Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance VEER KUNWAR SINGH COLONY BEHIND QTR NO H 150 HINNO RANCHI 834002 | RANCHI | JHARKHAND | 834002 | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.9 Cr+₹4.0 L (2.18%)Admitted-Finance 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹1.9 Cr+₹4.0 L (2.18%) | L2 | Admitted-Finance |
| 3 | L3₹2.0 Cr+₹12.1 L (6.60%)Admitted-Finance | ₹2.0 Cr+₹12.1 L (6.60%) | L3 | Admitted-Finance |
| 4 | L4₹2.0 Cr+₹16.1 L (8.76%)Admitted-Finance | ₹2.0 Cr+₹16.1 L (8.76%) | L4 | Admitted-Finance |
| 5 | L5₹2.2 Cr+₹31.8 L (17.4%)Admitted-Finance | ₹2.2 Cr+₹31.8 L (17.4%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S AMAR ENTERPRISES L1 | Sterling And Wilson Pvt. Ltd L2 | JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED L3 | ABHISHEK ASSOCIATES L4 | PAN POLAR ENGINEERS PVT. LTD. L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Sub Head - I Operation and Maintenance - Man power Requirement. Providing Operation and Maintenance Services of Electrical & Mechanical Installations monthly at entire Operational Area includes Old & New ATC cum Technical Block, Fire station, Navaids, STP building, Hangars (For availing source of power supply only) comprising GLF Systems, CCRs, 03 nos. DG Sets upto 500 KVA with AMF Panels, Power Supply Distribution Systems, Transformers upto 630 KVA, Water Pump Sets, Lifts, High Mast Towers, Flood Lights, Street Lights, Perimeter Road Lights , Fire Hydrant System (only operations), HVAC-VRV system (only operations) all Internal & External E. I. works, Old & New ATC power houses, Fire station, i/c 33 KV HT panel, all LT panels & Feeder pillars, APFC panel, ALCMS, UPSs (2 nos x80 KVA and 2 nos x180 KVA) including other minor ancillary & related installations covering the scope of operations, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satifactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintenance of records/documentation etc. as per scope of work given in special conditions and technical specifications of contract on all days including Sundays & Holidays. The services of DG Sets, AMF Panels at power houses and the services of all other E & M installations shall be ensured round the clock (ie. in three shifts daily, each shift of 8 hours) as per specification and as required. (Minimum Manpower engaged shall be as per special condition of contract and particular specification of contracts) | ||||||||
| 1.01 | Ist Year | 12 | Month | - | - | - | - | - |
| 1.02 | II nd Year | 12 | Month | - | - | - | - | - |
| 2.00Sub Head - 2 Miscellanious seruices Testing BDV value of transformer oil in presence of AAI representative | ||||||||
| 2.01 | Ist Year | 5 | each | - | - | - | - | - |
| 2.02 | II nd Year | 5 | each | - | - | - | - | - |
| 3.00Dehyderation and filtration of transformer oil at site including testing for BDV value after dehydration and filtration and submission of test reports etc. complete as required. | ||||||||
| 3.01 | Ist Year | 3,000 | ltrs | - | - | - | - | - |
| 3.02 | II nd Year | 3,000 | ltrs | - | - | - | - | - |
| 4.00Servicing, maintenance and testing of L & T make Air Circuit Breaker up tol000A complete as required. | ||||||||
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
15 Jun 2020, 3:00 pmClosed
AGM(EE)
AAI,BM,Airport,Ranchi
ARMO E and M Installations at B. M. Airport, Ranchi SH Providing Maintenance Services for E and M Installations of Operational Area and Technical Block for the Year 2020-2022
2020_AAI_49759_1
AAI/RNC/ENGG(E)/ARMOOPRTB
Open Tender
AMC/ Maintenance Contracts
Works
730 days
AAI, BM, Airport
Please refer tender document
3 documents required · 3 mandatory
₹1,180
Yes
Airports Authority of India
₹4.5 L
Yes
27 Jun 2020
4 Jun 2020
22 Jun 2020
4 Jun 2020
15 Jun 2020
4 Jun 2020
4 Jun 2020 - 10 Jun 2020
Amount
Sub Head - I Operation and Maintenance - Man power Requirement. Providing Operation and Maintenance Services of Electrical & Mechanical Installations monthly at entire Operational Area includes Old & New ATC cum Technical Block, Fire station, Navaids, STP building, Hangars (For availing source of power supply only) comprising GLF Systems, CCRs, 03 nos. DG Sets upto 500 KVA with AMF Panels, Power Supply Distribution Systems, Transformers upto 630 KVA, Water Pump Sets, Lifts, High Mast Towers, Flood Lights, Street Lights, Perimeter Road Lights , Fire Hydrant System (only operations), HVAC-VRV system (only operations) all Internal & External E. I. works, Old & New ATC power houses, Fire station, i/c 33 KV HT panel, all LT panels & Feeder pillars, APFC panel, ALCMS, UPSs (2 nos x80 KVA and 2 nos x180 KVA) including other minor ancillary & related installations covering the scope of operations, repairs & maintenance, attending faults / breakdowns rectifications, ensuring serviceability / satifactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, maintenance of records/documentation etc. as per scope of work given in special conditions and technical specifications of contract on all days including Sundays & Holidays. The services of DG Sets, AMF Panels at power houses and the services of all other E & M installations shall be ensured round the clock (ie. in three shifts daily, each shift of 8 hours) as per specification and as required. (Minimum Manpower engaged shall be as per special condition of contract and particular specification of contracts)
Ist Year
II nd Year
Sub Head - 2 Miscellanious seruices Testing BDV value of transformer oil in presence of AAI representative
Ist Year
II nd Year
Dehyderation and filtration of transformer oil at site including testing for BDV value after dehydration and filtration and submission of test reports etc. complete as required.
Ist Year
II nd Year
Servicing, maintenance and testing of L & T make Air Circuit Breaker up tol000A complete as required.
Ist Year
II nd Year
Servrcing, maintenance and calibration of earth fault and over load relay with secondary injection kit etc. of 02 nos. HT panel of Jyoti make comDlete as required.
Ist Year
II nd Year
Servicing, maintenance and testing of 33 kV HT - Vaccum Circuit Breaker ofjyoti make etc. complete as required.
Ist Year
II nd Year
Repair and rewinding of submersible pump motor upto 5 HP Job includes transportation of motor, dismantling and rewinding with the same gauge insulated copper wire including replacement of all the internal worn-out/ defective parts i.e. bushes, impellers, sleeves, upper and lower bush sets, thrust bearings, oil seals, rotor grinding and balancing , assembling, testing, transportation etc. complete as required.
Lifting and lowering of submersible pumps of various capacities (upto 5 HP) due to defect in existing pump on urgent basis within a short notice including connection of cable, jointing of cable etc with successful testing & commissioning complete as required.
Repair and overhauling of AMF panels i/c Checking of control circuits, interlocking , checking of healthiness of all components including AMF Relays etc as complete and as per direction of EIC(Faulty spares to be provided by AAI )
Sub Head - 3 Supply of general electrical Materials as and when required. Supply of Flame Retardant Low Smoke & Halogen FR-LSH PVC Insulated Industrial Cables of following sizes Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts Conforming to IS: 694 (Each Roll of 90 Mtrs)
I Core 1.5 Sq. mm.
I core2.5 sq.mm.
I core 4 sq.mm.
Supply of PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 (Each Roll of 100 Mtrs)
3 core 2.5 sq.mm.
3 core 4 sq.mm.
Supply of 90 W LED street Light fittings cool white
Supply of 3HP submersible pump set make KSB, model UMAI 100- 2.2122 or equivalent
supply of wll mounted fans 300 mm sweep
supply of medium intensity Aviation obstruction light for 230 V system
Supply of following size XLPE insulated and PVC sheatheed, armoured Aluminum conductor power cable of 1.1 KV grade conforming to IS-7098 (part-1) 1988 with upto date amendments. 3.5 x 185sq mm
12V constant voltage converter drive for LED signages 60W
12V constant voltage converter drive for LED signages 120W
LED strip 0.2W X 144 per strip of I meter
SH:4 supply of Airfield materials i/c GLF Supply of following GLF items as per latest ICAO specifications
200w 6.6 A holagen Lamp Runway lamp
105 w 6.6 A BIPIN (Inset ) Halogen Lamp
200 W 6.6 A Elevated Approach Fiting lamp
Runway Larnp Holder (Flate end tenninal )
6 sq.mm ESSNA -kit (copper ) 5kv grade
16 sq.mm 5 KV Grade plug &Recaptable (ESSNA Kit)(copper)
Secondary 2 Pin lead of 0.3 mtr Length
Two Pin Secondary Plug Assembly for PAPI (2.5 Mtr long)
Base Plate Gaskets
LED Signage Converter capable to drive LED strip of 0'5w for ooerational area signages
LED Signage Strip of 0.5w make osram or equivalent
LED Type Taxi Fitting as per latest ICAO standards
breakable coupling for GLF light fittings
Supply of SCR /Thyrister for NASU CCR
85 RK 160 SCR/thyrister for 7.5kw NASU make CCR
250RK 160 SCR/thyristor for 30kw NASU make CCR
Supply of Isolating Transformer as per ICAO
Isolating Transformer200w 20/6.6 A
Isolating Transformer200w 6.6/6.6 A
Isolating Transformer 45w 20/6.6 A
Isolating Transformer 45w 6.6/6.6 A
Isolating Transformer 15 w 20/6.6A
Isolating Transformer 15 w 6.6/6.6A
Isolating Transformer 300W 6.6/6.6A
Supply of LENS
360 Clear inner lens /Filters
180 deg inner lens filters
180 deg Red lens filters
180 deg Green lens filters
180 deg yellow lens/filter
Ommi- directionol blue lens Suitable for MIRL
180 deg Black Sheild
180 Yellow Filter (convetional Type )
Red Filter for papi
Red Spreader lens for end light fiting
Green Spreader lens For threshold light fiting
360 Clear outer dome for HIRL fitring
Supply of Airfield/Runway Cable
1x6 sq.mm Airfiled Lieilrting cable
1x16 sq.mm Airfiled Lieilrting cable
Sub Head - 5 DSR Works Percentage above or below on the rates of DSR'2018(CPWD )-Electrical items worth totaling to Rs.15,00,000.00 as per requirement. (Note: The firm has to quote/upload the Percentage above/ below (+/- %) on the quantity mentioned against this item directly in the form of multiplying factor in the rate coloumn as clarified below: For Example: If desired to quote 5% above on SR-2018 rates, the rate column shall be filled as 1.05. If desired to quote 3% below on SR-2018 rates, the rate column shall be filled as 0.97.)
Sterling And Wilson Pvt. Ltd
JATINDER CONSTRUCTION COMPANY PRIVATE LIMITED
ABHISHEK ASSOCIATES
PAN POLAR ENGINEERS PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
armoopertbtenderdocument.pdf
Tender Documents • 4.68 MB
BOQ_53490.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .