Construction of Urban Water and Waste Management Office Building at Hambran Road, Ludhiana
2026_DLG_163492_1
587/SE(TIC)
Open Tender
Civil Works
Item Rate
365 days
Ludhiana
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹44 L
O/o SE(TIC), Zone A MCL
19 Jun 2026
12 Mar 2026
31 Mar 2026
12 Mar 2026
31 Mar 2026
12 Mar 2026
17 Mar 2026
Figure
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Foundation
Columns
Beams
Walls
Grade Slab
Lintels
Extra rate for First Floor
Extra rate for Second Floor
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Total qty for all floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for Third Floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for First Floor
Extra rate for Second Floor
Extra rate for First Floor
Extra rate for Second Floor
Total Qty for all floor
UPVC 160 mm bend
Third Floor roof
Note vii Ch-13
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Total qty for all floor
Extra rate for Third Floor
Total qty for all floor
Note iv Ch-14
Note iv Ch-14
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
Total qty for all floor
Note iv Ch-14
Note iv Ch-14
Second Floor
Ground Floor
Total Qty for all floor
Note iv Ch-14
Note iv Ch-14
Note iv Ch-14
Total All Floors
Note iv Ch-14
Note iv Ch-14
Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
CSR Anal
CSR Analy
MR Analy
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Total A1:-
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Lintel
Fascia
Shelves
Ground Floor
Note-ii of Ch.-9
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)
Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect
Analy
Ground Floor
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Analy
Total A2:-
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Column
Beams
Lintels
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)
Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Iron grated doors, including pintle hinges and arrangements. (Duct Covering)
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Total A3:-
Assembly Area
Total A4:-
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Iron grated doors, including pintle hinges and arrangements.
Total B1
Granular Sub Base Grade I Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, carriage from mix plant to site of work, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. IS COde : 15658 (2006)
Total B2 :-
Total B3:-
Total A1+A2+A3+A4+B1+B2+B3:-
PUBLIC HEALTH SERVICES
Sub Work-1
Total Sub Head-1:-
Sub Head-2 Internal Water Supply System
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
qty same as GI P 15mm i/d to 25 mm (Table-2)
Total Sub Head-2:-
Sub Head - 3 Sanitary Installation
Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. Detail attached as per Table-3
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Detail attached as per Table-3
Providing and fixing in position Metropole flush valve push type 32mm size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect. Detail attached as per Table-3
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
For 2000 ltr Water Tank
Total Sub Head-3:-
Sub Head-4 Flooring and Wall Tile
Total All Floor
Note iv Ch-14
Note iv Ch-14
Total All Floor
Note iv Ch-14
Note iv Ch-14
Note iv Ch-14
Note iv Ch-14
Total All Floor
Note iv Ch-14
Note iv Ch-14
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Total Sub Head-4:-
Sub Head -5 Drinking Water Coller
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Total Sub Head-5:-
Sub Work-2
Providing UGSR 100000 ltr including pump house
First Floor
Extra rate for First Floor
walls
Note-ii of Ch.-9
Ground Floor
First Floor
Ground Floor
Ground Floor
Ground Floor
Ground Floor
First Floor
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
First Floor
Extra rate for First Floor
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Total Total Sub Head-5:-
Sub Work-2
Sub Head-2 Estate Water Supply
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Providing & fixing C.I indicating plates of size 100mm x 100mm for SV/FH including synthetic enammel paint & letters in white enamel paint , fixing in the ground with angle iron of size 25x25x5mm, 230mm height from ground including concrete block complete in all respect as directed by Enginner-in-Charge.
Total Sub Work-2
Sub Work-3
Sub Head-3.1
Sub Head-1 Estate Sewerage
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
Total Sub Head-3.1:-
Sub Work-4
Roof Top Rain water Harvesting
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
xxiii
Total Sub Work-4:-
Sub Work-5
Fire Fighting Arrangements as per NBC Code
Providing and fixing of FIRE EXTINGUISHER, Mechanical Foam Type 9 ltr IS: 15683 Stored Pressure type complete with all accessories as per Manufactures Specification. ISI Mark of approved make complete in all respect.
Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects.
Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOSE as per IS:8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipes.
Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect.
Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
Supplying an Fixing Pendant / Upright type sprinkler with quartzoid bulb, operating temperature 68 / 79 degree centigrade of 15 mm dia orifice sprinler head to approved by UL/SN
Supplying and Fixing Sidewall Sprinkler rated at 68 / 79degree centigrade, quartzoid bulb type, 15 mm dia orifice sprinler head to approved by UL/SN complete in all respect.
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
For 10000 ltr Water Tank
Total Sub Work-5:-
Providing & Installation of VRV/VRF Air Conditioning System
EQUIPMENT
Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll/DC Twin rotary compressor controlled by individual inverters for each compressor complete with indoor and outdoor units with individual wired and wireless /wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply.
Outdoor Units
VRV/VRF Outdoor Unit
Supply, Installation, Gas Charging, Testing and Commisioning of Air Cooled VRV/VRF units with rotary/scroll Compressor capable of modulating capacity from Min 20%- 100%or more working on R410A/or as per OEM design with heating & cooling both. The prices should include all works such as lifting, shifting and positioning of outdoor units. The unit shall be factory charged & any top-up gas/oil required for first charge including nitrogen leak testing, oil charging, vaccumisation shall be in scope of agency. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish
The Module shall have multiple scroll compressors and be able to operate even in case of breakdown of one of compressor.. Each circuit of Module units shall have Multiple compressors for better redundancy incase of breakdown.
The heat exchanger for Outdoor shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. The Condenser fins must be coated with Anti-corrosive treatment.The following safety devices shall be part of the outdoor unit:- High Pressure Switch, Low Pressure Switch, Fan Motor Safety Thermostat, Over Current Relay, Fusible Plugs, Fuses. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping. The outdoor units shall have a minimum COP of 3.1 at 100% loading and ISEER of 6.5 at ARI conditions (To crosscheck COP orginal data sheet to be provided from OEM ), the ODU shall have condenser fan capable of minmum 7 speeds or better technology for saving energy at various loading conditions.
The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply.
All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor and all outdoor units shall work even at 52°C ambient temperature without tripping
The manufacturer of ODU and compressor shall be of the same make . i.e the make of compressor shall be identical of the ODU. Contractor to include all necessary charge of refrigerant & connecting kits for AHU & Y joints as per there design
PCB Casing should be IP 55 protected and Universal PCB shall be used in all ODUs
Contractor to include all necessary charge of refrigerant & connecting kits for AHU & Y joints as per there design
Insurance of Units ,Unloading at site, placement of Oudoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned VRF/VRV by OEM.
Note: The civil foundations reqd shall be made by the tenderer
Make :Daikin, Mtistibushi Electric, Toshiba,O General,Carrier,Blue Star
VRV/VRF Indoor Units
Supply, installation, testing and commissioning of below mentioned capacity Casstte/ Ductable type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports, Double layer TF Canvass Connection(for Ductables) etc. as per specification and drawing.
The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired/Wireless remote control from the respective locations.
Along with Drain pump as a standard accessory and shall be included in the price of units
Four Way Cassstte Acs along with its grill Panels
Hi Wall Units
Mid /High Static Ductable Acs
Make :Daikin, Mtistibushi Electric, Toshiba,O General,Carrier,Blue Star
Treated Fresh Air Unit (TFA)
SITC of following minimum capacity VRV/VRF Treated Fresh Air Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet, drain pump grill, necessary supports, vibration isolation, Cordless remote control etc suitable for operation on 230 V +- 10% 50 Hz AC supply
Refnet / T / Y- Joints
Make :Daikin, Mtistibushi Electric, Toshiba,O General,Carrier,Blue Star
Centralized Controller
Make :Daikin, Mtistibushi Electric, Toshiba,O General,Carrier,Blue Star
Refrigerant Piping
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with Class O closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant/Client in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.(Make : Rajco,Mandev,Totaline,)
Insulation Make : K Flex ,Armacell
Floor Mounted Air Handling Unit (DX Type SUITABLE TO REFERIGERANT R-410a)
Supply Installation Testing Commissioning of Next Generation of Weather proof (outdoor Type) Floor Mounted AHU AHRI Certified with Thermal Break Profile , 48+-2 mm thick panels consisting of pre plasticized G.I casing made of thickness 0.8 mm outside layer and GI sheet of thickness 0.8mm inside layer with polyurethene foam (PUF) CFC Free insulation of density 40+-2 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW/Suitable backward curve. The unit shall be provided with stainless steel drain pan made out of 18G SS 304 sheet duly insulated with 13mm closed cell nitrile rubber insulation.The unit shall be equiped with TEFC drive motor(Suitable for VFD) of Efficiency Class IE 3 fan with blower suitable for operation on 415 volts + 10%, 50 Hz, AC supply, 6 Row Deep cooling coil of 0.13 mm Aluminum fins and Copper tube of 1/2" copper tube of 0.6 mm thickness,Fresh Air Cut out,Mixing Box and Filter section with 50 mm thick box type pre filterme complete with expansion valve,sensors,wired remote controller & PCB, Light etc. to run the AHU as required as per following specifications
Note : AHU Must Suitable for VRV/VRF Outdoor Units and The AHU Unit shall be controlled by Central Controlled Unit
CFM TYPE SP CC /TR
AHU Expansion KITs
DUCT LINE ACOUSTIC TREATMENT
Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts/plenum using open cell nitrile rubber foam having microban anti-microbial/ anti fungal product protection and of 160-180 kg / m³ density as per ASTM D3575, class 1 ratingn As per BS476,PART-7, cut to required sizes and to be stuck to the inside of duct surfaces with adhesive as approved by the manufacturer. (Rubber based solvent). as per specifications
DUCT LINE THERMAL INSULATION (Inside Conditions)
SITC of Physically / Chemically crosslinked polyethylene foam, with factory reinforced alupet foil facing, ANTI MICROBIAL/ANTI FUNGAL,HFC & CFC free , Negligible VOC level with Class O fire properties,with very low fire propagation of < 5.5 and passing E-84 at < 25/50, as per technical specification, the density of the foam should be not less than 25-30kg/m3 and the maximum thermal conductivity K should be 0.032W/mK@ 23 Deg C , the permeability resistance factor u shouldn't be less than 14000. The product shall have temperature range of –20oC to 115oC
Physically / Chemically crosslinked polyethylene foam, with factory laminated heavy duty and ultra tough multi-layered composite aluminium foil facing, with puncture resistance of >400N and Class O fire properties as per BS 476 Part BS 476 Part 6 & 7 and as per the tender technical specification and density of the foam should be not less than 25 - 30 kg/m3 and maximum thermal thermal conductivity K should be 0.032W/mK@ 23 Deg C & the permeability resistance factor u shouldn't be less than 97000.
Make :K Flex,Armacell,Aerolam
CONDENSATE DRAIN PIPE
Providing and fixing and in position the following PVC pipes for condensate drain duly insulated with 6mm Nitrile Insulation & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the indoor units upto the main header in the shaft dor vertical risers
Astral,Diplast,Supreme,Prince
AIR SIDE WORKS
Duct - GI duct factory Fabricated
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting as per IS 655:2006 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications.GI Sheet Should be 120GSM with RoHS complaintand TDF flange should be of 35 mm only of following sheet thickness complete as required and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to make Collors/bends/plenums/suit pieces Only
Sheet Make : Ductofab, Rolastar,ADS,zeco ( Sheet Make Sail /Tata )
Grills/Diffusers
Providing and fixing of Extruded aluminium supply and return air grilles/diffusers/ louvres with dampers,etc. duly powder coated as per specifications and drawings.
Supplying & fixing of powder coated extruded aluminium Supply/Return Air Grills with louvers as per specifications
Supplying, fixing testing commissioning of supply air diffusers with removable core (Round/Square) of powder coated aluminium complete as rquired.
Make : Sant,Pinaire,Caryaire,Systemair
Dampers
Supply, installation, testing & commissioning of Al Collar dampers
Supply, installation, testing & commissioning of CBRI approved Fire duct Dampers for at least 90 min fire rating as per UL555:1955 Specifications without Sleeve
Supply, installation, testing & commissioning of Spring Return Actuator and Control Panel Complete with Heat Sensors , Complete Control wiring and Limit switch,4NM/7NM/9NM,(24VAC/220VAC)
Make : Sant,Pinaire,Caryaire,Systemair
ASSOCIATED ELECTRICAL WORKS
AC Main Panel (CPRI Approved)
Main Electrical Panel (CPRI Approved min. 70K) for VRV/VRF System
Design ,Supply,Installation,Testing and Commissioning Electrical Main Panel weather Proof outdoor Type Powder Coated Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces duly processsed powder coated having Siemens grey colour or as approved by client or department (Outdoor Type with weatherproof canopy design)as per following specifications complete in all respect . Note : Manufacturer should have atleat CPRI Approval of 70 K
INCOMING SUPPLY 250-400Amps ,3Pole MCCB,50 KA with Microprocessor release.The MCCB shall be double break & the ICS=100% ICU = 1nos Make : Schneider/ Siemens/ABB Spreader Link with phase Barriers = 4sets Make : Schneider/ Siemens/ABB Rotary Mechanism = 1nos Make : Schneider/ Siemens/ABB Auto Phase Sequence Section ATS Suitable Amps for Auto Phase sequence with SPP alongwith On delay and required equipment Make of ATS : Socomec/HPL/Schnieder/L&T and allied material such as relay etc of Reputed Make Metering Section Load Manager EM6400NG with RS485 Port or Equivalent (Class 1.0, with RS485 Port, with Paramenters V, Amp, PF, % THD, F,W,WH,VA,VAH, VAR,VARH, Runhrs, ON hrs, Interupts = 1No. Make : Schneider / Secure / Siemens/ABB/Elmeasure/Selec Control MCB SP C Curve= 3nos Make : Schneider/ Siemens/ABB
CT's 400/5 or suitable= 3nos Make: AE/Essma/Newtek/Selec Indication Lamps LED Type RYB = 3nos Make : ABB/ Schneider/ Siemens/ESSEN/L&T/Reputed Outgoing Feeder for VRV/VRF Units - 7 nos 0-100 Amps or suitable to ODU's Pole MCCB,36 KA with Thermal magenetic release adjustable type.The MCCB shall be double break & the ICS=100% ICU = 7 nos Make : Schneider/ Siemens/ABB Spreader Link with phase Barriers = sets Make : Schneider/Siemens/ABB Rotary Mechanism = As Per requirment Make : Schneider/ Siemens/ABB Multi function Meter EM 64xx 1.0 RS or equavalent for EMS/BMS compatibilty Make : Schneider / Secure / Siemens/ABB/Elmeasure/Selec
INDICATING LAMPS LED Type Make : ABB/ Schneider/ Siemens/L&T/Reputed
Control MCB SP C Curve for control Make : Schneider/ Siemens/ABB CT's 60/5 Make: Essma/Newtek/Selec/Secure MCB TPN plus ELCB of the same rating ( 300 MA or suitable) as outgoings as per the combination of machine (Example, if in section of 26 HP VRV a Set of 1 nos 26 HP VRV each is taken then MCB TPN & ELCB 63 Amps 300MA or suitable each to be provided as O/G or in case of 12HP VRV & 14 HP combination nos MCB TPN 24 Amps & ELCB of 32 Amps and 32 Amps TPN & ELCB 40 Amps/ 300MA each to be provided for the combination or in any other combination the MCB TPN & ELCB to be provided as per requirment) Make of MCB/ELCB : Schneider/ Siemens/ABB Panel Fabrication of Powder Coated Enclosure made out of TATA/SAIL/ESSAAR/JINDAL/Reputed make CRCA sheet having 2 mm for load bearing surfaces & 1.6 mm for non load bearing surfaces ,duly processsed powder coated having Siemens grey colour. (Outdoor Type with weatherproof canopy design) Assembly charges of Aluminium Bus Bar 600A TPN Electrolite grade E91 having suitable cross section for Phase & Neutral and Current carring capacity 1 A/Sq. mm2. inclusive of Insulators, colour coded Heat shrinkable Insulation sleeve (RYBN) Assembly of Hardware (PVC Channels/MCB Channels/Fibre-Glass/Gaskits/nuts/Bolts/washers/ Terminal blocks, etc) Complete Wiring inclusive of control wiring, power wiring, Aluminium Solid connections/interconnections including insulators, thimbles,etc
Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel. Panel Make : Adlec/Siemens/Tricolite/Unitech Power System/Vrindavan Electricals/International Switch Gears Pvt. Ltd
AHU Panel
SITC of AHU panels duly powder coated wall mounted Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make CRCA Sheet of 1.6 mm thick consisting of Upto incomer as MPCB/MCCB suitable as per AHU
ON/OFF/TRIP indication light LED type, DIGITAL Ammeter with ASS; CT's 30/5; contactors up to32A or Suitable (with 2 NO+ 2NC); Start/Stop push buttons with auto & Manual control switch, Single Phase Preventer, MCB DP upto 10 Amps C Curve ,Over load Relay 16-25A or Equivalent Suitable , power & control terminals; neutral link and internal wiring & connections for AHU motors upto 5 HP or Suitable
Panel Make : Adlec/Siemens/Tricolite/Unitech Power System/Vrindavan Electricals/International Switch Gears Pvt. Ltd
Providing & fixing control cum FRLS transmission wiring/ Control Cabling of 2 core x 1.5sq. mm copper in suitable conduits between indoor and out door unit & indoor unit & its remote controller.
(Make: Havells/Ecko/Finolex/Polycab/L&T/KEI)
Under Deck Insulation
Providing & Fixing Underdeck Insulation with 50 mm thick TF Quality EPS of Density 20 Kg/M3 fixed to slab with good quality Black CPRX Compound. 28Gwirenet shall be tightened arround insulation so as avoid any kind of sagging, Ends of net shall be overlapping at least 25mm. Overlaps shall be screwed with galvanized screws to avoid rusting : Make: Beardsell,Llyod
SITC of TUBE AXIAL FAN WITH MOTOR
Supply, Installation testing & Commissioning of SINGLE Speed AXIAL Flow FAN (Make :Kruger, Systemair ,Flaktwood,LTI )complete with totally enclosed fan cooled motor direct driven, and fan shaft, motor mount, bird screen ,Isolators as per the specifications. Fan motor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply. Fans for high temperature ( except for fresh air) ratings shall be capable to work at 300 Deg C for at least 2 hours. The Axial fans shall be supplied with power panel.
Fire Mode
SITC of Starter Panels- Supply /Exhaust Air Blower up to 7.5 KW)
( BMS Compatible)
SITC of Star delta starter/DOL panel with 01 No. - 0-40 A TP MCB with Conforming to BIS DOL/Star Delta starter, overload relay, ammeter (0-63A), single phase preventer. on off push button, on/off/trip indicators with protection fuse, manual reset overload relays, armoured cabling with proper tray supports from starter panel to fan motor Starter panel should be provided with auto manual toggle switch & facility to operate on remote signal. Necessary earthing, smoke & fire detector providing signal to starter panel, related control cabling shall be part of starter panel as approved by consultants & clients.
P/F of Fire retardent canvas connections between Fan & initial duct piece
P/F of GSS Weatherproof Louvers with bird screen, adjustable damper for fresh air and exhaust air etc.
Control Cabling
Supply, installation, testing & commisioning of Copper conductor , PVC insulated, PVC sheathed armoured/Unarmoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to BMS
Make : Havell's,Eko,Finolex,Polycab
Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required.
Total of Part B (In Rupees)
XLPE INSULATED ARMOURED CABLES (LOOSE),COPPER EARTHING ,COPPER EARTHING STRIP etc.
XLPE INSULATED ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
(xxxvi)
(xxxvii)
(xxxix)
COPPER EARTHING (Upto 8 metre in Length):
Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 4.50 metre (14.76 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 8metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 3metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
COPPER EARTHING STRIP (As Additional Length):
Total of PART A
Total Sub Head 1+2+3+4+5+6:--
ELECTRICAL SERVICES
POINT WIRING:
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
(xxviii)
LED'S FIXTURES & FANS:
OCCUPANCY SENSORS:
SUSPENSION RODS FOR CEILING FANS:
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
CONDUIT PIPE & COPPER WIRES:
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
SUB DISTRIBUTION SYSTEM:
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
MAIN DISTRIBUTION SYSTEM:
MAIN VERTICAL DISTRIBUTION BOARD (EMERGENCY): TPN 4Way to feed MCB DB's (EMERGENCY LOAD) ON GROUND FLOOR
RISING MAIN: (IN ELECTRICAL ROOM)
INDOOR LT PANELS:
EARTHING SYSTEM (INDOOR):
Total D1:
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Total D2:
xxxvii
xxxvii
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
Total D3:
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Total D4:
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Total D5:
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Total D6:
FIRE PANELS & ANNUNCIATORS:
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Total D7:
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Total D8:-
160 KVA DG Set with AMF Panel for For Main Building:
Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 160 KVA /128KW with AMF Control Panel .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing 205 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms as amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.
INDOOR LT CABLES, CABLE TRAY & DWC PIPE:
(xxviii)
COPPER EARTHING
Total D9:
VACUUM CIRCUIT BREAKER: NEAR MAIN GATE & SUB STATION
Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630/800 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with POWDER COATED CRCA SHEET/ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 50 opeartion or more
VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door.
TRANSFORMER 500KVA:
APFC FOR 500KVA TRANSFORMER:
INDOOR MAIN LT PANELS :
Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44). Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS:8623. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The base channel will be made out of 75mm x 40mm x 5mm rolled channel. "The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.
HT CABLE, END TERMINATION KITS & CONTROL CABLE FOR TRANSFOMER:
INDOOR LT CABLES, CABLE TRAY & DWC PIPE:
xxxvii
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
COPPER EARTHING
SUB STATION SAFETY EQUIPMENTS:
Total D10:
M.S. FLAT/ CHANNEL BRACKETS:
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS):
Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:-
SHEET METAL IRON CLAD SWITCHES:Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Total D11
Grid interactive PV System Solar Power Plant of 63KWp:
Features: 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 14286 2. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529 3. Structure 25 Years service life with AMC & certified under IS 2062 2011 4. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material) 5. Annual Maintenance contract for the period of 5 Years 1 Solar PV Module: 2 Power Conditioning Unit: 3. Sloar Inverter: 4. Batteries 3 AC/DC Distribution Board: 4 Fusion Mount structure: 5 Lightning Arrester with chemical Earthing: The work will got done from approved MNRE (Misitry of New and Renewable Energy) / PEDA (Punjab Energy Development Agency) contractor/PWD enlisted contractor subject to condition that PWD enlisted contractor wiill get work done from MNRE/PEDA approved contractor The capacity of solar power plant may increase or decrease as availability of site it can also be totally removed by concerned Engineer-in-charge of work..
Total D12:
Total D1+D2+D3+D4+D5+D6+D7+D8+D9+D10+D11+D12:-
Cost of Ciivil work
Cost of Internal Public health services
Cost of Internal Electrical services
Total estimated cost in figures including Cultural Cess
Quoted Amount
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.34 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tendernotice_2.pdf
PDF • 2.49 MB
Tendernotice_3.pdf
PDF • 1.85 MB
Tendernotice_4.pdf
PDF • 13.41 MB
Tendernotice_5.pdf
PDF • 2.42 MB
Tendernotice_6.pdf
PDF • 5.19 MB
Tendernotice_7.pdf
PDF • 0.43 MB
BOQ_1.xls
Additional Documents • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .