| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | ₹19.3 L Quoted ₹19.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.8 LRejected-Finance SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | ₹22.8 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected due to documents not found as per NIT |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected due to documents not found as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected due to documents not found as per NIT |
| Sl No | Description | Qty | Unit | Top Mind Industries Pvt Limited L1 | M/S BHAT ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for Taking down / Refixing and servicing of Split type (1.5/2.0 TR) / Window ACs (1.5 TR) capacity by cleaning coils with the use of shine solution, removing internal dust and cleaning of filters by using water pump jet and air blower, oiling & greasing wherever required and checking of all other parts and proper cooling complete all as specified and directed .
Note:-(i) All tools and machinery required deemed to be in quoted rates including servicing kit for indoor and outdoor unit with air compressor and servicing pump for removal of any foreign material from indoor/outdoor unit all as specified and directed by Engr-in-charge.
(ii) All minor parts reqd for satisactory performance of the AC must be replaced and shall deemed to be included in the above item rate. | 16 | EACH | 12,500 ₹2 L | 13,000 ₹2.1 L |
| 2.00 | Supply and fixing PCB suitable for Split type AC / Window type AC of 1.5/2.0 TR Capacity and model complete all as specified and directed. | 6 | Each | 1,000 ₹6,000 | 1,500 ₹9,000 |
| 3.00 | M&L for complete topping up the refrigirant gas (R-22) in split/ window type 1.5/2.0 TR & testing and commissioning complete all as specified and directed. | 6 | Each Job | 11,500 ₹69,000 | 10,000 ₹60,000 |
| 4.00 | Supply and fixed in replacement, PVC sheathed, 3 core 2.5 Sqmm copper conductor flexible cable of with thimbles of suitable size & shape complete all as specified and directed. | 200 | RM | 140 ₹28,000 | 180 ₹36,000 |
| 5.00 | S&F 3 pin 15 Amp plug top suitable for power load applications all as specified and directed by Engr-In-Charge. | 40 | EACH | 350 ₹14,000 | 450 ₹18,000 |
| 6.00 | S&F metal plug and socket DB, two pin and earth plug, 240 volts and including one 20 Amp MCB SP, C-Curve & complete all as specified and directed. | 5 | Each | 250 ₹1,250 | 450 ₹2,250 |
| 7.00 | M&L for Repair of body leakage of electric hamam of capacity 25 Ltr, steel body rectangular/cylindrical type with thermostates for auto cut and change of burnt heating element of capacity 1 KW complete all as specified and directed. | 30 | Each | 6,500 ₹1.9 L | 7,500 ₹2.3 L |
| 8.00 | S&F replacement of damaged aluminium cladding pipe off any size complete as required at site complete all as specified and directed. | 200 | RM | 100 ₹20,000 | 150 ₹30,000 |
| 9.00 | S&F replacement of damaged nitrile rubber insulation of 16mm thick and 1 mtr wide over pipes for CHS of any size as required at site complete all as specified and directed. | 200 | RM | 100 ₹20,000 | 150 ₹30,000 |
| 10.00 | S&F in replacement of reciprocating/rotary compressor including refilling of refrigirant R-134 A brazing and bring to be serviceable condition and testing suitable for 500 ltr Deep Freezer complete all as specified and directed. | 4 | Each | 8,500 ₹34,000 | 9,520 ₹38,080 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
8 Apr 2026, 9:00 amClosed
GE Khumbathang
GE Khumbathang
GE/KHU-101/2025-26 REPAIR/ REPLACEMENT OF VARIOUS HEATING AND COOLING DEVICES IN THE AOR OF AGE E/M OF GE KHUMBATHANG
2026_MES_756747_1
GE/KHU-101/2025-26
Open Tender
Support/Maintenance Service
180 days
GE Khumbathang
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE khumbathang
₹40,000
12 May 2026
18 Mar 2026
9 Apr 2026
18 Mar 2026
8 Apr 2026
1 Apr 2026
19 Mar 2026 - 31 Mar 2026
Supply and fixing PCB suitable for Split type AC / Window type AC of 1.5/2.0 TR Capacity and model complete all as specified and directed.
M&L for complete topping up the refrigirant gas (R-22) in split/ window type 1.5/2.0 TR & testing and commissioning complete all as specified and directed.
Supply and fixed in replacement, PVC sheathed, 3 core 2.5 Sqmm copper conductor flexible cable of with thimbles of suitable size & shape complete all as specified and directed.
S&F 3 pin 15 Amp plug top suitable for power load applications all as specified and directed by Engr-In-Charge.
S&F metal plug and socket DB, two pin and earth plug, 240 volts and including one 20 Amp MCB SP, C-Curve & complete all as specified and directed.
M&L for Repair of body leakage of electric hamam of capacity 25 Ltr, steel body rectangular/cylindrical type with thermostates for auto cut and change of burnt heating element of capacity 1 KW complete all as specified and directed.
S&F replacement of damaged aluminium cladding pipe off any size complete as required at site complete all as specified and directed.
S&F replacement of damaged nitrile rubber insulation of 16mm thick and 1 mtr wide over pipes for CHS of any size as required at site complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirant R-134 A brazing and bring to be serviceable condition and testing suitable for 500 ltr Deep Freezer complete all as specified and directed.
S&F in replacement of reciprocating /rotary compressor including refilling of refrigirent R-134 a, brazing and bring to be serviceable condition and testing suitable for 300 ltr Deep Freezer complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent, brazing and bring to be serviceable condition and testing suitable for 200 tr Deep Freezer complete all as specified and directed.
S&F in replacement of wall mounted fan coil unit of capacity 1.5/2 TR (4500 K Cal/Hrs 600 Cfm) complete all as specified and directed.
Supply, installation, testing and commissioning in Replacement of wall mounted type heating panels of rating 450 W and suitable size as per site requirement alogwith all connected accessories, complete all as specified and directed.
S&F in replacement of heating element AC 230 volt, triangle/round type of rating 1500 watt suitable for geyser/Hamam as per sample, complete all as specified and directed.
S&F in replacement of heating element AC 230 volt, triangle/round type of rating 2000 watt suitable for geyser/Hamam as per sample, complete all as specified and directed.
Supply and fixing in replacement of electric Hamam of capacity 45 Ltr , steel body rectangular/ cylindrical type with thermostates for auto cut and change of burnt heating element of capacity 2 KW complete all as specified and directed.
Supply and fixing in replacement of electric hamam of capacity 25 Ltr, steel body rectangular/ cylindrical type with thermostates for auto cut and change of burnt heating element of capacity 1 KW complete all as specified and directed.
Supply and fill the ethylene glycol in liquid form with 99% purity, meltig point (-13°C) , boiling point 198°C and density 1.11 g/cm³ complete all as specified and directed
Material and labour for repair of Water heater storage type, electric based,capacity 25 litres rate included in change of themostat,stainless steel tank,heating element complete all as specified and directed
S&F in repairs Gun metal Ball valve of 20 mm dia complete all as specified
S&F screwed type Bronze vertical check valve 15 mm bore by cutting and threading of GI pipe including necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.
S&F screwed type Bronze air release valve 15 mm bore by cutting and threading of GI pipeincluding necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.
S&F in repairs pressure release valve of size 15 mm (safety type) CP brass, ISI marked complete all as specified and directed.
Supply and replace blower motor/ Swing Motor of approved make including dismantling old one of the following:-
Indoor blower motor suitable for split ac/window AC 1.5/2 TR.
Swing motor with flapper for split ac/window AC 1.5/2 TR.
Motor for deep freezer 200 to 500 ltr.
M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 4 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 4 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed. Note : 1. Two run of main copper conductor 4 sqmm size , one run of 4 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length. 2. Proper colour coding shall be maintained as per IS code.
M&L for replacing the heating element of Heat pillar rod 2KW incl opening the outer cover rewiring the connectors compete all as specified and directed.
Supply and fixing of copper tube suitable for split ACs of capacity 1.5/2 TR of the following sizes including dismantling of old U/S copper tube and insulation of the new copper tube
Deduct Credit for Demolished/Dismantled material Rs (-)51,080.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
Tender101.pdf
Tender Documents • 1.54 MB
BOQ_847668.xls
BOQ • 1.78 MB
Download all tender documents and submit your bid