Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.9 LAccepted-AOC DOOR NO 32 939C 1ST FLOOR CITY SCAPE BUILDING CHANGAMPUZHA NAGAR P O SOUTH KALAMASSERY ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | 1 | Accepted-AOC Lowest Rate | |
| 2 | 2₹14.7 L+₹80,418.40 (5.79%)Rejected-AOC | 2 | Rejected-AOC Higher Rate | |
| 3 | 3₹16.2 L+₹2.4 L (17.0%)Rejected-AOC 14 15 A CHANDU MASTER ROAD VISHNUPURAM CHERANALLOOR ERNAKULAM KERALA 682034 | ERNAKULAM | KERALA | 682034 | 3 | Rejected-AOC Higher Rate | |
| 4 | 4₹16.8 L+₹3.0 L (21.2%)Rejected-AOC | 4 | Rejected-AOC Higher Rate | |
| 5 | Rejected-Technical | - | Rejected-Technical not meeting eligibility criteria |
Tender Value
₹19.8 L
EMD Value
₹20,000
Closing Date
30 Dec 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager Products Dairy
Products Dairy Edapally ERCMPU LTD
Design, Supply, Installation, Testing, And Commissioning of Fire and Safety System at Products Dairy Edapally
2024_KCMMF_713389_1
EU/PD/ENGG/005/2024-25/5331
Open Tender
Miscellaneous Works
Turn-key
90 days
Products Dairy Edapally
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹20,000
Products Dairy Edapally
8 Apr 2025
6 Dec 2024
31 Dec 2024
6 Dec 2024
30 Dec 2024
6 Dec 2024
11 Dec 2024
TERRACE PUMP: Supply Installation, Testing and Commissioning Electrically driven Mono block Booster Pump having capacity of 900 LPM at 35 m head 50MWC with all the necessary accessories operating on 3 Ph. 50 Hz. 415 V AC supply including foundation bolts etc. complete, terrace pump 5 HP. Make:lubi
Automatic firepump panel with priventer with timer
ABOVE GROUND PIPING: Supply, erection, testing and commissioning of M.S 'B' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports. The pipe shall be painted with one coats of primer and two coats paint of Fire Red in color / shade. make: jindalstar
100 mm dia
80 mm dia
25 mm dia
UNDER GROUND PIPING: Supply, erection, testing and commissioning of M.S 'B' class Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as elbows, reducers, flanges etc. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports. The pipe shall be painted with one coats of primer and two coats paint of Fire Red in color / shade. make: jindalstar
100 mm dia
S I T C Hydrant Valve- Single Headed, S.S -as per IS: 5290 , ISI Marked oblique pattern Hydrant Landing valve with 80 mm dia flanged inlet and 63 mm dia instantaneous type female outlet complete with pvc blank cap & chain .
S I T C of Hose Box (cabinet) to accommodate one piece of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pie. The cabinet is made of MS/Fibre sheet with glass fronted hinged doors and lock.
S I T C of Fire Fighting Hose , Fire Hose - 63 mm ( 2 1/2") dia , 15 mtrs length bearing IS;636 type A with ISI Marked duly bounded with S.S couplings, 63 mm size, pair of male & female parts, instantaneous type , heavy duty bearing IS:903 with ISI mark.
S I T C of Branch Pipe- S.S 63 mm dia short size branch pipe with 20 mm dia bore nozzle , as per IS:903 with -ISI Marked
FIRE BRIGADE INLET 3 WAY: Supply,Installation, Testing and commissioning of Fire brigade connection comprising of 3 way inlets.
HOSE REEL: Supply, Installation, Testing and commissioning of Hydraulic hose reel complete with swing type, fitted with 20/19mm dia X 30 Mtr long, high pressure hose with 5mm outlet nozzle with shut off valve includes stop cock with all necessary fixing materials etc.
BUTTERFLY VALVE: Supply, Installation, Testing and Commissioning of Butterfly valves of following sizes with cast iron body flanges.
100 mm dia
NON RETURN VALVE: Supply, Installation, Testing and Commissioning of Non return valve of following sizes without bye pass arrangements swing check type with cast iron body and flanges.100 mm dia
BALL VALVE: Supply, Installation, Testing and commissioning of CI Ball valve 25mm
AIR RELEASE VALVE: Supply, Installation, Testing and commissioning of Air release valve 25 mm
PRESSURE SWITCH S I T C of having 1/4" BSP (F) connection IP:32 enclosure protection, pressure rage 0 to 200 psi with necessary contact
PRESSURE GAUGE S I T C of 4 " dial, 0 - 200 psi range 3/8" BSP weatehr proof with stainles steel internals, siphon tube inculding fittings etc.
S I T C of Manual Call Point breack glass type red colour powder coated MS/ABS box fix on existing wall /frame,24/12 Volt DC operated push OFF/ON switching mechanisem with inner, outer frame, operation label and necessary attachments
S I T C of Audio alarm hooter (sounder) powder coated MS/ABS box fix on existing wall/frame, 24/12 Volt DC operated siren circuit with diaphram speaker, maxium sound 60 db intensity under stautory with necessary attachments.
SITC of 1C x1.sq.mm Copper wire. ISI marked
S I T C of 20 mm dia medium grade rigid PVC conduit ISI mark with elbow, tees, jn:boxes, saddle clip and with necessary fittings.
S I T C of 6 zone Automatic Fire Alarm Control panel conventional type micro processor based control made of MS sheet cabinet the powder coated, audio and digitel visual display, circuit open short functions, test/evaqvation mode, silience and reset options, common and zone wise hooter supply outputs, fault and fire mode auxilary contacts with 24 DC volt out put zone circuits, operating 230 / 50 Hz AC volts.with 2nos battery.
Fire Alarm & Talk Back PA Panel- Supply, Installation, Testing and Commissioning of 6 Zone Fire Alarm 2 way talk back communication system With 60 watt Power Amplifier, conventional type, micro processor based control panel of MS cabinet powder coated audio and visual display with all necessary attachments, complete set.
Talk Back Unit-Supply, Installation, Testing and Commissioning of 6W wall mounted type Speakers with talk back facility, in CRCA sheet fabricated housing, complete with press to talk switch
FIRE EXTINGUISHER: Supplying, and fixing of Dry chemical powder type(ABC) fire extinguisher of 4 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683.-2006.
Supplying and installing in position LED "EXIT" sign boards of with battery backup.
Supplying and installing in position LED "Fire EXIT" sign boards of with battery backup.
SITC OF self glowing " FIRE DUCT" sign board of size 100mm x 300 mm made of luminescent safely, rigid sheet in green colour, photo luminescent rigid sheet with two each hanging chains & necessarry supports to hang it on ceiling.
Supply & installing in position laminated sheet of " FIRE EVACUATION PLAN " of suitable size fixed on wall & necessarry accessories to fix the plan on wall.
Documentation & Liasoning :- Preparation of Drawings /schemes/documents and getting final approval/sanction /NOC from statutory departments .viz Fire force department as per rules and regulations including arranging inspection and when required directed by the officals .( stautory fees if any will be borne by milma)
RAYAN FIRE PROTECTION SYSTEMS (BID ID -2020430)
COCHIN FIRE TECH INDIA PVT. LTD. (BID ID -2038692)
National fire safety systems thiruvalla (BID ID -2037336)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .