Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAdmitted-Finance PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | ₹25.2 L | L1 | Admitted-Finance |
| 2 | L2₹25.6 LAdmitted-Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | ₹25.6 L | L2 | Admitted-Finance |
| 3 | L3₹29.6 LAdmitted-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹29.6 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | m/s prakash enterprise L1 | OM ENTERPRISE L2 | SURESH ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for servicing of Window AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the Air conditioner fully functional & serviceable complete all as specified & directed by Engineer-in-Charge. | 15 | Each Job | 2,400 ₹36,000 | 2,570 ₹38,550 | 10,100 ₹1,51,500 |
| 2.00 | M&L for servicing of split AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 100 | Each Job | 3,000 ₹3,00,000 | 3,250 ₹3,25,000 | 5,000 ₹5,00,000 |
| 3.00 | M&L for servicing of split AC's of 2.0 Tonne capacity of any make , complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 50 | Each Job | 3,000 ₹1,50,000 | 3,690 ₹1,84,500 | 7,000 ₹3,50,000 |
| 4.00 | M&L for servicing of Cassette AC's of capacity 2.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | 6,199 ₹12,398 | 6,180 ₹12,360 | 8,500 ₹17,000 |
| 5.00 | M&L for servicing of Cassette AC's of capacity 3.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | 6,599 ₹13,198 | 6,580 ₹13,160 | 20,000 ₹40,000 |
| 5.01Note for item no 1 to 5:- (a) The above item includes labour charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints for a period of one year c) Preventive Maintenance 3 visit in a year (qtrly based ) to carry out 2 dry & 1 wet serivice from Local Authorised Service Centre as approved by GE (b) The cost of spares such as Fan Motor/Louver Motor/ Gas Charging/ Capacitors & Relay/Thermostat Switch / Selector Switch / Air Filter / Remote Control / Fan & Blower / Evaporator and Condenser coil / Air Deflector / louvers/compressor will be measured & paid separately under relevant item of the schedule. | ||||||
| 6.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the window type air conditioner of 1.5 Ton capacity complete all as specified and directed. | 5 | Each Job | 2,775 ₹13,875 | 2,770 ₹13,850 | 1,500 ₹7,500 |
| 7.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner upto 1.5 Ton capacity complete all as specified and directed. | 50 | Each Job | 2,905 ₹1,45,250 | 2,900 ₹1,45,000 | 1,600 ₹80,000 |
| 8.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner of 2.0 Ton capacity complete all as specified and directed. | 20 | Each Job | 3,395 ₹67,900 | 3,390 ₹67,800 | 2,000 ₹40,000 |
| 9.00 | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 2 Ton capacity complete all as specified and directed. | 2 | Each Job | 1,050 ₹2,100 | 1,050 ₹2,100 | 2,100 ₹4,200 |
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
2 Jul 2026, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
REPAIR AND MAINT OF CERTAIN COOLING AND REFRIGERATION APPLIANCES AND ALLIED WORK AT VARIOUS LOCATIONS OF NAVAL STATIONS
2026_MES_762242_2
9372/PBR/E8
Open Tender
Electrical and Maintenance Works
180 days
GE Navy Porbandar
Please see tender documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹52,000
Yes
3 Jul 2026
11 Jun 2026
3 Jul 2026
11 Jun 2026
2 Jul 2026
19 Jun 2026
11 Jun 2026 - 18 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for servicing of Window AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the Air conditioner fully functional & serviceable complete all as specified & directed by Engineer-in-Charge. | 15 | Each Job | - | - |
| - | M&L for servicing of split AC's upto 1.50 Tonne capacity of any make, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 100 | Each Job | - | - |
| - | M&L for servicing of split AC's of 2.0 Tonne capacity of any make , complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 50 | Each Job | - | - |
| - | M&L for servicing of Cassette AC's of capacity 2.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | - | - |
| - | M&L for servicing of Cassette AC's of capacity 3.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet service by removing dust with blower, complete cleaning of outer & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. | 2 | Each Job | - | - |
| - | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the window type air conditioner of 1.5 Ton capacity complete all as specified and directed. | 5 | Each Job | - | - |
| - | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner upto 1.5 Ton capacity complete all as specified and directed. | 50 | Each Job | - | - |
| - | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the split type air conditioner of 2.0 Ton capacity complete all as specified and directed. | 20 | Each Job | - | - |
| - | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 2 Ton capacity complete all as specified and directed. | 2 | Each Job | - | - |
| - | Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 3 Ton capacity complete all as specified and directed. | 3 | Each Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_864032.xls
BOQ • 0.42 MB
9372_GenPage.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid