Name of Work :- Empanelment for appointment of contractor for Retrofitting, Refurbishment and Structural
Strengthening work of various healthcare structures across Gujarat State.
Item Description Unit Rate
RCC Rehabilitation Work
Rehabilitation of existing RCC members up to 25 mm thickness such as slabs, beams, columns and other structural elements
at all levels, internally and externally, including provision of engineered double scaffolding with suitable bracing, working
platforms and necessary connections, complete as directed by the Engineer-in-Charge.
The work shall include careful removal/chipping of loose, damaged and cracked concrete up to approximately 6 mm beyond
exposed reinforcement, cleaning of concrete surfaces and rusted reinforcement by mechanical wire brushing, air blowing or
water jetting, and disposal of all dismantled debris to an approved dumping location with all leads and lifts.
Exposed reinforcement shall be treated with an approved anti-corrosive rust remover such as Rusticide (Sunanda Speciality
1 Coatings Pvt. Ltd.) or equivalent, strictly as per the manufacturer's recommendations. A protective cement slurry coat using Sqm
Polyalk Fixoprime or equivalent shall then be applied to the reinforcement.
For proper bonding, an approved bonding coat such as Polyalk EP or equivalent shall be applied to the prepared concrete
surface. Subsequently, polymer-modified cement mortar, up to 25 mm thickness in multiple coats, shall be applied to the
RCC members using approved materials such as Polyalk EP, MasterEmaco S-348, Lanko 732 or equivalent, including curing
and finishing, all complete as per approved specifications and manufacturer's instructions.
Item Description Unit Rate
Drilling hole of required diameter and depth as directed for fixing of Rebars using hammer drill.Including necessary
scaffolding , Cleaning the hole using mechanical air blower, water jetting etc.Providing & fixing rebar in the drilled hole using
approved make Chemical grout and sealent with necessary scaffolding , staging, labour , tools , and equipments etc.
2 complete and the work shall be carried out by the technical workmens/agency approved by the manufacturer and under
technical supervision of Manufacturer of Injection grout.etc. complete as directed by Engineer-in-charge.
2a For 8 & 10 mm. dia.bar -Depth up to 120 mm Nos.
2b For 12 mm. dia.bar -Depth up to 160 mm Nos.
2c For 16 mm. dia.bar -Depth up to 250 mm Nos.
2d For 20 mm. dia.bar -Depth up to 300 mm Nos.
Providing TMT Bar FE 500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto
floor two level.
Item Description Unit Rate
RCC Member Rehabilitation
The work comprises rehabilitation and strengthening of existing RCC slabs, beams, columns and other structural members up
to 70 mm thickness at any height, as directed by the Engineer-in-Charge. It includes providing engineered double scaffolding,
working platforms and necessary temporary structural propping/jacking arrangements for relieving superimposed loads and
ensuring safety during rehabilitation.
The existing damaged, cracked, loose, spalled and deteriorated concrete shall be carefully removed up to sound concrete,
exposing reinforcement all around. Reinforcement shall be mechanically cleaned of rust, dirt and loose material, followed by
application of an approved anti-corrosion treatment. Additional reinforcement, including cutting, bending, fixing, dowels,
4 hooks, chairs, spacers and binding, shall be provided as required. Sqm
Bonding coats shall be applied to existing concrete and treated reinforcement using approved polymer-based bonding
materials. The damaged RCC sections shall then be restored in layers using approved Polymer Modified Repair Mortar,
mechanically mixed and properly compacted by hand packing, dashing or shuttering, to match the original member profile
and required thickness. The work includes all necessary scaffolding, protection, cleaning, curing, finishing and disposal of
debris, complete as per approved specifications, manufacturer's recommendations and directions of the Engineer-in-Charge.
Excavation for foundation up to 1.5 m depth including sorting out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Filling available excavated earth (excluding rock ) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm.
In depth consolidating each disposited layer by ramming and watering.
Providing and laying cement concrete 1:4:8 (1-Cement : 4-coarse sand : 8- hand broken stone aggregates 40 mm nominal size
) and curing complete excluding cost of form work in (A) Foundation and Plinth (upto 10 ton)
Item Description Unit Rate
Providing and laying cement concrete 1:1.5:3 (1-Cement : 1.5-coarse sand : 3- stone aggregate 20 mm nominal size ) and
8 curing complete excluding the cost of form work and reinforcement for reinforced concrete work in ( A ) Foundations, Cum
footings, Base of columns and Mass concrete. (upto 10 ton)
Providing and laying of polymer modified micro concrete like Sika make "SikaRep-Microcrete-4", Sunanda Chemical make
"Polycrete-A/B", Parex Group make "Lanko-701",BASF make "MasterEmaco S346 or equivalent material of Krishna Conchem
blended with washed saturated surface dry (SSD), graded, low absorption, high density, aggregates of size 5mm to 12mm at
50% by weight of micro concrete and water as per manufacturer's specification and pouring into the form work using suitable
arrangement or if required using pumping device for uniform flow of Micro concrete. The side shuttering can be removed
after 3 days and the bottom shuttering after 7days ensuring proper bond between the micro concrete and existing concrete
Item rate is inclusive of the material, necessary scaffolding all labour, supervision, tools and tackles, scaffolding and
transportation, curing for minimum 10 days etc. complete as per specification and as directed.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
10 propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same Sqm
for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and
propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same
for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular
Polygonal in plan.
Item Description Unit Rate
Providing and executing injection / pressure grouting in cracks in the parent concrete/brick work or in honey-comb area by
fixing-up PVC or metallic grout-nozzles on line of crack in concrete/masonary at a distance not exceeding 300mm injecting
with the help of grout-pump working at a pressure of 3.00 kg/cm2,Pressure grouting to be done using low viscous 2-
component epoxy gcrack injection material " Lanco 721 "of Parexgroup , "Conbextra EP 10 ( M )" of Fosroc, " Concresive
12 1315" of BASF or equivalent make shall be done in a sequence starting from lowest grout-hole and procedding to the next Nos.
upper one, sealing the grout nozzles temporarily, on the next day repeating the grout sequence once more before cutting
and sealing the nozzles permanently.Finally patching up the plaster with cement mortar ( 1: 3 ) proportion using plasticiser to
increase workability, curing with water sprinkler for minimum three days including finishing the edges of the patch/groove
with birla putty/plaster paris, for even matching with the adjacent plaster area including necessary scaffolding etc.complete.
Strengthening of structural component by confinement using CFRP composite system: Strengthening structural elements
with non metallic composite fibre wrapping system comprise of unidirectional carbon fibre sheet Nitowrap EPCF (Fosroc)
(300,450 & 600 gsm) and compatible saturant Nitowrap 410 of (Fosroc) by dry layup system including surface preparation by
first providing 300 mm bend using polymer modified mortar as master emaco S 348 of BASF make or Renderoc SP40 of
Fosroc, allow to cure and grinding substrate to avoid undulations,including necessary scaffolding , cleaning it with wire brush,
removing oil, laitance if present, rounding sharp edges to minimum 25 mm radius etc. complete including profiling. Applying
compatible primer Nitowrap 30 (Fosroc) on prepared substrate, filling the holes and uneven surface with thixotropic putty
Nitocote VF (Fosroc), cutting of fibre sheet to required sixe mixing of saturant and applying saturat on primed surface,
wrapping the fibre sheet to structural element at approved orientation using temping roller to avoid air void etc. repeat the
same procedure for multiple layers with the interval of minimum 8 hrs. of second coat. Applying 2nd | final coat of saturant
of internal of minimum 12 hrs. rectify air voids if any, and installation fibre anchors at spacing of 900 mm along the length of
brand by drilling through hole in pier section and fan shape of 150 mm over the wall.(a) 450 GSM
Item Description Unit Rate
FRP Laminates for structural strengthening - (Carbon Fibre Laminates) :-
Providing and applying Nitoplate CPS - Carbon Fiber FRP Pultruded Laminate strips of 1.4mm thick and 50mm width to the
prepared substrate using thixotropic epoxy adhesive. The FRP laminate used shall be of zero degree unidirectional fibers
having volumetric fiber content of 68%, fiber density of 1.5 g/cc and shall have tensile strength of 3000 MPa ; tensile
modulous of 165 GPa and ultimate elongation of 1.7%. The thixotropic epoxy bonding adhesive shall be applied at 1mm
14 thickness on the substrate and 2mm thickness on the laminate. The adhesion of the entire system(Laminate and adhesive Rmt
combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541. The adhesive used shall have tensile
modulous > 2700 MPa (ASTM D638) ; flexural modulous > 48000 MPa (ASTM D790 ) ; Elongation > 2.5% & Glass Transition
TemPerature > 100 deg C (ASTM E 1356). The ends of the laminates shall be anchored suitably.,including necessary
scaffolding etc complete. Product used shall have CE (CE-29842) marking and compliance according to Construction Products
Directive 89/106/EEC (CPD)
For Strengthening of Masonry Structures: FRP Grids for structural strengthening -
(Carbon Fibre Grids)
Providing and applying High Strength Carbon Fiber Mesh Nitowrap CF(CS) of 250 GSM on wet mortar and application of
second layer of mortar and float to finish followed by curing.The repair mortar used shall be single component and shall be
mixed with water at water powder ratio of 0.18 and shall have drying shrinkage < 1000 microstrain as per ASTM C 157-93;
compressive strength > 40 MPa ; Flexural Strength > 7 Mpa as per ASTM C 348, bond strength > 6 MPa as per ASTM C
Repair mortar used shall have CE (CE-29842) marking and compliance according to Construction Products Directive
89/106/EEC (CPD). Carbon Fiber Mesh shall have grid size of 20mm ; areal weigth of 250 g/sqm; tensile strength of 150 kN/m
; Elastic Modulous of >230000 MPa ; bond strength > 1 MPa as per ASTM D4541 , including necessary scaffolding etc,
Item Description Unit Rate
Galvanic sacrificial Anodes for patch repairs by Point Anodes:
Provide and install sacrificial zinc anodes of Fosroc Galvashield XPI to prevent initiation of corrosion of steel reinforcement in
chloridecontaminated or carbonated concrete or new construction. Zinc mass should be Min. 60 g/unit or More and the zinc surface area
and spacing of anodes should be selected/designed in a way to achieve the target service life of 10 years. The quality of zinc should be in
compliance with ASTM B418-95a, Type I, die-cast around steel tie-wires (in case of more than one tie wire they should be well seperated)
and encased in a highly alkaline cementitious mortar (encapsulating mortar) with a pH of 14 or greater. The encapsulating mortar should
not have sulphates, chlorides, bromides or any other elements corrosive to steel. The encapsulating mortar should have interconnected
and fine pore structure to dissolve, transport and accommodate zinc corrosion products away from the zinc surface without causing
additional stress to the cover concrete, and maintain a pH > 14 at the immediate vicinity of uncorroded zinc for the desired service life.
Anode units shall be supplied with integral well-separated tie wires without splices (in case of more than one wire) and with loop ties for
directly tying to the reinforcing steel. For patches in grid pattern or periphery of patches with 4-6 anodes/m2 area of concrete, the max
spacing can be 600 mm. The anode size and shaping shall deliver a minimum current density to the steel adjacent to the repair of
mA/m2 of steel surface area at the end of the design life taking into account an anode aging factor calculated from previous field
installations and the in-service environment. Anodes should meet the target service life, which can be estimated using Galvanic Anode
Performance (GAP) test developed at IIT Madras for severe exposure condition (high humid and high chloride conditions).The anodes
shall be covered with bed-mortar of resistivity less than 50 kOhm-cm or similar to the parent concrete on the cleaned steel reinforcement
as per manufacturers specification before applying passivation coating. All necessary design calculations for spacing of anodes,
installation training, installation confirmation, monitoring of set of anodes to confirm current from anodes as per ISO 12696 or as per the
design, etc. shall be carried out by a NACE Certified CP Technician, CP2 or higher, complete at all heights and including necessary
scaffolding , including of all materials, labour, tools, plants and machineries as directed by Engineer-incharge and/or consultant.
Concrete Curing Compound:
The acryic emulsion modified and water based concrete Curing Membrane (such as Concure AB or equivalent) and applying
17 immediately after the repair/concrete gets finished, the membrane shall be sprayed over concrete finished area without any Sqm
gap or pinhole. The cost of all materials. tools, including necessary scaffolding and all labour charges are included. completed
as specified and directed by EIC.
Item Description Unit Rate
Providing and filling of non structural cracks by exposing the line of crack as per actual requirements at site and removing all
the loose material , dirt etc. from the crack by brush. The crack shall be made moist by applying water in the groove by brush.
18 The same groove shall be filled withtready mixed paste" POLYFILL-AR" of Sunanda Speciality Coatings Pvt. Ltd. crack-X of Rmt
Dr.Fixit or Equivalent and making good the walls as per manufacturer specification and including necessary scaffolding as
required by the Engineer-in-charge.
19 Demolition and disposable of unserviceable materials with all lead and lift. (ii ) Un reinforced Cement Concrete Cum
Providing and laying concrete 1:2:4 ( 1 cement :2 coarse Sand: 4 Graded Stone Aggregate 20 mm nominal size ) in proper
20 gradient on terrace slab as directed by Engineer-in-charge to have proper slope for draining rain water including finishing top Cum
with floating coat of neat cement
Providing and applying " Concentrate concrete waterproofing By Crystallization" to be supported by at least two international
Test reports showing clear scanning Electron Microscopinc (SEM) Photographs of dandified and mature crystals formation to
plug all the capillarytracks and pores of the concrete permantly and permeability tested as per IS 2645 (2003). The treated
concrete should exhibit higher compressive strength as per IS 516 (2008) . The product should demonstrate the reduction of
chloride penetration in treated concrete by 72 % as per ASTM C 1202-05 Conducted by a National Accreditation Board for
21 Testing and Calibration Laboratories (NABL) accredited laboratory. The Product must have passed the overall migration test Sqm
as per 21 CFR 175-300 of US-FDA conducted by central food Technological Research institute (CFTRI). The product should be
able to supress the chemical erosion to 1/8 of standard samples when subjected to a 5% sulfuric acid solution environment.
The poduct to be listed as crystalline Waterproofing in at least three ICC-ES EVALUATION REPORT INDEX and it should be
green certified under any Ecolable program,. Work shall be carried out as per the technical details provided in the technical
section of the tender / Aprroved method of waterproofing accepted by Engineer in Charge. ( Plan area shall be measured )
Item Description Unit Rate
NITOPROOF 600PF - TERRACE/PODIUM
Providing and carry out waterproofing treatment to sound, moisture free concrete surface using Nitoproof 600PF- Liquid applied single
component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm which supplied in 25 kg drum. System
includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection
grouting at leakage points and construction joints using cement slurry modified with Cebex 100-Plasticised expandive grout admixture
supplied in 225 gm pouch, application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet
using Conbextra GP2 - Non-shrink cementitious grout followed by application of Nitoproof WB Primer and final application of two coats of
Nitoproof 600PF coverage @ 2.0 kg/m2 from 25 kg drum to achieve 1.5 mm thickness in two coats complete including all tools and
22 tackles as per manufacturer’s specification. Nitocote 600PF cured material shall shall be having crack bridging of > 2 mm, Elongation Sqm
(ASTMD 412) > 600 %, Tensile Strength (ASTM D412) – 2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, 85% Min Solid
Content, Tear Resistance (ASTM D624-00) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 60, Water vapour transmission 2.3 mm film -
0.6 g/m2/hr, Water Permeability @ 5 Bar (BS EN 12390)-Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C, Viscosity-50-100p,
Specific Gravity-1.5 +/-
HSE Guidelines: Some people are sensitive to resin systems. Impervious gloves and barrier cream should be used when handling these
products. Eye protection should be worn. If accidental eye contamination occurs, wash thoroughly with plenty of water and seek medical
advice. If contact with skin occurs, it must be removed before curing takes place. Wash off with an industrial skin cleaner followed by
plenty of soap and water. Do not use solvent. Ensure adequate ventilation when using these products
23 Providing and laying 300 GSM Geotextile on terrace over polyurethane coating to protect the coating. Sqm
Item Description Unit Rate
Providing and applying two coats of Hybrid Polymer flexible acrylic coating of Sovacryl K-10 of Parex(Sika India) or approved
equivalent brand with under coat adhesion promotor priming coat of Flow Prime WB of Parex( Sika India ) or approved
equivalent make on existing china mosaic / IPS. Cleaning the existing surface throughly, chase open the crack available at
surface and fill the same with crack filler material of approved brand. After application of 1st coat of Sovacryl K-10 on
Flowprime WB ,a fibre glass mesh of 45 GSM to be sandwiched between 1st & 2nd coat of Sovacryl K-10. The products shall
be applied in strict accordance with the manufacturer's specification. (The crack filling shall be paid under relevant item).
Providing and applying Premium Acrylic emulsion,Heat Insulating, Anti Carbonation, Anti-Algae, Water Proof exterior
protective coating "SUNEXT-8" of Sunanda Speciality PVT. Ltd. Or Dr. Fixit or equivalent of required colour and shade as
approved by Engineer-in-charge. Mixing with water in the volumetric proportion 1:1/2 ( 1 SUNEXT-8 : 1/2 potatble water )
after removing the dirt , loose particles , flaking paints from the walls/terrcae surface as per the Manufacturer specification
and as per the direction of Engineer-in-charge.
(a) Two or more coats
Brickwork using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1-Cement:6-fine sand) (B)Conventional
Brickwork using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Super Structure
above Plinth level upto floor two level (B)Conventional
Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement
mortar 1:4 (1-Cement : 4 -coarse sand ) in super structure up to floor two level (B) Conventional.
Item Description Unit Rate
Providing and fixing FRP frame size 100x50 mm and 28mm thick FRP depress panel shutter having extra reinforcement on
sides & edges in Gel coat finish. The core of the shutter & frame is to be filed up with injected fire retardant grade
29 polyurethene foam done in situ alongwith embedded wooden pieces for stiffening & also taking hinges & fintures. The whole Sqm
FRP frame & shutter is to be water proof weather proof, termite proof & resistance to mild acid/alkali. Rates are to be
inclusive of S.S hinges with necessary screws & alluminium fixtures & fastenings & fastener sleeve.
Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings
make PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be concelled as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure polythene pipes of the following outside Dia.
33 Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and Rmt
Item Description Unit Rate
Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia.
34 Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and Rmt
floor.(G)110 mm
Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end
plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of
the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls
as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end
plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage
system pipe line, pipe hall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of
the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls
as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
Providing and laying polished Kota stone slab flooring over 20 mm (Average)thick base of cement mortar 1:6 (1-cement:6-
37 coarse sand) or L.M.1.1.5 (1-Lime putty:1.5-coarse sand)laid over and jointed with grey cement slurry mixed with pigment to Sqm
match the shade of slab including rubbing and polishing etc. complete. (A) 25 mm thick.
Item Description Unit Rate
Providing and laying 24" x 24" Vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 (1 cement :
6 coarse sand) or L.M 1:1.5 laid on new surface or fixing on existing flooring by adhesive material including dismentalling of
existing flooring and jointed with colour cement slurry including finished with flush pointing & cleaning the surface
etc.complete For light shade.
Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and landing laid on a bed of 12mm thick cement
mortar 1:3 (1-cement : 3 - coarse sand ) finishing with flush pointing in white cement.
Providing and laying coloured glazed tiles of the size 300 mm x 200 mm x 8 mm / 300 mm x 450 mm x 8 mm in skirting, risers
of steps and dedo on 10 mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with white cement slurry.
Provoding and fixing flush door shutters, solid core construction with frame of first class hard wood with cross board and face
41 veneer or plywood face panels, including anodised alluminium butt hinges with necessary screws. (B) Non-decorative type Sqm
and block board core anodised alluminium butt hinges in flush door shutters (2) 35 mm thick.
Providing and fixing window having extruded aluminum Colour Powder Coated section frame main outer size 63.50 x 38.10 x
1.95 mm (of Jindal Section no : 4605, @ Wt 1.094 Kg / Rmt ) , horizontal two track member size 61.85 mm x 31.75 mm x
mm (of Jindal Section no : 8687 @ wt. of 0.695 Kg/mt ) ,vertical member of size 61.85 mm x 31.75 mm x 1.30mm (of Jindal
Section no : 8758 @ wt. of 0.659 Kg / mt )with sliding shutters of horizontal member size 40 mm x 18 mm x 1.29 mm (of
Jindal Section no: 8949 @ wt. of 0.456 Kg /mt ) , vertical member of size 40 mm x 18 mm x 1.29 mm (of Jindal Section no :
8947 @ wt. of 0.456 Kg /mt /Section 8948 , @ Wt. 0.457 Kg/mt)with 5 mm thick transparent bronze colour tinted float glass
with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc
complete for window.
Item Description Unit Rate
Providing and fixing standared extruded of alluminium section of size 63mm x 38.10mm x 1.2mm , @ Wt. 0.643 Kg/mt with
43 colour Powder Coated alluminium frame for ventilation with 5 mm Sqm
thick frosted glass as details etc complete for Ventilation.
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacings and
frame alround, square or round bars with round headed bolts and nuts or by screws (A) Plain Grill.
Rubbing and polishing on existing kota stone floor,skirting etc. including cleaning the floor etc. complete as per direction of
Engineer-in-Chrage.
Removing and scrapping of old deteriorated plaster of any thicknerss from masonary/RCC member including stacking of
serviceable material and disposal of unserviceable material from site of work with all lead and lift.
Providing15 mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering
47 upto floor two level and finished even and smooth in (ii)Cement mortar 1:4 (1-cement :4-sand )inclding finishing with floating Sqm
coat of neat cement slury.
20 mm thick sand faced cement plaster on walls upto height 10 metres above ground level consisting of 12 mm thick backing
coat of C.M.1:3 (1-cement : 3-sand ) and 8 mm thick finishing coat of C.M. 1:1 ( 1-cement : 1-sand ) etc. complete.
Painting two coats (excluding priming coat) on previously painted steel and other metal surfaces with synthetic enamel paint,
brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter .
Painting two coats (excluding priming coat) on previously painted wood and wood based surfaces with enamel paint to give
an even shade including cleaning the all dirt, dust and foreign matter.
Item Description Unit Rate
Distempering (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on
wall surfaces to give an even shade, over and including applying two coats of Birla (white cement based) or Asian (acrylic
lapy- putty) or equivalent & two coats of primer of approved brand and manufacture after thoroughly brushing the surface
and other foreign matter and also including preparing the surface even and sand parpered smooth.
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade
after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete.
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thick with grade of concrete M300
pnumatic compressed / vibrated mechanically and as per approved design Confirming to IS 15658 : 2006 including 35 mm
Sand layer for levelling and filling the joint with sand in proper line and level as per guidlines of IRC : SP 63-2018 etc.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm
54 length,30cm height and 15cm thick of M200 grade concret as per approved design and including Rmt
excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
Making a Gargoyle for draining rain water from terrace by providing and fixing 25 mm thick double side polished kota stone
including groove at bottom at out side edge to act like drip mould to drain rain water . Gargoyle should be provided by
making hole in existing perapet wall of required size and by providing double side polised kotah stone at bottom of size 450 x
600 mm at bottom and at both sides kotah of length 600 mm and height 150mm upto perpet out side and then slanting upto
10mm. At top 450 x 300 mm kotah to be provided in perapet wall . These should be fixed with cement mortar 1:1( 1 cement :
1 sand ) or by adhesives etc all complete as per direction of Engineer-in charge.
Item Description Unit Rate
I / We am / are willing to carry out the work at _________________ % above / below percent (Should be written in figures and words) of the estimated rates
mentioned above. Amount of my/our tender works out as under:
*Estimated Amount *Estimated Amount
Put to Tender Rs.____________________________________ Put to Tender Rs.__________
(1) Total Tendered amount
(2) Rebate on above Tendered amount (if any) (% In figure) ________ (% in Words)
(3 ) Net tendered amount (1 - 2)
(4) Net Tendered Amount (In words): Rupees
Item Description Unit Rate
Signature of Contractor with Seal Signature of Contracting Authority with Seal
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD_ARC Retro 26-27 R1.pdf
Schedule B.pdf
Specification ARC Retro 26-27.pdf
Tender Details-70-02.pdf
01-Make List-4171-06-10-2017.pdf
02-Make List - Civil Items-05-02-2020.pdf
20-Special Conditions-27-05-2026.pdf
Building-Specification.pdf
Ele-List of Approved Products-FINAL.pdf
GRs and Conditions-11-06-24.pdf
Performance Bond and Bitumen date.pdf
Standard Specification for Electrical Work.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .