Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE BARRACKPORE
Office of the GE BARRACKPORE, KOLKATA - 700120
REPAIR/MAINT OF BLDG SECURITY LIGHTS AND AREA LIGHTING, STREETS, GARDEN LIGHTS AND GATE LIGHTS AT BARRACKPORE CANTT UNDER GE BARRACKPORE
2026_MES_798792_1
8308/E8
Open Tender
Civil Works
Item Rate
180 days
BARRACKPORE
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹500
GE BARRACKPORE
₹70,000
Yes
14 Nov 2026
14 Nov 2026
7 Dec 2026
14 Nov 2026
5 Dec 2026
28 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F LED street light/Building seciurity light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed.
Note- For item No 1 to 8, Necessary T&P item required at site for repair of Street Light/High Mast light fittings is deemed to be included in quoted rate. | 25 | Each | - | - |
| 2 | S&F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 5400 lm and system wattage not less than 45W with a nominal system efficacy of 120 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed. | 20 | Each | - | - |
| 3 | S&F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 7200 lm and system wattage not less than 60W with a nominal system efficacy of 120 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed. | 25 | Each | - | - |
| 4 | S&F LED street light fitting of high-quality group control enabled integrated LED Street Light with a minimum system lumen of min 10800 lm and system wattage not less than 90W with a nominal system efficacy of 120 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed. | 30 | Each | - | - |
| 5 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 8400 lumens and minimum system wattage of 70 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it's driver both should be BIS registered with ab warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting upto 12 metre height from the normal ground level complete all as specified and as directed. | 15 | Each | - | - |
| 6 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 12000 lumens and minimum system wattage of 100 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it's driver both should be BIS registered with ab warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting from High mast pole upto 20 metre height from the normal ground level complete all as specified and as directed. | 5 | Each | - | - |
| 7 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 14500 lumens and minimum system wattage of 120 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it's driver both should be BIS registered with a warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting from High mast pole upto 20 metre height from the normal ground level complete all as specified and as directed. | 11 | Each | - | - |
| 8 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 25000 lumens and minimum system wattage of 200 Watts/210Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it's driver both should be BIS registered with a warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fitting upto 12 metre height from the normal ground level complete all as specified and as directed. | 18 | Each | - | - |
| 9 | S&F New generation LED post top lantern, 15/20 Watts, 230 Volts, AC outdoor type with decorative post top for 360 degree indirect lighting IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical accessories including taking down old unserviceable post top light fitting complete all as specified and as directed. | 15 | Each | - | - |
| 10 | S&F New generation LED post top lantern, 35/40 Watts, 230 Volts, AC outdoor type with decorative post top for 360 degree indirect lighting IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical accessories including taking down old unserviceable post top light fitting complete all as specified and as directed. | 19 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_896129.xls
BOQ • 0.53 MB
Tenderdoc_8308.pdf
Tender Documents • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .