Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹1.2 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.2 Cr+₹3.0 L (2.53%)Rejected-Finance | ₹1.2 Cr+₹3.0 L (2.53%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹1.2 Cr+₹4.7 L (3.97%)Rejected-Finance | ₹1.2 Cr+₹4.7 L (3.97%) | L3 | Rejected-Finance Being not lowest |
| 4 | L4₹1.2 Cr+₹5.0 L (4.20%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.2 Cr+₹5.0 L (4.20%) | L4 | Rejected-Finance Being not lowest |
| 5 | L5₹1.3 Cr+₹11.8 L (9.90%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹1.3 Cr+₹11.8 L (9.90%) | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | kailu construction co L4 | SATISH AND CO L1 | M/s Trade Linker Associates L2 | R D Bansal L5 | JCC ENGINEERS PRIVATE LIMITED L6 | Continental Enterprises L7 | PROACH ASSOCIATES BUILDERS & ENGINEERS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing, & commissioning outdoor type copper wound Power transformer having no load voltage ratio at rated voltage 33/11 KV, 6.3 MVA oil immersed, naturally cooled 3 phase 50 Hz, vector group DYN-11 and ON Load tap Changer(OLTC) (Tapping Range +5% to -15% in step of 2.5% with remote tap cubical changer (RTCC) Panel & Automatic Voltage Regulator (AVR) with vector group Dyn-11 tap changing switch (9 position), on HT side to very secondary voltage, connected internally and hand operated ON Load tap changing switch, star Delta connected internally with HV coil, copper double wound, LV side provided with 3 phase and neutral with the temperature rise not exceeding 50 degree C by thermometer in oil and 55 degree Celsius by resistance with first filling of oil as per IS grade 335 and transformer conforming to IS 2026 "class A" all as directed and specified. The Manufacturer must have ISO Certificates. Paint should be PU. Painting process should be done in environment friendly painting booth with heaters for curing of paint. The following fittings and accessories including first fill of transformer oil necessary mounting on PCC floor mounted as per manufacturer's recommendations and specifications;
(a) Lifting lugs, Top cover lugs & jacking Pad.
(b) Earthing Terminals.
(c ) Conservator with oil gauge Glass, Oil filling hole with plug and drain plug.
(d) Transformer Drain valve
(e) 04 Nos Bi-directional plain/Flat rollers
(f) Explosion Vent with Diaphragm
(g) Thermometer Pocket
(h) Air Vent Plug
(j) First Fill Silica get Breather
(k) Rating & Diagram Plate, Inspection cover,. Terminal Making Plate | 1 | EACH | 94,00,000 ₹94,00,000 | 89,09,700 ₹89,09,700 Lowest | 93,00,000 ₹93,00,000 | 1,05,70,000 ₹1,05,70,000 | 98,00,000 ₹98,00,000 | 1,08,00,000 ₹1,08,00,000 | 96,00,000 ₹96,00,000 |
| 1.01(l) Cooling Radiators (m) HT Termination - Bare Bushing. (n) Provn of LT Termination box for connecting LT output through rated cables etc. as catered in CCE work provisions complete all as drawings approved by GE. (o) LV Neutral Bushing brought out for external earthing. (p) First Fill of EHV grade Transformer Oil (q) Buchholz Relay with Contracts for Alarm & Trip Contacts (r) Magnetic Oil Level Gauge with Alarm Contacts (s) Oil Temp indicator with Alarm & Trip Contacts (t) Winding Temperature indicator with Alarm & Trip Contacts (u) Marshaling Box (t) No load losses - 6.0 kw (Max). (v) Full load losses- 43.0 kw (Max). (v) Impedance – 7.15% + IS Tol. (s) Pressure Relief Valve with Alarm & Trip Contacts. Notes: 1. Transformer Oil, shall be filled at site and the same shall be as per OEM recommendations and filling is to be done in the presence of Engineer-in-Charge. 2. The quoted rate is deemed to include removing of existing power transformer from the platform and depositing the same at E/M yard of GE Nagrota. 3. The rate shall also include replacement of HT/LT Bus bar terminals of suitable size with clamps, nut bolts etc at site. | ||||||||||
| 2.00 | Supply, installation, Testing, Commissioning of Oil Cooled, Copper wound, Step down "BIS marked & BEE star labelled " transformer of capacity 315 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3, phase 4 wire,50 C/S oil immerse, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at +/-2.5 %to +/-5 % & +/- 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dilectric strength not less than 55 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 having total losses @ 50% load 955W & total losses @ 100% load 2750W. Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items complete all as specified and directed by Engineer-in-charge. | 2 | EACH | 15,00,000 ₹30,00,000 | 15,00,000 ₹30,00,000 | 14,55,000 ₹29,10,000 | 12,55,000 ₹25,10,000 Lowest | 16,85,777.5 ₹33,71,555 | 15,60,000 ₹31,20,000 | 13,90,000 ₹27,80,000 |
| 2.01(i) Name, rating & diagram plate (ii) 7 positions Off circuit tap changing switch (iii) Earthling terminals (iv) Lifting lugs (v Oil drain valve with plug (vi) Oil filter valve with plug (vii) Conservator with oil filling hole (viii) Thermometer pocket (ix) Air release plug (x) Silicagel breather (xi) Removable inspection opening (xii) Explosion vent (xiii) Transformer platform as per manufacturer design with chain link fencing of size as approved by GE along all the sides of platform supported by providing angle iron of size 50 x 50 x 6mm at all corners including supplying and fixing danger notice plate on all the sides of chain link fencing and painting the fencing and angle iron with black synthetic enamelled paint. Notes: 1. The quoted rate is deemed to include removing of existing power transformer from the platform and depositing the same at E/M yard of GE Nagrota. 2. The rate shall also include replacement of HT/LT Bus bar terminals of suitable size with clamps, nut bolts etc at site. | ||||||||||
| 3.00 | M&L for earthing complete with galvanized mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground preferably in vertical position (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level, connected to galvanized iron strip 25 x 4mm by means of nuts, bolts, check nuts and washers of GI or steel including PCC (1:2:4) type B-1, precast RCC cover slab of size 550 x 550 x 75mm, XPM reinforced not less than 1.60 Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth strip protection upto 5m length, charcoal, common salt complete all as shown in electrical plate No 3 of MES SSR 2009 Part-I, connected to equipment and testing on completion for desired result complete all as specified and directed by Engr-in-charge. | 8 | EACH | 6,000 ₹48,000 | 4,500 ₹36,000 Lowest | 4,800 ₹38,400 | 6,000 ₹48,000 | 5,000 ₹40,000 | 7,000 ₹56,000 | 5,000 ₹40,000 |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
22 Nov 2025, 6:00 pmClosed
CWE NAGROTA
HQ CWE Nagrota c/o 56 APO
SPECIAL REPAIR/REPLACEMENT OF BER POWER AND DISTRIBUTION TRANSFORMERS ASSOCIATED WITH EXTERNAL ELECTRIC SUPPLY UNDER GE NAGROTA
2025_MES_736586_1
CWE/NGT-35/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAGROTA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE NAGROTA
₹2.1 L
Yes
3 Feb 2026
24 Oct 2025
25 Nov 2025
24 Oct 2025
22 Nov 2025
15 Nov 2025
24 Oct 2025 - 8 Nov 2025
Supply, install, testing, & commissioning outdoor type Power transformer having no load voltage ratio at rated voltage 33/11 KV, 6.3 MVA oil immersed, naturally cooled 3 phase 50 Hz, vector group DYN-11 and ON Load tap Changer(OLTC) (Tapping Range +5% to -15% in step of 2.5% with remote tap cubical changer (RTCC) Panel & Automatic Voltage Regulator (AVR) with vector group Dyn-11 tap changing switch (9 position), on HT side to very secondary voltage, connected internally and hand operated ON Load tap changing switch, star Delta connected internally with HV coil, copper double wound, LV side provided with 3 phase and neutral with the temperature rise not exceeding 50 degree C by thermometer in oil and 55 degree Celsius by resistance with first filling of oil as per IS grade 335 and transformer conforming to IS 2026 "class A" all as directed and specified. The Manufacturer must have ISO Certificates. Paint should be PU. Painting process should be done in environment friendly painting booth with heaters for curing of paint. The following fittings and accessories including first fill of transformer oil necessary mounting on PCC floor mounted as per manufacturer's recommendations and specifications; (a) Lifting lugs, Top cover lugs & jacking Pad. (b) Earthing Terminals. (c ) Conservator with oil gauge Glass, Oil filling hole with plug and drain plug. (d) Transformer Drain valve (e) 04 Nos Bi-directional plain/Flat rollers (f) Explosion Vent with Diaphragm (g) Thermometer Pocket (h) Air Vent Plug (j) First Fill Silica get Breather (k) Rating & Diagram Plate, Inspection cover,. Terminal Making Plate (l) Cooling Radiators m) HT Termination - Bare Bushing. n) Provn of LT Termination box for connecting LT output through rated cables etc. as catered in CCE work provisions complete all as drawings approved by GE. (m) LV Neutral Bushing brought out for external earthing. (n) First Fill of EHV grade Transformer Oil (o) Buchholz Relay with Contracts for Alarm & Trip Contacts (p) Magnetic Oil Level Gauge with Alarm Contacts (q) Oil Temp indicator with Alarm & Trip Contacts (r) Winding Temperature indicator with Alarm & Trip Contacts (s) Marshaling Box (t) No load losses - 7.5 kw + IS Tol. (u) Full load losses- 43.0 kw + IS Tol. (v) Impedance – 7.15% + IS Tol. (w) Pressure Relief Valve with Alarm & Trip Contacts
Supply, installation, Testing, Commissioning of Oil Cooled, Copper wound, Step down "BIS marked & BEE star labelled " transformer of capacity 315 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3, phase 4 wire,50 C/S oil immerse, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at +/-2.5 %to +/-5 % & +/- 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dilectric strength not less than 55 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 having total losses @ 50% load 955W & total losses @ 100% load 2750W. Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items complete all as specified and directed by Engineer-in-charge. (i) Name, rating & diagram plate (ii) 7 positions Off circuit tap changing switch (iii) Earthling terminals (iv) Lifting lugs (v Oil drain valve with plug (vi) Oil filter valve with plug (vii) Conservator with oil filling hole (viii) Thermometer pocket (ix) Air release plug (x) Silicagel breather (xi) Removable inspection opening (xii) Explosion vent (xiii) Transformer platform as per manufacturer design with chain link fencing of size as approved by GE along all the sides of platform supported by providing angle iron of size 50 x 50 x 6mm at all corners including supplying and fixing danger notice plate on all the sides of chain link fencing and painting the fencing and angle iron with black synthetic enamelled paint.
M&L for earthing complete with galvanized mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground preferably in vertical position (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level, connected to galvanized iron strip 25 x 4mm by means of nuts, bolts, check nuts and washers of GI or steel including PCC (1:2:4) type B-1, precast RCC cover slab of size 550 x 550 x 75mm, XPM reinforced not less than 1.60 Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth strip protection upto 5m length, charcoal, common salt complete all as shown in electrical plate No 3 of MES SSR 2009 Part-I, connected to equipment and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
TENDER35.pdf
Tender Documents • 0.93 MB
BOQ_824754.xls
BOQ • 0.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .