| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.8 L+₹49,950 (4.84%)Rejected-Finance | L2 | Rejected-Finance Reject due to L2 | |
| 3 | L3₹11.2 L+₹83,801 (8.11%)Rejected-Finance | L3 | Rejected-Finance Reject due to L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED DUE TO NOT CAPABLE OF HANDLING MORE LOAD AS PER WLR OF QE SEP 2022 OF HQ CESC PUNE |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
11 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) NO 2 JODHPUR
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (ARMY) NO 2, MULTAN LINES, JODHPUR - 342010
REPAIR, MAINTENANCE, SERVICING OF STANDBY DIESEL ENGINE DRIVEN GENERATING SETS AND ITEMS CONNECTED MISC ITEMS LOCATED AT OTHER THAN SECTOR A, SECTOR B AND SECTOR C UNDER GE (ARMY) NO.2 AT ARMY AREA JODHPUR
2023_MES_585740_1
8847/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (ARMY) NO 2 JODHPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (ARMY) NO 2
₹24,000
Yes
24 Jun 2023
14 Mar 2023
13 Apr 2023
14 Mar 2023
11 Apr 2023
28 Mar 2023
14 Mar 2023 - 25 Mar 2023
Amount
M&L for routine servicing of DG set of capaciities 20 to 30 KVA including alternator, electric panel board connection to DG set as per OEM check list & maintaining proper records of the same and submit to Engineer-in-charge after every maintainance. Repair and labour cost of item is included in quoted rates and replacement of new item will be measured and paid seperatly under relevant items for DG set.
All as per ser Item No 1 above but for DG Set of 30 to 63 KVA capacities
All as per ser Item No 1 above but for DG Set of 63 to 125 KVA capacities
All as per ser Item No 1 above but for DG Set of 125 to 200 KVA capacities
All as per ser Item No 1 above but for DG Set of 200 to 400 KVA capacities
All as per ser Item No 1 above but for DG Set of 400 to 625 KVA capacities Servicing of the DG set should be followed as per the instructions given under: (i) Checking and rectifyng of Battery charging system , level up Electrolite and specific gravity. (ii) Checking and rectifyng of Leakage in fuel lines & connections of fuel pump. (iii) Leakage of Lub. Oil and cooling system, hose pipe & connection, belts tension, fan hub drive pully and water pump and cleaning of water separation and cooling system. (iv) condensate trap. Repair of leakage/ maintenance of water cooling system. Cleaning of radiator by draining out of Coolent, checking of all hose pipes, nut & bolts and tightening properly including checking of leakages all as directed by Engr – in – Charge. (v) Reset the complete switches in automatic lighting connection. (vi) Cleaning of complete D G Set, check and tightening of all nut &bolts including replacement of U/S parts , oiling/ greasing of all movable parts and unusual vibration. (vii) Leakage in exhaust system and exhaust restriction, drain out condensate trap. Repair of leakage/ maintenance of water cooling system. checking of all hose pipes, nut & bolts and tightening properly including checking of leakages all as directed by Engr – in – Charge. (viii) Check all electrical connection of alternator and control wiring (ix) Check all earthing connection of DG Set, repair the same if required (x) Drain out old used engine oil from the DG Set cleaning the sump Properly including opening of “B” check kit.Filling of Engine Oil 20W40 or as recommended by the manufacturer, Qty of Engine Oil is specified separtly. (xi) Opening of all filters such as diesel filters, oil filters, Air filter and other required items. proper cleaing of the items and reinstalling or replace the same if required. ( Xii) Testing the D G Sets after completion of work. (Xiii) Contractor shall employ skilled labour (FGM) for the above repairs. All the complaints arised should be attended and solved on the same day within one hour by one company engineer/ technician for over all repairs. Note:- Replacement of required spare parts will be measured and paid separately.
M&L for the Fuel flow filter with ring including screen filter for D G Sets of capacity 500 KVA
All as per Ser Item No 2 above but for Oil filter.
M&L for Fuel flow filter with ring including screen filter of D G Sets of capacity 200/180/160 KVA :
All as per Ser Item No 3 above but for Oil filter.
M & L for Fuel flow filter with ring including screen filter of D G Sets of capacity 125 KVA,110 KVA & 100 KVA.
All as per Ser Item No 4 above but for Oil filter.
M & L for Fuel flow filter with ring including screen filter of D G Sets of capacity 62.5,63,50 & 40 KVA
All as per Ser Item No 5 above but for Oil filter.
M & L for Fuel flow filter with ring including screen filter of D G Set of capacity 250 KVA.
All as per Ser Item No 6 above but for Oil filter.
M & L for Fuel flow filter with ring of D G Sets 20 KVA.
All as per Ser Item No 7 above but for Oil filter.
Supply and filling of superior grade engine oil 20W40 for DG et topping .Make:HPCL/BPCL/IOCL
S&F (in repairs) solenoid coil suitable for DG set of capacity 30 to 160 KVA self starter Make : L&T, BCH, AE, GE, Standard
Supply & filling only coolent "K' Cool Super plus 50-50 Premix for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation, all as specified and directed.
Supply and topup / replace distilled water for battery or radiator of engine used with coolent "K' Cool Super plus 50-50 Premix all as specified and directed.
Dismantling unserviceable battery charging dynamo from DG set of rating 1 x 12 / 2 x 12 Volts complete repairs and servicing including replacement of bushes, bearings, Carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required all as directed and fixing on engine testing/commissioning complete for DG set having any capacity. Note : Replacement of rotor armeture coil if reqd shall be measured and paid seperately.
Dismantling self starter 12V/24 V of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt aremeture, rewinding of Fd coils, replace of pinion gears etc, completer servicing and refixing after repair, testing/commissioning complete for DG Set any capacity
S&F (in repairs) solenoid coil suitable for DG set of capacity200 to 625 KVA self starter Make : L&T, BCH, AE, GE, Standard
S&F (in repairs) armeture coil complete with shaft suitable for DG set self starter MAkE : L&T, BCH, AE, GE, Standard
S&F (in repairs) pinion gear suitable for DG set self starter. MAkE : L&T, BCH, AE, GE, Standard
Dismantling old unserviceable battery charging dynamo of rating 12/24 volts and supply and fixing new battery charging dynomo same as per existing model suitable for fixing on DG set, 1500 rpm including testing after complete installation all as directed and specified. Make-LUCAS TVS or as exiting make to suit DG set all as specified and directed by Engineer-in Charge.
Dismantling old unserviceable Self starter of Disel engine and supply and fixing new self starter of working voltage 12 volt/24 Volt DC and same as per existing model suitable for fixing on engine set including testing after complete installation all as directed and specified.
S&F and replace 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for any type of DG Sets.20 KVA to 200 KVA
S&F in repairs EC2 AMF logic relays, suitable for DG set of any capacity AMF panel board of make and model as per existing sample all as directed by Engineer-in-Charge.
Supply & fix in repairs AVR Chipset Suitable for DG set alternator of any capacity make and model all asper exiting sample
S&F in repairs Indicating lamps, 230 volt, AC, LED type suitable for DG set AMF/LT panel board.
S&F in repairs overload relay 10 Amp to 80 Amp suitable for AMF/LT panel board of make and model as per existing sample all as directed by Engineer-in-Charge.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
S&F in repairs ON/OFF switch, single pole suitable for DG set AMF panel boards. Make : L&T/Salzer
Supply& fix in repairs SMPS automatic battery charger 12/24volt suitable for DG set AMF panel board.
Supply & fix in repairsVMR protection device 3 phase, 415V suitable for DG set AMF panel board.
S&F in repairs multifunction AMF panel control meter of make and model as per existing make provided in AMF panel boards all as directed by Engineer-in-Charge.
S&F and replace 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for any type of DG Sets.200 KVA to 625 KVA
S&F in repairs Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 500 KVA.
S&F in repairs Air filter element suitable for existing type of modele DG set Engine of capacity 200/250 KVA.
S&F in repairs Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 160 KVA.
S&F in repairs Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 125 KVA
S&F in repairs Air filter element inner and outer suitable for existing type of modele DG set Engine of make Kirloskar and capacity 100 KVA.
S&F in repairs Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 62.5 KVA.
S&F in repairs Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 50 KVA.
S&F in repairs Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 20 to 40 KVA.
M&L for draining out coolent water from radiator, dismantling radiator, repair of radiator for leakage if any, cleaning the radiator set with dilute HCL, kerosin, fresh water and refixing the same with new rubber hose with clamps filling with coolent with distilled water and checking for its proper function on DG set all as directed and specified. Note : Coolent and distilled water shall be measured and paid separately under relavant items.
Supply and fix in replacement battery lead length not less than 1.25 Mtr long and not more than 2.5 mtr as per connection requiremnt of each DG set, PVC insulated multistranded copper conductor 70 sqmm single core, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on DG Sets of any capacity .
Labour only for attending breakdowns of DG sets/AMF panels through skilled technician from reputed service centre of DG sets with necessary tool kits, checking Engine and alternator for defects, carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replace of external spare to repair/rectify the defects and testing DG set for its smooth functioning on full load all as specified and directed by Engr-in-Charge. Note : 1. Necessary spares required to rectify the defects shall be measured and paid separately under relavant items. 2. The complaint shall be attended and rectifed within 24 hrs form time of reporting by Engr-in-Charge or his auth representative. 3. Any Major defects shall be reported on Priority to Engr-in-charge to avoid undue delay in fuctioning of installation.
Replacement of control card of AMF panel with defective controller model and type as per existing to DG set of any capacity
Dismantling of ACB of various capacity from the panel and opening the same and servicing the ACB by using gear oil etc and refixing of the ACB including replacemnet of ACB coil all as per directions of engineer-in-charge.
Dismantling of mannual fuel pump of DG set any capacity and taking the same to reputed workshop and reparing the same for any defects and refixing the same onto dgset all as directed by engineer-in-charge
S & F Replacement of electronics governer of the dgset of any capacity existing type and size and model all as specified and direction of engineer-in-charge
S&F in replacement of moving contact & fixing contact set of contactor capacity 100 to 200 Amp
S&F in replacement of moving contact & fixing contact set of contactor capacity 20 to 50 Amp
S&F in replacement of moving contact & fixing contact set of contactor capacity 50 to 100 Amp
Replacement of terminal block of suitable size with four terminal including nuts ,bolts ,washers with all acessries matarial.
S & F in replacement of power contactor 4P of MCX 22 make and model as per existing in the DG set all as specified and directed.
S & F in replacement of power contactor 4P MCX 32 make and model as per existing in the DG set all as specifided and directed.
S & F in replacement of power contactor 4P MCX 34 make and model as per existing in the DG set all as specified and directed.
S & F in replacement of power contactor 4P MCX 41/MCX 44 make and model as per existing in the DG set all as specified and directed.
S&F in replacement flexible fuel pipe complete set with banjo bolt and washer etc length of fuel pipe shall be as per requirement at site and as per existing sample.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 20 KVA to 62.5 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set as directed by Engr-in-charge.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 100 KVA to 200 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set as directed by Engr-in-charge.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity 250 to 650 KVA and above all as per existing sample with GI clamps and Nut bolt, washers for DG set as directed by Engr-in-charge.
M&L for laying, jointing, testing cable XLPE insulated, armored and PVC sheathed LT 1100 volts grade and aluminum conductor confirming to IS 1554 laid in trenches/through pipe/floor/fixed wall etc complete all as specified and directed for size of cables 50 Sqmm 3.5 core stranded conductor
All as per item No 60 here-in-above but size of cable 95 Sqmm 3.5 core stranded conductor.
All as per item No 60 here-in-above but size of cable 120 Sqmm 3.5 core stranded conductor.
All as per item No 60 here-in-above but size of cable 150 Sqmm 3.5 core stranded conductor.
M&L for replace of MCCB four pole, 415 Volts, 250 Amps capacity 36 KA rating with thermal relay and as per model & make provided in existing panel board including taking out old unserviceable MCCB Make - L&T, ABB,C&S,Havells,Legrand.
M&L for replace of MCCB four pole, 415 volt 125 Amps capacity 25 KA rating with thermal relay and as per model & make provided in existing panel board including taking out old unserviceable MCCB Make - L&T, ABB,C&S,Havells,Legrand.
M&L for replace of MCCB four pole, 415 volt 100 Amps capacity 25 KA rating with thermal relay and as per model & make provided in existing panel board including taking out old unserviceable MCCB Make - L&T, ABB,C&S,Havells,Legrand..
M&L for replace of ON LOAD change over switch, 4 pole, 415 Volts,& repair assembly according to existing panel 100 Amps capacity and as per model & make provided in existing panel board including taking out old unserviceable changeover
M&L for replace of ON LOAD change over switch, 4 pole, 415 Volts,& repair assembly according to existing panel 250/315 Amps capacity and as per model & make provided in existing panel board including taking out old unserviceable changeover
M&L for replace of ON LOAD change over switch, 4 pole, 415 Volts, 200 Amps capacity and as per model & make provided in existing panel board including taking out old unserviceable changeover
M&L for replace of ON LOAD change over switch, 4 pole, 415 Volts, 400 Amps capacity and as per model & make provided in existing panel board including taking out old unserviceable changeover
Supply and fix HRC Fuse link and with basse plate 800 Amp as per existing make and model of panel board including taking out unserviceable HRC Fuse in panel with Fuse puller as as directed by Engineer-in-Charge.
Supply and fix HRC Fuse link and with basse plate 400 Amp as per existing make and model of panel board including taking out unserviceable HRC Fuse in panel with Fuse puller as as directed by Engineer-in-Charge.
Supply and fix HRC Fuse link and with basse plate 315 Amp as per existing make and model of panel board including taking out unserviceable HRC Fuse in panel with Fuse puller as as directed by Engineer-in-Charge.
Supply and fix HRC Fuse link and with basse plate 200 Amp as per existing make and model of panel board including taking out unserviceable HRC Fuse in panel with Fuse puller as as directed by Engineer-in-Charge.
Supply and fix HRC Fuse link and with basse plate 100 Amp as per existing make and model of panel board including taking out unserviceable HRC Fuse in panel with Fuse puller as as directed by Engineer-in-Charge.
M&L for servicing of Mud pumps of capacity 5/15 HP by changing engine oil, filters, and cleaning as per OEM instructions all as per directions of Engineer-in-Charge.
Shri Ram Traders Co
OM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .