Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹10.7 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹13.5 L+₹2.7 L (25.3%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹13.5 L+₹2.7 L (25.3%) | L2 | Rejected-Finance Rejected due to bidder not L1 |
| 3 | L3₹13.5 L+₹2.8 L (25.7%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹13.5 L+₹2.8 L (25.7%) | L3 | Rejected-Finance Rejected due to bidder not L1 |
| 4 | L4₹13.6 L+₹2.8 L (26.2%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹13.6 L+₹2.8 L (26.2%) | L4 | Rejected-Finance Rejected due to bidder not L1 |
| 5 | L5₹15.6 L+₹4.9 L (45.5%)Rejected-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹15.6 L+₹4.9 L (45.5%) | L5 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Sh K A Vardhan, IDSE
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION WORKS IN MD/OTM ACCN AT AHMEDABAD
2022_MES_532923_2
8258/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (Army) Ahmedabad
As per NIT
9 documents required · 9 mandatory
₹500
GE (Army) Ahmedabad
₹40,000
Yes
27 Sept 2022
24 Jun 2022
28 Jul 2022
24 Jun 2022
27 Jul 2022
7 Jul 2022
30 Jun 2022 - 7 Jul 2022
Amount
Taking down carefully surface aluminium or copper point wiring (light, fan, socket, bell or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized Pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3.0mm thk phenolic laminated white sheet cover for mounting of switches, sockets, fan regulators including making good the wall surfaces to match with existing etc. for One light point controlled by one switch complete.
All as described in Item No 02 above but for One fan point /Exhaust fan point controlled by one switch.
All as described in Item No 02 above but for One light point controlled by two, two way switches.
All as described in Item No 02 above but for One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as described in Item No 02 above but for One socket outlet 6 amp controlled by one switch on indepdendent board.
All as described in Item No 02 above but for One bell point controlled by one bell push.
All as described in Item No 02 above but for one 16 amp socket outlet controlled by one switch on independent board using copper conductor cable 4 sqmm complete
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x12 mm ISI marked ivory colour with all accessories and sunken in galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators for One light point controlled by one switch complete.
All as described in Item No 09 above but for One fan point /Exhaust fan point controlled by one switch.
All as described in Item No 09 above but for One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as described in Item No 09 above but for One socket outlet 6 amp controlled by one switch on indepdendent board.
All as described in Item No 09 above but for One bell point controlled by one bell push.
All as described in Item No 09 above but for One light point controlled by two, two way switches.
All as described in Item No 09 above but for one 16 amp socket outlet controlled by one switch on independent board using copper conductor cable 4 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 4 sqmm (Green) complete
S&F angle holder, insulated polycabonate body with back plate complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F switch flush type, 6 amp, single pole, two way complete.
S&F bell push, flush type, 6 amp 240 volts complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
M&L in repairs submain wiring with 2x4 sqmm and earth continuity 1x4 sqmm conductor PVC insulated FR-LSH multistranded copper conductor cable (Phase - R,Y,B, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit medium grade 20 mm dia conduit ISI marked ivory colour along with accessories complete.
M&L in repairs submain wiring with 2x6 sqmm and earth continuity 1x6 sqmm conductor PVC insulated FR-LSH multistranded copper conductor cable (Phase - R,Y,B, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit medium grade 25 mm dia conduit ISI marked ivory colour along with accessories complete.
M&L in repairs submain wiring with 2x4 sqmm and earth continuity 1x4 sqmm conductor PVC insulated FR-LSH multistranded copper conductor cable (Phase - R,Y,B, Neutral - Black, Earth - Green) drawing into into including PVC casing-caping not less than 25x12 mm ISI marked of following nominal sizes
M&L in repairs submain wiring with 2x6 sqmm and earth continuity 1x6 sqmm conductor PVC insulated FR-LSH multistranded copper conductor cable (Phase - R,Y,B, Neutral - Black, Earth - Green) drawing into into including PVC casing-caping not less than 25x12 mm ISI marked of following nominal sizes
S&F in replacement LED Batten 20 watt tube light fiiting with decorative type fitting 4 feet long with Light Linear with its bright light output at 100 lumen/watt give batten type including all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core 6500K & shall be fitted on two plastic square/round block & similar to code LDLSR20-CDL of crompton make complete. Note : power factor should not be less than 0.90Sqmm, PF>0.9 all as required
S&F in replacement sleek LED mirror light fitting 2 feet long, 1x10 W including LED tube 2 feet long of same make having ballast, bipin holder, connector block etc & all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, 6500K, PF>0.9 and similar to Code no D531065 (lumen 1000) of make Wipro all as required complete.
S&F in replacement energy efficient recessed mounted LED luminaire 36 Watt suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required & similar to cat no LCTLRN-36CDL of crompton make complete
S&F in replacement Wall LED light fitting including fixing arrangement on wall with suitable size of GI pipe bend into shape, clamps and nut & bolts for fitting capacity of LED 20 watt with pressure diecast aluminum housing & polycarbonate having top opening seperate driver compartment with IP66 protection and impact resistance IK07 duly prewired connection & similar to 'PINNACLE' Cat no LST-20-CDL of make crompton complete.
S&F in replacement LED bulk head light fitting 1X10watts complete including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of suitable size & similar to Code no DA11027 of Wipro make complete.
S&F in replacemen LED Lamp 9 watt 230 volts complete.
S&F in replacement sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V with one single pole MCB of capacity 20 A complete
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP43 -IK09 protection single phase 240 volts 4 way including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification.
S&F in replacement MCB distribution board SPN 240 volts 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP43 -IK09 protection single phase 240 volts 12 way including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete
S&F in replacement Distribution board (ETPN) iron clad, double door with IP-54 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way with appropriate size copper bus bar and neutral link including with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required complete. (Note : Outgoing MCB will be measured separately).
S&F in replacement tripple pole and neutral, powder coated, CRCA steel sheet Vertical bus bar distribution board (VTPN) constructed as per IS 8623 , IP-54 1K-09 suitable for MCCB incomer upto 125 amp, 4 way, 415 volts, degree of protection IP 43, mechanical strength IK 08 with metal door, recess mounted, having 200 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required etc. & similar to Make Legrand cat no 607913 or Indoasian cat No 81188 complete.
S&F in replacement MCBs Single pole 6 to 32 amp of 'B' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete
S&F in replacement MCBs Double pole 10 to 32 amp of 'B' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete
S&F in replacement Ding dong bell AC 240 volts complete
Note :- MCBs & MCB DBs shall be of the same make.
ALBA AC AND REF SERVICES
Abhishek Enterprises
ARTI CONSTRUCTION
Shree Karni Construction
TECH SERVE SOLUTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .