwith other switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 169 here-in-before but for one 5 Amps socket outlet point on independent board controlled by one switch complete all as specified and directed by Engr-in-Charge.
M&L for point wiring in non metallic PVC conduit medium grade/casing and caping, ISI marked of suitable dia, with 4 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes and 1.6mm thick duly painted inner and outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw , cup washer and including PVC insulated and unsheathed stranded copper condutor of 4 Sqmm as continuous earth wire complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring in existing PVC conduit medium grade/casing and caping of concealed/open, ISI marked of suitable dia, with 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes and 1.6mm thick duly painted inner and outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw, cup washer and including PVC insulated and unsheathed stranded copper condutor of 1.5 Sqmm as continuous earth wire for one light point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 176 here-in-before but for one exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 176 here-in-before but for one fan point controlled by one switch and regulator complete all as specified and directed by Engr-in-Charge.
All as per srl item No 176 here-in-before but for one wall mounted fan point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 176 here-in-before but for one 5 Amps socket outlet point on same board alongwith other switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 176 here-in-before but for one 5 Amps socket outlet point on independent board controlled by one switch complete all as specified and directed by Engr-in-Charge.
M & L for point wiring in existing PVC conduit medium grade/casing and caping of concealed/open, ISI marked of suitable dia, with 4 Sqmm PVC insulated unsheathed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes and 1.6mm thick duly painted inner and outside for mounting switches, sockets, fan regulator etc with 3mm thick plastic laminated sheet cover with brass screw , cup washer and including PVC insulated and unsheathed stranded copper condutor of 4 Sqmm as continuous earth wire complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two runs of 2.5 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor including PVC conduit /casing and caping of suitable size and provision of one run 2.5 sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete all as specified and directed by Engr-in-Charge. Note : (1) Two runs of cable, one run of conduit and one run of earth continuity conductor shall be measured as one running metre.
M&L for sub main wiring with two runs of 4 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor including PVC conduit /casing and caping of suitable size and provision of one run 4 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified and directed by Engr-in-Charge. Note : Two runs of cable, one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
M&L for sub main wiring with two runs of 6 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor including PVC conduit /casing and caping of suitable size and provision of one runs 6 sqmm PVC insulated unsheathed single core copper conductor as earth continuity, connected to earth dolly inclusive of all accessories complete all as specified and directed by Engr-in-Charge. Note : Two runs of cable, one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
M&L for sub main wiring with two runs of 2.5 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor in existing PVC conduit /casing and caping of suitable size and provision of one run 2.5 sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete all as specified and directed by Engr-in-Charge. Note : Two runs of cable & one run of earth continuity conductor shall be measured as one running metre.
M&L for sub main wiring with two runs of 4 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor in existing PVC conduit /casing and caping of suitable size and provision of one run 4 sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete all as specified and directed by Engr-in-Charge. Note : Two runs of cable & one run of earth continuity conductor shall be measured as one running metre.
M&L for sub main wiring with two runs of 6 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor in existing PVC conduit /casing and caping of suitable size and provision of one runs 6 sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete all as specified and directed by Engr-in-Charge. Note : Two runs of cable & one run of earth continuity conductor shall be measured as one running metre.
Note for Item Nos 169 to 188: Wiring shall be carrired out in multi store building upto 12th floor and rate for transporation of materials and tools are deemed to be included in the quoted rate
Supply only electronic fan regulator stepped, flush type suitable for existing ceiling fans fixed on phenolic laminated sheet as required complete all as specified and directed by Engr-in-Charge.
S&F LED fitting, 1 x 9/10 watt bulk head luminaries, with lamp holders, etc complete with all accessories and including connecting up with twin core copper conductor cable with suitable size of 230 V, 50 Hz complete all as specified and directed by Engr-in-Charge.
Disconnection of electrical wire from ceiling rose and taking down ceiling fan of any type/size,make more over dismantling the ceiling fan for removing of old lubricating substatance from bearing/bush and applying fresh lubrication using grease to avoid noise free smooth functioning, including replacement of worn out/unserviceable spares as required and replacement of PVC insulated, unsheathed multi stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 0.5 M long incl testing the repaird ceiling fan to the entire satisfication of Engineer in charge and refixing the fan in own position with provision of hanging bush, cotter pins, nut , bolts washers etc complete all as specified and directed by Engr-in-Charge. Note : Rewinding of ceiling fan and PVC wire for making connection shall be measured and paid seperately under respective item .
Rewinding of ceiling fan 230 volts, of any make/type and size (1200/1400 mm sweep) with copper wire of same gauge and number of turns as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor complete all as specified and directed by Engr-in-Charge. Note : The RPM shall be checked and match as per manufactures specification till entire satification of Engr-in-Charge before fixing the ceiling fan at site.
Carrying out re-metalling in worn out shaft, cutting and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to entire satifaction of Engineer in change. Note : Bearing shall be measured and paid seperately.
Supply only ball bearing of any size and type, suitable for any type/make/size of ceiling fan complete all as specified and directed by Engr-in-Charge.
Supply and fixing capacitor of capacity 2.5 MFD, 220 volt ISI marked complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC insulated, unsheathed multistranded twin twisted copper flexible cable of size 1.5 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply only suitable size of bush for ceiling fan of any type/size complete all as specified and directed by Engr-in-Charge.
Supply and fixing of PVC connector 4 way 6 Amps with connection screws, nuts. etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and directed by Engr-in-Charge.
Supply and fixing alloy steel heavy duty "S" or "D"-hook hanger with double fasteners M10 x 75mm for hanging ceiling fan sted wornout hook complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair heavy duty steel and rubber fan to ceiling hook attachment clamp with fan rod nut bolt and locking pins complete set complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling fan blade of 1200/1400mm size of existing make including proper painting matching with the existing ceiling fan complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC canopy suitable for ceiling fan of any type/make for both end of down rod including fixing screws complete all as specified and directed by Engr-in-Charge.
Supply and fixing down rod 1'/1.5' suitable for ceiling fan of any type/make for both end of down rod including fixing screws complete all as specified and directed by Engr-in-Charge.
Cleaning of ceiling fan assembly of any type/size and carrying out two coats of spray painting with first quality synthetic enamel paint of approved colour, including writing of MES number in black paint complete all as specified and directed by Engr-in-Charge.
Disconnection of electrical wire from exhaust fan and taking down exhaust fan of any type/size, make moreover dismantling the exhaust fan for removing of old lubricating substance from bearing/bush and applying fresh lubrication using grease to avoid noise free smooth functioning, including replacement of worn out/unserviceable spares as required and replacement of PVC insulated, unsheathed multi stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 0.5 M long incl testing the repaird ceiling fan to the entire satisfication of Engineer in charge and refixing the fan in own position with provision of hanging bush, cotter pins, nut , bolts washers etc complete all as specified and directed by Engr-in-Charge. Note : Rewinding of ceiling fan and PVC wire for making connection shall be measured and paid seperately under respective item.
Rewinding of exhaust fan 300 mm sweep, 230 volts of any make/type, with super enamelled copper wire of appropriate gauge and number of turns as existing to obtain the specified and satisfactory RPM as per menufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection and testing complete all as specified and directed by Engr-in-Charge. Note : The RPM shall be checked and match as per manufactures specification till entire satification of Engr-in-Charge before fixing the exhaust fan at site.
All as per srl item No 209 here-in-before but for exhaust fan of 380 mm sweep complete all as specified and directed by Engr-in-Charge.
All as per srl item No 209 here-in-before but for exhaust fan of 450 mm sweep complete all as specified and directed by Engr-in-Charge.
Supply and fixing of louver shutter made of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made of MS flat strips of size 25mmx3mm including heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall fater driling and duly painted by two coat of synthatic enamel paint (spray painting) over a coat of primer for exhust fan up to 300/380 mm sweep complete all as specified and directed by Engr-in-Charge.
M&L for fan motor suitable for PVC body exhaust fan upto 250 mm sweep and RPM match with existing including taking down old motor and fixing of new with proper allignment and refixing the same using necessary mounting screws and accessories without any vibrations and noise to the satisfaction of Engr-in-Charge.
Supply and fixing capacitor 230 volt, AC 50 HZ, 4.0 MFD, 220 volt ISI marked complete all as specified and directed by Engr-in-Charge.
Repair to unserviceable storage water heaters (Geyser) of 25 to 50 ltr capacity by taking down, replacing the defective parts with new parts and refixing after clearing the defects and make it operational complete all as specified and directed. Note: (i) New parts will be measured and paid under supply only items seperately. (ii) The cost of labour and consumables required for replacement of parts, arc or gas welding for tank leakages shall be deemed to be included in unit rate quoted by the contractor.
Supply only thermostat suitable for 25/50 ltr capacity Geyser complete all as specified and directed by Engr-in-Charge.
Supply only geyser inlet and outlet assembly for 25/50 liters capacity geyser compete incl all fixing accessories complete all as specified and directed by Engr-in-Charge.
Supply only pressure release valve suitable for 25/50 ltr capacity Geyser 8 bar complete all as specified and directed by Engr-in-Charge.
Supply only heating element 1.5KW/2KW suitable for 25/50 Itr capacity Geyser as per site requirements compatible with any brand of geyser complete all as specified and directed by Engr-in-Charge.
Supply only mounting bracket assy suitable for 25/50 ltr capacity Geyser complete all as specified and directed by Engr-in-Charge.
Supply only SS inner tank suitable for 25 ltr capacity Geyser complete all as specified and directed by Engr-in-Charge.
Supply only 3 core 2.5 sqmm PVC flexible copper condutor suitable for Geyser complete all as specified and directed by Engr-in-Charge.
Supply only connection pipe 15mm dia 450mm long for hot/cold water both end connected with screwed brass nut complete all as specified and directed by Engr-in-Charge.
Supply only neon indicating lamp suitable for 25/50 ltr capacity complete all as specified and directed by Engr-in-Charge.
Supply only surface mounted LED integrated batten four feet long, 22/20/18 Watt with IP 20 protection comprises of PVC housing, integrated electronic driver, diffuser etc and all accessories including connecting up complete all as specified and directed by Engr-in-Charge.
Notes for Serial Item Nos 1 to 225:- (a) Contractors representative/ supervisor/Engineer will report to Engr-in-Charge/ concern JE daily in morning to collect complain for routine/urgent works related to day to day maintenance and comprehensive maintenance till completion of contract. The contractor or his authorised rep shall collect the complaint of all works from complaint cell/Engr-in-charge daily and all complaints will be rectified by the contractor with in same day and then return the complaint slip after completion of complaint and get receipt from concerned JE/Engr-in-charge. (b) One electrician, one plumber and one helper of Contractor shall be available round the clock at complaint cell for all routine/urgent works related to day to day maintenance and comprehensive maintenance till completion of contract (c) All routine jobs/complaints received on docket slip shall be attended within 24 hrs. All urgent jobs/complaints like no electric and water supply/power cut off, sewage blockage, water leakage etc. and similar nature urgent jobs/complaints shall be attended within 06 hrs. If the nature of job is such that which cannot be completed within 24 hrs/ 06 hrs, it shall be immediately brought in to the notice of Engr-in-Chrage. (d) The period for working to the such complains shall be decided by GE/Engr-in-Charge. If delay is more than 24 Hrs for routine jobs/ 06 Hrs for urgent jobs & GE/ Engr-in-Charge is not satisfied with reason for delay in working then the penalty of Rs. 500.00/complaint/day shall be recovered from contractor. (e) If any complaint is not resolved to the satisfaction of Engineer-in-charge, then the unsatisfactory complaints shall be re-done/resolved again by the contractor at free of cost complete in all respects to the entire satisfaction of Engineer-in-charge and no extra payment or claim shall be entertained on this account whatsoever. (f) In case of any dispute arising from above the decision of Accepting Officer shall be final and binding.
Notes (Contd/..) The quoted rates shall be deemed to include for items of comprehensive maintenace of Bldgs/quarters upto G+13 height above all external/ internal surface finishes and include the following:- 1. Use of all scaffolding, trestles, ladders, cradles etc. necessary for execution of work and protective measures. 2. Removing of nails, making good holes, cracks etc. 3. Work in patches, and in narrow/ widths, bands, cornices, plasters etc and cutting in edges to line where necessary. 4. Spreading and removing covering to doors, windows, floors, fitting etc to protect them from splashes. 5. Removing and replacing furniture, movable cupboard, chicks, blinds, etc washing floors, cleaning glass, joinery, electric fittings, wiring, etc of drops and splashes and leaving premises, clean and tidy followed.
LAKSHMI BUILDERS
PRC ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .