Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.3 CrAccepted-AOC 443 V P O LIWAN 132001 | KARNAL | HARYANA | 132001 | ₹2.3 Cr | 1 | Accepted-AOC Work Allotted |
| 2 | 2₹2.7 Cr+₹40.5 L (17.5%)Rejected-AOC SCT 3 H NO 2030 ROHTAK SCT 3 H NO 2030 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹2.7 Cr+₹40.5 L (17.5%) | 2 | Rejected-AOC Work Not Allotted |
| 3 | 3₹2.9 Cr+₹55.2 L (23.8%)Rejected-AOC 464 21 NEW ANAJ MANDI TOHANA 125120 | FATEHABAD | HARYANA | 125120 | ₹2.9 Cr+₹55.2 L (23.8%) | 3 | Rejected-AOC Work Not Allotted |
| Sl No | Description | Qty | Unit | Surinder Singh Hooda L2 | Sunil Kumar L3 | Krishan Kumar L1 |
|---|---|---|---|---|---|---|
| 1.00 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (50 Sqmm size) | 60 | Per Metre | 400 ₹24,000 | 550 ₹33,000 | 100 ₹6,000 Lowest |
| 2.00 | PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
3400 LPM x 20 .00 M Head | 2 | Each | 1,20,000 ₹2,40,000 | 1,50,000 ₹3,00,000 | 80,000 ₹1,60,000 Lowest |
| 3.00 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications with PN 1.6 complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026 Dated on: 13 April 2026)
200 mm dia | 4 | Each | 1,500 ₹6,000 Lowest | 5,000 ₹20,000 | 5,000 ₹20,000 |
| 4.00 | `MPS (MAIN PUMPING STATION): Design, construction and commissioning of MPS for 4.50 MLD average flow with peak factor 2.5 including RCC Inlet chamber, suitable size flow meter, screening chamber, wet well sump complete in all respect as per detail and specifications mentioned in attached additional documents along with following provisions:
1.1 Suitable size (as per design) K9 DI pipe at MPS for interconnecting the structures including welding and screwing of flanges, ISI marked D.I. fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respect
1.2 Suitable size (as per design and requirement) Gear Operated Sluice Gate with Rising Spindle for screens and partition of tank as per design.
1.3 Supply and installation of 2 mechanical coarse screen (SS 316) suitable for 4.50 MLD average flow with peak factor of 2.5 complete in all respect.
1.4 Conveyance of raw sewage from MPS to inlet chamber of STP through suitable size (as per design) DI pipe along with cost of DI pipe, sluice valves, specials, material and labour complete in all respect.
1.5 Raw sewage will be available near boundary wall within the premises of proposed MPS but the conveyance of sewage from this terminal point to the inlet chamber of MPS through DI K9 pipe of suitable diameter as per design is included in the Turnkey contract. The Level of the MPS / STP will be as per bed level of existing incoming sewer at MPS` | 1 | Job | 1,56,41,000 ₹1,56,41,000 | 1,60,00,000 ₹1,60,00,000 | 1,25,00,000 ₹1,25,00,000 Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹4.7 L
Closing Date
5 Jun 2026, 11:00 amClosed
NAVEEN KUMAR GOYAT
Sonipat (D and P) PHED
CONSTRUCTION OF NEW MPS AGAINST COLLAPSED MPS FOR 4 50 MLD STP AT KHARKHODA TOWN DISTT SONIPAT
2026_HRY_524434_1
202619C8C65B F2F0 4F1F 9E2B 3A3504AE9DF9588PUH
Open Tender
Civil Works
Works
365 days
Kharkhoda
2 documents required · 2 mandatory
₹15,000
₹4.7 L
Yes
26 Aug 2026
26 May 2026
5 Jun 2026
26 May 2026
5 Jun 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. (50 Sqmm size) | 60 | Per Metre | - | - |
| 2 | PANEL BOARDS FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
3400 LPM x 20 .00 M Head | 2 | Each | - | - |
| 3 | Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications with PN 1.6 complete in all respect of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and specified makes as per direction of Engineer in charge. (As per HSR, Gazette notification no. 15-2026 Dated on: 13 April 2026)
200 mm dia | 4 | Each | - | - |
| 4 | `MPS (MAIN PUMPING STATION): Design, construction and commissioning of MPS for 4.50 MLD average flow with peak factor 2.5 including RCC Inlet chamber, suitable size flow meter, screening chamber, wet well sump complete in all respect as per detail and specifications mentioned in attached additional documents along with following provisions:
1.1 Suitable size (as per design) K9 DI pipe at MPS for interconnecting the structures including welding and screwing of flanges, ISI marked D.I. fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respect
1.2 Suitable size (as per design and requirement) Gear Operated Sluice Gate with Rising Spindle for screens and partition of tank as per design.
1.3 Supply and installation of 2 mechanical coarse screen (SS 316) suitable for 4.50 MLD average flow with peak factor of 2.5 complete in all respect.
1.4 Conveyance of raw sewage from MPS to inlet chamber of STP through suitable size (as per design) DI pipe along with cost of DI pipe, sluice valves, specials, material and labour complete in all respect.
1.5 Raw sewage will be available near boundary wall within the premises of proposed MPS but the conveyance of sewage from this terminal point to the inlet chamber of MPS through DI K9 pipe of suitable diameter as per design is included in the Turnkey contract. The Level of the MPS / STP will be as per bed level of existing incoming sewer at MPS` | 1 | Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_603379.xls
BOQ • 0.34 MB
1F4BN0Z163272.pdf
Additional Documents • 4.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .