Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Accepted |
Tender Value
₹14.0 L
EMD Value
₹27,940
Closing Date
17 Dec 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CCE
CCRND SOUTH P B NO 1569 AKBAR ROAD SECUNDERABAD
PROVISION OF HARDSTAND AND INTER CONNECTED ELECTRICAL GROUNDING PITS NEAR MI-6 AT ATR, CHITRADURGA FOR MTRDC
2021_DRDO_659830_1
83585/CIV/MTRDC/CON
Limited
Civil Works
Item Rate
120 days
CHITRADURGA
AS PER NIT
2 documents required · 2 mandatory
₹500
Yes
CHIEF CONSTRUCTION ENGINEER RND SOUTH SECUNDERABAD
₹27,940
Yes
6 Jan 2022
26 Nov 2021
20 Dec 2021
26 Nov 2021
17 Dec 2021
10 Dec 2021
27 Nov 2021 - 9 Dec 2021
90 days
Amount
Earth work in Excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Ordinary Rock
Hard rock (blasting prohibited)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand(Manufactured) : 8 graded stone aggregate 40 mm nominal size)
RCC 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for Reinforced Cement Concrete Work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
All works upto plinth level
All works above plinth level upto floor V level.
Reinforcement steel TMT bars FE 500 D
Centering and shuttering including strutting, propping etc. and removal of form for all heights:-
Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Suspended floors, roofs, landings, balconies and access Suspended floors, roofs, landings, balconies and access platform
6 mm Thick Plastering in cement mortar 1:3 (1 cement: 3 fine sand) at all levels and locations for all concrete surfaces of columns, beams,walls, and slabs finished smooth and even etc., complete
12mm Thick Plastering in cement mortar 1:6 (1 cement: 6 fine sand) at all levels and locations furnished smooth and even etc., complete
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
Pointing on stone work with cement mortar 1:3(cement:3 fine sand):Flush/ruled pointing
Earth work in excavation by mechanical means (hydrauliceexcavator)/manual means over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m as directed by engineer-in-charge
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas exceeding 30 cm in depth 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m as directed by engineer-in-charge
a) Ordinary rock
b) Hard rock(blasting prohibited)
supplying of approved earth and banking excavated earth in layers not exceeding 20 cm in depth breaking clods,watering,rolling each layers in 1/2 tonne roller, or wooden or steel rameers, and rolling every 3rd and top-most layer with power roller of min 8 tonnes and dressing up, in embankments for roads, flood banks marginal banks,and guide banks etc., lead upto 50m and lift upto 1.5m in all kinds of soil
Providing, laying,spreading and compacting graded stone aggregate(size range 53mm to 0.075mm) to wet mix madacam(WMM) specification including premixing the material with mechanical paverfinisher in sub-base/base course on well prepared surfacewater at OMC in for all leads and lifts laying in uniform layers with mechanical pavefinisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of engineer-in-charge
Providing and laying C.C pavment of Mix M-25 with ready mixed concrete from batching plant.The ready mixed concrete shall be laid and finished with screed board vibrator , finally finished by floating .brooming it wire brush etc. Compleate as per specificatioin and directions of Engineer-in-charge.
Structral steel work in single sectioin ,fixed with or without connecting plate ,including cutting ,hoisting ,fixing in position and applying a priming coat of approved steel primer in all complete .
Providing and laying foundatin Bolts as per specifications and directions of Engineer-in-charge.
Dry stone pitching 22.5 cm thick including supply of stone and preparing surface complete.
Supplying,erection testing and commisioning of out door TP sheet steel enclosure on surface/recess along with 3 pole 100 A 16 KA MCCB with thermomagnetic release and terminal spreaders complete with connections.
Supply, laying, testing and commissioning of 1.1 KV grade XLPE insulated armoured aluminium conductor underground cable of following sizes, in built up cable trench/already inid RCC hume pipe or on cable tray with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750 mm below ground level including excavation in any type of soil including SDR and Hard rock and refilling of earth after cable are laid, providing protection with sand and bricks at top. The cable shall be confirm to IS 7098/Part-1
a) 3.5 Core 50 Sqmm AL Cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV crede as required.
a) 3 1/2 X 50 sq. mm (35mm)
Providing and fixing of maintenance free earthening which consists of 65 mm Dia, 3 Mtr length (as per equipment supplier) electrode capsule, filled with enhancing compound, sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 Mtrs. Bentonite compound upto a depth of 2.0 Mtrs around the electrode capsule and also with brick chamber and cast iron cover etc., complete.
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the wall with necessary interconnections with earth station and equipments.
a) 50 x 6 mm G.I. Strip
b) 25 x 6 mm Copper Strip
c) 25 x 6 mm G.I. Strip
Supply and laying of following size earth strips including excavation and refilling of earth when laid in ground and with all fixing accessories when laid on the wall with necessary interconnections with earth station and equipments. Including welding of GI strip with reenforment of hardstanding
a) 50x6 mm GI. Strip
Credit for hardrock
Note: Certain Scheduled items the Earth work PCC (1:2:4, 1:4:8), RCC, Reinforcment steel, RR mansory, pointing etc., repeated in various sub heads, Bidder is requuested to quote the same rate for similar items. However, if there is any veriation in rates quoted by Bidder in similar items under differenct sub heads, the lowest rate shall be considered
Wherever writen for sand should be read as manufacutred sand.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .