Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance B 248 BASEMENT BLOCK B CHITTARANJAN PARK NEW DELHI 110019 11 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 101 C 1ST FLOOR PAL HOUSE HARI NAGAR ASHRAM NEW DELHI 110001 | NEW DELHI | NEW DELHI | DELHI | 110014 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.7 L
Closing Date
5 Feb 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Guwahati
GE Guwahati Satgaon, Guwahati 27
Consultancy for Structural Rehabilitation work including Testing of Structural members of 240 Transit camp Bldg (G5)storey Remedial measures to be undertaken for strengthening and its satisfactory completion before occupation under GE Guwahati
2020_MES_316447_1
3002/14/E3 dt 20 Jan 2020
Limited
Consultancy Services
Works
60 days
GE Guwahati
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
7 Feb 2020
23 Jan 2020
7 Feb 2020
23 Jan 2020
5 Feb 2020
28 Jan 2020
25 Jan 2020 - 27 Jan 2020
30 days
Amount
(a) Ph- I: - The consultant shall prepare detailed report for all the testing results carried out as below and necessary remedial measures to be undertaken to strengthen the structure of bldg. Tests to be carried out are as follows:- (i) Rebound Hammer Test( As per Standard) -60 Nos (ii) Ultrasonic Pulse Velocity Test -60 Nos (iii) Half Cell Potential Test -12 Nos (iv) Rebar Scanning– 01no (v) CAPO Test(As per ASTM C900)-08 Nos (vi) Necessary transportation (vii) Necessary Scaffoldings for G+5 storied bldg at various places for the above bldg. Preparation and submission of compressive report duly vetted by IIT/ Govt Engg degree College to GE Guwahati based on findings from testing data, interpretation of results, conclusions and final recommendation along with sketch indicating locations of the test and distress areas as detailed in quotation are deemed to be included in quoted rates . (b) Ph- II:-Site visits during execution of work (03Nos) at appropriate stages of execution of rehabilitation methodology suggested. (c) Ph- III: - After completion of entire rehabilitation work necessary certificate from same IIT/Govt Engg College for structural soundness and satisfactory fitness of the bldg. for occupation to be submitted.
Note : (i) The lump sum amount quoted by the consultant shall also include for all expenses like transportation, boarding, lodging etc in connection with meeting with client regarding the subject work and nothing extra shall be paid to the consultant by client on this account (ii) The lump sum amount quoted by the consultant shall also be inclusive of all taxes.
TERMS AND CONDITIONS 1. Consultancy services as listed above shall be provided by the consultant. 2. The consultant shall provide and complete the consultancy services in accordance with the phasing stipulated in Appx “B” enclosed, to the satisfaction of the client or his authorized representative within the period stipulated. 3. The consultant shall carryout the services required in terms of this consultancy, according to accepted norms of sound engineering practices and conforming to Indian Standard Codes (Revised upto date). The consultant shall be responsible for the technical soundness and accuracy of the services rendered. 4. The consultant shall supply to the client all the documents/drawings/details as per various Appendices and Annexure forming part of the consultancy agreement.
5. Test Results & recommended rehabilitation work as required in respect of this project shall be got checked from any Indian Institute of Technology, National Institute of Technology or Govt Engg degree College under consultant’s own arrangements, before finalization recommendations. A certificate to the effect that the proposal has been so checked shall be furnished to the client by the consultant. The rate quoted shall inter alia be inclusive of getting the designs checked as aforesaid. 6. The calculation sheets, test reports and all other documents provided by the consultant in terms of this agreement to the client, shall remain the property of the client and the client shall have full right to use them in any manner for the project or for any other purpose, at the client’s sole discretion. 7. The consultant shall use the data and other information supplied by the client solely for the purpose of performing and carrying out his obligations under this consultancy agreement and shall not disclose the same to any person, except to the extent required in performance of the work of the project, and shall maintain utmost secrecy.
8. For providing the consultancy services as stipulated in the Agreement, the client shall pay fees to the consultant as quoted by the consultant. Consultant shall quote his lump sum for providing consultancy services. The payment shall be made in stages as mentioned in Appendix ‘B’. 9. The consultant shall not, without the consent in writing of the client, publish any article or photograph relating to the project. 10. If the client requires that the consultant should provide additional consultancy services other than listed in this agreement, the consultant shall provide the same at fees mutually agreed upon. The decision of accepting officer on scope of consultancy work forming part of this agreement shall be final and binding.
11. If any time after conclusion of this agreement, the client decides to postpone or abandon the project, he may, by giving seven days’ notice in writing to the consultant terminate this agreement, provided that if the project or any part thereof is postponed, the client, may, in lieu of terminating this agreement require the consultant in writing to suspend the carrying out of his services under this agreement, for the time being. If the client does not require the consultant to resume performance of services in respect of any postponed work within a period of three month from the date of the client’s requirement in writing to the consultant to suspend the carrying out of his services, such work shall be considered to have been abandoned and this agreement shall be deemed, to be terminated. 12. If this agreement is terminated in pursuance of Clause 11, the consultant shall be eligible for payment of proportionate fees for the portion of consultancy services already rendered, as assessed by the client. The client’s decision in this respect shall be final and binding; no other compensation whatsoever shall be paid.
13. If the consultant commits any breach of any of the provisions of this agreement, the client shall be entitled to cancel this agreement and on such cancellation the fees payable shall be proportionate to the services, if any, already rendered by the consultant as assessed by the client, less ten percent. 14. All payments to the consultant shall be made through crossed cheque, A/C payee by the GE Guwahati. 15. If the consultant fails to complete the work of any phase on or before the date(s) fixed for completion of that phase he shall, without prejudice to any other right or remedy of client on account of such breach, be liable to pay compensation for delay in completion of work @ 1% per week for that particular phase subject to the maximum of 10% of total value of work for the phase.
Appx 'B' The consultancy services for evaluation/assessment of structural soundness of more than 30 years old six storied building alongwith providing remedial measures for rehabilitation & restoration to enhance its life to suit further habitation as mentioned hereinafter shall be provided in three phases as under with the following time schedules :-
Phase-I Collection of all preliminary details, and discussion on various details as mentioned in Section 1 hereinafter. Carrying out tests on ground and necessary laboratory tests, analysis of tests, detail dovetailing on drawings, preparation of remedial measures for Rehabilitation work etc.
Phase-II Visit to Site during execution of work (03 Nos) at appropriate stages.
Phase-III Submission of final report for satisfactory execution of rehabilitation work on ground
Note:- Separate work orders for each Phase shall be placed by client as per actual ground requirement. The consultancy services shall consist of following scope of work which is required to be conducted/ carried out to the satisfaction of the client for the building which is more than 30 years old of brief specifications as under. Consultant shall furnish structural soundness of building based on tests given hereinafter under Section 2(c), engineering practice/concepts and any other methods/tests required to be carried out to arrive the conclusion. Consultant shall give detailed remedial measures required to repair the distress and furnish details for retrofitting/restoration & rehabilitation, to enhance its life to suit further habitation.
BRIEF SPECIFICATION OF BUILDING:- (a) Type of Building : (G+5) storied with length approx. 45.13 m & width approx. 43.92m & 36.74m (b) Construction : RCC Framed construction (c) Foundation : RCC (d) Structure components: RCC Columns , Beam with brick partition (e) Roof/floor slabs : RCC Slab (f) Slab support/beams: RCC Beam (g) Plaster : Cement Plaster (h) Roof treatment : PCC Padding
SECTION 1:- (A) Preparation of survey report of structure w.r.t. its present condition, ageing, exposure condition, habitation, pattern of distresses, surrounding environment, weathering effects, ground water table, drainage system, internal & external services, change pattern of loading, maintenance, collection of ground data etc. (B) Preparation of drawings & sketches and to demarcate location extent of distress, pattern of cracks, shear failure, repair & retrofitting etc.:- (C) The consultant shall get the above mentioned drawings checked from GE Guwahati for correctness.
SECTION 2:- (A) Condition Assessment and Analysis:- (a) Identification of cause of problem in building (b) Effects of earlier repair work & restorations (c) Effects/extent of deterioration due to leakage, seepage from roof, toilets, roof top tanks etc. (d) Carbonation in RCC slabs, spalling of reinforcement covers and plaster. (e) Distress if any caused due to over burden of structure by addition/alteration. (f) Seepage if any through basement, foundation and side walls. (g) Ventilation (h) Roof treatments by PCC padding & present polymer based products. (j) Thermal effects such as shrinkage, creep, expansion etc. (k) Relative humidity progression (l) Assessment of residual strength of critical section and members
(B) Condition Mapping: - Following shall be identified and marked on the drawing/sketches:- (a) General defects & deterioration such as dampness, seepage, erosion, signs of ageing etc. (b) Structural cracks (c) Areas of distresses (d) Repair & retrofitting with sketches & sections
(C) Mandatory Field and Laboratory Tests: - Following main tests shall be carried out to assess the soundness of the structure in terms of IS 13311 Pt I of II, relevant IS, BS & International codes. (i) Rebound Hammer Test( As per Standard) -60 Nos (ii) Ultrasonic Pulse Velocity Test( As per Standard) -60 Nos (iii) Half Cell Potential Test( As per Standard) -12 Nos (iv) Rebar Scanning(G+5 Storied Col Beam Str)– 01no (v) CAPO Test(As per standard ASTM C900)-08 Nos (vi) The above minimum test are required to be carried out at site to check soundness of building. However if more no of tests over to specified in each case are required to carry out arrived final result the same shall be carried out without any extra cost to the client. (vii) The test result shall be carried out in the present of nominated representative of client and all the testing shall be recorded by a video graphic content shall be submit along with the detailed project report. (viii) The location of test where it has carried out shall be made good to the satisfaction of the GE.
(D) Analysis of Tests and Data:- After collection of various ground data, field & laboratory tests, analysis shall be carried out to arrive the reasons/causes of distress & extent of deterioration occurred over a period of time & durability and adoption of protective measure for each cause. All details shall be furnished step by step to arrive the conclusion.
(E) Submission of Report :- Irrespective of whether the consultant recommends the present building suitable for present habitat i.e. single living accommodation for troops or not, the consultant shall submit recommendation/suggestion to make more smooth utilization of building in future for purpose other than present habitation along with final report containing following :- (a) Detailed report containing details given Section 1 & 2 above. (b) All test results observations and results thereof along with video graphic recording in DVDs. (b) Architectural drawings and sketches. (c) Soft copy of architectural drawings, analysis etc. (d) A power point presentation on the complete project report after preparation of detailed report in the office of the client by taking prior appointment from the client for the time and date of presentation.
(K) Bills of Quantities (BOQ) and Estimation:- Consultant shall furnish detailed scope of work and specifications for each item of work required to be carried out for rehabilitation of the building, to GE Guwahati.
perceptions
SSA TECHNO CONSTRUCTION PVT LTD
stage.html
html • 0.02 MB
finance_355567.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .