Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L1 | Accepted-AOC Accepted due to lowest | |
| 2 | L2₹8.4 L+₹1.8 L (27.2%)Rejected-AOC RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-AOC rejected due to other than lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
20 Aug 2021, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Near Jagraon Bridge Ludhiana-141001
REPAIR AND PERIODICAL MAINT OF DG SETS INSTALLED UNDER GE LUDHIANA
2021_MES_452213_2
GE/LDH-13/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE Ludhiana
₹20,000
Yes
8 Sept 2021
23 Jul 2021
21 Aug 2021
23 Jul 2021
20 Aug 2021
3 Aug 2021
23 Jul 2021 - 2 Aug 2021
Amount
Servicing, calibration, setting and testing of injector assembly of DG set of capacity 200 KVA including replacement of injector delivery valve, oil seal etc and testing on full on load complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 1.01 above but DG set of capacity 62.5/75/82.5 KVA
Description all as per item No 1.01 above but DG set of capacity 7.5 to 50 KVA.
Servicing, calibration, setting and testing of injector assembly of DG set of capacity 200 KVA including replacement of injector cup nozzles and plunger etc and testing on full on load complete all as specifiedand directed by Engineer-in-Charge.
Description all as per item No 04 above but DG set of capacity 62.5/75/82.5 KVA.
Description all as per item No 4 above but DG set of any model of capacity 7.5 to 50 KVA.
Dismantling and removing of oil pan cleaning the same including replacement of new engine oil GTx24, refixing the oil pan to its original position incl replacement of new gasket, worn out nuts bolts and washer etc for Gen set 200 KVA capacity complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 07 above but Gen set of capacity 62.5/75/82.5 KVA
Description all as per item No.7 above but Gen set of capacity 7.5 to 50 KVA
S&F in replacement diesel filter element with O ring for Gen set of capacity 200 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per item No.10 above but Gen set of capacity 62.5 / 75 / 82.5 KVA.
Description all as per item No.10 above but Gen set of capacity 7.5 to 50 KVA.
S&F in replacement lubricating oil filter with O ring for Gen set of capacity 200 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per item No.13 above but Gen set of capacity 62.5 / 75 / 82.5 KVA.
Description all as per item No.13 above but Gen set of capacity 7.5 to 50 KVA.
S&F in replacement by- pass filter element with O ring for Gen set of capacity 200 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per item No.16 above but Gen set of capacity 62.5 / 75 / 82.5 KVA.
Description all as per item No.16 above but Gen set of capacity 7.5 to 50 KVA.
S&F in replacement core cooler element with O ring for Gen set of capacity 200 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per item No.19 above but Gen set of capacity 62.5 / 75 / 82.5 KVA.
S&F in replacement air cleaner element (inner) with O ring for Gen set of capacity 200 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per item No.21above but for Gen set of capacity 62.5 / 75 / 82.5 KVA.
S&F in replacement air cleaner element (Outer) with O ring for Gen set of capacity 200 KVA complete all as specified and directed by Engineer-in-Charge.
Description all as per item No.23 above but for Gen set of capacity 62.5 / 75/ 82.5 KVA.
Dismantling and repair to self starter assembly 24 volt DC for gen set 200 KVA including rewinding of armature, replacement of carbon brush, bearing and worn out nut bolts etc and refixing all as original including testing complete etc all as directed by Engineer-in-Charge.
Description all as per item No. 25 above but for Gen set 75/62.5 KVA 12 Volt.
Description all as per item No. 25 above but for Gen set 7.5 to 50 KVA 12 Volt
Dismantling of water pump assembly for Gen set 200 KVA, reparing the same including replacement of water body repair kit, water seal and worn out nuts, bolts, gasket etc and refixing & testing complete all as specified and etc all as directed by Engineer-in-Charge.
Description all as per item No. 28 above but for Gen set 50 to 75 KVA
Dismantling and removing of radiator assembly for Gen set 200 KVA, cleaning the same with descaling solution and repairing the damage fins by brazing/ soldring etc re-fixing the same to its position inculding replacement of worn out nut bolt, gasket etc hose pipe with clamp etc all as directed by Engineer-in-Charge
Description all as per item No. 30 above but for Gen set 50 to 75 KVA.
S&F in replacement lead acid battery 12 volt, DC 100 AH complete complete all as specified and etc all as directed by Engineer-in-Charge.Make-Exide
S&F in replacement lead acid battery 12 volt, DC 150 AH complete complete all as specified and etc all as directed by Engineer-in-Charge.Make-Exide
S&F in replacement lead acid battery 12 volt, DC 180 AH complete complete all as specified and etc all as directed by Engineer-in-Charge.Make-Exide
S&F in replacement Automatic battery charger, 24 V DC, 10 A complete complete all as specified and etc all as directed by Engineer-in-Charge
S&F in replacement CTs, 150/5 A, Cl complete complete all as specified and etc all as directed by Engineer-in-Charge
S&F in replacement Emergency stop switch complete complete all as specified and etc all as directed by Engineer-in-Charge
S&F in replacement Indicators 24v DC - 02 Nos, 220v AC complete complete all as specified and etc all as directed by Engineer-in-Charge
S&F in replacement Line (under / over) voltage monitoring relay 415 v AC complete complete all as specified and etc all as directed by Engineer-in-Charge
S&F in replacement Auto / manual switch complete complete all as specified and etc all as directed by Engineer-in-Charge
S&F in replacement Push buttons (green/red) for ON/OFF complete complete all as specified and etc all as directed by Engineer-in-Charge
Dismantaling and removing turbo charger assembly for Gen set of capacity 200 KVA, repairing/ servicing the same including repalcement of turbo charger repair kit, seal and worn out nuts, bolts etc refixing and testing complete all as specified and directed by Engineer-in-Charge.
Description all as per item No. 44 above but for DG set of capacity 62.5 to 75 KVA.
Supply & fixing in repalcement complete fuel pipe set for Gen set of capacity 200 KVA all as specified and directed by Engineer-in-Charge.
Description all as per item No. 46 above but for Gen set 50 to 75 KVA.
M&L for dismantaling alternator of DG set capacity 50 to 82.5 KVA, transporting to civil workshop for repair. strip opening of alternator, taking out burnt copper winding, cleaning the slouts of stator and cleaning the roter, rewinding the stator field coil with supper enameled copper winding wire of existing size and gauge including provision of new insulating material of class 'E', insullation warnishing, heating etc reassembling the same, bringing back to its original location, connecting and testing complete all as specified and directed by Engineer-in-Charge.
Supply & fixing for pressure gauge 0 to 300 PSI pannel mounting type of size 50mm dia all as specified and directed by Engineer-in-Charge.
Supply & fixing for water temprature gauge pannel mounting type of size 50mm dia all as specified and directed by Engineer-in-Charge.
Supply & fixing for techo meter with cable pannel mounting type of size 100mm dia all as specified and directed by Engineer-in-Charge.
Supply and filling of coolent superior quality (For radiator of Gen set) all as specified and directed by Engineer-in-Charge.
Supply and wrapping of asbestos rope 20mm dia superior quality on exhaust pipe of Gen set all as specified and directed by Engineer-in-Charge.
M&L for scraping of old painted surface of Gen set of capacity 200 KVA including panel, fuse tank etc, prepration of steel surface painting of Gen set, inculding all accessories with two coats of super enamelled paint of approved colour and over a coat of primer inculding marking of SM/ MES No. of suitable size with white paint all as directed by Engineer-in-Charge.
Description all as per item No 54 above but Gen set of capacity 75/62.5 KVA.
Description all as per item No 54 above but Gen set of capacity 7.5 to 50 KVA.
Supply & fixing in replacement copper conductor, single core of size 19/0.083 as in battery lead all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement battery terminal of brass all as specified and directed by Engineer-in-Charge.
Servicing, cleaning and setting of all components inculding cleaning of all contacts of relay power contactor coil etc inculding checking of electrical circuit and replacement of worn out wiring with suitable size copper wire and replacement of defective parts such as relay, timer, power contactor, Ampermeter/ Voltmeter etc testing complete all as specified and directed. NOTE:- Replacement of accessories such as relay, timer, power contactor, meters shall be measusred and paid seperately.
Supply & fixing in replacement power contactor 4 pole 415 Volt with coil voltage 230 Volt complete of capacity 100 Amp all as specified and directed by Engineer-in-Charge..
Supply & fixing in replacement power contactor 4 pole 415 Volt with coil voltage 230 Volt complete of capacity 300 Amp all as specified and directed by Engineer-in-Charge..
Supply & fixing in replacement engine starting relay, 24 Volt DC On/Off setting time 0 to 10 Sec all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement over load/ under voltage relay 415 Volt AC supply voltage setting 300 to 500 Volt trip timing 0 to 10 Sec all as specified and directed by Engineer-in-Charge.
Supply & fixing for copper lugs of size 195 sqmm to 240 sqmm complete all as specified and etc all as directed by Engineer-in-Charge.
Description all as per item No.66 above but 95 to 150 sqmm.
Description all as per item No.66 above but 50 to 70 sqmm.
Description all as per item No.66 above but 16 to 35 sqmm.
S & F in replacement on load Changeover Switch 415 V 4 pole of capacity 63 Amps.
S & F in replacement on load Changeover Switch 415 V 4 pole of capacity 100 Amps.
S & F in replacement on load Changeover Switch 415 V 4 pole of capacity 200 Amps.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .