Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC VILL PO KAMPA NEAR ASHRAM DIST NORTH 24 PGN KOLKATA WB | 24 PARAGANAS NORTH | WEST BENGAL | 743193 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹49.5 L+₹1.5 L (3.10%)Rejected-Finance NEAR MOHANPURA BALAJI ROAD TEH KISHANGARH RENWAL DIST JAIPUR 303603 | JAIPUR | RAJASTHAN | 303603 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹51.2 L+₹3.2 L (6.70%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹51.7 L+₹3.7 L (7.68%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹51.7 L+₹3.7 L (7.70%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
24 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata 700120
PROVN OF STORAGE TYPE WATER HEATER, TOILET AND BATHROOM AND SPL REPAIR TO BLDG NO NP-31 AND BLDG NO T-202 AT VARIOUS LOCATION AT KANCHRAPARA UNDER GE BARRACKPORE
2022_MES_559938_1
8717/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹94,600
Yes
21 Dec 2022
27 Oct 2022
26 Nov 2022
27 Oct 2022
24 Nov 2022
11 Nov 2022
Amount
PART-I Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down old unserviceable steel windows of any type completed all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Taking down chowkats or frame (without taking off shutter from the frames) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frame (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Dismantling of framed timber scantlings 40 sq cm and over in section, in any position complete all as specified and as directed.
Taking down of old unserviceable 15mm dia GI tubes complete all as specified and directed.
Taking down of old unserviceable 20mm dia GI tubes complete all as specified and directed.
Surface dressing in soft /loose soil not exceeding 15 cm deep complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for broken brick hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, fixing hold fast including necessary form work complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded stone aggregate) as in chajja etc complete all as specified and directed.
M&L PCC(1:3:6) type C2 (using 40mm graded broken stone aggregate) in foundations, filling and mass concrete, sub base of floor, complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) for fixing hold fast complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints etc complete all as specified and directed.
M&L for second class hard wood plain, framed, panelled shutters 35mm thick(any number of panels) with panels of tmber flat on both sides(feather edged), or of veneered particle board medium density, woold particle board with commercial face veneers: supplied and fitted to chowkats.
S&F of 35mm thick (factory made) second class hard wood glazed/ gauge & skeleton shutters for door & windows, open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing divided into square with plain, chamfered or rounded, fitted with cut & mitered rebated sash bars, any numbers for securing glass etc. sizes of members of shutters as specified in SSR Part-I, Section-8, Clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F of 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F of 150 mm long aluminium anodised extraded alloy handle, fabricated type complete all as specified and as directed.
S&F of 100 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F of 100 mm long aluminium anodised extraded alloy handle, fabricated type complete all as specified and as directed.
S&F of 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F of 75 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F in repairs of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F of 20mm dia harrison rails, mild steel, chromium plated fixed in brackets, stops, rollers etc. complete all as specified and directed.
S&F of 25mm dia MS powder coated bracket complete all as specified and directed.
S&F of 300mm long, MS ordinary rat tail rod pattern spring including roller & roller plate complete all as specified and directed.
S&F 100 mm size stainless steel butt hinges complete all as specified and directed.
Providing formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, including flat rough finished surfaces of concrete complete all as specified and directed.
Providing formwork to sides of pillars, posts, struts, piers, columns, and stanchions, square, rectangular or polygonal in shape, including flat rough finished sufaces fo concrete complete all as specified and directed.
Providing formwork to sides and soffits of floor and roof beams, beams hauncing, girders, bressummers, lintels and contilever, shelves including supports over hangs etc rough finished surfaces of concrete (flat) complete all as specified and directed.
Providing formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar works, flat rough finished surfaces of concrete ; not exceeding 200mm thick( horizontal or sloping) complete all as specified and directed.
Providing formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs exceeding 5 cm but not exceeding 20 cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exceeding 10cm but not exceeding 20 cm wide rough finshed surfaces of concrete complete all as specified and directed.
Providing formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Mild stell structural steel work incl tubular members conforming to Fe-410-S as in roof trusees(framed), struts, trussed purlins of beam, tee, angle, channel,tubes section including distance pieces cleats etc and cutting to dead ends, notching, drilling, fitting, riveting and/orwelding or connecting with bolts and nuts(including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gussets plates etc also for wedging truing up and fixing complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F of rolled mild steel roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F of pressed steel frames (factory made) for door of size 165mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded crushed stone aggregate) including one coat of red oxide zinc chrome primer (shop coat) to back of chowkats complete all as specified and directed.
S&F of steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded to receive wiremesh/glass complete all as specified and directed.
S&F of steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded to receive wiremesh/glass complete all as specified and directed.
Refixing old steel sections such as angle, flats etc in posts, strutsr,gates and similar works all as specified and as directed. (Note : Materials obtained from item No .7.00 here-in-before)
M&L for MS flat iron bent to shape, holes drilled etc complete as in hold fast, wind ties & for securing wiremesh of steel windows etc including one coat of red oxide paint and similar work conforming to Fe-290, Gde E-165 complete all as specified and directed.
S&F of steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form including taking down old unserviceable false ceiling complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
All as per item No. 70.00 but fixed as in skirting/dado etc. set and jointed in neat cement slurry and plointed in white or coloured cement to match in floor with 10 mm thick cement mortar (1:3) all as specified and directed.
M&L for 75mm thick, PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection path/hard standing finished cement concrete surfaces and smooth without using extra cement complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles (vertical) of size 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thick or equivalent set and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles as in skirting/dado/vertical wall over and including 10 mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) used as in plinth protection and paving 75 mm thick laid in slope finished even and fair complete all as specified and directed.
M&L for 20 mm thick granite slab (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the of granite stone including grinding and polishing over and including 15 mm thick screed bed of cement mortar (1:6) complete all as specified and directed.
M&L for 18mm to 20 mm thick granite slab (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the of granite stone including grinding and polishing and laid with 10 mm thick screed bed of cement mortar (1:3) on dado/skirting/vertical surface complete all as specified and directed.
M&L for rendering 15mm thick on top of RCC roof surfaces with cement mortar (1:3) mixing with mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 20mm thick in cement mortar (1:4) in two layers of 10mm each with using WPC @ 200ml per 50 Kg of cement or as per manufactors instruction in finishing layer on brick or concrete surfaces finished even & smooth (WPC for finishing layer will be paid seperately as "Supply only") complete all as specified and directed.
M&L for rendering 5mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistant primer on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on wall after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wallcare putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of steel surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after complete removal of oxisting paint including preparation of old steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over and including a coat of pink primer after preparation of new wooden surfaces of any description not exceeding 10 cm width or girth complete all as specified and directed.
M&L for preparation of old plastered surfaces and applying one coat of white wash on walls complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with one coat of creosote oil complete all as specified and directed.
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on ceiling surface including preparation of new plastered surface complete all as specified and directed.
S&F of 3mm thick sheet glass panes oridinary quality n.exc 0.5sqm each fixed to steel frame complete with oil putty in square/rectangular including steel pin.
S&F of 4.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 4mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane after acomplete all as specified and directed.
S&F of 15 mm bore stop valve/angular stop valve, fancy type, chromium plated , cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F of bib taps 15 mm bore cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Taking down old unserviceable 10 Ltrs capacity, PVC flushing cistern complete all as specified and directed.
S&F of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F of vitreous china wash basin, white, flat back, size 550 X 400 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F of fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F of 32mm dia waste coupling of PTMT (half and full threaded) (minimum weight 45 gms) for discharge pipe as completed all as per specified and directed.
S&F of 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall, ceilings or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
S&F of 15mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors/trenches etc (surface or concealed type) complete all as specified and directed.
S&F PVC connections 15 mm dia with PTMT nuts of length 600 mm complete all as specified and as directed.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 20mm dia ball valve high pressure of PTMT (minimum weight 210 gms) complete all as specified in SSR Part-I and directed.
S&F of 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection and 20mm dia PTMT ball valve including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor complete all as specified and directed.
M&L for PCC (1:3:4) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe 100 mm bore including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 100 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal with providing access door complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (double T) equal or unequal complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (double T) equal or unequal providing access door complete all as specified and directed.
M&L for 100mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F of 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) complete all as specified and directed.
S&F in repairs of vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor complete all as specified and directed.
S&F in repairs of sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F as in repairs of 32mm dia and 800mm long waste pipes for sink/wash/urinal hand basin complete as specified and directed.
S&F in repairs of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
PART-II Disconnecting the electrification and taking down old DBs( any type of vertical load line/TPN/SPN DBs) and making good to the disturbed surfaces to match the existing surfaces complete all as specified and directed. (Note: Temporary power supply shall be provided by the contractor)
Taking down unserviceable submain wiring aluminium/copper etc and making good the disturbed surfaces of walls/floor etc matching with the existing surface complete all as specified and directed. .
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.
Taking down carefully aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch.
One ceiling fan/exhaust fan point controlled by one switch.
One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board.
One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
Ditto-all as per Item No. 132.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed.
S&F of stepped type (0-4/5 step) electronic fan regulator 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F of bell push switch, single pole, one way, flush type, 5 Amps, 240 volts, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and 15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F of ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 for tubes /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of LED luminaire 600 mm x 600 mm, 35/36 watts, 220 Volts, AC, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size compete all as specified and directed. (Make- CG cat No. LCTLRNE-36-FO-CDL or equivalent of Havells/Bajaj/Philips or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way /L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC,SPN distribution board 4 way for flush mounting with 100 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 20 4 way /L&T Cat No. DBSPN004GDor equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F of MCCB, 63 Amps, 3 pole, 16KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz complete all as specified and directed.
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed.(Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 35 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable cable complete all as specified and directed.(NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for 50mm bore GI pipe (Light Grade) laid under road or fixed with pole/wall of culvert as in protection of UG cable incl necessary MS clamp complete all as specified and as directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 32 mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of 35/36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED/Philips Cat No. BRP052 LED 036 CW HP SLAF G SI PSU GR or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of ceiling fan of size 1200 mm sweep, high speed, single phase, 240Volts, AC, 50Hz, BEE 5 Star rated as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing after and including taking down of existing ceiling fan and deposit to MES store yard complete all as specified and directed. (Make:- Havells model No. Samraat or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
Supply, fixing and commissioning water heater storage type, eletric operated, capacity 50 Litres, BEE 5 Star rated, copper inner tank, complete with all connected accessories suitable for AC supply, 240 volts, 50 Hz including connecting with water supply pipe line and all water and electrical connection complete with necessary PVC connection pipe all as specified and directed.
S&F sheet metal enclosures with socket plug top single pole and neutral enslosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 Volts all as specified and as directed by EIC.
S&F of 20mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed complete all as specified and directed.
M&L cutting existing steel tubing for alternations or additions (Each cut measured) in 50 mm bore pipe line all as specified.
Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 mtr bellow the road surface) with help of GI tubing of any dia not exceeding 100 mm dia for passing for UG cable all as specified and directed. (GI pipe laid shall be measured seperately)
S&F of heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F of heavy duty type exhaust fans AC single phase 230/240 V of size 450 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 450mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F of water storage heater (geyser) of 25 ltrs capacity, vertical type with copper inner tank, 240 volts, BEE 5 Star rated, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos, hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing complete all as spcified and directed.
S&F of vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooing , IP-43 , TPN 4 way with 200 amps rated busbar, 440 volts, as per IS-8623 and making good the disturbed surface of wall and match with the existing surface compelte all as specified and as directed. ( Note- MCCB 3 pole 63 amps as main incomer will be measured and paid separately)
Supply, fixing and testing of Solar street light fitting all-in-one integrated type of 15 watts rating, LED type with solar panel of 30 watts, LED power 12 watts, Battery capacity-14AH, Lumen more than 1500 Lm, emitting colour cool white, 5700K with over charge device and backup for 08-10 hours of size 450mmX393mmX55mm complete fixed on wall/existing pole of max height 6m from ground level complete all as spcified and directed.
Taking down old unserviceable GI wire earthing complete all as specified and directed.
Taking down old unserviceable 50mm dia GI pipe complete all as specified and as directed.
Taking down old unserviceable GI bracket complete all as specified and as directed.
Taking down old unserviceable 35/36 Watt LED street light fitting complete all as specified and as directed.
Taking down old unserviceable sheet metal enclosure with socket plug top SPN type complete all as specified and as directed.
SHANKAR CONSTRUCTION CO
S S ENTERPRISE
Kiran Traders
M/S DEBAJIT BASU ROY CHOWDHURY
R.S. COMPANY
K. K. CONSTRUCTION
INDUSTRIAL CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .