Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAdmitted-Finance | ₹18.4 L | L1 | Admitted-Finance |
| 2 | L2₹22.5 LAdmitted-Finance | ₹22.5 L | L2 | Admitted-Finance |
| 3 | L3₹24.4 LAdmitted-Finance 3 333 F M P ARCS VENGACHUVAD VAZHAKULAM P O MUVATTUPUZHA ERNAKULAM KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | ₹24.4 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Party failed to submit Financial turnover details and Attachment II B documents as specified in the tender |
| Sl No | Description | Qty | Unit | Nev Tech L2 | Linsta Services L3 | PEEJESS ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Erection,Termination and connection of the 4 way/6 way, 3ph, 415V Horizontal double door MCB Lighting DB Having 63 A, 4 pole Isolator as incomer and 6 no of 2 pole isolators of rating 40 A for each Quarters and One No. 6A MCBs for Providing Supply for Stair case area of each flats.
DB shall be mounted in suitable frame fabricated by MS angle frame (25 x 25 x 6), epoxy painted (primer + 2 coats) and properly fixed on wall by the contractor. The incomer PVC armoured cable (upto 4 X 50 sqmm) outgoing flexible copper cables of 4 sqmm, earth cables of size 2.5 sq mm for power circuit through 40 A DP to each quarters and out going for staircase shall be glanded /terminated and connected using suitable cable lugs /clamps /ties. All Required structural items, DB with DP/MCBs, flexible glands, suitable pvc pipes etc, shall be in the scope of the contractor. Existing in-put armoured cable can be used for main supply from Piller Box. If incomer cable length is not adequate for termination in DB, cable should be jointed with copper/aluminum flexible cable of size similer to incomer cable by proper lug/ferrules by providing suitable joint box near DB. This also be in the scope of the contractor.
APPROVED MAKE FOR DB AND MCBs: LEGRAND/ HONEYWELL/ L&T/ SCHNEIDER | 4 | NO | 15,000 ₹60,000 | 12,500 ₹50,000 | 12,000 ₹48,000 |
| 2.00 | Supply, Erection, Termination and connection of the 18 way, single phase, 230V Horizontal double door MCB lighting DB having 40A, 30 mA RCCB, 40A DP isolators as incomers SP MCBs -6 A-5 no and SP MCBs 16A -6 no single phase out going circuits.
LDB shall be mounted properly concealed on the wall by the contractor. Incomer for this DB should drawn through pipe size not less than 20mm from Main DB Fixed in the ground floor by suitable metal saddles spacing not less than 50 cm, 4 sq mm Phase and Neutral Wire and 2.5 Sq mm for Earth. All Required items for this Work Shall Be in the scope of the Contractor (Including the cementing and finishing of the wall after fixing of the DB)
APPROVED MAKE FOR DB , RCCBs AND MCBs:-LEGRAND / HONEYWELL/ L&T/ SCHNEIDER | 24 | NO | 8,500 ₹2.0 L | 10,000 ₹2.4 L | 8,000 ₹1.9 L |
| 3.00 | Open pipe Point wiring with individual control For light/Fan/Bell/Stair case lights/6 A modular plug sockets separately mounted for TV points/Modular switches, using Flexible copper cables 1.5 sqmm for control and neutral connection, Through pvc conduits of size not less than 20 mm using metal saddles with spacing not exceed 50 cm as per relevant drawings or instructions from FACT Engineer in Charge. The work shall include wiring along roof/beam/column/ceiling using clamps and drawing wires as required, preparation and fixing of modular switch boards, switches, cover plates, dummy plates, Etc fixing of ceiling roses on suitable junction boxes, modular step type regulators for fan, drawing of 1.5 sqmm earth wires of flexible copper wire of green color for body earthing of metal clad items, connecting, testing and commissioning. For wire length greater than 10 m shall be considered as one and half point. All the materials for this Work shall be in the Scope of the contractor( Selection of the switch boards in rooms shall be in the form of requirements to particular room for fans/lights/sockets etc).
(Supply to Switchbox from DB are considered as a Point, Also in case of any two way control of equipment is done also considered as two point)
APPROVED MAKE :
WIRE :- POLYCAB/ RR KABEL/ KEI/FINOLEX OF FR/FR-LSHS TYPE
SWITCH, SOCKETS,REGULATORS ETC :- LEGRAND- MYRIUS /HONEYWELL-HORIZON/SCHNEIDER-UNICA PURE/L&T-ENTICE
PIPE SHALL BE OF MEDIUM ISI MARKED | 1,000 | NO | 1,050 ₹10.5 L | 950 ₹9.5 L | 850 ₹8.5 L |
| 4.00 | Supply of 6A Modular Switches as spares for the work specified in Schedule No -3
(Brand and type of switches should be exactly same as the switches used for the work specified in Schedule No -3) | 200 | NO | 75 ₹15,000 | 90 ₹18,000 | 55 ₹11,000 |
| 5.00 | Supply of 6A Modular Sockets as spares for the work specified in Schedule No- 3
(Brand and type of sockets should be exactly same as the sockets used for the work specified in Schedule No -3) | 36 | NO | 140 ₹5,040 | 140 ₹5,040 | 100 ₹3,600 |
| 6.00 | Supply of Modular step type regulators as spares for the work specified in Schedule No - 3
(Brand and type of Regulators should be exactly same as the Regulators used for the work specified in Schedule No -3) | 20 | NO | 400 ₹8,000 | 450 ₹9,000 | 350 ₹7,000 |
| 7.00 | Open pipe Point wiring with individual control For 16 A power sockets and 16 A DP switch for ACs, using Flexible copper cables 2.5 sqmm for control and neutral connection through pvc conduits not less than 20 mm using metal saddles with spacing not exceed 50 cm as per relevant drawings or instructions from FACT Engineer in Charge. The work shall include wiring along roof/beam/column/ceiling using clamps and drawing wires as required.
Preparation and fixing of modular switch boards, switches, cover plates, dummy plates, Etc drawing of 1.5 sq mm earth wires of flexible copper wire of green color for body earthing of metal clad items, connecting, testing and commissioning. For wire length greater than 10 m shall be considered as one and half point. All the materials for this Work shall be in the Scope of the contractor. If additional power sockets are required in same Switch Boards that shall be considered as half point.
APPROVED MAKE :
WIRE :- POLYCAB/ RR KABEL/ KEI/ FINOLEX OF FR TYPE
SWITCH, SOCKETS, ETC :- LEGRAND- MYRIUS //HONEYWELL-HORIZON/SCHNEIDER-UNICA PURE/L&T-ENTICE
PIPE SHALL BE OF MEDIUM ISI MARKED | 200 | NO | 1,690 ₹3.4 L | 1,600 ₹3.2 L | 1,450 ₹2.9 L |
| 8.00 | Supply of 16A Modular Switches as spares for the work specified in Schedule No -7
(Brand and type of switches should be exactly same as the switches used for the work specified in Schedule No -7) | 24 | NO | 175 ₹4,200 | 210 ₹5,040 | 110 ₹2,640 |
| 9.00 | Supply of 16A Modular Sockets as spares for The work specified in Schedule No -7
(Brand and type of sockets should be exactly same as the the sockets used for the work specified in Schedule No -7) | 36 | NO | 200 ₹7,200 | 180 ₹6,480 | 150 ₹5,400 |
| 10.00 | Supply of 16A Modular DP switches as spares for the work specified in Schedule No 7.
(Brand and type of DP switches should be exactly same as the switches sused for the work specified in Schdule no.-7) | 10 | NO | 330 ₹3,300 | 400 ₹4,000 | 300 ₹3,000 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
31 Oct 2025, 11:00 amClosed
SM(Mat)C
Corporate Materials, PD Administration Building, FACT - Udyogamandal, Kochi, Kerala
Re electrification of C type Flats, as per tender conditions.
2025_FACT_879497_1
03017/2025-2026/E32193
Open Tender
Electrical Works
730 days
FACT- Udyogamandal
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹25,000
Yes
18 Mar 2026
29 Sept 2025
1 Nov 2025
29 Sept 2025
31 Oct 2025
29 Sept 2025
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tenderdoc.pdf
Tender Documents • 8.32 MB
Compliancestatement.pdf
Tender Documents • 0.28 MB
BOQ_924458.xls
BOQ • 0.26 MB
Unpricedbid.pdf
Tender Documents • 0.11 MB
Download all tender documents and submit your bid