| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 CrAccepted-AOC 6TH FLOOR CG HOUSE DR ANNIE BESANT ROAD WORLI MUMBAI MAHARASHTRA 400030 | MUMBAI | MAHARASHTRA | 400030 | ₹1.8 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹2.4 Cr+₹57.5 L (31.7%)Rejected-AOC DOOR NO 48 50 PRAKASAM STREET SKCL HARMONY SQUARE T NAGAR T NAGAR CHENNAI TAMIL NADU 600017 | CHENNAI | TAMIL NADU | 600017 | ₹2.4 Cr+₹57.5 L (31.7%) | 2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 7 174 SAFVOLT KALAPATTI VIA VELLANAIPATTI COIMBATORE TAMIL NADU 641048 | COIMBATORE | TAMIL NADU | 641048 | - | - | Rejected-Technical Rejected as not satisfied all eligibility conditions |
Tender Value
₹2.0 Cr
EMD Value
₹2.0 L
Closing Date
28 Jan 2023, 5:00 pmClosed
Chief Engineer Transmission North
Office of The CE, Transmission (North), Kozhikode, Vydythi bhavanam, Kozhikode
Supply, Commissioning supervision and support of Indoor 11kV VCB 20 Panel set to be installed for 110kV GIS at 220kV Substation Shoranur with Bay control and Protection Unit (BCPU/IEDs) for integration with upstream substation automation system (SAS)
2022_KSEB_542466_1
CE/TRN/E5/25/2022-23
Open Tender
Equipments
Item Wise
150 days
CE TRANSMISSION NORTH
refer tender documents
5 documents required · 5 mandatory
₹29,500
Yes
₹2.0 L
Yes
Office of The CE, Transmission (North), Kozhikode
21 Jul 2023
22 Dec 2022
31 Jan 2023
23 Dec 2022
28 Jan 2023
23 Dec 2022
23 Dec 2022 - 26 Dec 2022
27 Dec 2022
Supply, Design, Documentation, Engineering, Manufacture, Inspection and testing, Packing at suppliers works, delivery at site, commissioning supervision & support for 11 kV Indoor VCB 20 Panel set with combinations of Incomer Feeder Panels (2 Nos), Outgoing Feeder Panels (17 Nos), Bus Coupler Panel with Bus Riser Panel, Neutral Current transformers(2Nos), Bay control and protection unit (BCPU) for all bays for integration with upstream Substation Automation System (SAS)with protection philosophy specified in the technical specification, along with supply of accessories necessary for operation and spares, to be installed for 110kV GIS at 220kV Substation Shoranur. Bus Bar Ratings are 2000A. Circuit Breakers shall be E2 M2 C1 Class as per IEC 62271- 200. Feeder panels and Incomer panels shall have Capacitive voltage Indicator (CVI) and Only Incomer panel BCPU’s will have PT inputs. Feeder and Incomer panels shall house one each Multifunction meter (MFM) and DLMS Compatible Energy meters. Items shall be engineered with necessary wiring and arrangements and so that each panel shall be assembled to meet the requirement as per schedule.The final Panel assembly meant for the station shall have provision for adding one more panel at each end, if required in future. The panel is intended for integrating with existing Substation Automation System (SAS) using BCPU in panels through HSR topology (IEC 61850 Rev 2 compliant).Including spares as per clause 37 of technical specification (CB Closing &Tripping coil -3 Sets each, CB Truck assembly complete for 2000A (incomer) - 1set, CB Truck assembly complete for 630A (outgoing feeder) - 2 set, Vacuum Interrupter Bottle -Incomer-2000A -1No, Vacuum Interrupter Bottle- Feeder- 630A- 2Nos, Supporting insulator for one pole - 1 set, CB Auxiliary contact- 1 set, BCPU with 3 O/C + E/F Relay with SEF, LBB Features (For Incomer) - 1 set, BCPU with 3 O/C + E/F Relay with SEF, LBB features.(For feeder) - 2 set, Master trip relay with Electrical reset - 3 Nos, Numerical High Impedance REF Relay - 1No, LED Indicating lamp with assembly- 3 sets, Multi-Function meter (MFM) - 3Nos, TOD Energy meter- 1No, Annunciator-1No, TTB -1No, CT suitable for Incomer panel - 3Nos, CT suitable for Outgoing panel- 3Nos, PT single pole with fuse- 3Nos, PT Fuse- 3Nos)
ABB INDIA LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
PDF • 0.05 MB
tech_eval.pdf
PDF • 0.91 MB
fin_bid_open.pdf
PDF • 0.08 MB
boq_comp_chart.xlsx
xlsx • 0.01 MB
fin_eval.pdf
PDF • 0.07 MB
aoc.pdf
PDF • 0.07 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .