Loading…
Loading…
| # | Schedule | Awarded To | Bids | Value |
|---|---|---|---|---|
| 1 | Schedule 1 | ANANT ENTERPRISES | 11 | - |
| 2 | Schedule 2 | ANANT ENTERPRISES | 11 | - |
| 3 | Schedule 3 | ANANT ENTERPRISES | 11 | - |
| 4 | Schedule 4 | ANANT ENTERPRISES | 11 | - |
| 5 | Schedule 5 | ANANT ENTERPRISES | 11 | - |
Tender Value
₹19.4 L
EMD Value
Exempted
Closing Date
9 Jan 2024, 6:00 pmClosed
MEDICAL AND SURGICAL EQUIPMENTS
5806904
GEM/2023/B/4402091
Two Packet Bid
COLLAPSIBLE STRETCHER,WHEEL CHAIR,DIGITAL BP APPARATUS,MULTIPARA MONITOR,AED,ILR,ECG MONITOR 6 CHAN
15 days
Haryana; Ambala
Item wise evaluation
BOQ
8 documents required · 8 mandatory
2 yrs
₹3
20%
Exempted
15 Jan 2024
1 Jan 2024
9 Jan 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | COLLAPSIBLE STRETCHER | Overall Length of trolley 2030 mm Overall width of trolley 710 mm Provision of height adjustment Provision of mattress Provision of Saline rod Provision of storage tray 4 Number of castor wheels Provision of Oxygen cylinder arrangement Tuck down type railings Warranty 2 years | 2 | Nos | Ambala | 15 |
| 2 | WHEEL CHAIR | Back rest with Cushion Cushion on Seat Fixed height Swinging and Detachable Leg guard Fixed Back rest Overall Length 1020 mm Foldable Attendant Controlled Non Powered Handle for push/pull action of Wheel Chair Cushion on Arm rest Matte Material of Seat Foot rest Material aluminium Loading capacity 120 kg | 5 | Nos | Ambala | 15 |
| 3 | DIGITAL BP APPARATUS | Digital Sphygmomanometer Automated Measuring device Portable LCD Display Inflation Automatic Pressure Application by pump Deflation and rapid Air Release Automatic Pressure Release Valve Cuff Range Medium 22 to 32 cm Power Source is Either Charageble Battery Set Or 220 Volt 50 Hz AC Supply Warranty Period 2 years Pressure measurement range 0 to 300 mmhg Automatic power off if system is idle for 3 minutes | 6 | Nos | Ambala | 15 |
| 4 | MULTIPARA MONITOR | Modular Monitor Monitoring parameters ECG and HR and NIBP and PR and respiratory rate and SpO2 and body temperature5 Number of leads of ECG12-lead interpretation for ECG 4 Number of leads analyzed for ECG in single time Adult reusable Probe type Number of channels for temperature 2 Duration of alarm silence is 300 sec USB port Connectivity provision with Central Nursing Station LED display Display Size 12 inch Inbuilt thermal Recorder Resusable SpO2 probe Adult Number of adult probe 2 Number of pediatric probe 2 Number of neonatal probe 2 ECG cable 5 lead Number of ECG cable 2 Accessories to wall mount the monitor Type of battery backup Ni MH Backup time 120 minutes Warranty 2 years | 4 | Nos | Ambala | 15 |
| 5 | AED | Automatic external defibrillator should be fully automated using biphasic technology as per manufacturer recommendations energy level in joules to deliver shock energy complying with latest guidelines of AHA and must be upgraded to any future changes
Adult Disposable Electrode Pads 2 nos and Paediatric Disposable electrode pads 2 Nos are to be supplied for each unit of AED AED have an LCD screen that display text prompts and ECG on screen Must provide both visual and audible prompts on CPR complying with latest AHA guidelines AED shall be battery operated AED Battery shall be non rechargeable, disposable and easily replaceable battery Warranty 5 years | 4 | Nos | Ambala | 15 |
| 6 | ILR | Material of Construction of body should be Prepainted Galvanised Steel Net Vaccine Storage Capacity minimum 130 liteWarranty 2 year 99 percent of pure copper coil of Suction tube and Freezer tube and Condensing tube
Chest Door Automatic Voltage Stabilizer Audio visual alarm if Violation of temperature range less than 2C and more than 8C Corrosion resistant material,Appropriate Provision for drainage for the waste water Specially Integrated Ice lining LED display Microprocessor based temp control | 2 | Nos | Ambala | 15 |
| 7 | ECG MONITOR 6 CHANNEL | 6 Number of channels Built in Rechargeable Battery 50 ECG or 1 hour of continous rhythm recording on single charge The individual patient lead should be change without replacing the whole patient cable assembly Leads which is in ECG machine should be able to acquire simultaneously and interpret them 12 Operating modes Automatic Manual and Rhythm ECG machine should acquire lead ECG for both adult and pediatric patients The ECG machine should have facility to show lead fail indication The ECG machine should have facility to show lead reversal indication The ECG machine should have facility to show the impedance to quality check of connection Recorder speed 10 mm per sec Availability of latest interpretation software ECG machine should have full screen preview of ECG report for quality assessment checks prior to print 3 YEAR WARRANTY | 3 | Nos | Ambala | 15 |
| 8 | I GEL SUPRAGLOTTIC AIRWAY SIZE 3 | size 3 Single use disposable Airways device should deliver consistently very high intermittent positive pressure ventilation Device should be easy to insert and clean the contents of the pharyngeal cavity instantly Device should not inflate the stomach during IPPV Device should have attachments for suction to keep sump area clear
Device should have bite block for safety Airways device must provide advanced airway opening for superior patency of seal increased protection against gastric overflow Advanced self sealing variable pressure cuff Expanding membranous cuff produce a seal which increases proportionally with increasing airway pressure during IPPV Device should have large distal aperture locates at upper esophagus and open into sump cavity for easy drainage of gastric fluid | 4 | Nos | Ambala | 15 |
| 9 | I GEL SUPRAGLOTTIC AIRWAY SIZE 4 | size 4 Single use disposable Airways device should deliver consistently very high intermittent positive pressure ventilation Device should be easy to insert and clean the contents of the pharyngeal cavity instantly Device should not inflate the stomach during IPPV Device should have attachments for suction to keep sump area clear
Device should have bite block for safety Airways device must provide advanced airway opening for superior patency of seal increased protection against gastric overflow Advanced self sealing variable pressure cuff Expanding membranous cuff produce a seal which increases proportionally with increasing airway pressure during IPPV Device should have large distal aperture locates at upper esophagus and open into sump cavity for easy drainage of gastric fluid | 4 | Nos | Ambala | 15 |
| 10 | I GEL SUPRAGLOTTIC AIRWAY SIZE 5 | size 5 Single use disposable Airways device should deliver consistently very high intermittent positive pressure ventilation Device should be easy to insert and clean the contents of the pharyngeal cavity instantly Device should not inflate the stomach during IPPV Device should have attachments for suction to keep sump area clear
Device should have bite block for safety Airways device must provide advanced airway opening for superior patency of seal increased protection against gastric overflow Advanced self sealing variable pressure cuff Expanding membranous cuff produce a seal which increases proportionally with increasing airway pressure during IPPV Device should have large distal aperture locates at upper esophagus and open into sump cavity for easy drainage of gastric fluid | 2 | Nos | Ambala | 15 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_5806904.pdf
GEM_BID
boq_med_eqpts_for_pdf_2023-12-27-18-54-07_5fab55b98a267720f845cef4c99feae1.pdf
BOQ
boq_med_eqpts_2023-12-27-18-54-07_284df3ef57a3f998854bb70d054708f2.csv
BOQ
affidavit_c3e58654-595a-4349-87e21703939086547_2136fieldhospital.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .