Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC AIR FORCE ROAD NEAR BRIDGE OPP KHETIWADI RAJIV NAGAR JAMNAGAR 361002 | JAMNAGAR | JAMNAGAR | GUJARAT | 361002 | L1 | Accepted-AOC AOC | |
| 2 | L2₹50.0 L+₹1.1 L (2.14%)Rejected-Finance AIR FORCE ROAD NEAR BRIDEES CORP KHELTIWADI RATIY N 9306 JAMNAGAR GUJARAT 361 006 | JAMNAGAR | JAMNAGAR | GUJARAT | 361006 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹50.1 L+₹1.2 L (2.36%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹50.2 L+₹1.2 L (2.48%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹50.5 L+₹1.6 L (3.23%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹48.5 L
EMD Value
₹96,900
Closing Date
6 Oct 2021, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
ADDN, ALTERATION TO BLDG NO P-121A, AUGMENTATION OF DRAINAGE SYSTEM IN MD ACCN AREA AND DEMOLITION OF MR 310 STRUCTURE ON ROOF TOP OF BLDG NO. P-162 IN THE AREA OF VALSURA UNDER GE (I) NAVY JAMNAGAR
2021_MES_466258_2
8541
Open Tender
Civil Works
Item Rate
180 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹96,900
Yes
1 Jan 2022
24 Sept 2021
8 Oct 2021
24 Sept 2021
6 Oct 2021
24 Sept 2021
Amount
PART I: DRAINAGE SYSTEM & BLDG WORK Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MOD land complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MOD land complete all as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for and removal of entire debris as ordered outside MD land complete all as directed.
Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MD land complete all as directed.
Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 Sqm each with shutters (without taking off shutters from frame) and stacking at site where directed.
Dismantling of fencing wire mesh any type complete all as specified.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of drain, man hole, stay etc. not exe. 10 Sq. m on plan and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation of drain, man hole, etc. not exceeding 10 Sq. m on plan and getting out in soft / disintegrated rock complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and depth exceeding 1.5 m upto 3.0 m or part thereof for foundation of drain, man hole, etc. not exceeding 10 Sq. m on plan and getting out in hard/ dense soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
M & L for PCC 1:4:8, type D2 (using 40 mm crushed stone aggregate) as in foundation filling mass concrete complete all as specified and directed
M&L for PCC 1:3:6, type C2 (using 40 mm crushed stone aggregate) as in pipe surrounding, haunching, bed foundation filling mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B2 (using 40 mm cushed stone aggregate) as in surface channel, drains and benching in manholes and finishing of exposed surfaces of concrere complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregate as in cast in situ in cills and other similar bands, plinth courses, parapets, coping, bed plates, water throughts and the like including necessary form work, weathering slightly rounded, chamfered angles and throating complete all as specified and directed.
M&L for Reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings , balconies and shelves complete all as specified and directed.
M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks as per IS-2185, exceeding 10 cm in width and setting in CM 1:6 complete all as specified and directed.
M & L for plain cement concrete 1:3:6 type C1 (using 20 mm graded granite stone aggregate) as in cast in situ in cills and other similar bands, plinth courses, coping, bed plates including necessary form work , weathering slightly rounded, chamfered angles and throating complete all as specified and directed.
M&L for Precast Reinforced cement concrete 1:2:4, type B1 (using 20 mm crushed stone aggregate) as in landing, cover slab (for manholes etc.), water throughs and similar articacles with plain faces, set and jointed in cement mortar 1:4 complete all as directed.
Supply only Integral Water Proofing Compound (ISI Marked) complete. Make: CICO, Acco Proof, Impermo, Aqua flex as approved.
M & L for Extra for forming fair finishing drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered stopped ends etc complete all as specified and directed.
Add or deduct for each 25 mm girth or part thereof or under 35 cm -ditto -
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished of concrete flat complete all as directed.
M&L framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as directed.
S&F rolled MS in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 290 Gde E-165.
S & F Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates stell conforming to Fe-410W (Gde-E-250) quality 'A' complete all as specified and as directed.
S & F Rolled mild steel Fe 410 -W (Gde E250) quality -A as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
S & F rolled mild steel Rolled sections Fe 410 W (Gde E 250) quality -A channel , angle or tee sections as in framing for steel racks , for cladding, glazing and the like fixed with angle cleats and complete all as specified and as directed.
S&F 10 mm dia and over TMT bars cut to length bent to shape required cranking including bending, hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for 6 to 8mm dia TMT bars cut to length bent to shape required cranking including bending, hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L mild steel work such as in angles, bars, flat iron etc for holdfast / wind tie and similar work conforming to Fe.290.Gde-E-165
M&L MS round bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending, painted with two coat of aluminium paint over a coat of primer and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed.
Supply only MS galvanized chain link fencing (120 to 140 gms) 4mm dia and 75mm spacing and weighing not less than 2.75 kg/sqm diagonally pinned including line wire rails, straining bolts and provision of binding wire complete all as specified and as directed. Make: M/s Sachin, TATA or any approved make as approved..
Fixing only diagonally pinned fencing wire including line wire, any mesh size and type of standards, rails, straining bolts etc. including provision of binding wire complete all as directed.
S&F factory made Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm but not exceeding 10 cm long (Diameter of neck 11 to 15 mm) complete all as directed.
S&F pre-painted galvalume (zincalume) aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/cladding to walls fixed with self tapping screws as specified.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as directed.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window shutter to glazed and gauze, fixed/ sliding type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws etc. complete all as directed. Note: Glass shall be measured and paid seperately.
S&F aluminium alloy wire mesh, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples.
M&L 100 mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
M&L for 25mm avg thick plain cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in padding of roof for levelling complete all as directed.
M&L non-skid jointless coloured ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified.
M&L glazed ceramic designer tiles any shade or pattern as approved of size 600x300x7 mm thick, on verticals surfaces, set and jointed in neat cement slurry including 10 mm thick back coat in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all directed. (Note for item Nos 42 & 43 : i) Quoted rate is deemed to be inclusive of cement screed. ii) Shade / pattern / Colour of tiles shall be got appproved before procurement).
M&L 16 to 18 mm thick granite slab (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window- cills ,skirting / dado cooking platforms, wash basin counter and like set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over cement screed plaster 10 mm thic in CM 1:3 complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as directed.
Material and labour for removal of existing WPT course or any other kind of treatment i.e. plaster/ concrete/ brick cova etc. surface over roof slab and cleaning of surface with wire brushes and water removing of unsolvent materials and depositing of the same as directed outside MoD land and provide 15 mm thick screed bed/ bedding layer in CM 1:3 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply oil bound bituminous primer @ 0.30 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure as directed and finally finished the top surface with two coats of thermal resistant paint complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive of taking down & removal of debris , 15 mm thick 1:3 screed & complete APP treatment. (ii) WPC will be paid seperately (iii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, desing & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength, thickness & size/ shape, made by table vibratory method using PU mould, required colour and pattern overe and including 50mm thick compacted bed of coarse sand, compacting and proper embeding/ laying of interlocking paver blocks into the sand bedding layer through vibrotory compaction by using plate vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. (Note: Quoted rate is deemed to be inclusive of 50 mm thick compacted sand cushoning).
M&L M-35 grade, 60 mm thick machine pressed, PVC moulded precast cement concrete interlocking paver blocks any shape and size with grey cement and pigment confirming to IS: 15658-2006, laid over and including 50 mm thick compacted sand cushion complete complete all as specified. (Note: Quoted rate is deemed to be inclusive of 50 mm thick compacted sand cushoning).
M&L for machine cut kota stone slab of minimum size 550 x 550mm, 20-25 mm thick, as in floor laid over and including 15 mm thick screed bedding in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & mirror, polishing complete all as directed.
M&L for rendering 15 mm thick in CM 1:6 on brick work/ stone work or concrete surface work finished even and smooth without using extra cement complete all as specified.
All as per item No 50 here-in-above but 10mm thick in CM 1:3 on ceiling, chajja, roof projection etc.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified.
Three coats of white wash on newly plastered surface of ceiling after necessary preparation of surface complete all as directed.
M&L for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or unplastered surfaces) and applying three coat of white wash of white wash complete all as directed.
M&L for preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 3 mm thick white cement based wall care putty complete all as specified.
M&L for complete removal of existing treatment and preparing old plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resist primer over a coat of 3 mm thick white cement based wall care putty complete all as specified.
M&L for preparing newly plastered or unplastered surfaces of exterior walls and applying two coats of antifungal exterior emulsion weather proof paint (Apex) oover a coat of exterior primer complete all as specified.
M&L for complete removal of existing treatment and preparing old plastered or unplastered surfaces of exterior walls and applying two coats of antifungal exterior emulsion weather proof paint (Apex) over a coat of exterior primer complete all as specified.
S&F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as directed.
M&L for two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surface complete all as directed.
M&L two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint including necessary preparation of new steel surface complete all as directed.
M&L for Reinforced concrete pipe 300mm bore Class NP2 (ISI Marked) alongwith collar laid to slope in trenches over PCC bed & jointed in cement mortar 1:3 and tested on completion complete all as specified and directed.
All as per item No. 62 here-in-above but 450mm bore -do-
E&M Items: Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed.
M&L for point wiring with 1100V grade with 1.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through in existing PVC concealed 20 mm dia conduit and conduit accessories with concealed MS/ PVC Box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 sqmm as earth wire connected to common earth dolly as specified for one light point controlled by one switch complete all as directed. Note : (1) Rate include cost of cutting wall / floor / ceiling and making chasses and MS box in concealed for cutting and sinking for boxes and making good to walls, no extra payment will be made for the same. (2) Switch and socket shall be measured and paid separately.
All as per item No. 65 here-in-above, but for 6 Amp (2/3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 65 here-in-above but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 65 here-in-above but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 65 here-in-above but size of cable 4 Sq.mm for 16 Amp (3 pin), Metal socket in independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F in repairs switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs switch modular type single pole one way 16 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 11 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet 3 Pin 6 Amp modular type all accessories complete all as directed. Make: Legrand Cat No. 6755 52 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet multipurpose 2/3 Pin for 6 / 16 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 55 or equivalent in Philips / Crabtree / ABB / Havells
S&F for Single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one single pole MCB 20 Amps complete all as directed.
S&F in repairs ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
Taking down old light fittings of any description and S&F new LED 4' Glaze LED Batten high quality design aluminium extruded with decorative end caps light fitting and fixed as per manufacturer's instruction complete all as specified and directed. Make: Jaguar Cat No. LGLZ01X024XC 24W or equivelant in Wipro/ Havells/ Bajaj
S&F 1400 mm sweep, ceiling fan with all accessories 230 V, SP with provision of 3 core cable from ceiling rose to fan complete including making arrangement for Fan hook of standard type as per SSR specification including cutting RCC slabs to the required depth upto existing MS bars tie up with new one and making good the disturbed surfaces, including taking down old fan complete all as specified and as directed. Make: Bajaj Model No. Kessle 50 ISI 1400 mm White CF or equivalent in Havells/Khaitan/ Usha/ Orient) Note: Old ceiling fan shall be deposited in the AGE E/M store yard.
S&F Step type electronic fan regulator modular type 120W, 2 Module
S&F GI tubing medium grade 15mm bore use for hanging ceiling fan for suitable size white colour with all necessary fitting complete all as directed.
S&F 450 mm sweep 900 RPM exhaust fan metal body, AC, single phase, 230/240 V with lower shutter venti Air including taking down old exhaust fan complete all as directed. Make: Bajaj Supreme Dlx 450mm 900 rpm 1ph Ind Ex fan or equivalent in USHA/ Khaitan/ Crompton Greaves Note: Old exhaust fan shall be deposited in the AGE E/M store yard.
S&F box fabricate from 2mm thick CRCA sheet doule door type of size suitable for fixing DB's, three phase, 2 Nos. complete with cable alley for incomming & outgoing cable, compartment for powder coated painting and fixing arrangement etc including LT danger notice plate complete. Note: MCB's and kWH meter shall be measured and paid separatly.
S&F MCCB DB's VTPN (Vertical DB) type double door in wall/ nitch when MCCB's to be used four pole and neutral, 8 way, 415 Volt with rated busbar, suitable for flush mounting and surface mounting with 160 Amps copper busbar for each pahse and 2 neutral bar, 2 Earth bar and cable ties for cble management, fully insulated busbar and shrouded Neutral bar, improved pan assembly for ease of intallation, Prefitted masking sheet, Reversible door for IP 43 & IP 54 DBs with provision for DPX3 160 MCCB as incomer and TPN/ SPN/ DP/ SP outgoing IP 54 Protection Make: Legrand Cat No. 5077 52 (No. of modules DPX3 160+24) or equivalent in Indo Asian, Standard and incuding MCCB DPX3 160 Amp 415 V with adjustable thermal and magnetic setting of breaking capacity 36 kA complete all as specified and as directed by Engineer-in-Charge. Make: 4200 87 (MCCB 160 Amps) or equivalent in Indo Asian, Standard.
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB TPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No 5077 25 or equivalent of Havells / L&T / ABB
S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply. Make: Legrand Cat No. 4086 83 or equivalent of Havells / L&T / ABB
S&F in repairs MCB SPN 32 Amp 240/415 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 4086 14 to 17 or equivalent of Havells/ L&T/ ABB
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 87 to 4085 95/ Havells/ L&T/ ABB
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 6 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 6 Sq.mm one run complete. Note: 2 run of 6 Sq.mm cable one run 6 Sq.mm earth wire with casing capping considered as one unit.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 4 Sq.mm PVC insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 4 Sq.mm one run complete. Note: 2 run of 4 Sq.mm cable one run 4 Sq.mm earth wire with casing capping considered as one unit.
Taking up or down exingting cable and Supply and lay cable in trenches or fixing on wall or pole XLPE cable insulated screened PVC beded GI steel strip or wire armoured electric power cable (heavy duty) with standard aluminium conductor 1100 volt grade cross sectional area 35 Sqmm 3.5 core making necessary connection & testing on completion all as directed.
S&F 40 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, fixed to wall, ceilings or in floors etc. complete as directed.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion.
PART II: DEMOLITION OF PART BLDG & RENOVATION Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as directed.
Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4 sqm each with shutters (without taking off shutters from frame) and stacking at site where directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MOD land complete all as directed.
Dismantling structural steel work including doors, gates but excluding framed trusses etc.and stacking at site complete all as directed.
Seperating and scrapping and cleaning of reinforcement from demolished RCC concrete of item No 24 here-in-above & stacking at site complete all as directed.(Note : Demolition of concrete measure seperately)
Removing entire demolished debris out side MD land complete all as directed. (Note : Quoted rate is deemed to be inclusive for loading, unloading and removing &depositing debris out side MD land).
M&L for 25 mm thick plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate on RCC roof complete all as specified and as directed.
Supply only Integral Water Proofing Compound (ISI Marked) of Make: CICO, Acco Proof, Impermo, Aqua flex as approved.
Material and labour for removal of existing WPT course or any other kind of treatment surface over roof slab including plastering and cleaning of surface with wire brushes and water removing of unsolvent materials and depositing of the same as directed outside of MoD land and provide 15 mm thick screed bed/ bedding layer in CM 1:3 mixed with Water Proofing Compound (WPC) as per manufacturer instructions, including finishing the surface fair and even on RCC roof/ parapet once bedding layer of concrete is completely dried and apply oil bound bituminous primer @ 0.30 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyster matt weighing not less than 160 gms/Sqm including minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure as directed and finally finished the top surface with two coats of thermal resistant paint complete all as specified and as directed. Note: (i) The quoted rate is deemed to be inclusive of taking down & removal of debris , 15 mm thick 1:3 screed & complete APP treatment. (ii) WPC will be paid seperately (iii) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT (iv) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
M&L for Chequered cement concrete PVC moulded coloured tiles 25cm x 25cm x 25 mm thick laid over and including 15 mm thick screed bed in cement mortar 1:6 mixed with proper sealant mixed with CM 1:3 over APP membrane complete all directed.(Note: Quoted rate is deemed to be inclusive of cement screed).
M&L for steel scaffolding fo demolition of building (Top portion only) upto 9mtr height and provision of PVC net all around to prevent droping of demolished material complete all as specified and directed.(Note for Part II :The demolition /dismantling as described in varios items of Part II shall be carried out above tripple storey Bldg of approx 9mts in height , as such necessary following shall be adhered to as under : (i) Scafloding as per relevant safety IS norms shall be followed & the same to be got approved be Engineer-in-charge before commencement of demolition / dismantling work. (ii) Trades man / labourers involed in work of above height should be carried out in presence of any saftey qualified supervisior to avoid any sort of accident/ incident due to negligence of trades man or lack of experience in working in above height as such all tradesman involved in the task should pocesses valid insurance & the same to be submitted to Engineer-in-charge for verification & record. (iii) All necessary saftey precations equipments as per IS such as hand gloves , safety belt , head helment etc shall be arranged by the contractor (iv) During demolition / dismantling in existing structre any adjacant Bldg / structure is damaged for whatso ever reasons due to negligence of working people the same to be made good as per its orignal specifiaction to entire satifaction of Engineer-in-charge without any extra cost to Govt. (v) The quoted rate aganist various items in BOQ is deemed to be inclusive of the same & no extra shall be enertained. Contractor must visit the site of demolition/ dismantling prior quoting his bid to have a better assessement.
SohanandCompany
M/s.Bhavin Electricals
Jyoti Refrigeration
Raj brothers
aarti construction
JAMNAGAR ELECTRIC AND MACHINERY CO
rahil enterprise
M/s Balaji Enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .