Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹37.8 L+₹71,440.50 (1.93%)Rejected-AOC B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹46.0 L+₹8.9 L (24.0%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category c(vi) |
Tender Value
₹49.8 L
EMD Value
₹99,600
Closing Date
6 Mar 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
PROVISION OF FLAME PROOF LIGHT FITTING IN STRONG ROOM AT GROUND FLOOR OF MAIN BUILDING, UPGRADATION OF FIRE SYSTEM AT DIPR, ELECTRIC AND CIVIL WORK SUPPORT FOR THE NEW HUMAN CLIMATIC CHAMBER INSTALLATION AT DIPAS AND PROVISION OF 05 WATER COOLERS AND
2020_MES_322920_1
GE/RND-71/DLI/2019-2020
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class D, a(i), b(i) and c(vi)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹99,600
Yes
27 Mar 2020
7 Feb 2020
9 Mar 2020
7 Feb 2020
6 Mar 2020
15 Feb 2020
Amount
Excavating in hard / dense soil in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for brick work with sub-class 'B' bricks old size straight or curved on plan exc. 6.00 m mean radius built in CM (1:6) complete all as specified and directed.
M&L for brickwork with sub-class 'B' bricks old size straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Taking down cement plaster on brick walls, raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in CM(1:4) on brick walls or concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
All as per item No 6.00 above but in CM (1:6).
M&L for rendering 5mm thick in CM(1:3) on ceiling finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper over two coat of wall care putty (1mm thick each coat) etc complete all as specified and directed.
M&L for preparation of newly plastered surface in ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered untreated wall surface and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) finished the surface even & smooth without using extra cement complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type-B1 (using 20mm graded stone aggregate) in lintels upto 1.5 mtr clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) 1:2:4 type B1 (12.5mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like finished even and smooth without using extra cement complete all as specified and as directed. Note: re-inforcement shall be measured and paid separately.
S&F mild steel TMT reinforcement bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as ser item No. 15.00 above but 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.
Supply only integral water proofing compound complete all as specified and as directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for flat surfaces complete all as specified and as directed.
Use & waste of formwork for rough concrete surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
M&L for 40mm thick damp proof course in cement concret 1:2:4 type B-0 to horizontal or vertical surfaces incl necessary formwork complete all as specified and as directed.
M&L for non skid ceramic ,coloured tiles (designer tiles), 7 to 8 mm thick (square/rectangular) area exc 0.11sqm but n. exc 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for glazed ceramic coloured tiles (designer tiles) 450x300x7mm thick on vertical surfaces i.e dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering as backing coat of 10mm thick in CM (1:4) complete all as specified and directed.
S&F 10 litres capacity, PVC valveless with syphonic action type flushing cistern low level white with inlet, ball valve float, incl bracket, PVC flush & pipe fixed complete all as specified and directed.
S&F in repair vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and as directed.
S&F in repairs, 32mm dia, PVC waste pipe for WHB complete all as specified and directed.
S&F CP brass bib taps, fancy type 15mm size screwed for iron pipe fixed complete all as specified and directed.
S&F angle valves 15 mm bore, fancy type chromium plated, brass bib taps screwed for iron pipe and fixed complete all as specified and directed.
S&F stop valves concealed type CP brass 15mm dia, fancy type, CP screwed for iron pipe and fixed complete all as specified and directed.
S&F 15mm dia brass, CP, fancy type, Pillar taps of brass with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F PVC connection 600mm long with PTMT nuts 15mm size complete all as specified and as directed.
S&F 125mm size chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union
S&F tubular towel rail CP 20mm dia brass chromium plated 'D' type 600cm long between flanges complete all as specified and directed.
S&F CP grating 125mm dia fixed on floor/nahani trap fixed with cement mortar complete all as specified and directed.
S&F 75mm outlet dia of PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F vitreous china squatting pan, ''Orissa'' pattern, size 630mm x 440mm white with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F PVC (SWR) 'P' trap 110/110 mm bore complete all as specified and as directed.
S&F 110 mm PVC (SWR) WC connector bent pipe complete all as specified and as directed.
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
All as per ser item No 38.00 above but fixed to walls.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F 75mm bore PVC(SWR) bends any radius complete all as specified and as directed.
S&F 110 mm PVC (SWR) junction single, (single 'T' equal or unequal complete all as specified and as directed.
S&F 110mm bore PVC(SWR) bends any radius complete all as specified and as directed.
S&F 110mm bore PVC(SWR) reducers complete all as specified and as directed.
S&F 32mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S&F Soap dish, vitreous China white, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F 20mm outer dia 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
All as per ser item No. 47.00 above but 25mm.
S&F 16 to 40mm outer dia making connections of PP-R distribution branch with PP-R main by providing and fixing tee incl cutting and making fusion joint etc complete all as specified and as directed.
S&F 20mm outer dia PPR ball valves (brass insert) as per requirement of the site complete all as specified and as directed.
All as per item No 50.00 above but 25mm outer dia
S&F 1000 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layer hoisted and fixed in position complete all as specified in SSR Part I
S&F 20mm dia nipple suitable for HDPE water tank (Min wt 20mm-45gms.
All as per ser item No. 53.00 above but 25mm dia.
S&F 1.00 mm thick plain, galvanised, mild steel sheeting in stepped flashings of size complete all as specified and directed.
S&F 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm-210 gms) complete all as specified and as directed.
Taking down steel window/ ventilator chowkhat with shutter area not exc. 1.5 sqm complete all as specified and as directed.
S&F aluminium anodised section window made out of aluminium frame of section 63.50x38.10x1.60mm thick and shutter fixed or openable and horizontal and vertical members of aluminium anodised section 47.50x44.50x1.60mm thick with aluminium beading, rubber gasket, aluminium fittings such as 02 Nos aluminium hinges 75mm long, 02 Nos aluminium anodised tower bolts 150mm, stay rod and handles 125mm alongwith AC openign wherever required by users/site requirement complete all as specified and directed.
S&F aluminium anodised grill with 6x4.5mm thick section, 10cm centre to centre spacing complete with U channel all round fixed in window with screws complete all as specified and directed.
S&F 4.00mm thick sheet glass ordinary quality and glazing pins and rubber beading etc. in aluminium door, window & partitions exc 0.5 Sqm in each pane complete all as specified and directed.
All as ser item No. 60.00 above but n. exc. 0.5 sqm.
S&F powder coated (50 micron thick) aluminium frame size 63.50x38.10x1.60 mm thick for doors, windows and ventilators with one or more rebates incl jointing cleats for fixing etc complete all as specified and directed.
S&F powder coated (50 micron thick) aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles size & material 2 Nos in each door, size & material, hinges, aluminum snap beading screws etc. complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised sliding door bolt with hasp & staple clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F butt hinges 100mm long , extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
S&F 150mm size aluminium handles, cast type, anodised complete all as specified and directed.
S&F Door closer (die cast body) hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed.
S&F for Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) incl fixing bolts complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Returning, filling in, hard / dense soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed at a level n. exc. 1.5m above the starting point incl loading unloading complete all as specified and directed.
Taking down chowkhats or frames wth shutters (without taking off shutters from frame) exc 1.5 Sqm but n. exc 4 Sqm including making good complete all as specified and directed.
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F 125mm extruded aluminium alloy with galvanised alum hinge pin anodised, type B-1 and fixed complete all as specified and directed.
M&L for Framed work such as grills, gratings, etc.. With ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work con-forming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for mild steel Plates (Plain), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe.290 (Gde-E-165) complete all as specified and as directed.
S&F in repair vertical blinds consisting of alum head rail,vanes/louvers 100mm wide of approved tint and traverse cord complete fixed in position complete all as specified and as directed.
M&L for prepartion of new or untreated steel surfaces and applying two coat of synthetic enamel (ordinary tint) painting on steel surfaces of any description, over 10 cm in width or girth, not otherwise described complete all specified and directed.
Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for laying UG cables of various sizes complete all as specified and as directed.
All as per item No. 81.00 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm in any type of soil.
Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and as directed.
Supply and spread clean dry river sand in trenches including leveling, punning for cushioning of cables complete all as specified and as directed. Note : Punned thickness of sand cushioning shall be measured.
Disconnecting, taking out from trenches serviceable LT UG cable of size 25 Sqmm to 35 Sqmm, 3.5 core and relaying in new position after taking proper shut down all as directed. Note : Excavation and earth work will be measured and paid separately.
All as ser item No. 87.00 above but 300 mm to 400 Sqmm 3.5 core.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE 300 Sqmm to 400 Sqmm. Note:- Excavation, returning filling in removing, sand cushioning, brick etc shall be measured and paid separately under respective items of work.
Taking down the existing outdoor panel from its position and Refixing the same at new position after fixing of cables with necessary nuts, bolts etc complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth strip 32 x 6 mm by means of nuts bolts, check nut and washers of galvanised iron strip 32 x 6 mm earth lead with including 40 mm dia GI pipe (medium grade) and connected to main switch board as directed including concrete pit in PCC (1:3:6) type C1 precast RCC (1:2:4) type B1 cover slab 40cm x 40 cm x 40mm reinforced with 8 mm dia deformed bar @ 5 cm c/c with one handle for lifting made out of 8 mm dia MS bar, funnel, wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 of SSR Part-I.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6 mm galvanised iron strip complete all as specified and directed.
Supply and laying in repair cable XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade 3.5 core 95 sqmm complete all as specified and directed.
All as per ser item No. 94.00 above but 35 Sqmm.
All as per ser item No. 94.00 above but 300 sqmm.
M&L for PCC 1:4:8 Type D-2 (using 40 mm graded stone aggregate) or foundation of Panel and re-surface cable route complete all as specified and directed.
Taking down carefully point wiring copper/aluminium (light, fan, socket, and power) complete (fittings such as switches ceiling roses, pendent regulators sockets etc complete and making good the disturbed surface of wall, floor etc. complete all as specified and as directed.
M&L for point wring for one light/ceiling fan controlled by one switch with 1.5 sqmm nominal area) PVC insulated and PVC unsheathed multi stranded copper conductor cable FRLS in and including concealed PVC conduit 20 mm dia medium duty ISI marked, including suitable new GI sunken boxes, modular frame and cover plate for fixing of modular switches as per required point in that board, flush to surface for one light point, fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 sqmm copper conductor cable FRLS connected to common earth duly complete including cutting, chasing the surface and making good the same in CM 1:6 complete all as specified and directed. Note : Switches, Sockets etc shall be measured and paid for separately under appropriate items of BoQ.
All as per item No 99.00 above but for one socket point out let 3 pin 5 Amp in independent board.
All as per item No 99.00 above but for one socket point out let 3 pin 15 Amp with 2.5 sqmm PVC copper conductor and 2.5 sqmm PVC insulated copper conductor as earth continuity conductor.
M&L for point wring for one light/ fan controlled by one switch with 1.50 Sq mm single core PVC insulated unsheathed FRLS cable 1100V grade for phase and neutral with multi stranded copper conductor drawn through and including Stove enamelled steel conduit 20 mm dia and conduit accessories including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, FRLS PVC insulated copper solid conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed.
All as per item No 102.00 above but for one socket point out let 3 pin 15 Amp with 4 sqmm FRLSH PVC copper conductor and 4 sqmm PVC insulated copper conductor as earth continuity conductor.
S&F modular switch flush type 5/6 Amps 230V AC complete one way complete all as specified and directed.
S&F one switch and one socket modular type 5 PIN 5 Amp 230 Volts AC complete all as specified and directed.
S&F one switch and one socket modular type 3 PIN 6/16A Amp 230 Volts AC complete all as specified and directed.
S&F regulator for ceiling fan modular electronic step type 120watt- 2module suitable for 1200/1400mm ceiling fan complete all as specified and directed.
S&F ceiling rose surface type bakelite 65x50mm two to three terminal 230V complete all as specified and directed.
Taking down of existing Ceiling/ Exhaust fan of any size and refixing the same after repair of the fan including painting marking of MES Number and testing the serviceability of the fan complete all as specified and directed.
S&F sheet metal enclosure, single pole and neutral with two pin and earth plug and socket complete with one single pole MCB SP, C Curve type of capacity 25 Amp, 240V, 10 KA complete all as specified and directed.
M&L for submain wiring along with earth wire with the 2x4 Sqmm+1x4 Sqmm earth wire of FRLS PVC insulated copper conductor single core cable in and including concealed conduit pipe 25 mm external dia medium grade including all accessories complete all as required or all as specified and as directed.
M&L for submain wiring along with earth wire with the 4x6 Sqmm+2x6 Sqmm earth wire of FRLS PVC insulated copper conductor single core cable in and including concealed conduit pipe 25 mm external dia medium grade including all accessories complete all as required or complete all as specified and directed.
S&F of LED tube light along with fixture 4 feet, 20 Watt and making all electric connections with two core PVC insulated, PVC sheathed copper conductor flexible cable 1.5 sqmm including taking down old unserviceable light fitting etc complete all as specified and directed. Make: C&S Cat Part No. LTIC00120WLED/WD or equivalent of Bajaj/ Philips.
S&F of LED aluminium extruded suspended light along with fixture 36 Watt and making all electric connections with two core PVC insulated, PVC sheathed copper conductor flexible cable 1.5 Sqmm including taking down old 36 watt tube light fitting etc complete all as specified and directed. Make: Cat Part No DESTELLO70LP/S36WLED840SPMMAWH of Havells or equivalent in Bajaj/Philips.
S&F in repair LED flood light fitting LED Flood Light with pressure die cast aluminium housing , complete with all accessories of 30 W. Make: Cat Part No LTEFI30WHPLED of C&S or equivalent in Bajaj/ Philips.
S&F in repair MCB SPN 63 Amp 10 KA C' series complete all as specified. Make: Cat part No. DHMGCSNF006-032 of Havells/Legrand/GE.
S&F in repair MCB SP 6 Amp to 32 Amp sp 10 KA C' series complete all as specified and directed. Make: Cat part No. DHMGCSPF006-032 of Havells/Legrand/GE.
S&F in repair MCB FP 100 Amp 10 KA C' series complete all as specified and directed. Make: Cat part No. DHMJCFPF100 of Havells/Legrand/GE.
S&F in repair MCCB TP 415 volts 50 Hz , 100 amps, with rupturing capacity 36KA complete the existing panel complete all as specified and as directed.
S&F in repair of MCB distribution board double door Horizontal type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coated, TPN 6 way. 415 Volts with bus bar rating 200 Amps, including grouting in the wall, cutting & chasing etc complete all as specified and as directed.
All as per ser item No. 120.00 above but 8 way.
S&F rigid non- metallic concealed PVC conduit of size 25mm dia inclusive of all tees, bends, elbow, reducers, bell mouth tube ends and fixing accessories such as couplers. locknuts, saddles, pipe hook etc over the surface/recess complete all as specified and directed.
Taking down the exhaust fan from its position and deposit to MES store complete all as specified and directed.
S&F wall mounted fan 400mm sweep complete all as specified and as directed.
S&F PVC Exhaust fan 250 mm sweep with louvers complete with flexible copper cable 2X1.5 sqmm complete all as specified and directed.
S&F in repair LED Mirror light fitting with fixture 9 Watt and making all electric each connections with two core PVC insulated, PVC sheathed copper conductor flexible cable 1.5 mm complete all as specified and directed. Make: Cat Part No LHESABP6IN1W009 of Havells or equivalent in Bajaj/ Philips.
M&L for earthing with Galvanised iron earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top edge of earth plate not less than 1.5 metre below GL connected to GI earth Strip 25 x 4 mm connected to earth plate electrode by means of GI nuts, bolts & washers, earth wire protected with & including 40 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long with & including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm watering arrangements with 20 mm GI medium grade pipe ISI marked, GI funnel with GI wire mesh, filling with mixture of common salt & charcoal, necessary excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as shown in electrical plate No 3 of MES Schedule Part I,
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25x4mm galvanised iron strip complete all as specified and directed.
Supply & fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+earth ll complete all as specified and directed.
S&F LED flame proof type light fitting 1X 20W with IP65 protection including integral reflector and recommended for gas/ vapour group of IIA & IIB , pre-wired and including connecting up with twin core twisted flexible FRLS copper conductor with suitable size complete with fixing arrangement all as directed and specified. Model No EXTN1LT8-16/20 of Make Crompton or equivalent Bajaj/Havells..
S&F flame proof exhaust fan 450 mm sweep 220/230 volt AC 1440 RPM,CFM 4000, complete with fixing arrangements including taking down the old unserviceable exhaust fan and deposit to MES Yard, complete all as specified and directed. Cat No EF/140 of SUDHIR or equivalent make of BAJAJ/CROMPTON/HAVELLS.
S&F flame proof ceiling fan 1200 mm sweep 220/230 volt AC , complete with fixing arrangement incl taking down the old unserviceable ceiling fan and deposit to MES Yard, complete all as specified and directed. Cat No CF/193 of SUDHIR equivalent make of BAJAJ/CROMPTON/HAVELLS.
S&F flame proof ceiling fan regulator, steped type complete with fixing arrangement all as specified and directed. Cat No RI/OA/1010 of SUDHIR equivalent make of BAJAJ/CROMPTON/HAVELLS.
S&F FLP Flexible Metalic Hose Conduit of size M20 / 3/4" Conduit M x M / FM x M/ F x F 500 mm.
S&F FLP Flexible Metalic Hose Conduit of size M20 / 3/4" Conduit M x M/FM x M/ F x F 300 mm.
M&L for Earthing with copper earth plate electrode 600 x 600 X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal GL) with top edge of earth plate not less than 1.5 meter below GL connected to copper earth Strip 20 x 3 mm connected to earth plate electrode by means of GI nuts, bolts, check nut & washers of copper earth strip 20X3 mm earth lead with including 40 mm dia medium grade ISI marked GI pipe and connected to main switch board as directed including concrete pit in PCC (1:3:6) type C1 precast RCC (1:2:4) type B1 cover slab 40 cmX 40 cmX 40 mm reinforced with 8 mm dia deformed bar @ 5cm c/c with one handle for lifting made out of 8 mm dia MS bar, funnel with wire mesh, 20 mm bore GI pipe (medium grade) for watering including charcoal and salt in alternative layers necessary excavation and earth work in any type of soil and testing complete all as shown on electrical plate No-3 on SSR Part-I.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 20x3 mm copper strip complete all as specified and directed.
Supply, Installation, Testing and Commissioning in repair of 2 loop Addressable fire alarm panel Epoxy powder coated, with loop capacity of 126 devices per loop, IP30 protection, 16 zonal LED indicators, 2 programmable sounder circuit, large graphic display, sensitive adjustment and drift compensation, variable language and character settings and supports. The panel should have an integral 240 X 64 pixel graphic LCD and built-in 220 V AC power supply with battery charger capable of charging 02 nos X 07 Ah 12 VDC batteries. The panel should SLC support both 'A' class and 'B' class wiring with user friendly with communication facility to monitor and control the FACPs from a single window un ambiguous visual & unlimited event record facility interface and should have 05 nos digital inputs for remote silence alarm, reset, fault input for open or short circuit etc and daily/weekly/monthly/yearly backup facility single/ multi mode floor/ wall mounted configuration facility floor configuration using files. The Fire Alarm control panel shall also monitor the status of intend connections and interfaces including charge and batteries. The panel should also have provision for graphic software with TCP/IP modular and provision for BMS integration over MODBUS protocol converter. The panel should be EN54-2 and EN54-4/LPCB/UL/VDS approved. The panel should clearly indicate the following indications:-
(i) POWER SUPPLY ON - green LED indicator (ii) FIRE ALARM - red LED indicator (iii) PRE-ALARM - yellow LED indicator (iv) ON TEST - yellow LED indicator (v) BUZZER SILENCED - yellow LED indicator (vi) DELAY ACTIVE - yellow LED indicator (vii) MORE EVENTS - yellow LED indicator (viii) GENERAL DISABLEMENT - yellow LED indicator (ix) GENERAL FAULT - yellow LED indicator (x) POWER FAULT - yellow LED indicator (xi) SYSTEM FAULT - yellow LED indicator complete all as specified and directed. Make: Apollo, Cat Part No Nexgen Syncro/Notifier (Honeywell)/Sharack/Hochik
Supply, Installation, Testing and Commissioning in repair of Active Repeater panel Epoxy powder coated, with IP30 protection, 16 zonal LED indicators, 2 programmable sounder circuit, large graphic display, sensitive adjustment and drift compensation, variable language and character settings and supports Apollo protocols complete all as specified and directed. Note: The panel should be EN-54/LPCB/UL/VDS approved. Make: Apollo, Cat Part No Nexgen Syncro /Notifier (Honeywell)/Sharack/Hochiki
Supply, Installation, Testing and Commissioning in repair of of Addressible Heat Detector with a thermistor temperature sensor, with operating voltage 17-28V DC and operating temperature 32 to 100 degree, complete all as specified and directed. Note: The detector should be EN-54/LPCB/UL/VDS approved. Make: Apollo, Cat Part No 58000-400/Notifier (Honeywell)/Sharack/Hochiki.
Supply, laying & connecting in repair of multi stranded copper conductor PVC insulated and unsheathed FRLSH cable 2 core 1.5 sqmm, ISI marked complete all as specified and directed.
Supply, laying & connecting in repair of multi stranded copper conductor PVC insulated and unsheathed FRLSH cable 4 core 1.5 sqmm, ISI marked complete all as specified and directed.
Supply, Installation, Testing and Commissioning in replacement of conventional Hooter complete all as specified and directed. Make: Safezone/Notifier (Honeywell)/Sharack/ Apollo or equivalent.
Supply, Installation, Testing and Commissioning of plug-in type ionisation addressable analogue smoke detectors with twin blinking LED and this will glow in case of Fire with 5 levels of sensitivity bands for adjustment of clean / harsh area and day & night mode to avoid false alarm. The operating temperature of the detector should be from (-)30 to 70 degree. The detector should have drift compensation and should have non volatile memory to have his own event log. It should have a facility to act as conventional detector in case of panel failure with operating voltage 17-28V dc, complete all as specified and directed. Note: The detector should be EN-54/LPCB/UL/VDS approved. Make: Apollo, Cat Part No 58000-500/Notifier (Honeywell)/Sharack/Hochiki.
Supply, Installation, Testing and Commissioning in repair of dust and vermin proof addressable analogue manual call boxes with flashing LED with isolator to initiate audio visual alarm in case of human detection of fire complete all as specified and directed. Note: The manual call point should be EN-54/LPCB/UL/VDS approved. Make: Apollo, Cat Part No SA5900-908 /Notifier (Honeywell)/Sharack/Hochiki.
Supply, Installation, Testing and Commissioning in repair of addressable loop sounder cum strobe suitable for audio and visual alarm siren upto 90 dBA @ 1 m and 15 cd flashing complete all as specified and directed. Note: The sounder cum strobe should be EN-54/LPCB/UL/VDS approved. Make: Apollo, Cat Part No 45681-393/Notifier (Honeywell)/Sharack/Hochiki
Supply, Installation, Testing and Commissioning in repair of addressable control module required for various outputs to other systems like signal to switch off AHU, access control etc. complete all as specified and directed. Note: The control module should be EN-54/LPCB/UL/VDS approved. Make: Apollo, Cat Part No SA4700-102 //Notifier (Honeywell)/Sharack/Hochiki.
Note for Ser No 139 to 149:- Design and Testing of Fire alarm:- (i) Design of the proposed fire alarm system complete in all respect will be submitted by the contractor from the Original Manufacturers/ Manufacturers authorized Distributor/ dealer by considering Sch BOQ items and ground requirements and submit the same to the ccepting officer through concerned Engineer-in- charge along with Make approval letter. (ii) The entire work shall be carried out by the/ through the manufacturers Engineers/ Manufacturers recommended consultancy/ firm/ team being a specialized nature of work. (iii) After completion of entire work on the ground in all respects and before issuing of the completion by Garrison Engineer, the contractor is responsible to carry out testing of entire fire alarm system in all respects as per manufacturers recommendations by their Engineers in the presence of Officer as detailed by the Accepting officer, Users representative and Engineer-in-charge etc. (iv) The quoted unit rates or the above items shall deemed to be included and no extra payment on this account will be entertained.
Supply and fixing in replacement of Response Indicator complete all as specified and directed. Make: Apollo, Cat Part No 53832-070/Notifier (Honeywell)/Sharack/Hochiki
M&L for fixing in repair of MS conduit ISI marked of size 25mm on wall/ ceiling with clamps, screw and all connected items complete all as specified and directed.
M&L for fixing in repair of MS conduit ISI marked of size 20mm on wall/ ceiling with clamps, screw and all connected items complete all as specified and directed.
S&F in repair of Hose Reel pipe with hose reel drum, ISI marked of length 30 Mtr, 20 mm dia with nozzle and all accessories complete all as specified and directed.
M&L for one point wiring of any length as per site requirment with PVC insulated FR LS unsheathed copper conductor cable of size 1.5 sqmm including earth wire of size 1.5 Sqmm in and including PVC casing caping including modular metal box, inner and outer modular top sheet top cover, for light for one 3 pin socket outlet 5 Amps independent all as specified and as directed .
S & F modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed.
M&L for one power point wiring of any length as per site requirment with PVC insulated FR LS unsheathed copper conductor cable of size 4 sqmm including earth wire of size 4 Sqmm in and including PVC casing caping including modular metal box ,inner and outer modular top sheet top cover, for light for one 3 pin socket outlet 16 Amps independent all as specified and as directed .
S&F modular socket 6/16 amp-2/3 pin combined 2 module complete all as specified and directed.
S&F Modular switch 1 way 16 Amp 1 Module complete all as specified and directed.
S&F GI pipe medium grade of size 15mm dia for connection of water supply to Water cooler from OH Tank complete including all GI fittings etc complete all as specified and directed.
S&F gun metal gate Valves 15mm dia, with iron wheel screwed both ends for iron pipe complete all as specified and directed.
M&L for water cooler fully stainless steel, electric driven single phase having approx. storage capacity 120 ltrs and nominal cooling capacity 60 ltrs per hrs with inbuilt voltage stabilizer of suitable capacity complete star rated with and including connecting up elect. and water supply connections stop valve, PVC connection etc complete all as required at site. testing & commision all as specified and directed. Make:-Usha/Bluestar/Voltas or equivalent.
Supply, Installation, testing and commissioning desert cooler (overall minimum size 65x65x100 CM) made out of galvanised sheet, depth of water tank shall be 11 inch (Minimum) electric driven 230 Volts single phase 50 Hz electric supply having minimum nominal air flow capacity of 5000 cubic meter per hour complete including 380 mm sweep cooler fan motor and submerssible pump including provision of PVC braided connection and float valve with best quality grass pad set complete all as specified and directed. Make: Khaitan/BAJAJ/CROMPTON
S&F Ball brass valves of size 15 mm high pressure with polythene float and flynut screwed for iron pipe or brass ferrule and fix in the desert cooler complete all as specified and as directed.
M&L for fabrication of angle iron frame (Size 1.2x.65x.65 mtr) for mounting desert cooler with angle iron 40x50x5 mm including painting with one coat of red oxide primer and two coat of synthetic enamelled paint gray colour all as specified and as directed.
New Era Engineers
Continental Engineers and contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .