| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC VILL KHARALALPARA P O P S DUDHNOI DIST GOALPARA ASSAM PIN 783124 | DUDHNOI | GOALPARA | ASSAM | 783124 | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.6 L+₹48.58 (<0.01%)Rejected-AOC VILL TILAPARA P O RANGALIKHATA DIST KOKRAJHAR | L2 | Rejected-AOC L2 | |
| 3 | L3₹48.6 L+₹95,258.99 (2.00%)Rejected-AOC ASSAM AS | KAMRUP | ASSAM | 781030 | L3 | Rejected-AOC L3 |
Tender Value
₹47.6 L
EMD Value
₹95,268
Closing Date
15 Jun 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Addl. Chief Engineer cum Director, PWD, BTC
The Addl. Chief Engineer cum Director, PWD, BTC, Kokrajhar.
Construction of Security Barrack at BTC Secretariat Complex, Kokrajhar.
2022_BTC_25811_1
ACE- 50/TECH/KOK(Bldg)/IFB/2016-17
Open Tender
Civil Works
Works
180 days
Kokrajhar
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹95,268
Yes
11 Jul 2022
2 Jun 2022
16 Jun 2022
2 Jun 2022
15 Jun 2022
2 Jun 2022
2 Jun 2022 - 15 Jun 2022
180 days
Amount
BARRACK 2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. 2.8.1 All kinds of soil.
4.1.6 1:3:6 (1 cement: 3 coarse sand (zone -III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources).
5.22 Steel reinforcement for R… Work including sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe 500D or more. 5.22.1 Mild steel and Medium Tensile steel bars.
5.9 Centering and shuttering including strutting, propping etc end removal of the same …. 5.9.1 Foundation Footing , base of column etc. For mass concrete. 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Posts & Strut.
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering , finishing and reinforcement - All work up to plinth level: 5.1.3 1:2:4 (1 cement :2 coarse sand (zone - III) derived from natural sources : 4 graded stone aggregate 20mm nominal size de rived from natural sources).
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses , fillets, columns pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement :1.5 coarse sand (zone -III)derived from natu ral sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand).
2.25 (a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete.
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level . 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand).
13.5 15 mm thick cement plaster in single coat on rough side of single or half brick wall 13.5.1. 1:4(1 Cement :4 Coarse Sand) c) In cement mortar 1:5
13.43 Applying one coat of water thinable cement primer of approved brand and manufacture on wall surface. 13.43.1.Water thinable cement primer.
13.44 Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1 New work (Two or More coat @ 3.84 Kg/10m2
9.5 Providing and fixing panelled or panelled and glazed shutters for door ,windows and clerestory windows , fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in -charge. (Note:- Butt hinges and necessary screws shall be paid separately). 9.5.2 Kiln seasoned and chemically treated hollock wood 9.5.2.2 30mm thick shutters.
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood
9.62 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 9.62.2 250x16 mm
9.63 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary 9.63.3 150x10 mm
9.66 Providing and fixing ISI marked oxidised M.S. handles conforming to IS: 4992 with necessary screws 100 mm.
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 50 mm dia
12.1 Providing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks , bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal /vertical or curved surfaces ), excluding the cost of purlins , rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00mm thick with zinc coating not less than 275 gm/m2
21.1 Providing and fixing aluminium work for doors, windows ,ventilators and partitions with extruded built up standard tubular sections /appropriate Z sections and other sections of approved make conforming to IS:733 and IS : 1285 , fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top , bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth , rust free , straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling C.P. brass/ stainless. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
12.26 Providing and fixing plain multipurpose cement board (Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperately ). 12.26.1 6mm thick cement fiber board as per IS: 14862.
9.117 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +- 1mm ),with wall thickness 2.0mm (+_ 0.2mm) , corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X19 mm and 1mm (+- 0.1 mm) wall thickness and 3 nos . stainless steel hinges fixed to the frame complete as per manufacture's specification and direction of Engineer-in-charge. 9.117.2 Extruded section profile size 42x50mm
9.118 30 mm thick factory made Polyviny1 Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30mm and wall thickness 2 mm (+- 0.2 mm), with inbuilt decorative moulding edging on one side . The styles and rails mitred and joint at the corners by means of M.S. galvanised /plastic brackets of size 75x220mm having wall thickness 1.0mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20mm and 1mm (+_ 0.1 mm ) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (+-0.2mm ) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S.'U' cleats The shutter frame filled with a uPVC multi- chambered single panel of size not less than 620mm, having over all thickness of 20mm and 1mm (+- 0.1mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacture's specification and direction of Engineer-in-charge.
17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. Flushing cistern, including flush pipe , with manually controlled device (handle level) conforming to IS: 7231, with all fitting and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
17.7 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.2 White Vittreous China Wash basin size 630x450mm with a single 15mm C.P. brass pillar tap.
17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I./PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I. clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required: 17.6.1 Single squatting plate with 5 litre P.V.C. automatic flushing cistern
11.44 Crazy ceramic tile flooring, with under layer 12mm thick cement mortar 1:4 (1 cement :4 coarse sand), with joints not exceeding 5mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm, mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge.
11.47 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shade except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3(1 cement :3 coarse sand)and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
18.7 Providing and fixing Chlorinated Polyviny1 Chloride (CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in Charge. 18.7.2 20mm nominal dia Pipes
18.15 Providing and fixing brass bib cock of approved quality: 18.15.2 20 mm nominal bore
18.16 Providing and fixing brass stop cock of approved quality: 18.16.2 20mm nominal bore
RCC STAGING 2.8 Earth work in excavation by mechanical means (Hydraulic excavator )/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ), including dressing of sides and ramming of bottoms, lift upto 1.5m , including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50 m. 2.8.1 All kinds of soil.
4.1.6 1:3:6 (1 Cement :3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources).
5.22 Steel reinforcement for R…. Work including sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level . 5.22.6. TMT bar fe 500D or more. 5.22.1 Mild steel and Medium Tensile steel bars.
5.9 Centering and shuttering including strutting, propping etc. and removal of the same …. 5.9.1. Foundation Footing, base of column etc.For mass concrete. 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Posts & Strut.
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.3 1:2:4 (1 cement :2 coarse sand (zone -III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de river from natural sources).
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1. 5:3 (1 cement : 1.5 coarse sand (zone -III) derived from natural sources : 3 graded stone aggragate 20 mm nominal size derived from natural sources).
10.2 Structural steel work riveted , bolted or welded in built up sections , trusses and framed work , including cutting , hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 50mm dia
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1 1.00 mm thick with zinc coating not less than 275 gm/m2.
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
18.7 Providing and fixing Chlorinated PolyvinyI Chloride (CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clams at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and tasting of joints complete as per direction of Engineer in Charge. 18.7.5 40mm nominal dia Pipes.
18.8 Providing and fixing Chlorinated Polyviny1 Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe withclams at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 18.8.1 15mm nominal dia Pipes.
SEPTIC TANK 2.8 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
4.1.6 1:3:6 (1 Cement : 3 coarse sand (zone -III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources).
5.22 Steel reinforcement for R…. Work including sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level . 5.22.6. TMT bar fe 500D or more. 5.22.1 Mild steel and Medium Tensile steel bars.
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.3 1:2:4 (1 cement :2 coarse sand (zone -III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size de rived from natural sources).
6.1 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in : 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand).
13.5 15 mm thick cement plaster in single coat on rough side of single or half brick wall 13.5.1. 1:4 (1 Cement :4 Coarse Sand) c) In cement mortar 1:5
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 19.32.1 With common burnt clay F.P.S. (non modular )bricks of class designation 7.5
EARTH WORK 2.25(a). Excavation, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 Km also including remming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
ELECTRICAL WORK 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.1. Group A
1.8.2 Group B
1.8.3 Group C
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.1 2 X 1.5 sq. mm +1 X 1.5 sq. mm earth wire.
1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
1.23 Supplying and fixing following piano type switch/socket on the existing switch box/cover including connections etc. as required. 1.23.1 5/6 amps switch.
1.23.4 3 pin 5/6 A socket outlet
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
127 Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.3 4 Module (125mmX75mm)
1.27.58 Module (125mmX125mm).
1.27.612 Module (200mmX150mm).
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34 Supplying and fixing brass batten/angle holder including connection etc. as required.
2.1 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling, holes in cubicle panel, making necessary connections, etc. as required. 2.1.2 63 A TP&N
2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.41:- 4 way (4 + 12), Double door
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1:- Single pole
2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2:- 63A
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1:- Upto 35 sq. mm
MR-1 Supplying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sq.mm, balance Aluminium strip, .................... 16 sq.mm 4 core U.G. Cable.
MR-2 Supplying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sq.mm, balance Aluminium strip, .................... 10 sq.mm 2 core U.G. Cable.
MR-3 Supplying with including fitting fixing of Ceiling fan etc. as directed by the Deptt. (USHA make 1200 mm sweep).
MR-4 Supplying with including fitting fixing of Exhaust Fan etc. as directed by the Deptt. (USHA make 300 mm sweep).
MR-5 Supplying including fitting fixing of Slim LED batten with polycarbonate round-shape diffuser. Grey end cap, housing is an ideal replacement solution for existing battens/fluorescent lamp with elegantly designed end caps etc. as required and directed by the deptt.
MR-6 Supplying with including fitting fixing of LED Bulb 8 Watt. Etc. as directed by the Deptt.
MR-7 Supplying with fitting and fixing of Motor Pumps set (Crompton/Kirlosjar/Usha or equivalent make) as required an directed by the department. (Crompton make 1HP, Model No. MINI CHAMP-I).
MR-8 Supplying including erection of 7.00 Mtr. G.I. Octagonal Pole with single arm bracket of required size along with fitting fixing, excavated work, foundation of bolts and nuts in RCC work in 1:3:6 proportion of 1.00 Mtr. Depth, Cement plastering etc. complete with all necessary materials as required and as specified by the Deptt. 7.00 Mtr. G.I. Octagonal Ple with Single arm bracket.
MR-9 Supplying with fitting fixing of 90 W Hight efficiency IP66 streetlight with high power LED having aluminium pressure dia-cast housing and PC cover in the front and lens for batwing light distribution. (Orient/Bajaj/Havells/Philips Make) etc.
SWRANG NARZARY
Jamidar Narzary
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .