Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC F 110 1ST FLOOR DDA BUILDING NO 5 JANAK PURI DISTT CENTRE JANAK PURI NEW DELHI WEST DELHI | ₹37.7 L Quoted ₹38.4 L | L1 | Accepted-AOC PO issued |
| 2 | L2₹40.1 L+₹1.7 L (4.41%)Rejected-Finance AMARA RAJA CAMPUS RENIGUNTA CUDDAPAH ROAD KARAKAMBADI CHITTOOR ANDHRA PRADESH 517520 | TIRUPATI | ANDHRA PRADESH | 517520 | ₹40.1 L+₹1.7 L (4.41%) | L2 | Rejected-Finance Higher rates |
| 3 | L3₹43.8 L+₹5.4 L (14.1%)Rejected-Finance 231 TRIBHUVAN COMPLEX MATHURA ROAD ISHWAR NAGAR SOUTH DELHI DELHI 110065 | SOUTH EAST DELHI | DELHI | 110065 | ₹43.8 L+₹5.4 L (14.1%) | L3 | Rejected-Finance Higher rates |
| 4 | L4₹48.8 L+₹10.4 L (27.2%)Rejected-Finance PLOT NO 101 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA 134113 | PANCHKULA | HARYANA | 134113 | ₹48.8 L+₹10.4 L (27.2%) | L4 | Rejected-Finance Higher rates |
| 5 | L5₹50.6 L+₹12.2 L (31.7%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹50.6 L+₹12.2 L (31.7%) | L5 | Rejected-Finance Higher rates |
| Sl No | Description | Qty | Unit | Volks Energie Private Limited L1 | AZURE MULTITRADE AND VANIJYA PVT LTD L3 | DESOLPOWER & SAFETY PRIVATE LIMITED L4 | Jupiter Electronics and Telecom Systems L5 | Amara Raja Energy & Mobility Limited L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply of Battery Bank for 2x130 KVA UPS system
Type : VRLA
Each cell voltage= 2V
Ampere rating of each cell = 850 AH
Total Battery Bank Voltage= 408 V
Ampere rating of Battery Bank: 850 AH
Minimum Number of cells per Bank: 204
Voltage limit of Inverter operation: 320V (Min voltage), 490V (Max voltage)
Absolute maximum voltage: 490 V
Float voltage per cell: 2.25V
Boost voltage per cell: 2.35V
Over all float voltage of Battery Bank = 459 V
Over all Boost voltage of Battery Bank: 480 V
DC Voltage stability: ±1V
Minimum DC Voltage per cell (ECV) = 1.75 V
Others details :-
1) The 408V, 830AH battery banks installed with 2x130 KVA Emerson make UPS system.
I) The bidder / supplier shall supply type tested battery as per IS:15549: 2004/IEC60896-21 & 22:2004 and IEC61427-2005. Over the range of at least 01 capacity per design and should have met requirement of service life test as per above stated IEC standards within last 7 yrs.
(Other detailed specifications/ technical data sheet /Standards as per Annexure I&II) | 2 | Sets | 26,59,486 ₹53,18,972 Lowest | 30,40,290 ₹60,80,580 | 31,51,024.8 ₹63,02,049.6 | 30,11,888.64 ₹60,23,777.28 | 28,54,337.4 ₹57,08,674.8 |
| 2.00 | Buyback of old battery bank already installed at DCRTPP, Yamuna nagar | 2 | Sets | 2,42,171.69 ₹4,84,343.38 Lowest | 9,20,754 ₹18,41,508 | 8,13,633.6 ₹16,27,267.2 | 11,22,000 ₹22,44,000 | 9,10,523.4 ₹18,21,046.8 |
| 3.00 | Supplier shall do Erection, Testing and Commissioning of New Battery Bank after dismantling of existing battery bank free of cost. Transportation of old dismantled battery bank either to store or out of DCRTPP shall be in the scope of firm.
Test shall be conducted in accordance with IEC60896-21&22: 2004. Other detail as per annexure attached.(Annexure-I&II)
Other important details:
1. Supply, Erection, Testing & Commissioning of battery bank at DCRTPP site will be in firm’s scope.
2. Manufacturing of battery bank should not be more than delivery period as per PO.
3. Supplier shall conduct Factory Acceptance Test (FAT) free of cost. FAT shall be carried out in presence of inspecting officer of DCRTPP. Supplier shall also conduct Site Acceptance Test (SAT) free of cost. Site Acceptance Test (SAT) will be carried out at site after final commissioning of battery bank at site.
4. Supplier shall provide Mounting Enclosures with base frames for proper fitment of battery bank free of cost.
5. Supplier shall have to dismantle the existing battery bank free of cost.
6. Supplier shall ensure and confirm inter-changeability of battery banks to be supplied with the existing battery bank at DCRTPP site. The supplier may visit DCRTPP site for visual survey of the existing battery banks before submission of bids, if required. In case any technical details of existing battery bank are required then please contact XEN/C&I-II: 9355061860.
7. All other accessories and miscellaneous items required for installation, commissioning and smooth functioning of battery banks shall also be in the scope of the supplier.
(Other detailed specifications/ technical data sheet /Standards as per Annexure I&II)
Note: Firm should quote their rates considering the buyback of old battery bank already installed at DCRTPP, Yamuna nagar. L-1 bidder will be decided on the basis of net price i.e. price of new battery bank supply+ Erection, Testing & Commissioning price -buyback price of existing battery bank. | 2 | Sets | 1,11,243.9 ₹2,22,487.8 | 70,800 ₹1,41,600 | 1,03,840 ₹2,07,680 | 29,500 ₹59,000 Lowest | 60,180 ₹1,20,360 |
Tender Value
Refer Docs
EMD Value
₹95,100
Closing Date
11 Nov 2025, 1:00 pmClosed
SE MM AND STORES
DCRTPP YAMUNA NAGAR
Supply of Battery bank with buy back of old battery bank installed at DCRTPP
2025_HBC_478698_1
POM-14256 Supply of Battery bank with buy back of old battery bank installed at DCRTPP
Open Tender
Miscellaneous Goods
Supply
90 days
DCRTPP YAMUNA NAGAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
₹95,100
Yes
18 May 2026
17 Oct 2025
14 Nov 2025
17 Oct 2025
11 Nov 2025
17 Oct 2025
Select, Excess (+), Less (-)
Tender Inviting Authority: < SE MM&STORE DCRTPP HPGCL YAMUNA NAGAR>
Name of Work: < Supply of Battery bank with buy back of old battery bank installed at DCRTPP>
Contract No: < POM-14256>
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Preferred make: EXIDE,AMARA RAJA,HBL or Equivalent Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Unit BASIC RATE In Figures To be entered by the Bidder in Rs. P Unit P&F Charges Amount in %age Unit GST Amount in %age Unit Freight Charges in %age inclusive of GST Unit Transit Insuranc in %age Any Other Duties/Levies in Rs. P IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Unit Rate With Taxes in Rs. P TOTAL AMOUNT With Taxes Rs. P TOTAL AMOUNT In Words
1 Supply of Battery Bank for 2x130 KVA UPS system Type : VRLA Each cell voltage= 2V Ampere rating of each cell = 850 AH Total Battery Bank Voltage= 408 V Ampere rating of Battery Bank: 850 AH Minimum Number of cells per Bank: 204 Voltage limit of Inverter operation: 320V (Min voltage), 490V (Max voltage) Absolute maximum voltage: 490 V Float voltage per cell: 2.25V Boost voltage per cell: 2.35V Over all float voltage of Battery Bank = 459 V Over all Boost voltage of Battery Bank: 480 V DC Voltage stability: ±1V Minimum DC Voltage per cell (ECV) = 1.75 V Others details :- 1) The 408V, 830AH battery banks installed with 2x130 KVA Emerson make UPS system. I) The bidder / supplier shall supply type tested battery as per IS:15549: 2004/IEC60896-21 & 22:2004 and IEC61427-2005. Over the range of at least 01 capacity per design and should have met requirement of service life test as per above stated IEC standards within last 7 yrs. (Other detailed specifications/ technical data sheet /Standards as per Annexure I&II) item1 2 Sets 0 Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
2 Buyback of old battery bank already installed at DCRTPP, Yamuna nagar item2 2 Sets 0 Full Conversion INR
3 Supplier shall do Erection, Testing and Commissioning of New Battery Bank after dismantling of existing battery bank free of cost. Transportation of old dismantled battery bank either to store or out of DCRTPP shall be in the scope of firm. Test shall be conducted in accordance with IEC60896-21&22: 2004. Other detail as per annexure attached.(Annexure-I&II) Other important details: 1. Supply, Erection, Testing & Commissioning of battery bank at DCRTPP site will be in firm’s scope. 2. Manufacturing of battery bank should not be more than delivery period as per PO. 3. Supplier shall conduct Factory Acceptance Test (FAT) free of cost. FAT shall be carried out in presence of inspecting officer of DCRTPP. Supplier shall also conduct Site Acceptance Test (SAT) free of cost. Site Acceptance Test (SAT) will be carried out at site after final commissioning of battery bank at site. 4. Supplier shall provide Mounting Enclosures with base frames for proper fitment of battery bank free of cost. 5. Supplier shall have to dismantle the existing battery bank free of cost. 6. Supplier shall ensure and confirm inter-changeability of battery banks to be supplied with the existing battery bank at DCRTPP site. The supplier may visit DCRTPP site for visual survey of the existing battery banks before submission of bids, if required. In case any technical details of existing battery bank are required then please contact XEN/C&I-II: 9355061860. 7. All other accessories and miscellaneous items required for installation, commissioning and smooth functioning of battery banks shall also be in the scope of the supplier. (Other detailed specifications/ technical data sheet /Standards as per Annexure I&II) Note: Firm should quote their rates considering the buyback of old battery bank already installed at DCRTPP, Yamuna nagar. L-1 bidder will be decided on the basis of net price i.e. price of new battery bank supply+ Erection, Testing & Commissioning price -buyback price of existing battery bank. item3 2 Sets 0 Full Conversion INR
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select %
Quoted Rate in Words
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.01 MB
BOQ_556666.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .