Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.7 L+₹44,269.75 (6.07%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L2 | Rejected-Finance Not being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category as per NIT |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
6 May 2024, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361150
Provision of RO Plant at certain unit under GE (I) Jamnagar
2024_MES_648746_1
8744/VAL/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹17,000
Yes
4 Jun 2024
30 Mar 2024
8 May 2024
30 Mar 2024
6 May 2024
24 Apr 2024
Amount
Dismantling of Asbestos cement Corrugated or semi corrugated sheets etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to outside MoD land and depositing where directed complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
M&L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified & as directed. Note : Measurements shall be taken after compaction.
M&L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified.
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4 complete all as specified & as directed.
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork and scaffolding complete all as specified and as directed. Note : Reinforcement shall be measured and paid for separately.
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) in foundations including rafts, footings, foundation beams, bases for columns, mass concrete and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) in columns, pillars, piers, posts, struts and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified & as directed.
S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.
S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing, anodised aluminium snap on beading, neoprene gasket etc. complete all as specified and as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutter, side hung type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.), suitable handle (2 Nos.) etc. complete all as specified and as directed. Note: Glass shall be measured and paid for seperately.
S&F 150 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 150mm size extruded aluminium alloy handles (ISI Marked), fabricated type, anodised and fixed.
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
All as per serial item No. 27 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls, fixed with self tapping screws complete all as specified & as directed. Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc
M&L for 75mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.
M&L for 100 mm thick PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in flooring and hardstanding finished fair and even complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.
Supply, installation, testing and commissioning of pedestal mounting, Outdoor type, heavy duty, cubical & compartmentalized, electric LT Panel, dust and vermin proof, fully tropicalized construction, front openable shutters with locking arrangement, made out of 3.15 mm thick CRCA steel sheet, CPRI approved manufacturer, powder coated suitable for operation on 415 Volts, Three phase, 50 Hz, AC supply complete with all interconnections and consisting of all accessories like Aluminium Bus Bar of capacity 100 Amps TPN, LED Type Indicating lamps for ON/OFF condition and RYB LED indicating lamps, On /Off lamps including multi functional meter with suitable CTs for measuring Voltages, Amps, etc., Danger Plate, Feeder Name Plates suitable for the following feeders {Panel shall be of minimum size 1200 (L) x 1200 (B) x 300 (D) mm to accommodate all the accessories mentioned below, installed on pedestal mounting of 650mm height of Angle Iron 45x45x5mm} with & including following accessories :- description of item continued…..
description of item No. 43 continued….. (a) Incomer Feeder :- (i) MCCB 63 Amps, 415 Volts with micro thermal based with inter rupturing breaking capacity 16 kA including all connecting accessories like spreader terminal etc - 01 No (b) Outgoing Feeders :- (i) MCB TPN 32 Amps, 10 kA, ‘C’ Curve - 01 No. (ii) MCB SPN 32 Amps, 10 kA, ‘C’ Curve - 03 Nos (iii) Switch socket combination 3 pin 16A - 03 Nos (iv) MF meter -01 No. with LED indicators – 05 Nos
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply and laying/fixing 50 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed.
S&F 25 mm bore galvanized steel water tubing medium grade (ISI Marked) with & including all necessary fittings (ISI Marked) such as bend, tee, elbow, etc laid in trenches/ floors or fixed on wall and ceiling complete all as specified and as directed. Note : Excavation & earthwork shall be measured & paid for separately.
All as per serial item No. 47 here in above but 40 mm bore.
Supply, laying & jointing 15mm bore UPVC Pipes (Sch 80) with & including all necessary UPVC fittings (Sch 80) such as bend, tee, socket, elbow, etc, Solvent Weld Pipe (Lead Free), laid in trenches/floor or/and fixed to walls in required length and testing on completion, complete all as specified and as directed. Notes :- (i) Excavation & earthwork shall be measured & paid for separately. (ii) The quoted rates shall include for fittings and jointing materials.
All as per serial item No. 49 here in above but 25 mm bore.
All as per serial item No. 49 here in above but 40 mm bore.
S&F 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe complete all as specified & as directed.
All as per item No. 52 here in above but 40 mm bore
S&F 40mm bore Stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & as directed.
S&F UPVC ball valve (Sch 80) of size 15 mm bore complete all as specified & as directed.
S&F UPVC ball valve (Sch 80) of size 25 mm bore complete all as specified & as directed.
S&F UPVC ball valve (Sch 80) of size 40 mm bore complete all as specified & as directed.
M&L for construction of Valve pit chamber of size 900x900x900mm internal dimension including necessary excavation & earth work in any type of soil, PCC 1:4:8 type D2 in foundation, brick work with old size fly ash bricks in CM 1:4, 15 mm thick plaster in CM 1:4 internally and externally flush pointed in same mortar as work proceeds, 75 mm thick PCC coping all round in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate), flooring shall be 40 mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate laid over 75 mm thick hard core. Top cover shall be made out of MS sheet 3.00 mm thick fixed in angle iron frame made out of angle iron size 40x40x6 mm with two number of hinges on one side and locking arrangement at other side complete including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. Note : Any minor modification where required at site shall be deemed to be included in the quoted rates. The decision of GE shall be final and binding regarding extent to which the change can be considered as minor.
Supply, installation, testing and commissioning of drinking water filtration system (RO Plant) of output capacity 250 Ltr/hr with Reverse Osmosis Membrane (RO Membrane), Multi Grade Filter / Dual Media filter of FRP made including all kind of UPVC connections to Raw water pump, Drinking water pump and Back wash system complete with installation of Digital TDS controller to maintain Hardness below 10 ppm, TDS below 150 ppm, PH range 6.5 - 8.0, alkaline water with auto and manual ON/OFF mode with & including following accessories :- (a) Micron cartridge filter of PP type 5 micron, (minimum capacity of 5000 LPH), replaceable type - 02 Nos. (b) Flow meter - 02 Nos of capacity 1000 LPH (c) Pressure Gauge 0 - 21 Kg/sqcm - 01 No (d) Raw water Pump horizontal type (centrifugal) -02 Nos, Single phase, 0.5 HP of make- Lubi/Kirloskar/CG (01 No. raw water + 01 No. filter water) (e) High pressure pump Vertical multistage centrifugal type - 01 No Single phase 220 Volts of capacity 1000 LPH/2.0HP of make- Lubi/Kirloskar/CG. (f) Dual media filter -01 No. of FRP made with MPV distribution system. description of item continued…..
description of item No. 59 continued….. (g) The plant must have antiscalent dozing system with dozing pump of capacity 2 - 6 LPH and tank of 100 litre capacity. (h) All pumps shall be controlled by MS powder coated control panel - 01 No. The control panel shall have fittings/fixtures to measure LPS, HPS with Flushing and alarm facility, fully automatic level function with level switch. Note : The quoted rates shall deemed to inclusive of all kind of civil, pipe works, valves/NRVs and electrical wiring work required to run and accommodate all above with skid mounting structures made of stainless steel and foundation complete all as specified and directed.
S&F 2000 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered for Raw water and Filter water storage and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
fakhrie apostrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .