NBCC Bhawan
NBCC Bhawan
Construction of 03 nos. G plus 5 Double Occupancy Hostels at IIM Sambalpur, Odisha Under Phase-II
NBCC/SBG/Odisha/NIT/26-27/66~EW1d20860f12bde0b10887d579
NBCC/SBG/Odisha/NIT/26-27/66
Open Tender-Domestic
Civil Works - Buildings
NBCC Bhawan
₹59,000
₹41.6 L
17 Oct 2026
17 Oct 2026
7 Nov 2026
17 Oct 2026
7 Nov 2026
26 Oct 2026
BILL OF QUANTITY (CIVIL ITEMS)
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
1.0 CARRIAGE OF MATERIAL
1.1 By Mechanical Transport including loading,unloading and stacking
1.1.2 Carriage of earth
1.1.4 Carriage of excavated rock
2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting
out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in
foundation over areas (exceeding 30cm in depth , 1.5 m in width or 10 sqm on plan),
including disposal of excavated earth, for all leads and lifts, disposed earth to be levelled and
neatly dressed.
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated
soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.
in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and cum 6055.72 6055.72 196.00 11,86,921.12
watering, lead up to 50 m and lift upto 1.5 m.
2.25(a) Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead
of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in cum 686.00 686.00 700.50 4,80,543.00
foundation trenches, plinth, sides of foundation etc. complete for all lift.
2.26 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or
stacked materials.
2.26.2 Ordinary or hard rock
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete.
2.34 Supplying chemical emulsion in sealed containers including delivery as specified.
2.34.1 Chlorpyriphos/Lindane Emulsifiable concentrate of 20%. Ltr. 896.00 896.00 234.75 2,10,336.00
2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite
2 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
2.35.2.1 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25
litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane
E.C. 20% with 1% concentration
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level
4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural sources) cum 617.42 617.42 7,294.70 45,03,893.67
4.3 Centering and shuttering including strutting, propping etc. and removal of form for all heights :
4.3.1 Foundations, footings, bases of columns sqm 2164.63 2164.63 392.15 8,48,859.65
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm
nominal size, well rammed and consolidated and grouted with fine sand, including necessary
excavation, levelling & dressing & finishing the top smooth.
5.1.2 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 °
landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral
stair cases above plinth level up to floor five level, including the cost of centering, shuttering, cum 124.36 124.36 9,045.75 11,24,929.47
finishing and excluding reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone
aggregate 20 mm nominal size).
5.9 Centering and shuttering including strutting, propping etc. and removal of form for all heights :
5.9.1 Foundations, footings, bases of columns etc. for mass concrete. sqm 3594.50 3594.50 392.15 14,09,583.18
5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 6463.60 6463.60 927.25 59,93,373.10
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sqm 9323.60 9323.60 736.40 68,65,899.04
5.9.6 Columns, Pillars, Piers, Abutments, posts and Struts Sqm 7207.20 7207.20 961.30 69,28,281.36
5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 171.18 171.18 764.95 1,30,944.14
5.9.16 Edges of slabs and breaks in floors and walls. 0.00 0.00
5.9.19 Weather shade, chajjas, corbels etc. including edges. sqm 360.00 360.00 951.10 3,42,396.00
5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position
and binding all complete upto plinth level
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 141331.465 141331.47 107.85 1,52,42,599.04
5.22 A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500 D or more. kg 331394.05 331394.05 107.85 3,57,40,848.29
5.33 Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to
3 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
5.33.1 All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 2040.00 2040.00 9,504.75 1,93,89,690.00
5.33.1.2 Concrete of M30 grade with minimum cement content of 350 kg /cum cum 352.56 352.56 9,655.70 34,04,213.59
5.33.2 All works above plinth level upto floor V level
5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum cum 1765.26 1765.26 9,860.40 1,74,06,169.70
5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum cum 2907.00 2907.00 10,011.35 2,91,02,994.45
5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
5.35 Add for using extra cement in the items of design mix over and above the specified cement
content therein. quintal 3424.73 3424.73 733.50 25,12,039.46
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in foundation and plinth in:
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 70.72 70.72 7,132.25 5,04,392.72
6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of
half brick masonry.
6.44 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : Mtr 634.40 634.40 59.45 37,715.08
6.34.1 Brick work with non modular fly ash bricks conforming to IS:12894,
class designation 10 average compressive strength in super structure cum 1431.34 1431.34 8,962.35 1,28,28,170.05
above plinth level up to floor V level in : Cement mortar 1:4 (1 cement : 4 Coarse sand)
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of
required size, approved shade, colour and texture laid over 20 mm thick base cement mortar
1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching
pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give
high gloss finish etc. complete at all levels.
8.2.2 Granite stone slab of colour black, Cherry/Ruby red
8.3 Providing edge moulding to 18 mm thick marble stone counters, Vanities
etc., including machine polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-in-Charge.
8.4 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and
drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. Mtr 375.96 375.96 568.55 2,13,752.06
8.5 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen
platform, vanity counter and similar location in marble/ Granite/ stone work, including
necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc.
4 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames,
wrought framed and fixed in position with hold fast lugs or with dash fasteners of required
dia & length (hold fast lugs or dash fastener shall be paid for separately).
9.1.3 Kiln seasoned and chemically treated hollock wood Cum 12.83 12.83 83,378.05 10,69,740.38
9.12 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm
thick in doors, windows and clerestory window shutters. (Area of opening for glass panes sqm 12.83 176.40 2,263.21
excluding portion inside rebate shall be measured).
9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)
nondecorative type, core of block board construction with frame of 1st class hard wood and
well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers
on both faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 539.00 539.00 2392.65 1289638.35
9.21.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws sqm 639.00 639.00 2172.10 1387971.90
26.91 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer
Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of
approved design by Engineer-in -charge which are machine cut for duct/ shaft covering,
partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade),
calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic
additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum
and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2,
modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with sqm 666.00 3437.15 2196338.85
properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on
M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying
a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per
requirement at site with necessary stainless steel fasteners and SS screws etc., all complete
as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat
and necessary SS fasteners and SS screws shall be paid separately
9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all
edges of flush door shutters (over all area of door shutter to be measured). sqm 540.00 540.00 462.35 249669.00
9.26 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). sqm 1000.00 1000.00 106.70 1,06,700.00
9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm
diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm
1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
9.74 Providing and fixing bright finished brass tower bolts (barrel type) with
necessary screws etc. complete :
9.74 Providing and fixing bright finished brass tower bolts (barrel type) with
necessary screws etc. complete :
9.82 Providing and fixing bright finished brass hanging type floor door stopper with necessary
screws, etc. complete.
5 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic door
closer (having brand logo with ISI, IS: 3564, embossed on the body, door weight upto 36 Kg.
to 80 Kg. and door width from 701 mm to 1000 mm), with double speed adjustment with Each 80.00 80.00 983.15 78,652.00
necessary accessories and screws etc. complete.
9.88 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a
pair of lever handles of approved quality with necessary screws etc. complete. Each 450.00 450.00 998.35 4,49,257.50
9.89 Providing and fixing chromium plated brass night latch of approved quality including necessary
screws etc. complete. Each 450.00 450.00 952.80 4,28,760.00
9.92 Providing and fixing chromium plated brass handles with necessary screws etc. complete:
9.127 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss /
matt / suede finish with high density protective surface layer and reverse side of adhesive
bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved
9.147A Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead
free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded
profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10
mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design
duly reinforced with galvanized mild steel section
made of required shape & size as per CPWD Specification, uPVC extruded glazing beads,
interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM
gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head,
comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS
1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc.
Profile of frame, sash & mullion (if required) shall be mitred cut and fusion
welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing
hardware and drainage of water etc. After fixing frame the gap between frame and adjacent
finished wall shall be filled with weather proof silicon
sealant over backer rod of approved size and quality, all complete as per approved drawing
conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel
reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-
in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with /
without high performance coatings as per design requirements and conforming to IS: 3548 &
IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government
Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed >
45 m/sec as per IS 875 — Part 3
(ii) Sites with structure height more than 20m for all wind speeds
9.147.A4 Three track three panels sliding window with two glazed & one wire mesh panels with
Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
6 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
9.147.A4.1 Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen
sash (25 mm & above) x (50 mm & above) with zinc alloy (Zamak) powder coated touch locks sqm 1567.62 1567.62 10,993.55 1,72,33,708.85
with hook. (Height upto 1.2 metre).
9.149 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC
casement window with necessary screws etc. complete. each 180.00 180.00 231.05 41,589.00
9.153 Providing and fixing steel (white power coated) crescent lock for uPVC
sliding window/ door with necessary screws etc. complete. each 900.00 900.00 198.30 1,78,470.00
STEEL WORK 0.00 0.00
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,
including cutting, hoisting, fixing in position and applying a priming coat of approved steel Kg. 7525.80 7525.80 133.70 10,06,199.46
primer all complete:
10.27 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10
mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head,
comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame ,
concrete/ masonry, etc. as per direction of Engineer-in-charge.
10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing
the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts
etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement
as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
10.29 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat
15x3 mm and nuts & bolts complete.
10.29.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness
with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns
epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should
have protective guard film of 25 micronsminimum to avoid scratches during transportation and
should besupplied in single length upto 12 metre or as desired by Engineer in-charge. The sqm 1050.00 1050.00 738.65 7,75,582.50
sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM
seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost
ofpurlins, rafters and trusses and including cutting to size and shape
wherever required.
7 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved make, in all colours, shades except burgundy,
bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed
with pigment of matching shade complete.
11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more
(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of
approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement
mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm
including grouting the joints with white cement and matching pigments etc., complete.
11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of
approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar
1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The tiles must be cut with the zero 0.00 0.00
chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet for placing the tiles gently and
11.41A.1 Double charge vitrified tile polished finish of size 0.00 0.00
11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by
manufacturer), with water absorption less than 0.08 % and conforming to |.S. 15622, of
approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of
cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm
including grouting the joint with white cement & matching pigments etc.
11.56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear
as well as curvilinear portions of the building all complete as per the architectural drawings
with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement
: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry 0.00
admixed with pigment of matching shade including rubbing , curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge.
11.56.1 Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent Sqm 765.00 765.00 4,481.30 34,28,194.50
12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone
aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3
fine sand) as per standard design : In 75x75mm deep chase
8 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet
1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) each 33.80 33.80 298.25 10,080.85
and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
12.52.3 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of
Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated
with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized
polyester on the back side with all edges sealed with the face side PVC film which goes Sqm 735.80 735.80 2,215.15 16,29,907.37
around and wraps the edges and is bonded to the edges and the back side metalized
polyester film so as to make the tile a completely sealed unit.
FINISHING: 0.00 0.00
13.1 12 mm cement plaster of mix :
13.12 18 mm cement plaster in two coats under layer 12 mm thick cement plaster
1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement
plaster 1:6 (1 cement : 6 fine sand).
Neat cement punning
13.21 Extra for providing and mixing water proofing material in cement per bag of
plaster work in proportion recommended by the manufacturers. per beg of 50kg
13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every
additional height of 3 m or part thereof.
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved
brand and manufacturer, over the plastered wall surface to prepare the surface even and sqm 12006.80 12006.80 156.05 18,73,661.14
smooth complete.
13.83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile
Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to achieve even shade and colour.
9 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
16.91 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot
path, park & lawns driveway or light & traffic parking etc. of required strength, thickness &
size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern
over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of
inter locking paver blocks into the sand bedding layer through vibratory compaction by using 0.00 0.00
plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and
pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications
& direction of Engineerin- Charge
16.91.1 60mm thick Cement concrete paver block of M-35 grade with approved colour, design &
16.78 Construction of granular sub-base by providing close graded Material conforming to
specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers
to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor
grader on prepared surface and compacting with vibratory power roller to achieve the desired
density, complete as per specifications and directions of Engineer-in-Charge.
16.78.1 With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
16.10 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity
after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating
with road roller including making good the undulations etc. and re-rolling the sub grade and
disposal of surplus earthwith lead upto 50 metres.
16.80 Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse
and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm,
aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per
specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to
be determined during trial length construction, concrete strength not to be less than 10 Mpa at cum 154.44 154.44 4,148.65 6,40,717.51
7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a
mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc.
complete as per direction of Engineer_x0002_in- charge.
16.75 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching
plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum
dewatering process and finally finished by floating, brooming with wire brush etc. complete as
per specifications and directions of Engineer-incharge. cum 207.90 207.90 9,823.80 20,42,368.02
(The panel shuttering work shall be paid for separately).
(Note:- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/ recoverable separately).
16.46.1 Providing and filling in position rubberized bitumen hot sealing compound for sealing of Per cm Width
expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. per cm width per 2043.60 2043.60 8.65 17,677.14
Using grade 'A' sealing compound conforming to IS: 1834 m length
10 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement
concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarsesand), including making joints with or without grooves (thickness of joints
except at sharp curve shall not to more than 5mm), including making drainage opening
wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb
edging shall be measured for payment). (Precast C.C. kerb stone shall be approved
by Engineer-in-charge).
ALUMINIUM WORK:
21.10 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with
required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium
snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per
architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash
fasteners to be paid for separately) :
21.10 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) Kg 3422.40 3422.40 530.90 18,16,952.16
25.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-
sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as
required and specified,comprising of an outer heat strengthened float glass 6mm thick, of
approved colour and shade with reflective soft coating on surface # 2 of approved colour and
shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide,
dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all sqm 680.49 680.49 3,718.70 25,30,524.78
complete for the required performances, as per the Architectural drawings, as per the
approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs
shall be assembled in the factory/ workshop of the glass processor.
21.8 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing
weather silicon sealant over backer rod of approved quality as per architectural drawings and
direction of Engineer-in-charge complete.
21.8.1 Upto 5 mm depth and 5 mm width metre 3323.52 3323.52 96.75 3,21,550.56
21.15 Providing and fixing aluminium casement windows fastener of required length for aluminium
windows with necessary screws etc. complete.
21.15.1 Anodized (AC 15) aluminium each 616.00 616.00 89.40 55,070.40
WATER PROOFING:
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed
portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound
conforming to IS 2645 in recommended proportions including rounding off junction of vertical
and horizontal surface.
11 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water
proofing compound in recommended proportion including rounding off junction of vertical and
horizontal surface.
(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be
100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
22.14.1 Grading roof for water proofing treatment, cement concrete 1:2:4 with 20mm nominal size cum 248.85 248.85 8,042.30 20,01,326.36
Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three
layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l
Type ll), having one side decorative lamination and other side balancing lamination, including
IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright
finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge
Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with
one side decorative lamination other side balancing lamination Grade-I (exterior grade) in
shelves with screws and fittings wherever required, edges to be sealed with PVC edge
bending tape 2.00 mm thick of approved brand (fittings to be paid separately).
Pre-laminated with decorative lamination one side and other side balancing lamination exterior
Grade - I MDF Board 18 mm thick confirming to IS:14587
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters,
including fixing with necessary screws etc. complete.
9.114.1 Double strip (horizontal type) Each 172.80 172.80 39.70 6,860.16
TOTAL OF SCHEDULE ITEM 26,46,44,667.49
NON-SCHEDULE ITEM
MR-3 Providing and applying surface Stone textured finish with 100% natural granite & ceramic
protection coating of approved shade or approved equivalent make) comprising of water-
borne, penetrating, water repellent EM- primer & super durable water based acrylic silicon
resin clear and super durable dirt and dust resistant protection coat of FSI Clear coat, which
shall be highly water repellant, Anti-algae & anti-fungal in nature to external wall surfaces. The
coating shall also cover hairline cracks with application method which includes one coat of El
primer, one coat of Stoney, all in approved colour and texture. It shall also include preparation sqm 5297.60 5297.60 2,762.31 1,46,33,613.46
of surface, appropriate primer coat etc. applied as per manufacturer's & project consultant
instructions. Scaffolding and staging shall be allowed as required. The finish shall be in
natural colour/ non pigmented, water repellant, resistant to ultra violet, alkali and condensate
formation . All hairline cracks/ crazing shall be covered & shall ensure good breathability for
the substrate. Finished work would be to the satisfaction of the Engineer in charge.
12 Digitally signed by JAYA
DSR 2023 DESCRIPTION Unit Qty-Block (A) Qty Rounded Rate DSR Amount
MR-4 Providing & fixing of aluminium louvers of approved make, of size 79x30.6x1.7 mm having
powder coated aluminium (minimum thickness of powder coating 50 micron) of approved
make conforming to IS: 733 and IS: 1285, fixing over required alumininium tubular frame of
size 63.5x38.1x1.5 mm and with glazing flat size 62x3.9x1.50 (19384) in the existing openings
of shaft with dash fasteners of required dia and size, including necessary filling up the gaps at sqm 283.80 283.80 11,717.00 33,25,284.60
junctions, Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and
the directions of Engineer-in-charge.
MR-5 Providing and fixing of clay tiles of size-225+-5x70+-5 mm on the plastered surface using tile
adhesive and filling the gap with mortar at all heights and making any pattern as per 3D sqm 3405.60 3405.60 3,966.00 1,35,06,609.60
design or approval from the client.
TOTAL OF NON-SCHEDULE ITEM 3,14,65,507.66
13 Digitally signed by JAYA
S. No DESCRIPTIOON
1) SUB-HEAD 1.0 - SANITARY INSTALLATIONS 7,98,858.65 2,65,990.00
2) SUB-HEAD 2.0 - DRAINAGE INSTALLATIONS 3,20,458.40 7,95,181.00
3) SUB-HEAD 3.0 - WATER SUPPLY INSTALLATIONS 9,27,958.50 19,85,818.20
4) SUB-HEAD 4.0 - EXTERNAL SEWERAGE & DRAINAGE INSTALLATIONS 1,20,245.25 -
5) SUB-HEAD 5.0 - HYDRO PNEUMATIC PUMPING SYSTEM 1,25,901.00
SUB TOTAL FOR 1 BLOCK 53,40,411.00
GRAND TOTAL FOR 3 BLOCKS 1,60,21,233.00
GRAND TOTAL FOR 3 BLOCKS 1,60,21,233.00
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
SUBHEAD-I: SANITARY INSTALLATIONS
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with
100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including
17.1 cutting and making good the walls andlevel white P.V.C. flushing cistern,
1.1 including flush pipe, with manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and floors wherever required :
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests
Providing and fixing white vitreous china extended wall mounting water
closet of size 780x370x690 mm of approved shape including providing &
1.2 17.78 fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 Each 36 14999 539969.40
litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern
fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor
operated urinal of approx. size 610 x 390 x 370 mm having pre & post
1.3 17.80 flushing with water (250 ml & 500 ml consumption), having water inlet from Each 0 7979
back side, including fixing to wall with suitable brackets all as per
manufacturers specification and direction of Engineer-in-charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar
17.7 taps, 32 mm C.P. brass waste of standard pattern, including painting of
1.4 fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630 x 450mm with a pair of 15mm
CP brass pillar taps.
17.7 A Provinding and fixing wash basin wih C.I brackets, 15 mm dia CP Brass
single hole basin mixer of approved quality and make, including painting of
1.5 fittings and brackets, cutting and making good the walls whereever required :
(a) White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass
single hole basin mixer
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS :
13983 with C.I. brackets and stainless steel plug 40 mm,including painting of
fittings and brackets, cutting and making good the walls
wherever required :
17.10.1 Kitchen sink with drain board
17.10.1.1 510x1040 mm bowl depth 250mm Each 0 6946
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
17.10.2 Kitchen sink withought drain board
17.10.2.2 610x 460mm bowl depth 200mm Each 0 3874
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1
17.16A metre long with S.S. triangular plate to Eureopean type W.C. of quality and Each 37 349.15 12918.55
make as approved by Engineer - in charge.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of
1.10 17.31 approved quality) complete with 6 mm thick hard board ground fixed to Each 12 1,607.95 19295.40
wooden cleats with C.P. brass screws and washers complete.
17.34 Providing and fixing toilet paper holder :
Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality &
make and as per the direction of Engineer-in-charge..
Providing and fixing PTMT towel rail complete with brackets fixed to
1.14 17.73 wooden cleats with CP brass screws wirh concealed fittings arrangement of
approved qality and colour.
600 mm long towel rail with total length of 645 mm, w mm and effective
height of 88 mm, weighing not less than 190 gms.
18.21 Providing and fixing uplasticised PVC connection pipe with brass unions :
18.21.2 45 cm length
18.21.2.1 15 mm nominal bore Each 98 85.00 8330.00
Providing and fixing C.P. brass bib cock of approved quality conforming to
15 mm nominal bore Each 12 506.80 6081.60
Providing and fixing C.P. brass long body bib cock of approved quality
1.17 conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore Each 36 798.95 28762.20
Providing and fixing C.P. brass angle valve for basin mixer and geyser
1.18 points of approved quality conforming to IS:8931 a) 15 mm nominal bore
18.53.1 15 mm nominal bore Each 98 574.30 56281.40
Providing and fixing PTMT soap Dish Holder having length of
1.20 18.65 138mm,breadth 102mm, height of 75mm with concealed fitting Each 36 111.45 4012.20
arrangements,weighing not less than 106 gms.
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
Providing and fixing 8mm thick beveled edge glass mirror with side
polished complete including fixing over marine plywood frame work with
silicon at all levels & height including fixing of molded ,screw and silicon etc.
incl labors, tools, scaffolding at all heights as per Direction of EIC
Providibng and fixing straight type Macfit single body push fit type WC pan
connector with factory supplied spring loaded seal guard of McAlpine, UK
with integral single mould sealing fins made of flexible EVA body, including
bush/adaptor for use with C.I. Pipe as supplied with the pan connector.
Providing and Fixing Handicapped set including white vitreous china floor
mounted European type water closet including dual flush exposed cistern
(4/2 lpf) , Flat Back wash basin with one pair of mounting brackets ,
complete with fittings, seat cover, two no hinged rail 76 cms and five nos of
grab bar 60 cms including 15 mm dia autoclosing pillar cock flow less than
3.0 lpm for Handicaped Toilet complete in all respest as per direction of the
engineer-in-charge.
For physically handicap person consisting of;
a) Wall mounted WC Pan-01 no. with built in Jet of
b) Concealed Cistern Cistern-01 no.
c) Soft Close Seat Cover -01 no
d) Wall hung Wash Basin -01 no
e) Spatula Single lever
f) Wall mounted Grab bar 600 mm long - 2 nos
g) Wall mounted Hinged hand rail 750 x 100-01 no
h) Bottle Trap
i) Waste Coupling
j) Stainless soap dish
k) Tissue paper holder
Providing,Fixing satin finish stainless steel AISI 316 grade wall mounted coat
hook on door complete.
18.22.2 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : Each 36 222 8004.60
Providing , Fixing , testing and commissioning of CP Brass concealed
divertor with provision of overhead shower with 115mm long bend pipe, in
built spout, spout/shower selector with wall flange complete with all
accessories as required and making good the walls wherever required.
TOTAL FOR SUB HEAD - I CARRIED TO SUMMARY OF PRICES 7,98,858.65 2,65,990.00
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
SUBHEAD-II: DRAINAGE INSTALLATIONS
Providing, fixing, jointing and testing in position of ISI marked UV stabilized
uPVC pipes for soil, waste as per IS : 13592 (Type-B) suitable for rubber
ring joints for vertical pipes and solvent cement joints for horizontal pipes,
including all neccessary specials and fittings (confirming to IS : 14735) i.e.
2.1 bends, tees, junctions (with or without doors), reducers, couplers, cowels,
clamps, hangers, rubber rings, clean outs (door piece), fixing at wall / ceiling
/ floor level supported by clamp & hangers, MS angle etc.(duly painted and
approved by Project Incharge) inside duct/ shaft / suspended from floor
under false ceiling for proper completion of the work. The rubber ring shall
confirm to IS : 5382.
For Soil and Waste pipe
Providing, fixing, jointing and testing in position of ISI marked UV stabilized
uPVC SWR pipe for vent as per IS : 13592 (Type-A) suitable for rubber ring
joints for vertical pipes and solvent cement joints for horizontal pipes,
including all neccessary specials and fittings (confirming to IS : 14735) i.e.
bends, tees, junctions (with or without doors), reducers, couplers, cowels,
clamps, hangers, rubber rings, clean outs (door piece), fixing at wall / ceiling
/ floor level supported by clamp & hangers, MS angle etc.(duly painted and
approved by Project Incharge) inside duct / shaft / suspended from floor
under false ceiling for proper completion of the work. The rubber ring shall
confirm to IS : 5382.
75 mm OD (Vertical ) Metre 58 515 29870.00
Providing, fixing & testing uPVC pipes, conforming to IS : 4985 class III (6.0
2.3 NSI Kg/cm ) including injection moulded fittings IS : 7834, jointing with solvent
cement, cutting and making good the floors and walls and jointing to
trap/waste pipe, complete of outer dia.
Providing and fixing in position uPVC full bore 'P' / 'S' trap with 50 mm
2.4 NSI water seal (IS : 14735) of the following sizes. Making proper connection with
solvent cement.
Providing, fixing and testing & commissioning of uPVC SWR inlet fittings
2.5 NSI with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 Each 69 631 43539.00
mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint
complete in all respect.
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
Supply, installation, testing & commissioning of uPVC floor drain with
2.6 NSI supporting clamp ceiling or in sunken portion including cutting and making
good the walls and floors wherever required complete in all respects.
90mm X 63mm for FD Each 55 684 37620.00
Supply, installation, testing & commissioning of uPVC Balcony drain with
2.7 NSI supporting clamp ceiling or in sunken portion including cutting and making
good the walls and floors wherever required complete in all respects.
110mm X 63mm for BD Each 83 713 59179.00
Providing and fixing 1 mm thick Stainless steel (SS-304) Grating with frame
2.8 NSI for floor traps or drains of required pattern including cutting and making
good the floors complete.
125mm X 125mm square grating without hole (Toilet) Each 207 244 50508.00
Providing and laying Cement Concrete 1 : 2 : 4 mix (1 cement : 2 coarse
2.9 sand : 4 graded stone aggregate 20 mm nominal size) 50 mm in bed and
alround uPVC soil & waste pipes including excavation, refilling wherever
required complete in all respects as per standard design.
For Pipe 40mm OD to 75 mm OD Metre 124 200 24800.00
Providing and fixing Upvc Cleanout Plug with suitable inlet keys for
2.10 NSI opening, male threaded joint with socket to upvc soil or waste pipe as
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring conforming
to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.1 Coupler
12.42.2 Single Push Fit Coupler
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
12.42.3 Single tee with door
12.42.5 Plain bend 87.5 deg
12.42.6 Shoe (Plain)
Providing and fixing unplasticised -PVC pipe clips of approved design to
unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood
2.13 12.43 plugs, screwed with M.S. screws of required length, including cutting brick
work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making
good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15
cm diameter and weighing not less than 440 grams.
TOTAL FOR SUB HEAD - II CARRIED TO SUMMARY OF PRICES 3,20,458.40 7,95,181.00
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
SUBHEAD-III: WATER SUPPLY INSTALLATIONS
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having
thermal stability for hot & cold water supply including all CPVC plain & brass
threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step CPVC solvent cement and
3.2 18.8 the cost of cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge. (Concealed work
including cutting chases and making good the walls etc.,)
concealed work including cutting chases and making good the wall etc.
18.8.1 15 mm nominal outer dia pipes Metre 624 497.80 310627
3.2.1 18.8.2 20 mm nominal outer dia pipes Metre 312 537.60 167731
18.8.3 25 mm nominal outer dia pipes Metre 44 627.25 27599
18.8.4 32 mm nominal outer dia pipes Metre 42 739.30 31051
Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting
and making good the walls etc.
Internal work - Exposed on Wall
18.10.3 25 mm nominal bore Metre 12 551.70 6620
18.10.4 32 mm nominal bore Metre 24 667.00 16008
18.10.5 40 mm nominal bore Metre 36 811.90 29228
18.10.6 50 mm nominal bore Metre 22 1048.35 23064
NSI 65 mm nominal bore Metre 18 1178 21,204.00
NSI 80 mm nominal bore Metre 580 1550 8,99,000.00
Providing and fixing Stainless Steel pipe and fitting of grade 316L as per IS :
6911:2017 and conforming to EN-10312 standards complete with press type
fitting (fitting shall be paid for separately) including fixing of the pipe with
3.4 18.85A clamps at 1.00 m spacing including cutting and making good the walls
including testing of joints complete as per direction of Engineer-in-charge.
(The pipe length inserted in the fitting shall not be measured for payment)
Internal work - Exposed on wall (For Hot water from solar)
22 mm outer dia Pipe Metre 1025.25
28 mm outer dia Pipe Metre 8 1272.15 10177
35 mm outer dia Pipe Metre 16 1765.10 28242
42 mm outer dia Pipe Metre 24 2124.00 50976
54 mm outer dia Pipe Metre 10 2699.10 26991
NSI 76 mm outer dia Pipe Metre 202 3101 6,26,422.20
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
Providing stainless steel pipes conforming to JIS 3448 standard complete
with press type fittings for Hot and cold water supply, RO & domestic water
supply system capable to withstand temperature upto 1100 centigrade and
pressure upto 16 bars made from 316 grade of annealed and pickled
stainless steel sheet, with ends deburred at 900 and with length of 3 meters.
Pipe qualifying to 100% eddy current, 100% hydrostatic tested and air-under
water tested under 10kgs. Fittings also conforming to JIS standard in 316
stainless steel grade of approved make in accordance with DVGW
regulation such as tees, coupling, elbow, male adapter, connectors etc with
Black grooved O-ring of EPDM material which can withstand temperature
upto -200 to 1100 C including suitable connection as per site requirement.
Direct contact of stainless steel pipes and fittings to galvanized iron should
be avoided by inserting approved type of filler material as per project
manager ’ s/consultant requirement. Flanges, clamps with hanger at a
spacing of 2 m centre to centre min or as required etc. necessary adapters
for pipes, jointing, sundries, cutting holes in walls/floors/slabs & making good
complete. .(From shaft to internal toilet-geyser)
28 mm dia Metre 1565
Providing and fixing required Stainless Steel Fitting of press fit design of
grade 316L as per IS : 6911:2017 and conforming to EN-10312 standards
with V-profile and with O-ring sealing gasket of EPDM material of required
dia as per direction of Engineer-in-charge.
18.90A.5 For 42mm outer dia pipe Each 4 2418.50 9674
18.90A.6 For 54mm outer dia pipe Each 4 3200.95 12804
Providing and fixing required Stainless Steel Fitting of press fit design of
grade 316L as per IS : 6911:2017 and conforming to EN-10312 standards
with V-profile and with O-ring sealing gasket of EPDM material of required
dia as per direction of Engineer-in-charge.
18.93A.3 For 28 mm x 22 mm outer dia pipe Each 2 1138.10 2276
18.93A.5 For 35 mm x 22 mm outer dia pipe Each 4 1436.85 5747
18.93A.6 For 35 mm x 28 mm outer dia pipe Each 2 1451.10 2902
18.93A.7 For 42 mm x 22 mm outer dia pipe Each 2 2013.05 4026
18.93A.8 For 42 mm x 28 mm outer dia pipe Each 6 2034.35 12206
Making connection of G.I. distribution branch with G.I. main of following
3.11 18.1 sizes by providing and fixing tee, including cutting and threading the pipe
etc. complete :
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
18.13.1 25 to 40 mm nominal bore Each 20 911.90 18238
18.13.2 50 to 80 mm nominal bore Each 40 1785.35 71414
Providing and fixing of gun metal gate valve with CI wheel of approved
quality (screwed ends):
3.12 18.17.1 A 20 mm dia, nominal bore Each 12 539.95 6479
18.17.1 25 mm dia, nominal bore Each 12 622.40 7469
18.17.2 32 mm dia, nominal bore Each 12 689.60 8275
Painting G.I. pipes and fittings with synthetic enamel white paint with two
3.13 18.38 coats over a ready mixed priming coat, both of approved quality for new work
18.38.3 25mm diameter pipe Metre 12 30.25 363
18.38.4 32mm diameter pipe Metre 24 36.35 872
18.38.5 40mm diameter pipe Metre 36 42.65 1535
18.38.6 50mm diameter pipe Metre 22 51.00 1122
NSI 65 mm nominal bore Metre 18 59 1,062.00
NSI 80 mm nominal bore Metre 580 75 43,500.00
Providing and fixing insulation with thermaflex elastomeric nitrile rubber
sheets complete with plastering of 20 mm thick insulation with thermaflex
elastomeric nitrile rubber sheets for hot water & cold water pipes exposed to
sun complete with Aluminium
c) 25mm (9 mm thickness) Meter 6 368 2,208.00
d) 32mm (9 mm thickness) Meter 12 403 4,836.00
e) 40mm (9 mm thickness) Meter 28 450 12,600.00
h) 80mm (9 mm thickness) Meter 212 722 1,53,064.00
Providing and fixing C.P. brass stop cock (concealed) of standard design
3.15 and of approved make conforming to IS:8931.
18.52.1 15 mm dia nominal bore Each 8 670.45 5364
Provide and fixing PTMT ball cock of approved quality, colour and make
3.16 complete with epoxy coated aluminium rod with L.P/H.P.H.D. plastic ball
18.62.5 50 mm dia NB, 242mm long. Weighing not less than 1240 gms. Each 8 1375.95 11008
Providing & fixing in position precast RCC manhole cover and frame of reqd.
3.17 shape and approved quality.
19.19.4.1 Circular shape 560 internal dia. Each 3 2123.80 6371
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
Providing and fixing C.I. double acting air valve of approved quality with
3.18 18.59 bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if
required will be paid separately) :
Providing and fixing M.S fabricated hot dipped galvanized coating puddle
flange comprising of 600 mm dia long M.S class 'B' pipe (screwed end up to
50 mm & flange for more than 50 mm dia) with 6 mm thick M.S plates of
required size including cutting holes in centre of plate, inserting pipe &
3.19 NSI making welded (Arc) joint complete. Same shall be installed with TEC
welded joint in position with reinforcement bars of RCC tank wall/slab
including making cutout in shuttering during concrete casting of tank of
following diameter. (Location: overhead tanks.)
NSI 25mm dia pipe, 600mm long with size of 250x250x6 mm MS plate Each 6 782 4,692.00
NSI 50mm dia pipe, 600mm long with size of 350x350x6 mm MS plate Each 7 1180 8,260.00
NSI 65mm dia pipe, 600mm long with size of 350x350x6 mm MS plate Each 2 2183 4,366.00
NSI 80mm dia pipe, 600mm long with size of 400x400x6 mm MS plate Each 4 2662 10,648.00
NSI 100mm dia pipe, 600mm long with size of 400x400x6 mm MS plate Each 2 3067 6,134.00
NSI 150mm dia pipe, 600mm long with size of 450x450x6 mm MS plate Each 3 3624 10,872.00
Providing and fixing motorised butterfly valve with Control Panel & Float
Type Magnetic Level Sensors suitable for 220-230 volts AC to operate valve
3.20 NSI when water level is low in tanks and to close when water level is high in
water tanks including necessary cables, conduits, upto junction box (upto 6
mt qty approx.) etc., complete.
TOTAL FOR SUB HEAD - III CARRIED TO SUMMARY OF PRICES 9,27,958.50 19,85,818.20
SUBHEAD-V: EXTERNAL SEWERAGE & DRAINAGE INSTALLATIONS
Excavating trenches of required width for pipe, cables etc including
excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto
1.5m including getting out the excavated soil,& then returning the soil as
required, in layers not exceeding 20 cm in depth including consolidating each
5.1 deposited layer by ramming ,watering, etc and disposing of surplus
excavated soil as directed, within lead of 50m.
All kinds of soil
2.10.1.2 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia metre 45 352.15 15847
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light
duty) 455 x 610mm internal dimensiions total weight of cover and frame to
be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.),
with FPS bricks with class designation 7.5
Inside size 120 x 90 cm and 90 cm deep including CI cover with frame
(heavy duty) 500mm internal dia. Total weight of cover and frame to be not
less than 116 Kg. ( weight of cover to be 58 Kg. and weight of frame 58
Kg.)with FPS bricks class designation 75. (Sewerage Line)
Providing orange colour safety foot rest of minimum 6 mm thick plastic
encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS:
1786 having minimum cross section as 23 mm x 25 mm and over all
minimum length 263 mm and width as 165 mm with minimum 112 mm
space between protruded legs having 2 mm tread on top surface by ribbing
or chequering besides necessary and adequate anchoring projections on tail
5.11 19.16 length on 138 mm as per standard drawing and suitable to with stand the Each 4 553.70 2215
bend test and chemical resistance test as per specification and having
manufacture's permanent identification mark to be visible even after fixing,
including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (
1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal
size) complete as per design.
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in
19.27 cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-
5.12 cast R.C.C. horizontal grating with frame complete as per standard design :
19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 4 5957.90 23832
TOTAL FOR SUB HEAD - V CARRIED TO SUMMARY OF PRICES 1,20,245.25 -
SUBHEAD-VII: HYDRO PNEUMATIC PUMPING SYSTEM
7.1 NSI Supply, Installation, Testing and Commissioning of compact packaged type
skid mounted, self contained variable frequency drive hydro pneumatic
system complete as per the technical specification complete as required:-
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
(i) In- line vertical multistage centrifugal water pump set (for clear water) with
SS-304 casing, SS-304 impeller with SS-316 shaft ,CI base with coating
complete directly coupled with TEFC induction motor of class "F" insulation &
efficiency class IE-3, 2900rpm, suitable for operation on 415 Volts ±10%, 3
phase, 50 Hz A.C. supply. The entire system shall be mounted on a common
base frame i/c common suction and common delivery of G.I heavy class
pipe headers with flanges, interconnecting piping with all required Control
Valves, Non-return valves, pressure gauge with isolation cock etc. complete
(ii) Pressure vessel of non corrosive FRP composite construction lined with
NSF and/or FDA listed material, like high density polyethylene with fully
replaceable polyurethane. Air cell burst pressure of minimum of 3 times the
vessel operating pressure and prototype cycle tested for 80,000 cycles with
charging connections to discharge pipe line with necessary flanges, gaskets,
isolating valve, nuts/ bolts etc. with suitable foundation bolts etc complete as
(iii) Microprocessor based multi pump contoller/panel with graphical display
and variable frequency drive (VFD) mounted inside a panel complete with
pressure sensor transmitter. The graphical display capable to show number
of pumps running & also communicate with other controllers following with
open protocol through RS485 port. System should be capable to
compensate for frictional losses at lower flows. All alarms should be
displayed in the controller. The panel should also have provision for manual /
automatic alternate (cyclic) operation of pumps, ON/OFF switch complete as
(v) Necessary foundationing bolts, vibration elimination pads etc complete as
Domestic Water booster Pumps at Terrace
Set of Two Pumps( 1 Working+ 1 Standby)
Capacity 200 LPM (Indicative)
7.2 NSI Providing and fixing cast iron butterfly valves conforming
to IS:13095, PN 16/20 complete with bolts,nuts, 3mm thick
compressed asbestos gasket, and two matching flanges as per
table E complete.
Digitally signed by JAYA
S.NO DSR-2023 / NSR DESCRIPTION UNIT GIRLS Rate Amount
HOSTEL- DSR NSR DSR NSR
7.3 NSI Providing and fixing dual plate wafer type C.I. non-return
valve conforming to IS: 5312 rated to PN 16. with bolts, nuts,
3mm thick gasket and matching flanges as per table 'E'
TOTAL FOR SUB HEAD - VI CARRIED TO SUMMARY OF PRICES 1,25,901.00
Digitally signed by JAYA
FIRE FIGHTING WORK
S. No DESCRIPTIOON
FIRE FIGHTING WORKS
1) SUB-HEAD 1.0 - FIRE PUMPS 2,15,488.00 -
2) SUB-HEAD 2.0 - CONTROL PANELS 35,883.00 2,11,236.00
3) SUB-HEAD 3.0 - PIPES & ACCESSORIES 14,34,941.00 6,13,560.00
4) SUB-HEAD 4.0 - FIRE EXTINGUISHERS - 3,21,744.00
SUB TOTAL FOR 1 BLOCK 28,32,852.00
GRAND TOTAL FOR 3 BLOCKS 84,98,556.00
GRAND TOTAL FOR 3 BLOCKS 84,98,556.00
FIRE FIGHTING WORK
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
Supplying, installation, testing and commissioning of electric driven terrace pump
1 27.4 conforming to IS 12469: 2019 suitable for automatic operation and consisting of following,
complete in all respects, as required: (Terrace Pump)
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical seal as required.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts,
3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot
mounted type with Class 'F' insulation, conforming to IS-12615: 2018.
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as
Suitable cement concrete foundation duly plastered and with anti vibration pads.
TOTAL FOR SUB HEAD - I CARRIED TO SUMMARY OF PRICES 2,15,488.00 -
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
SUBHEAD-II: CONTROL PANELS
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of
cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet,
compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of
approved shade after 7 tank treatment process, cable alley, interconnection with suitable
size copper conductor cable/solid copper strip, having switchgears and accessories,
mountings and internal wiring, earth terminals, numbering etc. complete in all respect,
suitable for main fire pump, pressurisation pump & diesel pump set complete as per
CPWD specification with following in coming and Outgoings, suitable for operation on
415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
630A, 50kA 4 Pole MCCB, Ics=100% Icu rating
Digital Voltmeter 0-500V with selector switch
Ammeter (0-630 A) with selector swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps
Set of Copper Bus Bar 500A
( Note : All outgoing feeders for pumps should have digital Ammeter with selector
switches, and LED type ON, OFF, trip indicating lamps)
200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for
95 hp pump with overload protection, current sensing type single phase preventor
complete with all acceessories and internal wiring required for automatic operation,
selector switch for local/remote, auto/manual/OFF operation. 2 Set
100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta
starter with overload protection, current sensing type single phase preventor complete
with all acceessories and internal wiring required for automatic operation, selector switch
for local/remote, auto/manual/OFF operation. 2 Set
Diesel Engine Control
Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempt
starting device, timers and relays as required, push buttons,start/stop in manual mode
Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on
indicationBattery charger suitbale for 12V/24 V DC with boost and trickle selector switch,
0-30 V DC volt meter, and 0-20 A DC Ammeter
All standard relays and accessories for automatic operation of diesel engine System
Controller Designing, Supply, Installation, Testing and commissioning of system controller
to control operation of main electric fire pump, diesel pump, Pressurization pump,
Terrace pump in sequence as per specification consisting of relays, timers. Sensors,
annunciation window for fault indication, complete as per specifications.
System Controller
Designing, supply, installation, testing & commissioning of system controller to control
operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in
sequence as per specification consisting of relays, timers. Sensors, annunciation window
for fault indication, complete as per specification.
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
3 NSR-1 Pressurisation Pump and Terrace Pump Control Panel Set 1 1,86,322.00 1,86,322.00
(a) 63 Amps. TP & N SFC with HRC fuses
(b) Voltmeter (0-500 Volt) with selector switch.
(c) Ammeter (0-63 Amps.) with selector switch & CTs.
(d) Set of 3 phase indication lamp
Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing
(e) type single phase preventor complete with all accessories and internal wiring required for
automatic operation.
(f) Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc.
Supplying and making end termination with brass compression gland and aluminium lugs
DSR 2018 / for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable
9.1 of 1.1 kV grade as required. It should be complete as per specifications & directions of
Engineer-in-charge.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering
pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode
5.11 including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as Meter 35 583.00 20,405.00
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc.
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor
armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date
5 NSR ammendment of following size in the existing RCC/HUME/ METAL /GI /CI
/Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred.
5.1 NSR-3 4 core, 25 sq.mm. Aluminium Armoured Meter 15 303.00 4,545.00
5.2 NSR-4 3.5 core, 50 sq.mm. Aluminium Armoured Meter 25 419.00 10,475.00
5.3 NSR-5 3 core, 10 sq.mm. Aluminium Armoured Meter 20 207.00 4,140.00
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers
Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat
shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 :
2006. It should be complete as per specifications & directions of Engineer-in-charge.
TOTAL FOR SUB HEAD - II CARRIED TO SUMMARY OF PRICES 35,883.00 2,11,236.00
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
SUBHEAD-III: PIPES & ACCESSORIES
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to
IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts,
gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and
painting with two or more coats of synthetic enamel paint of required shade complete as
required. (Plant Room piping/Vertical Riser/Downcomer/Floor)
Supplying and fixing single headed internal hydrant valve with instantaneous
Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked
conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as
27.9.2 Single headed Stainless steel Set 14 6,632.00 92,848.00
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with
9 27.11 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required :
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
Providing, installation, testing and commissioning of non-return valve of following sizes
10 27.14 confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated
11 27.15 out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and
12 27.16 female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as
27.16.2 Stainless Steel (Grade 304) Set 28 4,667.00 1,30,676.00
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office
red, conforming to IS 884 complete with the following as required.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm
dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal
14 27.18 diameter size nozzle conforming to IS 903 suitable for instantaneous connection to
interconnect hose pipe coupling as required :
27.18.2 Stainless Steel (Grade 304) Set 14 3,402.00 47,628.00
Supplying and fixing of fire brigade connection of cast iron body with gun metal male
15 27.19 instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS
pipe connection conforming to IS 904 as required :
27.19.2 4 way - 150 mm dia M.S. Pipe. Set 14,820.00
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in
height with air release valve on top and flanged connection to riser, drain arrangement
with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and
paintingwith synthetic enamel paint of approved shade as required.
31 27.22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as Each 2 1,670.00 3,340.00
DSR 2018 / Providing and fixing in position the industrial type pressure gauges with gun metal /
16.8 brass valves complete as required
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
Providing and fixing standard fireman's axe with heavy insulated rubber handle
conforming to IS: 926 complete.
Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of
accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2 & 1 No. Dry
podwer type portable fire extinguishers & accessories. The door shall have a front glass
with lock and key arrangement & shall be painted with one coat of primer & two coat of
34 NSR-10 finished stove enamelled post office red colour paint & "FIRE HOSE" written on front. Each 14 34,577.00 4,84,078.00
(Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE )
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration
eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11
Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges.
NSR-14 80 mm dia Nos. 17,168.00
NSR-15 65 mm dia Nos. 15,108.00
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated
ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting &
gland of superior quality having minimum working pressure of 16 kg/sqcm.
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
S.NO. DSR-2025 / DESCRIPTION UNIT Rate Amount
NSR Girls hostel- DSR NSR DSR NSR
TOTAL FOR SUB HEAD - III CARRIED TO SUMMARY OF PRICES 14,34,941.00 6,13,560.00
SUBHEAD-IV: FIRE EXTINGUISHERS
Providing, storing, handling, shifting, installation, testing and commissioning of halon free
portable fire Extinguishers as described below:
Concealed work, including cutting chases and making good the walls etc.
Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of
welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure
37.1 NSR-19 indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, Nos. 20 10,651.00 2,13,020.00
discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re
enamel paint and fixed to wall with brackets complete with internal charge.
Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded
M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating
37.2 NSR-20 guase internal discharge tube 30 cms long high pressure discharge hose, discharge Nos. 14 5,989.00 83,846.00
nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel
paint and fixed to wall with brackets complete with inernal charge.
Water CO2 type of 9 lit.Fire Extinguisher with Gun metal cap and nozzlecomplete in all
respects including wall suspension bracket and conforming to IS: 15683.
Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical
Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted
NSR-22 with pressure indicating gauge, internal tube, squeeze lever type valve fully charged Nos. 1 16,671.00 16,671.00
complete in all respects including wall suspension bracket / trolley mounted and
37.4 confoming to IS:910 .
Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire
extinguisher ISI marked under IS:15683 complete with imported Novec 1230
38 NSR-24 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Nos. 1 8,027.00 8,027.00
Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium
sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV Square
stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with Inch
proper clamps, hangers, cleats, anchor fasteners etc.
TOTAL FOR SUB HEAD - IV CARRIED TO SUMMARY OF PRICES - 3,21,744.00
Digitally signed by JAYA
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 PRAKASH GURU
ELECTRICAL SUMMARY
SR. NO. DESCRIPTION AREA (SQM)
SOR/ BSR/DSR ITEMS SOR/DSR) REMARK
D INTERNAL ELECTRIFICATION DSR NSR
S.H.-I INTERNAL ELECTRIFICATION 75,64,753.00 -
S.H.-II DISTRIBUTION BOARD 8,21,318.00 10,64,050.00
S.H.-III LIGHT FIXTURES & FANS 12,11,330.00 5,30,091.00
EATHING & LIGHTNING
CABLE, CABLE TRAY &
S.H.-VII UPS SYSTEM 1,09,793.00 -
S.H.-VIII TV & TELEPHONE SYSTEM - 5,953.00
FIRE ALARM SYSTEM
S.H.-IX (ADDRESSABLE TYPE) & PA 8,18,106.00 1,42,945.00
S. H. X LIFT SYSTEM - 43,10,000.00
DATA, WI-FI (PASSIVE
S. H. XIII IP BASED CCTV SYSTEM 5,63,618.00 28,475.00
GRAND TOTAL FOR 1 BLOCK
GRAND TOTAL FOR 1 BLOCK
GRAND TOTAL FOR 3 BLOCK
GRAND TOTAL FOR 3 BLOCK
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
S.H.-I INTERNAL ELECTRIFICATION
1.0 DSR-2025 - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
1.10 FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed
medium class PVC conduit, with modular switch, modular plate, suitable GI box and
earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor
single core cable etc. as required.
2.0 DSR-2025 - Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper
1.11 conductor single core cable in surface / recessed medium class PVC conduit, 2way
modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm
FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
3.0 DSR-2025- Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
1.54 point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper
conductor single core cable in surface/ recessed steel conduit, and earthing the
point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc.
4.0 DSR-2025- Supplying and fixing suitable size GI box with modular plate and cover in front on
1.31 surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet
and 5/6 A modular switch, connections etc. as required. 135 135 Each 545 73 575
5.0 DSR-2025 - Supplying and fixing suitable size GI box with modular plate and cover in front on
1.56 surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket
outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs
to be used in non residential buildings). 85 85 Each 757 64 345
6.0 DSR-2025 - Supplying and fixing suitable size GI box with modular plate and cover in front on
1.32 surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular
socket outlet and 15/16 A modular switch, connections etc. as required 98 98 Each 659 64 582
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
7.0 DSR-2025 - Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and
2.18 earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel
enclosure, on surface or in recess, with chained metal cover for the socket out let
and complete with connections, testing and commissioning etc. as required
8.0 DSR-2025 - Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper
1.12 conductor single core cable in surface/ recessed medium class PVC conduit along
with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable
for loop earthing as required. 2450 2450 Metre 373 9 13 850
9.0 DSR-2025 - Wiring for light/ power plug plug with 4 X 4 sq. mm FR PVC insulated copper
1.13 conductor single core cable in surface / recessed medium class PVC conduit along
with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop
earthing as required. 1825 1825 Metre 857 15 64 025
10.0 DSR-2025 - Wiring for circuit/ submain wiring along with earth wire with the following sizes of
1.14 FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed
medium class PVC conduit as required.
10.2 1.14.2 2x2.5 sq mm + 1x2.5 sq mm earth wire 0 0 Metre 311
10.3 1.14.3 2x6 sq mm + 1x6 sq mm earth wire 240 240 Metre 482 1 15 680
10.4 1.14.4 2x10 sq mm + 1x10 sq mm earth wire 50 50 Metre 621 31 050
10.5 1.14.5 2x16 sq mm + 1x16 sq mm earth wire 25 25 Metre 832 20 800
10.7 1.14.7 4x6 sq mm + 2x6 sq mm earth wire 350 350 Metre 813 2 84 550
11.0 DSR-2025- Wiring for circuit/ submain wiring along with earth wire with the following sizes of
1.7 FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed
steel conduit as required
CIRCUIT / SUBMAIN WIRING
11.1 1.7.7 4x2.5 sq mm + 2x2.5 sq mm earth wire 50 50 Meter 621 31 050
11.2 1.7.8 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 55 55 Meter 744 40 920
11.4 1.7.10 4x10 sq mm + 2x6 sq mm earth wire. 25 25 Meter 1 253 31 325
11.5 1.7.11 4x16 sq mm + 2x6 sq mm earth wire. 25 25 Meter 1 760 44 000
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
12.0 DSR-2025 - Supplying and fixing following modular switch/ socket on the existing modular plate &
1.24 switch box including connections but excluding modular plate etc. as required.
12.1 1.24.6 Telephone Socket Outlet 5 5 Each 168 840
12.2 1.24.7 TV anteena Socket Outlet 5 5 Each 168 840
13.0 DSR-2025 - Supplying and fixing following size/ modules, GI box along with modular base and
1.27 cover plate for modular switches in recess etc as required.
14.0 DSR-2025 - Supplying and fixing two module stepped type electronic fan regulator on the existing
1.25 modular plate switch box including connections but excluding modular plate etc. as
required. 85 85 Each 402 34 170
15.0 DSR-2025 - Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated
1.18 annealed copper conductor, unarmored telephone cable in the existing surface/
recessed steel/ PVC conduit as required.
16.0 DSR-2025 - Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper
1.19 conductor PE insulated, shielded with fine tinned copper braid and protected with
PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 150 150 Metre 54 8 100
17.0 DSR-2025 - Supplying and fixing of following sizes of PVC conduit along with the accessories in
1.21 surface/recess including painting in case of surface conduit, or cutting the wall and
making good the same in case of recessed conduit as required.
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
18.0 DSR-2025 - Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as
1.38 required. 5 5 Each 112 560
19.0 DSR-2025 - Supplying and fixing modular blanking plate on the existing modular plate & switch
1.26 box excluding modular plate as required. 80 80 Each 47 3 760
20.0 DSR-2025- Supplying and fixing of following sizes of STEEL conduit alonwith the accessories in
1.20 surface/recess including painting in case of surface conduit, or cutting the wall and
making good the same in case of recessed conduit as required.
Total Internal Electrification Carried over to Summary 75 64 753
S.H.-II DISTRIBUTION BOARD
1.0 DSR-2025 - Supplying and fixing following way single pole & neutral, sheet steel, MCB
2.3 distribution board, 240 volts, on surface/ recess, complete with tinned copper bus
bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator)
1.1 2.3.2 8 way Double Door 1 1 Each 2 773 2 773
2.0 DSR-2025 - Supplying and fixing following way, horizontal type three pole and neutral, sheet
2.4 steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned
copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator).
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
3.0 DSR-2025 - Supplying and fixing following ways, surface/ recess mounting, vertical type, 415
2.5 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder
painted, inclusive of 200 amp tinned copper bus bar, common neutral link, earth bar,
din bar, for mounting MCB's (but without MCB's and incomer) as required. (Note :
Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
3.1 2.5.3 12 way ( 4 + 36 ), Double door, Vertical type 12 12 Each 13 512 1 62 144
4.0 DSR-2025 - Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit
2.10 breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required
4.2 2.10.5 Tripole pole and neutral 2 2 Each 1 301 2 602
5.0 DSR-2025 - Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB
2.13 DB complete with connections, testing and commissioning etc. as required.
6.0 DSR-2025 - Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,
2.14 residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the
existing MCB DB complete with connections, testing and commissioning etc. as
7.0 DSR-2025 - Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
2.15 residual current circuit breaker (RCCB), having a sensitivity current upto 300
milliamperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
B DISTRIBUTION PANEL (L.T. PANEL)
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing &
commissioning of cubicle type totally enclosed free standing type moisture, dust and
vermin proof Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thick
CRCA sheet complete with following equipments including internal wiring with
suitable size wires / cable, interconnection, painting complete as per specification &
drawing. All the incomming and outgoing MCCB shall have 26 KA Ics. All the MCCB
up to 250 Amp shall have thermal release with adustable overload and short circuit
protection and above shall have microprocessor release with adjustable overload,
short circuit & earthfault protection.
8.0 NSR MAIN LT PANEL (DOUBLE OCCUPANCY GIRL'S HOSTEL) - GROUND FLOOR
1 No 400 Amp FP Moulded Case Circuit Breaker
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
1 No.400A, FP Multi fuction Energy Meter with CT's meter with RS 485 port.
500 Amp TPN aluminium bus bar.
02 No 200 Amp FP Moulded Case Circuit Breaker
01 No 160 Amp FP Moulded Case Circuit Breaker
03 No 100 Amp FP Moulded Case Circuit Breaker
02 No 63 Amp FP Moulded Case Circuit Breaker
05 Nos 63 Amp TPN Miniature Circuit Breaker
04 Nos 40 Amp TPN Miniature Circuit Breaker
05 Nos 25 Amp TPN Miniature Circuit Breaker
02 Nos 40 Amp DP Miniature Circuit Breaker
02 Nos 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
Main LT panel (Double Occupancy Girl's Hostel) described as above 1 1 Set 3 61 195 3 61 195
9.0 NON DSR EMERGENCY PANEL (DOUBLE OCCUPANCY GIRL'S HOSTEL) - GROUND
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
1 No 63 Amp FP Moulded Case Circuit Breaker
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
1 No.200A, FP Multi fuction Energy Meter with CT's meter with RS 485 port.
100 Amp TPN aluminium bus bar.
02 Nos 40 Amp DP Miniature Circuit Breaker
08 Nos 25 Amp DP Miniature Circuit Breaker
01 Nos 40 Amp FP Miniature Circuit Breaker
1 Lot of control / power wiring.
Emergency panel (Double Occupancy Girl's Hostel) described as above 1 1 Set 1 41 684 1 41 684
10.0 NSR LIFT PANEL (DOUBLE OCCUPANCY GIRL'S HOSTEL) - TERRECE FLOOR
1 No. 100 Amp FP Moulded Case Circuit Breaker.
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
1 No. 100A, FP Multi function energy meter with CT's with RS 485 port.
150 Amp TPN aluminium bus bar.
03 Nos 63A FP RCBO.
03 Nos 25A DP Miniature Circuit Breaker.
1 Lot of control / power wiring.
Lift Panel (Double Occupancy Girl's Hostel) described as above 1 1 Set 1 18 436 1 18 436
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
11.0 NSR UPS PANEL (DOUBLE OCCUPANCY GIRL'S HOSTEL) - GROUND FLOOR
1 No 40 Amp DP Miniature Circuit Breaker
1 Set of ON / OFF indicating lamps with Single Pole MCB.
1 No.40A,DP Multi fuction Energy Meter with CT's meter with RS 485 port.
100 Amp FP copper busbar.
06 No. 25 Amp DP Miniature Circuit Breaker
01 Nos 40 Amp DP Miniature Circuit Breaker.
1 Lot of control / power wiring.
UPS Panel (Double Occupancy Girl's Hostel) described as above 1 1 Set 34 922 34 922
12.0 NON DSR MDB - 1,2, 3, 4 & 5 (DOUBLE OCCUPANCY GIRL'S HOSTELL) - 1ST, 2ND, 3RD,
4TH & 5TH FLOOR
1 No 100 Amp FP Moulded Case Circuit Breaker
1 Set of phase indicating lamps with Single Pole MCB.
1 Set of ON / OFF indicating lamps with Single Pole MCB.
150 Amp TPN aluminium bus bar.
03 Nos 63 Amp FP Miniature Circuit Breaker
03 Nos 40 Amp FP Miniature Circuit Breaker
01 Nos 25 Amp FP Miniature Circuit Breaker
01 Nos 25 Amp DP Miniature Circuit Breaker
1 Lot of control / power wiring.
MDB - 1, 2,4,5,7 & 8 (Boy's & Girl's Hostel) described as above 5 5 Set 56 873 2 84 365
13.00 NSR MCCB BOXES
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
Supply, installation, testing & commissioning of MCCB in Sheet Steel enclosure
made out of 2 mm thick CRCA sheet suitable for 3 phase 4 wire 50Hz AC system
complete with four pole Moulded Case Circuit Breaker suitable for incoming &
outgoing termination including power coating etc. complete as per specification & as
Total Distribution Board Carried over to Summary 8 21 318 10 64 050
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
S.H.-III LIGHT FIXTURES & FANS
1.0 DSR-2025 - Supplying and fixing brass batten/ angle holder including connection etc. as required.
2.0 DSR-2025 - Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact
1.41 fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc.
directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC
insulated, copper conductor, single core cable and earthing etc. as required. 42 42 Each 259 10 878
3.0 DSR-2025 - Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct
9.1 Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades,
30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding,
steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as
below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)
less than 10%, remote (preferably mobile app based) for speed control and all
remaining accessories including safety pin, nut bolts, washers, temperature rise=75
0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz,
single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external
connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single
core cable and earthing etc. as required
3.1 9.1.1 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 98 98 Each 2 730 2 67 540
4.0 DSR-2025 - Installation, Testing and Commissioning of exhaust fan in the existing opening,
1.50.1 including making good the damage, connection, testing, commissioning etc. as
required. 25 25 Each 556 13 900
5.0 DSR-2025 - Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all
6.0 NSR Supply and installation of following sweep/ sizes metallic blade, heavy duty, single
phase, 230 V A.C. Exhaust Fan in existing opening including making good the
damage, connection, testing and commissioning etc as required.
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
7.0 NSR Supply and installation of 400 mm, 230 v A.C.wall/cabin fan including fixing the
bracket, making connection, testing, commissioning etc as required. 28 28 Nos 1 843 51 604
8.0 NSR Supply, Installation, Connecting, Testing and Commissioing of Fire Exit Sign as
omniex model ( illuminated) made from etched Acrylic Sheet of 8 mm thickness, with
LED string illumination including all fittings / fixtures and electrical accessories,
power supply with Battery Charger & Battery backup etc. complete as required.
9.0 NSR Supply, Installation, Testing & Commissioning of 10-12W ( ± 2.2W) linear Mirror
light 2 ft LED integrated batten made of ultra slim aluminium extrusion with housing
part in white finish & PC diffuser part in opal finish.White finish ABS end caps with
decorative circular coloured polycarbonate cap snap fitted on the end cap to
enhance the aesthetic of the fixture. High efficiency long life LED with lumen efficacy
of 100 lm/W (±10%) with viewing angle of 120º.Powered by an integral isolated low
THD electronic LED driver. Lumen Output of 1200 lumens (±10%) .CRI >80, Color
temperature 3000K, THD <20% and PF>0.9,IP20 . Life class of 25,000 hrs @ L70,
Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V,
Frequency :50-60 HZ; Internal Surge Protection:3 KV.
10.0 DSR-2025- Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down
8.2 lighter (Round/ square/ Rectangular) SMD type of following body material with
PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per
the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of
2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,
UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time
(LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of
initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As
per ANSI Bin), SDCM (Standard Deviation Colour Matching) Powder coated die cast
/Extruded aluminium
Body including trim
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
11.0 DSR-2025- Supplying, Installation, Testing and commissioning of Passive Infrared(PIR)
7.2 technology based occupancy sensor with day light dimming(lighting level shall be
regulated as per availability of natural day light in an area along with occupancy
detection.) having high performance, regulating programmable type, suitable for
connected load upto 10Amp , for mounting height up to 3 mtr and for 5 m diameter
coverage area along with necessary fixing arrangements i/c programming at site etc.
complete as required 54 54 Each 9 760 5 27 040
12.0 NSR Supply, Installation, Testing & Commissioning of Surface/Ceiling mounted 60 watt
LED Down Light with minimum efficacy 110 lm/w complete with integrated electronic
driver etc directly on walll ceiling including connections with 1.5 sq.mm FRLS pVC
insulated copper conductor etc. as required. 10 10 Each 7 500 75 000
13.0 DSR-2025- Supplying, Installation, Testing & Commissioning of LED surface mounted Batten
8.9 light of following body material and construction as per IS : 10322 with driver
(Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage
AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal
surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥
0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver
& electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen
maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),
SDCM(Standard DeviationColour Matching) <3, Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant BIS
standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing
on housing. complete in all respect i/c external connections with 1.5 sq mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy ≥ 105 <120
lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures
as per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-inCharge as per requirement. (Thermal management: heat sink of
aluminium housing such that LED junction temperature shall not rise above 90°C).
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
14.0 NSR Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy
100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection
and complete u.,ith integrated electronic driver etc directly on wall/ceiling including
connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as
15.0 NSR Supplying and fixing wall mounted light bracket/ fixture made with polycarbonate
suitable for single 9/10 watt LED lamp directly on wall including connections etc as
required. ( But without lamp ) 140 140 Each 1 224 1 71 360
16.0 DSR-2025- Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following
8.7 body material and construction as per IS : 10322 with driver as per the requirement
with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,
Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short
& Open circuit protection ,THD < 10% , P. F. ≥ 0.95, IP20, CRI >80, UGR (Unified
Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver
& electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen
maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),
SDCM(Standard Deviation Color Matching) <3, Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant BIS
standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing
on housing. complete in all respect i/c external connections with 1.5 sq mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy ≥ 120 <135
lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as
per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-
in-Charge as per requirement. (Thermal management: heat sink of aluminium
housing such that LED junction temperature shall not rise above 90 ° C) Powder
coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
17.0 NSR Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy
duty fan including fixing the bracket, making connection, testing, commissioning etc
as required. 0 0 Each 1 950
18.0 NSR Supply, Installation, Testing & Commissioning of Aviation obstruction light with
Light Emitting Diods (LEDs) similar to Bajaj make cat no. BGAV 302 LED or its
equivalent as per approved list of make complete with all accessories as required.
Total Light Fixtures & Fan Carried over to Summary 12 11 330 5 30 091
S.H.-IV EATHING & LIGHTNING PROTECTION
1.0 DSR-2025 - Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and
5.2 providing masonary enclosure with cover plate having locking arrangement and
watering pipe etc with charcoal/coke and salt as required. 2 2 Set 7 658 15 316
2.0 DSR-2025 - Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
5.4 accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as 6 6 Set 8 351 50 106
3.0 DSR-2025 - Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including
5.6 accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as
required. 2 2 Set 15 004 30 008
4.0 DSR-2025 - Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for
5.14 connections etc. as required. 75 75 Metre 1 246 93 450
5.0 DSR-2025 - Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for
5.20 connections etc. as required. 0 0 Metre 2 245
6.0 DSR-2025 - Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections
5.15 etc. as required 250 250 Metre 287 71 750
7.0 DSR-2025 - Providing and fixing 50 mm X 5 mm G.I. strip on surface or in recess for connections
2X5.15 etc. as required 50 50 Metre 574 28 700
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
8.0 DSR-2025 - Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing
5.18 along with existing surface/ recessed conduit/ submain wiring/ cable as required. 250 250 Metre 50 12 500
9.0 DSR-2025 - Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing
5.16 etc. as required. 150 150 Metre 84 12 600
10.0 DSR-2025 - Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long,
6.1 G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate
including holes etc. complete as required. 15 15 Each 609 9 135
11.0 DSR-2025 - Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
6.7 lightning conductor complete as required. (For horizontal run) 250 250 Metre 238 59 500
12.0 DSR-2025 - Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
6.8 lightning conductor complete as required. (For Vertical run) 375 375 Metre 100 37 500
13.0 DSR-2025 - Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm
6.10 long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as
required. 15 15 Each 140 2 100
14.0 DSR-2025 - Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground
6.11 as required. 350 350 Metre 221 77 350
16.0 NSR Supply, Installation, Testing & Commissioning of Earthing Junction Box size -
400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank
process & powder coating, earthing link (25mm x 6mm copper strip) front door with
glass as complete as required. 1 1 Set 3 250 3 250
Total Earthing & Lightning Protection Carried over to Summary 5 00 015 3 250
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
S.H.-V CABLE, CABLE TRAY & TERMINATION
2.0 NSR Supply of following sizes of 1.1KV grade copper conductor XLPE insulated PVC
sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be
purchased only after approval of cable schedule by architect / consultant).
2.1 NSR 4 core, 16 sq. mm. Cu. Armoured Cable 45 45 Meter 2 044 91 980
2.2 NSR 4 core, 10 sq. mm. Cu. Armoured Cable 20.8845 20.8845 Meter 1 382 28 862
2.3 NSR 4 core, 6 sq. mm. Cu. Armoured Cable 0 0 Meter 870
3.0 NSR Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated PVC
sheathed (Heavy duty) armoured cable conforming to relevant IS. (Cable shall be
purchased only after approval of cable schedule by architect / consultant).
3.3 NSR 3.5C x 50 Sq.mm. 0 0 Meter 463
3.4 NSR 3.5C x 70 Sq.mm 0 0 Meter 635
3.5 NSR 3.5C x 95 Sq.mm. 0 0 Meter 782
3.6 NSR 3.5C x 120 Sq.mm. 0 0 Meter 980
4.0 DSR-2025 - Supply & making end termination with brass compression gland & aluminium lugs
11.1 for following size of FRLS insulated and FRLS sheathed aluminium conductor cable
of 1.1KV grade as required.
4.1 11.1.32 4 X 6 sq. mm (25mm) For copper armoured cable 4 4 Set 325 1 300
4.1 11.1.32 4 X 10 sq. mm (25mm) For copper armoured cable 6 6 Set 325 1 950
4.2 11.1.33 4 X 16 sq. mm (28mm) For copper armoured cable 8 8 Set 366 2 928
4.3 11.1.20 3.5 X 25 sq. mm (28mm) For aluminium armoured cable 2 2 Set 371 742
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
4.4 11.1.21 3.5 X 35 sq.mm (32 mm) For aluminium armoured cable 12 12 Set 437 5 244
4.5 11.1.22 3.5 X 50 sq.mm (35 mm) For aluminium armoured cable 0 0 Set 484
4.6 11.1.23 3½ X 70 sq. mm (38mm) For aluminium armoured cable 0 0 Set 542
4.7 11.1.24 3½ X 95 sq. mm (45mm) For aluminium armoured cable 0 0 Set 684
4.8 11.1.25 3½ X 120 sq. mm (45mm) For aluminium armoured cable 0 0 Set 710
4.9 11.1.26 3.5 X 150 sq.mm (50 mm) For aluminium armoured cable 0 0 Set 798
4.10 11.1.27 3½ X 185 sq. mm (57mm) For aluminium armoured cable 2 2 Set 798 1 596
5.0 DSR-2025 - Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power
10.8 cable of 1.1 KV grade of following size on cable tray as required.
5.1 10.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) 355.8845 355.885 Meter 53 18 862
5.2 10.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 0 0 Meter 109
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
6.0 DSR-2025 - Fixing for laying of one number PVC insulated and PVC sheathed / XLPE power
10.7 cable of 1.1 KV grade of following size on wall surface as required.
6.1 10.7.1 Upto 35 sq. mm (CIamped with 1 mm thick saddte) 45 45 Meter 64 2 880
6.2 10.7.2 Above 35 sq. mm and upto 95 sq. mm (Clamped with 25 x 3 mm MS flat clamp) 0 0 Meter 151
6.3 Above 95 sq. mm and upto 185 sq. mm (Clamped with 25/40 x 3 mm MS flat
8.0 DSR-2025 - Supplying and installing following size of perforated Hot Dipped Galvanised Iron
4.6 cable tray (Galvanisation thickness not less than 50 microns) with perforation not
more than 17.5%, in convenient sections, joined with connectors, suspended from
the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
8.1 4.6.1 100 mm wide x 50 mm depth x 1.6 mm thickness. 35 35 Meter 754 26 390
8.2 4.6.2 150 mm wide x 50 mm depth x 1.6 mm thickness. 10 10 Meter 803 8 030
8.3 4.6.4 300 mm wide x 50 mm depth x 1.6 mm thickness. 12 12 Meter 1 062 12 744
8.4 4.6.6 450 mm wide x 50 mm depth x 2.0 mm thickness. 10 10 Meter 1 439 14 390
8.5 4.6.7 600 mm wide x 50 mm depth x 2.0 mm thickness. 45 45 Meter 1 925 86 625
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
9.0 DSR-2025 - Supplying and installing following size of perforated Hot Dipped Galvanised Iron
4.7 cable tray "bends" (galvanisation not less than 50 microns) with perforation not more
than 17.5%, in convenient sections, joined with connectors, suspended from the
ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
9.1 4.7.1 100 mm wide x 50 mm depth x 1.6 mm thickness. 4 4 Meter 1 252 5 008
9.2 4.7.2 150 mm wide x 50 mm depth x 1.6 mm thickness. 2 2 Meter 1 368 2 736
9.3 4.7.4 300 mm wide x 50 mm depth x 1.6 mm thickness. 3 3 Meter 1 977 5 931
9.4 4.7.6 450 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 2 844 5 688
9.5 4.7.7 600 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 3 985 7 970
9.6 4.7.12 750 mm wide x 62.5 mm depth x 2.0 mm thickness. 0 0 Meter 5 122
10.0 DSR-2025 - Supplying and installing following size of perforated Hot Dipped Galvanised Iron
4.8 cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more
than 17.5%, in convenient sections, joined with connectors, suspended from the
ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
10.1 4.8.1 100 mm wide x 50 mm depth x 1.6 mm thickness. 4 4 Meter 1 427 5 708
10.2 4.8.2 150 mm wide x 50 mm depth x 1.6 mm thickness. 2 2 Meter 1 486 2 972
10.3 4.8.4 300 mm wide x 50 mm depth x 1.6 mm thickness. 3 3 Meter 2 294 6 882
10.4 4.8.6 450 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 3 324 6 648
10.5 4.8.7 600 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 4 687 9 374
11.0 DSR-2025 - Supplying and installing following size of perforated Hot Dipped Galvanised Iron
4.9 cable tray "Cross member"(galvanisation not less than 50 microns) with perforation
not more than 17.5%, in convenient sections, joined with connectors, suspended
from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
11.1 4.9.1 100 mm wide x 50 mm depth x 1.6 mm thickness. 4 4 Meter 1 427 5 708
11.2 4.9.2 150 mm wide x 50 mm depth x 1.6 mm thickness. 2 2 Meter 1 486 2 972
11.3 4.9.4 300 mm wide x 50 mm depth x 1.6 mm thickness. 3 3 Meter 2 513 7 539
11.4 4.9.6 450 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 3 770 7 540
11.5 4.9.7 600 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 4 702 9 404
11.0 DSR-2025 - Supplying and installing following size of perforated Hot Dipped Galvanised Iron
4.10 cable tray "Cross member"(galvanisation not less than 50 microns) with perforation
not more than 17.5%, in convenient sections, joined with connectors, suspended
from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
11.1 4.10.1 100 mm wide x 50 mm depth x 1.6 mm thickness. 4 4 Meter 1 771 7 084
11.2 4.10.2 150 mm wide x 50 mm depth x 1.6 mm thickness. 2 2 Meter 2 049 4 098
11.3 4.10.4 300 mm wide x 50 mm depth x 1.6 mm thickness. 3 3 Meter 2 991 8 973
11.4 4.10.6 450 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 3 929 7 858
11.5 4.10.7 600 mm wide x 50 mm depth x 2.0 mm thickness. 2 2 Meter 5 418 10 836
13.0 DSR 2023 - Constructing brick masonry chamber for underground C.I. inspection chamber and
19.30 bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with
(CIVIL) frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame
to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C.
top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar
1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement
on walls and bed concrete etc. complete as per standard design :
13.1 19.30.2 Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets.
13.1.1 19.30.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1 1 Each 8 151 8 151
13.2 19.30.3 Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
13.2.1 19.30.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1 1 Each 9 594 9 594
13.3 DSR 2023 - Extra for depth beyond 45 cm of brick masonry chamber
13.3.1.1 19.31.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1 1 Meter 6 681 6 681
13.3.2.1 19.31.3.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 1 1 Meter 7 790 7 790
14.0 DSR-2025 - Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars
15.14 jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine
sand) including testing of joints etc. complete.
HDPE PIPE FOR LV SERVICES
15 DSR-2025 - Supplying and laying of following size DWC HDPE pipe ISI marked along with all
15.15 accessories like socket, bend, couplers etc. conforming to IS 14930, Part II
complete with fitting and cutting, jointing etc. in the existing trench, complete as
15.1 DSR-2025, 200 mm dia (OD-200 mm & ID-175 mm nominal)
15.2 DSR-2025, 160 mm dia (OD-160 mm & ID-135 mm nominal)
15.3 DSR-2025, 90 mm dia (OD-90 mm & ID-76 mm nominal)
Total Cable, Cable tray & Termination Carried over to Summary 9 09 060 2 85 052
S.H.-VII UPS SYSTEM
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
1.0 DSR-2025 - Supplying, installation, Testing & Commissioning of following capacity at full load
26.1 (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable
for Single Phase input, Single Phase output AC Supply. The UPS shall include a
Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH
capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup
time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass
switch along with provision for manual bypass, suitable isolation transformer for
additional protection against neutral faults etc. The UPS systems shall be
Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor
(IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation)
Technology. The quality of design, manufacturing and inspection process should
confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating
efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total
harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be <
5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme
power factor kit to be include to limit the input pf to 0.99 and output power factor
shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall
be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be
suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output
AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload
capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40
0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter
distance, Protection for Under voltage, over voltage, abnormal output voltage,
battery over charging, output over current, short circuit, battery deep discharge , 10
KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall
comply with low voltage electromagnetic compatibility (EMC) achieved as per EN
6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent
(VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with
IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open
protocol for BMS integration as per approved by Engineering in charge. Required
battery racks, DC breaker of suitable rating and interconnecting copper conductor
cable of suitable size and connectors and all required accessories are inclusive in
Suitable The UPS shouldbetween
of Cables have QR code which
battery should
bank and UPScontain drawing,
and battery test report
fuse protection.
Total UPS System Carried over to Summary 1 09 793
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
S.H.-VIII TV & TELEPHONE SYSTEM
1.0 Supply and fixing of telephone distribution board (tag blocks) in hinged type MS box
duly powder coated complete with bakelite sheet, Krone connector etc including
termination of incoming and outgoing telephone wire etc. complete as required.
1.1 NSR 10 pair telephone distribution board. 1 1 Nos. 559 559
2.0 NSR Supply and wiring of telephone cable 0.61mm dia annealed tinned copper conductor
PVC insulated and PVC sheathed unarmoured telephone cable in existing conduit in
concealed/ surface system / existing cable tray complete as required.
2.1 10 pair telephone unarmoured cable. 50 50 Meter 60 3 000
3.0 NSR Supply, erection, testing and commissioning of following sizes of splitter of
aluminium die cast body in suitable size of G.I. Box.
Total Cable, Cable tray & Termination Carried over to Summary 5 953
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
S.H.-IX FIRE ALARM SYSTEM (ADDRESSABLE TYPE) & PA SYSTEM-
(A) FIRE ALARM
1.0 DSR-2025- Supplying, installation, testing and commissioning of micro processor based
28.2.1 intelligent addressable main fire alarm panel, central processing unit with the
following loop modules and capable of supporting not less than 240 devices
(including detectors) and minimum 120 detectors per loop and loop length up to 2
km, network communication card, minimum 320 character graphics/ LCD display
with touch screen or other keypad and minimum 4000 events history log in the non
volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up
with 24 volt sealed maintenance free batteries with automatic charger. The panel
shall have facility to connect printer to printout log and facility to have seamless
integration with analog/digital voice evacuation system (which is part of the schedule
of work under SH: PA System) and shall be complete with all accessories . The
panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over
IP complete as per specifications.
1.1 DSR-2025- Two Loop Panel.
2.0 DSR-2025- Supplying, installation, testing & commissioning of intelligent analog addressable
28.2.4 photothermal detector complete with mounting base complete as required. 10 10 Nos. 3 004 30 040
3.0 DSR-2025- Supplying, installation, testing & commissioning of intelligent addressable thermal
28.2.9 detector with rate of rise cum fixed tempreature thermistor complete with base as
required. 2 2 Each 2 866 5 732
5.0 DSR-2025- Supplying, installation, testing & commissioning of addressable manual call point
28.2.14 complete as required. 28 28 Each 4 063 1 13 764
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
6.0 DSR-2025- Supplying, installation, testing & commissioning of addressable horn cum strobe
28.2.15 complete as required. 28 28 Each 3 682 1 03 096
7.0 DSR-2025- Supplying, installation, testing & commissioning of addressable fire control module
28.2.10 complete as required. 28 28 Each 3 156 88 368
8.0 DSR-2025- Supplying, installation, testing & commissioning of response indicator on
28.2.5 surface/recessed MS Box having two LED, metallic cover complete with all
connections etc as required. 2 2 Each 306 612
9.00 DSR-2025- Supplying, installation, testing & commissioning of fire fighter phone jack complete
10.00 DSR-2025- Supplying, installation, testing & commissioning of fire fighter telephone handset
28.2.17 complete as required. 2 2 Each 6 016 12 032
12.00 NSR Supplying & laying of 2x1.5 sqmm fire survival unarmoured cable, 600/1000V rated
with annealed copper conductor having glass mica fire barrier tape covered by an
extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and
LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as
required. 744 744 Meter 135 1 00 440
13.00 DSR-2025- Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
1.17 single core cable in the existing surface/recessed steel/ PVC conduit as required.
14.00 DSR-2025- Supplying and fixing of following sizes of STEEL conduit alonwith the accessories in
1.20 surface/recess including painting in case of surface conduit, or cutting the wall and
making good the same in case of recessed conduit as required.
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
15.0 NSR Supply, Installation, Testing and Commissioning of Addressable Output Module with
inbuilt isolators. Shall be UL / EN54 certified. 2 2 Nos. 3 695 7 390
PUBLIC ADDRESS SYSTEM
17.0 NSR SITC of IP based Networkable touch screen paging station for selection of zones,
supervision of system status, setting of scheduled broadcasts with the following
. Built-in monitoring loudspeaker
. Detachable goose-neck microphone
. LCD touchscreen display
Total Addressible Fire Alarm & PA system Carried over to Summary 8 18 106 1 42 945
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
S. H. X LIFT SYSTEM
1.0 NSR PASSANGER LIFT (13 PASSENGER) (MRL)
NSR Supply, installation, testing, commissioning,and final testing of 13 Passenger (884
KG) automatic lift complete in the shaft well and pit already constructed as per
CPWD specification including automatic rescue device (ARD), All standard
equipments, accessories and control equipments as per manufacturer's design and
as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to
NBC/statutory norms and fulfilling following requirements.
(i) Type : Passenger lift.
(ii) Load : As per specified elsewhere 13 Passenger (884 KG) (for each person
standard weight 68 Kg.)
(iii) Speed : 1.50 Meter / second.
(iv) Control : ACV3F, 32 bit Microprocessor integrated serial communication control
system with RMS (Remote monitoring systema0 / BMS (Building Monitoring system)
supporting software.
(v) Motor / Machine : Permanent magnetic synchronous gearless motor.
(vi) Operation : Simplex collective selective with / without lift attendant.
(vii) Total rise : About 3 meters (Approx) two stops only.
(viii) Landings :- All floors on same side.
(ix) G+5 floor (6 Stops/6 Landings)
(x) Signals : Digital car position indicator, car travel direction indicator inside car & at all
landings, Voice annunciator with suitable music shall provide in the lift car.
(xi) Shaft size : As per manufacturer's design and as per CPWD specification (Part III
Lifts), shaft to be constructed separately.
(xii) Guide rail : As per manufacturer's specification.
(xiii) Lift & Car size : As per manufacturer's design and as per CPWD specification (Part-
(xiv) Car entrance : As per manufacturer's design and as per CPWD specification (Part-III
(xv) Landing entrance :- As per manufacturer's design and as per CPWD specification
(Part-III Lifts)
(xvi) Car Door : S.S. (Stainless steel) hairline finish centre / Telescopic opening door with
(xvii) Landing door : S.S. (Stainless steel) hairline finish centre / Telescopic opening door
with vision panel.
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
(xviii) Door operation : Automatic electric power operated door, full height infra red curtain
with multiple cross / cross light beams.
(xix) Car interior : S.S. (Stainless steel) panel with hair line finish on all sides.
(xx) Car floor : Anti skid PVC flooring on heavy duty MS (Mild Steel) platform.
(xxi) Car ceiling & lighting : S.S. (Stainless steel) finishes with aesthetic appearance with
LED ceiling lights.
(xxii) Car ventilation : Pressure fan / Blower fan (Car fan with automatic appearance with
LED ceiling lights.
(xxiii) Emergency lighting in car : Battery operated emergency lighting in the lift car.
(xxiv) Intercom system : Battery operated Intercom system in lift car, machine room and
ground floor / control room.
(xxv) Emergency alarm : Battery operated alarm bell system in lift car & control room /
(xxvi) Position of machine room : Directly above the hoist-way.
(xxvii) Electric power supply : AC 415V, 3 phase, 50 Hz & AC 230V, 1 Phase 50 Hz
terminated in machine room.
(xxviii) Fire man switch : Fire man switch at machine room / Terminal landing.
(xxix) All car panel buttons and all floor switches must be with brail language as per lift act.
(xxx) Audio visual indication in the lift car showing overloading shall be provided such that
doors kept open till excess load is removed.
(xxxi) Spring buffer / Hydraulic buffers shall be provided.
(xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.
(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift
pit should be provided by the lift agency, along with the other steel structure works,
foundations for the machines etc.
(xxxiv) In the hoist way facia plate shall be provided.
(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with
fixtures, exhaust fan, plug points and 3 phase 440 V power supply shall be made
available by the department in lift shaft, machine room or at desired level.
(xxxvi) Car top safety barricade shall be provided.
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
(xxxvii) ARD (Automatic rescue device) : Solid state inbuilt automatic rescue device (ARD)
for automatically rescues passengers trapped in the lift car in between floors in the
event of power failure. Automatic operation and immediate action in the event of
mains failure capable to move the lift to the nearest landing, opens the automatic
door of the lift car and floor. Sealed maintenance free battery backup with automatic
charging unit and auto changeover device on mains failure.
Total Lift system Carried over to Summary 43 10 000
S. H. XII DATA, WI-FI (PASSIVE COMPONENTS)
1.0 DSR-2025- Supplying, Installation, Testing and commissioning of CAT6A Copper Information
39.15 Outlet (IO) with face plate of color as per site requirement, should have ETL/UL
verification program certificate for compliance with ANSI/TIA-568.2-D. All copper
Cable and Components should be from same OEM to maintain compatibility and
interoperability etc. complete as required 175 175 Nos. 302 52 850
2.0 DSR-2025- Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid
39.18 copper cable in existing conduit/ on surface, U/FTP, LSZH, NonPlenum, Horizontal
(solid) Cable suitable for high speed data networking application supporting upto
10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with
color coded insulation for easy indentification should have FLAME PROPERTIES i.e.
Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards
compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew
should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should
have been tested and verified by UL/ ETL etc.complete as required.
2.2 39.18.2 2 Run of cable 0 0 Meter 124
2.3 39.18.2 3 Run of cable 0 0 Meter 124
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
3.0 DSR-2025- Supplying Installation Testing and Commissioning of 24 port Cat 6 Patch Panel
39.11 loaded. Must be of 1U height with clear label holders and white label with the panel
24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for
compliance with ANSI/TIA-568.2-D etc. complete as required. 12 12 Each 5 278 63 336
4.0 DSR-2025- Supplying, installation, Testing and commissioning of following capacity 24 port
39.3 Layer 2 indoor Network Switch having features and specifications etc.as mentioned
here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base
-T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of
min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table.
Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC
Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo
Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups
1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3,
UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol
VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS ,
TACACS+ Authentication, Ǫ oS: 802.1P, 8 queues per port, Ǫ oS : WRR,
Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number,
time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP
server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP,
OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit
Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC,
RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of
Telecommunication, Government of India etc. complete as required.
4.1 39.3.1 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each
copper port supporting 802.3at PoE+ min. 3 3 Each 1 25 393 3 76 179
4.2 39.3.2 24 port Layer 2 Non-PoE Network Switch 6 6 Each 86 163 5 16 978
5.0 DSR-2025- Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord
39.13 should have ETL/UL verification program certificate for compliance with ANSI/TIA-
568.2-D etc. complete as required.
5.1 39.13.1 Copper Patch Cords of length 1m (3ft) 175 175 Each 173 30 275
5.2 39.13.2 Copper Patch Cords of length 3m (10ft 175 175 Each 405 70 875
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
7.0 DSR-2025- Supplying, Installation, Testing and commissioning of CAT6A Copper Information
39.15 Outlet (IO) with face plate of color as per site requirement, should have ETL/UL
verification program certificate for compliance with ANSI/TIA-568.2-D. All copper
Cable and Components should be from same OEM to maintain compatibility and
interoperability etc. complete as required. 175 175 Each 302 52 850
9.0 DSR-2025- Supplying and drawing following core Fiber Optic Cable having corrugated steel
39.19 armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic
jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC
G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated
Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature
should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C,
Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22db /
km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D &
Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding
Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value <
3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260
nm i/c splicing & marking etc complete as required.
9.1 39.19.1 Single Mode 6 Core Optical fiber cable 110 110 Meter 64 7 040
9.2 39.19.2 Single Mode 12 Core Optical fiber cable 0 0 Meter 89
10.0 DSR-2025- Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted
39.21 cable saddles for jumper management, suitable to manage both splices and
terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted
bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for
900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight
buffered fiber per adapter, Removable front and rear covers for better access to
interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit
consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
11.0 DSR-2025- Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to
39.21 LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber
corning single mode G652D, Cable Type 2mm with Mechanical specification Apex
Offset < 50 µ m, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R
<25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C,
Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex
etc complete as required.
12.0 DSR-2025- Supplying, Installation, Testing and commissioning of indoor Wireless Access Point
39.7 for Low Density use having features and specifications etc. as mentioned here under
- Dual-band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6
Certified, 1 x RJ45 console port, 1G LAN POE Port, factory reset,
WPA/WPA2/WPA3 ™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast
disable, MAC address access control, Internal RADIUS server, SNMP,
Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS
with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control,
Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-
PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/
IP ACL for networks, Certifications: MTCTE, CE, FCC. Should also work as
Standalone and must be Compatible with S/W & H/W Controller with addtional
features like - Real-Time Monitoring and Alerts, Rich Advanced Features,
Centralized Device Management, Role-Based Administration, Real-Time Monitoring,
VLAN and Access Control, Auto RF Management and Bandwidth Optimization,
Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted
Telecom Portal of Department of Telecommunication, Government of India etc. 20 20 Each 22 739 4 54 780
complete as required.
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
13.0 DSR-2025- Supplying, Installation, Testing and commissioning of Outdoor Wireless Access
39.9 Point having features and specifications etc. as mentioned here under - WIFI 6
Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, 4 x internal
antennas, the transmission coverage of shall be minimum 80 meters in radius, AP
should have transmission power minimum of 22 dBm, The AP shall provide a
minimum of 29 dBm EIRP for both 2.4 GHz and 5 GHz frequencies. Feild
deployment shall be with EIRP as per regulatory guidelines, AP shall have dual-band
Omni-directional Antenna, either internal or external. Feild deployment shall be with
EIRP as per the WPC guideline, WPA/WPA2/WPA3 ™ Personal/Enterprise, WEP
64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS
server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point,
WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL),
Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced
security – WPAPSK/WPA2-PSK/WPA3-PSK and RADIUS client, and Cipher
negotiation, and MAC/ IP ACL for networks, IP68 water/dustproof standard, 6KV
Surge Protection; 4KV ESD Protection (contact), 6KV (air), Operating ambient
temperature (-5~50 ° C), Grounding point support, IEC 60601-1-2 EMC Medical
Electrical Equipment Testing and Certification, EN50121-1 & EN50121-4 for
Wireless Application. Certifications: MTCTE, CE, FCC. Works as Standalone,
Compatible with S/W & H/W Controller with addtional features like - Real-Time
Monitoring and Alerts, Rich Advanced Features, Centralized Device Management,
RoleBased Administration, Real-Time Monitoring, VLAN and Access Control, Auto
RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal
Authentication.OEM/Product must be on Trusted Telecom Portal of Department of
Telecommunication, Government of India etc
14.0 DSR-2025 - Supplying and fixing of following sizes of PVC conduit along with the accessories in
1.21 surface/recess including painting in case of surface conduit, or cutting the wall and
making good the same in case of recessed conduit as required.
Total Data, WiFi including Active components Carried over to Summary 34 51 572
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
S. H. XIII IP BASED CCTV SYSTEM
1.0 DSR-2025- Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera
40.3 having following specifications and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display
Camera title, Date & Time in live & recorded video
2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at
night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or
better) True Day & Night High Performance Mechanical IR cut filter with auto switch,
Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50
meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s
electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light
Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu,
4) Wide Dynamic Range:- WDR (120dB or more)
5) Digital Noise Reduction:- DNR (3D) On/Of
6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream:
4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps
7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness
adjustable through client software or web browser, Edge Analytics: Tripwire,
Intrusion, Motion Detection
8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted
execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering,
HTTPS, trusted upgrade
9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card
slot upto 512 GB. It should be supplied with minimum 128GB memory Card.
10) Recording Management: Format SD, overwrite, storage management, video to
11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP
conflict detection; memory card state detection; memory space detection
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS,
SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
13) System Capability: ONVIF, Camera shall support open source VMS
14) Ethernet: 1 RJ 45 10/100 Ethernet port
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic.
and Speakers as per site requirement.
16) Power Input: The camera should support simultaneous dual power input — 12
VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the
event of a failure in one power source.
17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE
18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body
19) Operating Condition:- Ambient Temperature:- (- )05 ° C to 50 ° C, humidity 95%
(max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or bette
22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
22.3.2 4MP @ 25/30fps@1440P (2560x1440) Dome Camera with 2.7 to 4 mm ~12 to
13.5mm or better Varifocal Motorized lens. 21 21 Nos. 23 754 4 98 834
2.0 NSR Supply, Installation, Testing and Commissioning of UL Listed , ONVIF profile S & G ,
1/1.8" progressive CMOS, IP Bullet Camera , Full, HD 2 MP, fixed Lens, 30 FPS
@2MP , Triple Stream with Edge Based Analytics : perimeter intrusion detection ,line
crossing detection , stationary object,face detection, cross counting. True Day/Night
with IR Cut Filter with auto switch , Shutter Speed 1/5s ~ 1/10,000 s, IR Illuminator
30 Meter Min Effective Range, 100DB Wide Dynamic Range, Alarm 1/1, H.265,
H264 Compression, PoE, Vandal Proof IK10 etc. 1 1 Each 28 475 28 475
3.0 DSR-2025- Supplying Installation Testing and Commissioning of following Channel Network
40.11 Video Recorder (NVR) with camera licenses to record for all channels having
specifications and features etc as mentioned below :
1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera
Licenses to record per NVR and to provide a live view, storage and simultaneously
Multi-channel playback of all IP camera or more and must be ONVIF with minimum
support of 384 Mbps incoming Bandwidth.
2) NVR should support video compressions : H.265 or better, H.264, MJPEG
3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with
G.711U/A, G.711u, PCM, G726 audio compressions.
4) Intelligent auto power on when power resumes after power outage.
5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and
RAID support of RAID 0/1/5/6/10.
6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x
RS232, 1x eSATA Port
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)
8) Video Output Ports: 2x HDMI and 2 VGA
9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of
external sensors and output devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5
designated mobile number for power failure, HDD failure, vandalism, tempring,
network disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone)
for alerts and viewing.
12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP,
IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, AutoRegistration,
ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote
monitoring without any public IP need.
13) Standards: CE, FCC, RoHS, BIS Certified
14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.
15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)
16) The VMS application shall support all the features & functionalities of the offered
17) VMS should consist Licenses for all channels to record Cameras with General,
motion detection, intelligent, alarm and POS recording modes. VMS should be
provided with Camera Licenses , with no dependency of VMS licenses by binding
with the MAC address of the cameras to achieve the functionality
18) The NVR OEM shall be responsible for providing a mobile application
compatible with both Android and iOS devices, enabling remote monitoring and
playback of cameras/NVR footage
19) The OEM must provide its own DDNS server hosted in India, eliminating the
need for a public IP address for remote monitoring over the Internet.
20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode
21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP;
1080p; 720p; D1; CIF; QCIF
22) When alarm recording is enabled and an event occurs, you can click the alarm
icon on monitoring page to view the alert details. The snapshot function is supported
on monitoring and playback page
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
23) The Network Video Recorder (NVR) shall be configured to send email whenever
a system message is created or an alarm event occurs. The email server shall be a
valid SMTP server. Each recipient email address shall be configured to receive any
combination of critical, warning, or informational messages or alarm notifications.
When an alarm occurs, the email message includes the NVR name, time of alarm
and a list of camera that is configured to record upon alarm
24) It should have Web and GUI interface
25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face
detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8
Channel Smart Motion Detection
26) Face Recognition Database Capacity: It should support total Blacklist and
Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of
12 face images/sec and facility to add Name, gender, birthday, address, credential
type, credential No., countries & regions and state to each face image.
27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group,
glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender
28) ANPR Capability: It should support ANPR Camera with License plate, plate
color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration
location etc vehicle attributes
29) Alarm Notifications based on: Motion detection, video tampering, video loss,
scene changing, PIR alarm, Camera external alarm, Face detection, face
recognition, perimeter protection (intrusion and tripwire), ANPR, people counting,
stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict
and abnormal behavior of fan, cybersecurity exception
30) Alarm Notification should be linked with Recording, snapshots, Camera external
alarm output, buzzer, logs, presets and email.
31) General AI Based Search: Search Pictures by channel, time, event type, target
classification (Fall Detection, People Approach Detection, People No. Exception
Detection, People Staying Detection, Violence Detection.
32) Smart playback function: Should support smart search for the selected area in
the video and smart playback to improve the playback efficienc
33) VCA (Video Content Analytic): Should support multiple video contented analytics
based on camera analytics
34) Analytics by NVR: Perimeter protection and face recognation
40.11.1 32 Channel Network Video Recorder (NVR) having display split :- Main screen:
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
IP based CCTV System Carried over to Summary 5 63 618 28 475
Digitally signed by JAYA
ELECTRICAL WORKS
S.No. DESCRIPTION OF ITEM QUANTITY TOTAL UNIT
NSR DSR NSR DSR NSR
Digitally signed by JAYA
Estimate For HVAC Work
Proposed -Phase –II Infrastructure Development works of the Permanent Campus of Indian
Institute of Management Sambalpur, Odisha
DETAILED ESTIMATE FOR DOUBLE OCCUPANCY GIRLS HOSTEL - HVAC WORK
S.NO DSR-2025 / DESCRIPTION UNIT AMOUNT (INR)
1) Sub Head 'A' - Machinery INR 5348188 1417274
2) Sub Head 'B' - Refrigerant & Drain Piping INR 621964 151310
3) Sub Head 'C' - Ducting & Grilles INR 298595 231851
4) Sub Head 'D' - HVAC Electric Work INR 0 1455772
Total Estimated Cost INR 6268747 3256207
ADD EXTRA GST ON DSR 0 0
TOTAL INCLUDING LABOUR CESS 6268747 3256207
SUB TOTAL (DSR+NSR) FOR ONE BLOCK 95,24,954
GRAND TOTAL (DSR+NSR) FOR 3 NOS. OF BLOCK 2,85,74,862
GRAND TOTAL (DSR+NSR) FOR 3 NOS. OF BLOCK 2,85,74,862
Design Centre Consulting Engineers Pvt. Ltd., Vaishali, NCR Delhi, Ph-0120-4333451, 4333452 1 JAYA
Digitally signed by
Proposed -Phase –II Infrastructure Development works of the Permanent Campus
of Indian Institute of Management Sambalpur, Odisha
DETAILED ESTIMATE FOR ONE BLOCK OF DOUBLE OCCUPANCY GIRLS HOSTEL - HVAC WORK
S.NO DSR-2025 / DESCRIPTION UNIT RATE (INR) AMOUNT (INR)
NSR QYT. DSR NSR DSR NSR
Sub Head 'A'- Machinery
1) Variable Refrigerant Volume / Flow Air-conditioning System
Supply, Instalaltion, testing and commissioning of Variable Refrigerant
Flow /Volume (VRF/VRV) (with the latest technology/version) with All-
Inverter driven Compressor, modular type airconditioning system
with stepless modulation for both heating & cooling modes, complete
with indoor and outdoor units, individual remote controller and
centralized controller, interconnected refrigerant piping with insulation,
Y joints, full charge of refrigerant gas including additional top up and
oil, control cabling etc. as per detail given in specifications and having
following items. The prices to be given in Indian rupees including
all taxes and duties and delievered at site. Refrigerant to be used
shall be - R 410 A only.
It shall be complete as per specifications,with connectivity to
automation for A/M status, RUN status & Remote start/stop
command.(Bacnet/IP) with multi connection kits for each outdoor unit
& First charge of refrigerant gas for the VRF/VRV Units & required
MS frame work or required foundation & anti vibration pads for
mounting the outdoor units. installation, testing & commissioning of air
cooled VRV/VRF system shall include pipe pressure testing &
flushing with nitrogen, charging of gas/oil etc. & will include all
lifting/shifting etc.
1.1) Air Cooled VRV / VRF Outdoor Unit
Digitally signed by JAYA
Supply, Installation, Testing & Commissioning of Modular type
Variable Refrigerant Flow/Variable Refrigerant Volume air cooled
Outdoor units suitable for cooling/heating having 100% hermetically
sealed inverter type twin Rotary/Scroll Compressor(s), minimum two
compressors (with individual seperate PCB) for above 14HP modules,
microprocessor based Controller, top discharge type condensing
unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with
suitable foundation etc. complete as required. To have better
efficiency condensor fan shall be capable to operate at different
speed with respect to load. The unit shall deliver the rated capacity
and in confirmation as per IS 18728:2024 and CPWD Specifications
and work even at 50°C ambient temperature without tripping.
The system shall be able to deliver 100% of the rated capacity upto
39 Degree Celcius. The unit shall be suitable to work on 400V +/-
10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit
shall be filled with first charge of the refrigerant and ready for use as
required. The condenser should be coated with a hydrophilic film to
prevent water accumulation on the surface of the heat exchanger,
enhance water dispersion, and reduce the risk of degradation, thereby
improving overall performance and durability. The Indian Seasonal
Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy
Conservation and Sustainable Building Code (ECSBC) 2024 as below
and complete as per CPWD specification, connections, inter
connections etc. as required. (For capacity <40 kWr ISEER 7.4,
Capacity >40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super
ECSBC Building)
1.1.1) DSR-2025 14 HP Cool / Heat Pump Unit Nos. 1 303226 303226 0
1.1.2) DSR-2025 30 HP (12 HP+18 HP) Cool / Heat Pump Unit Nos. 3 662994 1988982 0
1.1.3) DSR-2025 32 HP (14 HP+18 HP) Cool / Heat Pump Unit Nos. 1 693088 693088 0
2) Indoor Units
Digitally signed by JAYA
Supply, Instalaltion, testing and commissioning of Indoor units
equipped with pre-filter, fan section with suitable static fan to
distribute the air as per approved shop drawings, multispeed motor,
coil section with DX coil, outer cabinet / cassette panel, drain
pan, insulation, pipe connections etc. of various capacities as per
specifications and drawings.
2.1 DSR-31.8 VRV Hi Wall Unit - Supply, Installation, Testing and Commissioning
of following minimum capacity High wall type Indoor unit equipped
with and comfort washable synthetic media pre-filter, fan section with
low noise fan/dynamically balanced blower, multispeed motor, coil
section with DX copper coil, electronic expansion valve, outer cabinet,
cord less remote control, drain pan, necessary accessories etc.,
suitable for operation on 230 V ± 10%, 50 Hz, single phase AC
supply, complete as required. The Indoor units must shut down upon
receiving a singal from the BMS System/Fire Singnals. The system
shall be capable to adjust air flow as per room requirement
automatically. The cooling capacity of indoor unit will be at air inlet
conditions of 27 Degree C DB and 19 Degree C WB temperature.
(Make will be same as of Outdoor)
2.1.1 31.8.1 0.6 TR VRV Hi-wall Unit Nos. 0 16790 0 0
2.1.2 31.8.2 0.8 TR VRV Hi-wall Unit Nos. 0 17276 0 0
2.1.3 31.8.3 1.0 TR VRV Hi-wall Unit Nos. 0 17816 0 0
Sub Head 'A'- Machinery
2.2) DSR-31.13 Y-joints For Indoor Unit
Supply, Installation, Testing and Commissioning of Y/T/Multi Joints.
Joints shall be of same Original Equipment Manufacturer (OEM)
make as of ODUs and IDUs
Digitally signed by JAYA
2.2.2 DSR-31.13.2 Outdoor Multi Joint 4 8098 32392 0
Sub Head 'A'- Machinery
2.3) Self Diagnostic Type Individual Remote Controllers (Corded
NSR Supply, Installation, Testing & Commissioning of Corded Wall SET 72 4721 339912
Mounted Type Self Diagnostic Type Digital Programmable Individual
Remote Controllers of latest generation for setting required
temperature for various Indoor Unit.
2.4) Self Diagnostic Type Individual Remote Controllers (Cordless
NSR Supply, Installation, Testing & Commissioning of Cordless Type Self SET 9 3230 29070
Diagnostic Type Digital Programmable Individual Remote Controllers
of latest generation for setting required temperature for various Indoor
2.5) Main Intelligent Programmable Central Controller (Corded Type)
NSR Supply, installation, testing and commissioning of Main centralized SET 6 118514 711084
controller / manager digital type of latest generation for VRV/VRF
system for controlling all the indoor & outdoor units installed in
building with adapters (for connecting additional indoor units, cost for
the same is deemed to be included in this item) with On / Off, touch
screen and Temparature Controls, fan speed, scheduling, air flow
direction setting, operation history etc. The controller should be
compatible with automation system (Bacnet/IP) with all accessories. It
should be complete as per manufacturing standards & as per
directions of Engineer-in-charge.
Sub Head 'A'- Machinery
3) Accoustically Insulated Box Type Inline Fans
Digitally signed by JAYA
Supplying, installing, testing and commissioning of INLINE FANS
suitable for installing in any position in vertical or horizontal ducts. The
casing shall be double skin, internally acoustically lined and
constructed of galvanised steel. with efficient motor, fire retardent
double layer canvass connection etc complete in all respect & of
following capacities. The casing shall be selected for lower noise
level. Fan motor shall have inbuilt speed controller.
3.1) NSR 600 CFM (15mm static pressure, single phase) Nos. 11 13976 153736
4) Plastic Propeller Fans
Supplying, installing, testing and commissioning of direct driven
PROPELLER FANS. Each fan shall be complete with permanent split
capacitor or shaded pole motor, mounting plate with light weight type
PVC impellers with aerofoil contours for high efficiency & low noise &
gravity louvers for weather protection as required. Fan selection
arrangement and Electrical characteristics shall be as follows :
4.1) NSR Up to 125 CFM, 6 Inch Dia, 3 mm St. Pr., Single Phase No. 3 1980 5940
4.2) NSR Above 125 CFM and Up to 250 CFM, 8 Inch Dia, 3 mm St. Pr., Single Nos. 1 2640 2640
4.3) NSR Above 250 CFM and Up to 500 CFM, 10 Inch Dia, 3 mm St. Pr., Nos. 11 3300 36300
5) GI Propeller Fans
Supplying, installing, testing and commissioning of direct driven
PROPELLER FANS. Each fan shall be complete with permanent split
capacitor or shaded pole motor, mounting plate with light weight type
GI impellers with aerofoil contours for high efficiency & low noise &
gravity louvers for weather protection as required. Fan capacity shall
be as follows :
5.1) NSR 750 CFM, 300 mm Dia, 3 mm St. Pr., 900 RPM, Single Phase No. 0 4620 0
Sub Head 'A'- Machinery
Digitally signed by JAYA
6) Axial Flow Fan
Supply, installation, testing and commissioning of ceiling mounted
Tube Axial flow fans with adjustable pitch blade, MS / GI long casing
(2mm thick up to 800 mm dia fan, 3 mm thick from 900 to 1250 mm
dia & 4 mm thick above 1300 mm dia) , cast aluminium alloy impeller
complete with TEFC Sq. Cage Induction motor IE-3 suitable for
415 volts ± 10%, 50Hz ± 3 %, three phase A.C supply with
support, mountings, vibration isolators, fire retardant flexible canvass
connector 150 mm deep (Inlet & Outlet as required), bird screen (Inlet
& Outlet as required) etc. & of following capacity. The complete fan
along with motor shall be high efficient one with fire rated (class H)
suitable for withstanding 250 ° C temperature rated for 2 hours. Fan
outlet velocity shall be limited to maximum of 16 m/sec. Fan & Fan
motor KW given below are for guideline & actual Dia / KW shall be as
per manufacturer selection based on maximum 16 m/sec outlet
Axial Fan shall be AMCA certified for Air and Sound performance in
accordance to AMCA 210 and AMCA 300. Complete Fan shall be
tested and approved by CE / UL / EN in accordance with "Power
Ventilators for Smoke Control Systems" for 250 ° C for 2 hours.
Manufacturer shall furnish AMCA Test Certificate for air & sound
performance along with UL / EN fire test certificate (Latest) for each
fan sourced from that particular factory. The noise level of axial fan
shall be less than 80 dBa at a distance of 3.0 mt from the fan. The fan
shall be low RPM (less than or equal to 1000 RPM) and capacities
shall be as follows. Wattage of motor shall be as per actual selection
meeting other technical parameters
6.1) NSR 7000 CFM (25mm static pressure, Axial Fan, 960 / 1450 RPM, 2.2 Kw Nos. 2 69296 138592
Fan Motor or as required, 600 MM Fan Dia)
7) 32.2 Hi-wall Split Unit (5 Star Rated) For Various Areas as per basis of
design, UPS, Fire Control Room, CCTV Room, Hub Room etc.
Digitally signed by JAYA
Supplying , Installation, Testing and Commissioning of Air
Cooled Hi Wall split type Air conditioners complete with
Indoor unit(IDU), Out door unit (ODU), surface / concealed
copper Refrigerant piping with insulation (closed cell
elastomeric nitrile rubber tubular pipe section) upto 3 Mtr
(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to
ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,
wireless Remote control, suitable for working between 180-
260V with low & high voltage cutoff and 50 hz ,1 phase AC
supply capable of performing cooling, dehumidification, air
circulation of following capacity with Scroll / rotary
compressor. The system shall be able to deliver 100% of
the rated capacity upto 42 0C. Min 5 year Original Equipment
Manufacturer (OEM) warranty both compressor
and Printed Circuit Board (PCB). Must comply : Electrical
cable IS 694 or IS 9968 temperature sensing control IS
/International Electrotechnical Commission (IEC) 60730,
hermetic compressor IS 10617, heat exchanger IS 11329,
capacitor IS 2993 and motor IS 12615. Complete as per
CPWD specification and IS : 1391 Part II 2023. The system
shall be able to operate up to 50 0C (out door ambient
7.1) .75 TR, Inverter Type - Cooling only with 5 Star BEE Rating NO 0 39095 0 0
7.2) 1.0 TR, Inverter Type - Cooling only with 5 Star BEE Rating NO 0 40580 0 0
7.3) 1.5 TR, Inverter Type - Cooling only with 5 Star BEE Rating NO 2 43539 87078 0
7.4) 2.0 TR, Inverter Type - Cooling only with 5 Star BEE Rating NO 2 57396 114792 0
Total of Sub Head 'A'- Machinery Carried to Summary of Prices. 5348188.0 1417274.0
Sub Head 'B' - HVAC Plumbing
1) Condensate Drain Piping With Nitrile Rubber Insulation
Digitally signed by JAYA
Supply, installation, testing and commissioning of UPVC condensate
drain water piping of density 10 Kg/m ³ complete with fittings like
elbows, tees, reducers, bends, flanges, supports & duly insulated
with "O" class Closed Cell Elastomeric Nitrile Rubber of specified
pipe section of specified thickness etc. as required and of following
1.1) NSR 25 mm dia pipe, 13 mm Insulation RMT 260 310 80600
1.2) NSR 32 mm dia pipe , 13 mm Insulation RMT 50 339 16950
1.3) NSR 40 mm dia pipe , 13 mm Insulation RMT 140 384 53760
1.4) NSR 50 mm dia pipe , 13 mm Insulation RMT 0 516 0
2) DSR -31.14 Insulated Refrigerant Piping for VRV / VRF System
Supplying, Installation, testing and commissioning including
vaccumiazation and Nitrogen testing of following nominal
sizes of soft/hard drawn copper refrigerant piping for
VRV/VRF system, complete with fittings, with suitable
adjustable ring type hanger supports, jointing/brazing
including accessories, insulated with XPLE Class-O tubular
insulation/with Class-O closed cell elastometric nitrile
rubber tubular sleeves sections of 19 mm thick insulation
as given below for Suction and Liquid lines, all accessories
as per specifications etc. as required
2.1) DSR -31.14.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm RMT 260 256 66560
thick insulation
2.2) DSR -31.14.2 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm RMT 260 346 89960
thick insulation
2.3) DSR -31.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 RMT 280 487 136360
mm thick insulation
2.4) DSR -31.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 RMT 80 615 49200
mm thick insulation
2.5) DSR -31.14.5 19.1 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 RMT 140 739 103460
mm thick insulation
Digitally signed by JAYA
2.6) DSR -31.14.6 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 RMT 70 904 63280
mm thick insulation
2.7) DSR -31.14.7 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 RMT 0 1068 0
mm thick insulation
2.8) DSR -31.14.8 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with RMT 60 1157 69420
19 mm thick insulation
2.9) DSR -31.14.9 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 RMT 0 1222 0
mm thick insulation
2.10) DSR -31.14.10 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 RMT 34 1286 43724
mm thick insulation
2.11) DSR -31.14.11 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 RMT 0 1322 0
mm thick insulation
2.12) DSR -31.14.12 41.3 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 RMT 0 1368 0
mm thick insulation
Total of Sub Head 'B'-HVAC Plumbing carried to Summary of 621964.0 151310.0
Sub Head 'C' - Ducting & Grilles
1) 30.12.1 Rectangular GI Ducting (Factory Made - L Shape)
Supply, installation, balancing and commissioning of factory
fabricated GSS sheet metal rectangular/round ducting complete with
neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
1.1) 30.12.1.1 24 G, Thickness 0.63 mm sheet (Up To 750 mm) Sqmt. 170 1191 202470
1.3) 30.12.1.3 20 G, Thickness 1.0 mm sheet (1501 to 2250 mm) Sqmt. 0 1488 0
Digitally signed by JAYA
1.4) 30.12.1.4 18 G, Thickness 0.80 mm sheet (Above 2250 mm) Sqmt. 0 2013 0
2) 30.12.2 Site Fabricated GI Ducting
Supply, installation, balancing and commissioning of site fabricated
GSS sheet metal rectangular/round ducting complete with neoprene
rubber gaskets, elbows, splitter dampers, vanes, hangers, supports
etc. as per approved drawings and specifications of following sheet
thickness complete as required.
2.1) 30.12.2.1 24 G, Thickness 0.63 mm sheet (Up To 750 mm) Sqmt. 30 1213 36390
2.2) 30.12.2.1 22 G, Thickness 0.80 mm sheet (751 to 1500 mm) Sqmt. 0 1415 0
2.3) 30.12.2.1 20 G, Thickness 1.0 mm sheet (1501 to 2250 mm) Sqmt. 0 1851 0
2.4) 30.12.2.1 18 G, Thickness 0.80 mm sheet (Above 2250 mm) Sqmt. 0 2063 0
4) Duct Accoustic Lining
30.21 Supplying and fixing of acoustic lining of supply air Sqmt. 0 890 0
duct and plenum with 25 mm thick resin bonded glass
wool having density of 32 kg/m³, with 25 mm X 25 mm
GI section of 1.25 mm thick, at 600 mm centre to centre covered with
Reinforced Plastic tissue paper
and 0.5 mm thick perforated aluminium sheet fixed to
inside surface of ducts with cadmium plated nuts,
bolts, stick pins, CPRX compound in confirmation to
SMACNA/IS and as per specifications complete etc.
5) 30.23 Duct Insulation
Supplying and fixing of following thickness duly laminated aluminum
foil of mat finish closed cell Elastomeric EPDM Rubber insulation on
existing duct, Density 40-60 kg /cum , Class A as per ASTM E 84 ,
Class V-0 as per UL 94 and Mu value > 7000, tape & adhesive
(pidilite SR -998) etc or Nitrile Rubber with ASTM E84 complies. The
joints shall be sealed with 50 mm wide and 3 mm thick self adhesive
EPDM rubber tape insulation complete as per specifications and as
Digitally signed by JAYA
Sub Head 'C' - Ducting & Grilles
7) Grilles, Diffusers, VCD
Supply, installtion and testing of Powder coated Aluminium
extruded grills / diffusers as per specifications given in tender
and of following sizes.
7.1) 30.15 Supplying & fixing of powder coated extruded aluminium Supply Air Sqmt. 0 9623 0
Grills with aluminium volume control dampers as per specifications.
7.2) 30.16 Supplying & fixing of powder coated extruded aluminium Return Air Sqmt. 5 6285 31425
Grills with louvers without volume control dampers complete as
7.3) 30.17 Supplying, fixing testing commissioning of supply air diffusers of Sqmt. 0 12841 0
powder coated aluminium with aluminium volume control dampers
with anti smudge ring & removable core.
7.4) 30.18 Supplying, fixing testing commissioning of Return air diffusers of Sqmt. 0 8595 0
powder coated aluminium without volume control dampers with anti
smudge ring & removable core.
7.5) NSR Supplying, fixing testing commissioning of Fresh / Exhaust air louvers Sqmt. 2 9783 19566
with bird screen & damper
7.6) NSR Supplying, fixing testing commissioning of Volume control GI Sqmt. 5 4612 23060
Dampers to be provided in Supply / Exhaust air registers / terminals.
Sub Head 'C' - Ducting & Grilles
8) 30.13 GSS Duct Damper
Digitally signed by JAYA
Supply, installation and testing of multiblade box type Galvanized SMT 1 7580 7580
Sheet Steel construction damper for ducts to be provided with
suitable links and quadrants for control of volume of air.
9) NSR Under Deck Insulation of Exposed Roof
Supplying and fixing of thermal insulation on exposed roof
(underdeck) with EPDM Rubber foam with completely closed cell
structure as per specifications - Density 40-60 kg /cum , Class A as
per ASTM E 84 , Class V-0 as per UL 94 and Mu value > 7000 or
Nitrile Rubber with ASTM E84 complies, tape & adhesive (pidilite SR
-998) as required & finally fixed with the help of rawl plug & dash
fasteners in ceiling.
Total of Sub Head 'C'-Ducting & Grilles carried to Summary of 298595.0 231851.0
Sub Head 'D' - HVAC Electric Work
1) NSR Electrical Sub Panel
Supply, installation, testing and commissioning of cubical floor / wall
mounted type switch board as detailed below & switch gears suitable
for AC-23 duty with digital energy meter on incoming feeders of all
Sub-Panels covered under this Item, including making interconnection
etc as required. BMS compitable dual source energy meter with
maximum demand shall be taken in main incomer of HVAC Panels.
1.1) NSR Isolator Switch With Metal Enclosure For ODU (IP-65) No. 5 8580 42900
40 A 4 pole RCBO for VRV Outdoor Units with sheet metal enclosure,
rain protection etc. as required to suit the site condition.
1.2) NSR Isolator Switch With Metal Enclosure For ODU (IP-65) No. 4 9899 39596
Digitally signed by JAYA
63 A 4 pole RCBO for VRV Outdoor Units with sheet metal enclosure,
rain protection etc. as required to suit the site condition.
1.3) NSR AHU & Axial Fan Motor Up to 3.7 KW No. 2 24947 49894
40 A TPN MCB with 16 A DOL starter, overload relay, start /
stop push buttons, phase indication lights with protection fuse, on / off
/ trip indication lights with protection fuse, single phase preventer &
auto / manual mode selector switch. Set - 01
Controls & interlocking accessories as required. Lot
'D' - HVAC Electric Work
2) NSR Single Phase MCB for VRV Indoor Units / Inline Fan / Propeller
Supply, Installation, Testing & Commissioning of suitable size PVC / Set 107 1254 134178
G.I. Box with 6A / 10A / 16A SP MCB, loop in loop out connector and
box cover etc as required at site.
3) NSR Starter for Propeller / Inline fan (Single Phase)
Supply, Installation, Testing & Commissioning of modular type single Set 26 1214 31564
phase motor starter up to 6 A / 10 A / 16 A (Rating shall be as per
motor) including suitable size G.I. Box with modular, modular cover
plate, conduiting and wiring from starter to fan etc as required at site.
4) NSR Power & Control Cabling
Supply, laying, testing and commissioning of power and control
cabling as per specification given in the tender. Power cabling of
XLPE insulated Aluminium / Copper conductor armoured cables
of 1.1 KV Grade including cable end termination with brass
compression glands & aluminium lugs etc as per specification.
Note:- Copper cable upto 16 Sq. mm & above shall be Aluminium
4.1) NSR For Motor Up to 3.73 Kw
Digitally signed by JAYA
1 x 3C x 4 Sq. mm Copper RMT 30 388 11640
4.2) NSR For Motor of 5.5 Kw
1 x 3C x 6 Sq. mm Copper RMT 0 541 0
4.3) NSR For Motor of 7.5 / 9.3 / 11 Kw
2 x 3C x 6 Sq. mm (Rate for Single Run) Copper RMT 0 541 0
4.4) NSR For VRV ODU Unit (From AC Panel to Isolators near ODU)
4.4.1) NSR 1 x 4C x 10 Sq. mm Copper RMT 150 874 131100
4.4.2) NSR 1 x 4C x 16 Sq. mm Copper RMT 100 1252 125200
4.4.3) NSR 1 x 4C x 25 Sq. mm Aluminium RMT 50 402 20100
4.5) NSR For VRV Outdoor / HW ODU (From Isolators to Unit)
4.5.1) NSR 1 x 4C x 4.0 Sq. mm Copper Flexible Cable RMT 125 293 36625
4.5.2) NSR 1 x 4C x 6.0 Sq. mm Copper Flexible Cable RMT 50 428 21400
4.5.3) NSR 1 x 4C x 10.0 Sq. mm Copper Flexible Cable RMT 30 732 21960
Sub Head 'D' - HVAC Electric Work
4.6) NSR For VRV Indoor Unit Inline Fan / Propeller Fan (From MCB to
NSR 1 x 3C x 2.5 Sq. mm Copper Flexible Cable RMT 240 171 41040
4.7) NSR B) Control cabling (PVC insulated Copper conductor of 1.1 KV
Grade armoured cable)
Digitally signed by JAYA
4.8) NSR C) Transmission & Control Wiring For VRV System
Providing & fixing of control cum trans-mission wiring of copper
between indoor and out door unit in 25 mm PVC Conduit.
5) NSR Earthing Strip / Wires as per specs.
5.1) NSR Supply & laying of 6 SWG GI wire or in recess for loop earthing as RMT 400 50 20000
5.2) NSR Supply & laying of Rubber mat 1000 mm. Wide to withstand 1.1 KV RMT 20 2628 52560
dielectric strength as per latest IS 15652-2006.
6) NSR Cable Tray
Supplying and installing following size of perforated GI cable trays
including bends. tee, reducers etc with perforation not more than
17.5%, in convenient sections, joined with connectors, suspended
from the ceiling with GI suspenders including bolts & nuts,
suspenders etc as required.
6.1) NSR 100 mm wide x 50 mm depth x 1.6 mm thickness. RMT 300 701 210300
6.2) NSR 150 mm wide x 50 mm depth x 1.6 mm thickness. RMT 200 866 173200
6.3) NSR 300 mm wide x 50 mm depth x 1.6 mm thickness. RMT 50 998 49900
6.4) NSR 600 mm wide x 50 mm depth x 1.6 mm thickness. RMT 0 998 0
Digitally signed by JAYA
Total of Sub Head 'D'- HVAC Electric Work carried to Summary 0.0 1455772.0
Digitally signed by JAYA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
NIT-66.pdf
Tender Document
PMC_GCC_2026 with Amendment 04.pdf
Tender Document
SCC.pdf
Tender Document
Integrity Pact.pdf
Tender Document
Technical Specifications.pdf
Tender Document
Drawings.pdf
Tender Document
List of Approved Makes.pdf
Tender Document
Technical Circular.pdf
Tender Document
Physical Milestone.pdf
Tender Document
BOQ.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .