| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | ₹17.7 L Quoted ₹18.2 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹18.8 L+₹58,985 (3.25%)Rejected-Finance TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | ₹18.8 L+₹58,985 (3.25%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹20.0 L+₹1.8 L (9.97%)Rejected-Finance | ₹20.0 L+₹1.8 L (9.97%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹22.2 L+₹4.0 L (22.1%)Rejected-Finance | ₹22.2 L+₹4.0 L (22.1%) | L4 | Rejected-Finance Other than lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected due to requisite enlistment category not found in enlistment letter |
| Sl No | Description | Qty | Unit | KULBHUSHAN AGGARWAL L4 | M/S MALHI CONSTRUCTIONS L3 | VATANUCOOL ENGINEERS L2 | Akarsha Enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour in replacement of unserviceable hermitically sealed compressor of refrigerator 310/345/285 litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function.
Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting, Refrigerant charging etc complete with necessary guarantee period as per company terms and conditions. | 2 | Each | 9,800 ₹19,600 | 8,000 ₹16,000 Lowest | 11,400 ₹22,800 | 8,500 ₹17,000 |
| 2.00 | Material and labour in replacement of unserviceable hermitically sealed compressor of refrigerator 165/180/200/240/260 litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function.
Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting, Refrigerant charging etc complete with necessary guarantee period as per company terms and conditions. | 6 | Each | 8,800 ₹52,800 | 8,000 ₹48,000 Lowest | 9,500 ₹57,000 | 8,500 ₹51,000 |
| 3.00 | S&F in repairs relay suitable for upto 345 litres capacity refrigerator complete all as specified and directed. | 10 | Each | 2,000 ₹20,000 | 1,500 ₹15,000 | 950 ₹9,500 Lowest | 1,100 ₹11,000 |
| 4.00 | S&F in repairs thermostat automatic `R' frost with knob suitable for upto 345 litres capacity refrigerator complete all as specified and directed. | 12 | Each | 1,500 ₹18,000 | 1,500 ₹18,000 | 950 ₹11,400 | 450 ₹5,400 Lowest |
| 5.00 | S&F in repairs freezer assembly complete with screw, jointing of tubes etc. and testing of capacity upto 345 litres refrigerator of any make. | 10 | Each | 2,850 ₹28,500 | 2,000 ₹20,000 | 1,425 ₹14,250 | 400 ₹4,000 Lowest |
| 6.00 | S&F 15 watt lamp suitable for upto 345Ltr capacity refrigerator complete including taking down old unsv lamp with holder all as specified and directed. | 20 | Each | 80 ₹1,600 Lowest | 100 ₹2,000 | 95 ₹1,900 | 120 ₹2,400 |
| 7.00 | S&F in replacement of condenser coil unit with necessary fixing arrangements and testing suitable for upto 345 Liters capacity refrigerator complete all as specified and directed by Engineer-in-Charge. | 9 | Each | 1,650 ₹14,850 | 1,000 ₹9,000 | 1,425 ₹12,825 | 800 ₹7,200 Lowest |
| 8.00 | Material and labour, flushing out system , checking and rectification of leakages if any and make it serviceable with gas charging with refrigerant R-12/R-134A or as per actual requirement, oil charging complete in refrigerator of capacity upto 345 litres complete all as directed & with entire satisfaction of Engineer-in-Charge.Note:-Gas charging will be measure and paid under relevant item separately. | 14 | Each | 2,850 ₹39,900 | 2,000 ₹28,000 | 4,000 ₹56,000 | 1,000 ₹14,000 Lowest |
| 9.00 | Supply and charging of freon gas R-12 for refrigerator, deep freezer complete all as specified and directed. | 12 | Kgs | 2,850 ₹34,200 | 2,000 ₹24,000 | 3,000 ₹36,000 | 1,500 ₹18,000 Lowest |
| 10.00 | Supply and charging of freon gas R-22 for Air conditioner complete all as specified and directed. | 10 | Kgs | 2,850 ₹28,500 | 3,500 ₹35,000 | 2,375 ₹23,750 | 1,500 ₹15,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
11 Jul 2025, 6:00 pmClosed
Major S N Gaikwad
Holta Cantt Palampur
REPAIR AND MAINT OF COOLING APPLIANCES SUMMER APPLIANCES REFRIGERATION AC PLANT CONTROL PANEL AND MISC WORK AT PALAMPUR AND ALHILAL MIL STN
2025_MES_714298_1
GEP-30/2025-26
Open Tender
Civil Works
Item Rate
180 days
Palampur and Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
GE Palampur
₹40,000
18 Aug 2025
13 Jun 2025
17 Jul 2025
13 Jun 2025
11 Jul 2025
27 Jun 2025
Amount
Material and labour in replacement of unserviceable hermitically sealed compressor of refrigerator 310/345/285 litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting, Refrigerant charging etc complete with necessary guarantee period as per company terms and conditions.
Material and labour in replacement of unserviceable hermitically sealed compressor of refrigerator 165/180/200/240/260 litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting, Refrigerant charging etc complete with necessary guarantee period as per company terms and conditions.
S&F in repairs relay suitable for upto 345 litres capacity refrigerator complete all as specified and directed.
S&F in repairs thermostat automatic `R' frost with knob suitable for upto 345 litres capacity refrigerator complete all as specified and directed.
S&F in repairs freezer assembly complete with screw, jointing of tubes etc. and testing of capacity upto 345 litres refrigerator of any make.
S&F 15 watt lamp suitable for upto 345Ltr capacity refrigerator complete including taking down old unsv lamp with holder all as specified and directed.
S&F in replacement of condenser coil unit with necessary fixing arrangements and testing suitable for upto 345 Liters capacity refrigerator complete all as specified and directed by Engineer-in-Charge.
Material and labour, flushing out system , checking and rectification of leakages if any and make it serviceable with gas charging with refrigerant R-12/R-134A or as per actual requirement, oil charging complete in refrigerator of capacity upto 345 litres complete all as directed & with entire satisfaction of Engineer-in-Charge.Note:-Gas charging will be measure and paid under relevant item separately.
Supply and charging of freon gas R-12 for refrigerator, deep freezer complete all as specified and directed.
Supply and charging of freon gas R-22 for Air conditioner complete all as specified and directed.
Supply and charging of freon gas R-134A/410A for Air Conditioners or as per site requirement complete all as specified and directed.
S&F in replacement of door gasket of best quality suitable for up to 345 liters capacity refrigerator complete as per manufacturer's instruction and as directed by Engineer-in-Charge.
S&F in replacement of door handle of best quality suitable for up to 345 liters capacity refrigerator complete as per manufacturer's instruction and as directed by Engineer-in-Charge.
S&F in replacement of bottle self of best quality suitable for up to 345 liters capacity refrigerator complete as per manufacturer's instruction and as directed by Engineer-in-Charge.
S&F in replacement of vegatable tray of best quality suitable for up to 345 liters capacity refrigerator complete as per manufacturer's instruction and as directed by Engineer-in-Charge.
S&F in replacement of cabinate shelves of best quality suitable for up to345 liters capacity refrigerator complete as per manufacturer's instruction and as directed by Engineer-in-Charge.
S&F in replacement of crisper glass of best quality suitable for up to 345 liters capacity refrigerator complete as per manufacturer's instruction and as directed by Engineer-in-Charge.
S&F in replacement of door lock of best quality suitable for up to 345 liters capacity refrigerator complete as per manufacturer's instruction and as directed by Engineer-in-Charge.
Repair to unserviceable/burnt stablizer of 0.5KVA to 5 KVA capacity complete including replacement of knobs, rewinding of burnt transformer etc complete all as specified and directed. Note : The other item like time delay relay, over load relay etc shall be measured and paid seprately as supply only.
Supply only time delay relay 500 volts complete all as specified and directed.
Supply only over load relay 25-40 Amp complete all as specified and directed.
Material and labour for servicing of Split/Window/Tower type Ac unit (Inverter/Non Inverter type) of capacity 1.5/2.0/2.5 Ton including painting to outer cover and components with two coats of synthetic enameled paint of colour as directed complete including following:- (a) Cleaning and descaling of condensing unit and cooling coil with caustic soda mixed water and air blower and taking out all dirt /sludge etc. all as directed by EIC. (b) Greasing / oiling of blower and condensor fan motor. (c) Cleaning of indoor filters, indoor cooling coil, & condesor coil with water pressure pump.
Material and labour in replacement of unserviceable 5 Star Hermetically cut sealed compressor of Tower type ACs 2.5 TR capacity(Inverter/Non Inverter type) with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions
Material and labour in replacement of unserviceable 5 Star Hermetically cut sealed compressor of Split ACs 2.0 TR capacity (Inverter/Non Inverter type) with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions.
Material and labour in replacement of unserviceable 5 Star Hermetically cut sealed compressor of Split ACs 1.5 TR capacity (Inverter/Non Inverter type) with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions.
S&F in replacement to swing blade motor suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type.(Inverter/Non Inverter type) Note: Sample needs to be verified, before using at site.
S&F in replacement to Indoor AC Blower fan suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type(Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in replacement to Indoor AC Blower motor suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type (Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in replacement to Outdoor Fan motor suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type (Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in replacement to Outdoor Fan motor Capacitor suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type (Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in replacement to Indoor Cooling Coil suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type (Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in replacement to outdoor Condensor Coil suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type (Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in repair to AC Indoor unit Main Board (PCB Card) with display unit suitable for 1.5/2.0/2.5 TR Split AC/ Tower AC of any make and of any type (Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in replacement to AC Indoor unit Drain water pipe suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type, and also making good the entire surface as it was before doing job (Inverter/Non Inverter type). Note: Sample needs to be verified, before using at site.
S&F in replacement copper pipe of size 1/4 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete
S&F in replacement copper pipe of size 1/2 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete
S&F in replacement copper pipe of size 3/8 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete
S&F in replacement copper pipe of size 5/8 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete
S&F in repairs heating assy for Air Conditioner capacity 1.5/2.0/2.5 Ton (Inverter/Non Inverter type) complete all as specified and directed.
S&F in repairs indoor Air Filter for Air Conditioner of capacity 1.5/2.0/2.5 Ton (Inverter/Non Inverter type) complete all as specified and directed.
S&F in repairs running capacitor clip type of cap. 36 MFD, 240 volts 50 cycles for window type/Split type (Inverter/Non Inverter type) air conditioner 1.5 Ton capacity. Make:- Escop/Kell/Tesla/Sharda
S&F in repairs starting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for window type /Split type (Inverter/Non Inverter type) air conditioner 1.5 ton capacity. Make:- Kell/Tesla/Sharda/Epcos
S&F in repairs running capacitor clip type of cap. 45 MFD, 240 volts 50 cycles for Split /window type (Inverter/Non Inverter type) air conditioner 2 Ton Capacity.
S&F in repairs starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for window type/split type (Inverter/Non Inverter type) air conditioner 2 Ton capacity.
S&F in repairs capacitor 4 Mfd in split type AC (Inverter/Non Inverter type) complete all as specified and directed.
S&F in repairs capacitor 6 MFD in split type AC (Inverter/Non Inverter type) complete all as specified and directed.
S&F in repairs capacitor 2.5 MFD in split type AC (Inverter/Non Inverter type) complete all as specified and directed.
S&F in repairs valve of any size (1/2 ", 1/4 " 3/8" and 5/8 ") for split type of capacity 1.5/2/2.5 TR in split type AC(Inverter/Non Inverter type) complete all as specified and directed.
S&F in repairs thermostat switch suitable for 2 ton /1.5 ton capacity air Conditioner (Inverter/Non Inverter type) complete all as specified and directed.
S&F in repairs relay suitable for 1.5/2.0/2.5 ton capacity Air Conditioner (Inverter/Non Inverter type) as per sample complete all as specified & directed.
S&F in replacement of multi purpuse refrigerator base stand of best quality suitable for upto 345 Ltr complete all as specified and directed.
Supplying and re-charging of refrigerant Gas R-22 in AC Plant after detection of leakage & rectification of same in the system by using Carbon Di-oxide Gas and flushing the complete system thoroughly with Nitrogen gas, complete all as specified and directed by Engr-in-charge. Note:- (i) Gas shall be brought by the contractor at Site from authorized Dealer/Manufacturers in sealed cylinders of standard packings and re-filling shall be done in the presence of rep of Deptt. The empty cylinders after using the gas brought shall be returned to the contractor for payment purpose, only gas to the required extent used for charging shall be considered. (ii) The unit rate inserted is being to be inclusive of the cost of nitrogen gas used for leakage test and pressure test prior to filling/ charging of gas R-22
Supply and re charging compressor oil (Non-freezing) in AC plant, complete all as specified and directed by Engr-in-charge.
Descaling the condenser by recommended chemical cleaning agent by soaking method, disconnection condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line form both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4mm thick for following capacities of condensers suitable for AC plant capacities installed, complete all as specified and directed.
Descaling the Chiller by recommended chemical cleaning agent by soaking method, disconnection condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line form both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4mm thick for following capacities of condensers suitable for AC plant capacities installed, complete all as specified and directed.
Descaling the AHU Cooling Coil by recommended chemical cleaning agent by soaking method, disconnection condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line form both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4mm thick for following capacities of condensers suitable for AHU capacities installed, complete all as specified and directed.
Dismantling of worn out part of FRP cooling tower of capacity 60 TR, cleaning of water tanks and body of cooling tower to make the cooling tower functional and serviceable in all respect including rectification of minor leakages from the cooling tower with M Seal adhesive, complete all as specified and directed.
Supply & fixing side cover jalli for cooling tower for capacity 60 TR in replacement as per existing size and pattern, complete all as specified and directed.
Repair to heating unit of AC plant and change the burnt panel incl complete wiring and change the unserviceable power contactor, copper wore, Power relay, Phase indicator LED type lamp, amp meter, voltmeter and electric control panel complete.
Supply and fix top protector cover to the CT fan motor at the top of the cooling tower made of GI sheet 20 SWG, conical shape including flat iron of required size complete to protect the CT fan motor form rain water, complete all as specified and directed.
Supply & Fix metallic viscose fine filter in replacement made out of GI wire mesh interspaced with two crimp layers and three flat layers and housed in 2" deep metal frame efficiency 65% as per existing size and pattern for AC Plant air handling unit at signal centre complex, complete all as specified and directed.
Supply & Fix water pressure gauge 100 mm dia range 0-300 Lbs/Sq inch , complete all as specified and directed.
Supply & Fix Analoge Temp gauge range 0 -100 Degree centigrade, of dial dia 4inches, complete all as specified and directed.
Supply & Fix air grills made out of GI sheet as per existing size and pattern complete with necessary nuts, bolts, clamps and MS frame made out of angle iron of required size damper for opening and closing of grills, complete all as specified and directed.
Supply & Fix Cast iron butterfly valve of size 100 mm dia (ISI Mark), complete all as specified and directed.
Supply & Fix cast iron butterfly valve of size 80 mm dia (ISI Mark), complete all as specified and directed.
Supply & Fix cast iron balancing valve of size 80 mm dia (ISI Mark), complete all as specified and directed.
Supply & Fix cast iron 'Y' Strainer of size 80 mm dia (ISI Mark) complete all as specified and directed.
Supply and Fix in replacement 80mm, 3 Way motorised valve with actuator motor complete in all respect.
Supply & Fix bearing set (set of Bearings) (ISI Mark) for AC Plant of capacity 60 TR, complete all as specified and directed.
Supply & Fix gasket set for AC Plant, complete all as specified and directed.
Supply & Fix filter for AC Plant, complete all as specified and directed.
Supply & Fix power contactor of rating 25 amp 4 pole complete all as specified and directed.
Disconnecting electric connection of centrifugal pump set, 10 HP, electric dirven, three phase, 415 volts, and taking out from AC Plant transporting the same to work shop, dismentaling the pump set, re-winding the motor with suitable size of cooper enamalled wire, change the bearings , change of shaft if required, change the impalar if required etc, re-assembling the same transport from work shop to site, re-fixing in same position, making etecric connection and testing complete all as specified and directed. Note:- All defective parts deemed to be included in repair cost.
Disconnecting electric connection of monoblock pump set, 5 HP, electric dirven, three phase, 415 volts, and taking out from AC Plant transporting the same to work shop, dismentaling the pump set, re-winding the motor with suitable size of cooper enamelled wire, change the bearings , change of shaft if required, change the impalar if required etc, re-assembling the same transport from work shop to site, re-fixing in same position, making etecric connection and testing complete all as specified and directed. Note:- All defective parts deemed to be included in repair cost.
Supply only MCCB 415V, 36KA, 4 pole of rating 400A complete all as specified and directed. Make: L&T/Schinder/ABB etc
Supply and fix Air Curtain Motor of suitable capacity as per site reuirement and sample approved by GE
Repair/Replacement to Heating element of washing machine complete all as specified and directed by Engr-in-charge.
Disconnecting electric connection of washing machine Motor 3/5 HP, electric dirven, three phase, 415 volts, and taking out from Laundary plant transporting the same to work shop, re-winding the motor with suitable size of copper enamelled wire, change the bearings , change of shaft if required etc, re-assembling the same transport from work shop to site, re-fixing in same position, making elecric connection and testing complete all as specified and directed. Note:- All defective parts deemed to be included in repair cost.
M&L in replacement for water inlet control valve, as per sample approved, complete all as specified and directed.
M&L in replacement for Printed circuit board of washing machine , as per site requirement, complete all as specified and directed.
Material and labour for servicing of Laundary Plant of capacity 15/30 Kg including painting to outer cover and components with two coats of synthetic enameled paint of colour as directed complete including following:- (a) Cleaning and descaling of water pipeline network with caustic soda mixed water and air blower and taking out all dirt /sludge etc. all as directed by EIC. (b) Greasing / oiling of blower, rollers, motors, and all other connected items. (c) Cleaning of dryer, washer, dry tumbler and all other equipments. (d) Checking all wiring and rectifing any damage, if found. (e) Change the defective parts of Plant like Belt Pulley, Heating elements, Wiring PCB etc, if change during servicing then same shall be measured and paid separately.
M&L in replacement for Belt and Pulley set as per site requirement, and sample approved, complete all as specified and directed.
M&L in replacement for Drum Support Rollers set as per site requirement, and sample approved, complete all as specified and directed.
M&L in replacement for Blower fan as per site requirement, and sample approved, complete all as specified and directed.
Supply and Fixing DOL Starter suitable for electric driven three phase 3/5 HP motor complete as per site requiremennt and sample approved.
Supply and fixing in replacement sheet metal enclosures with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 32 Amps 240 Volts complete all as specified and directed.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 10 Sq mm for phase and neutral and one run of 10.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC concealed conduit/surface casing capping fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding. Note: Cutting chases on the wall whereever required is deemed to be included in unit rate quoted.
Dismantling, Refixing, Testing and commissioning of existing Split AC 1.5/2/2.5 ton including fastener, nut bolt, check nut & any minor accessories required for fixing the AC at required site , complete all as specified and directed by Engr-in-charge.
Note for item No 1 to 89 - (i) Contractor representative/engineer will report to office for morning and afternoon to collect routine/urgent nature of complaint related to Refrigeration and AC till completion of contract. The work shall be attended by the contractor/Rep immediately. The contractor will ensure deployed of sufficient manpower with equipped all sort of petty items such as Refrigerant, Gas for AC ,nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requisite T&P items to his tradesman. All routine / urgent job received on job slip will be prepaired and got signature of user's and will be deposited to concerned office within 24 hrs. In case of any delay in attending the complaint more than 12 hrs after handing over of routine / urgent works, the contractor shall be liable to pay the penalty as per the item rate. (ii) If the Contractor did not attend complaints, a penalty of Rs 500/- per day per complaint recovery shall be made from the work done amount. (iii) After any repair the site has to be cleaned and make the surface good.
Material and labour for Servicing of Compressor unit of central AC Plant including painting to outer cover and components with two coats of synthetic enameled paint of colour as directed complete including following:- (a) Cleaning/repair and greasing of compressor unit with recommended chemical cleaning agent and taking out all dirt /sludge etc. all as directed by EIC. (b) Cleaning of suction/discharge port incl servicing of lubrication system, cooling system and other sensor & safety devices etc.
VATANUCOOL ENGINEERS (BID ID -3344055)
M/S MALHI CONSTRUCTIONS (BID ID -3354399)
KULBHUSHAN AGGARWAL (BID ID -3350943)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .