Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC 18 398 MUNDAKAYAM MUNDAKKAYAM 964 IDUKKI KERALA 686513 | KOTTAYAM | KERALA | 686513 | ₹6.3 L | L1 | Accepted-AOC L1 Accepted for further proceedings |
| 2 | L2₹6.3 LRejected-Finance 3 PULIKKOTTIL ARCADE PRIVATE LIMITED ROAD NEAR KALAMASSERY EMAKULAM 682021 | EMAKULAM | ERNAKULAM | KERALA | 682021 | ₹6.3 L | L2 | Rejected-Finance L2 |
| 3 | L3₹7.2 LRejected-Finance F O ASSOCIATES LAND MARK CENTRE NEAR BUS STAND KASARAGOD | KASARAGOD | KASARAGOD | KERALA | ₹7.2 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | KALLOOR ELECTRONICS AND LIGHTING PVT LTD L1 | MOHAMMED FAISAL K L3 | Lanoviz Security Solutions Private Limited L2 |
|---|---|---|---|---|---|---|
| 1.00CIVIL WORKS- 8 Mtr Octagaonal Mini Mast | ||||||
| 1.01 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 5.6 | cum | 359.72 ₹2,014.43 | 415.7 ₹2,327.90 | 359.72 ₹2,014.43 |
| 1.02 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 0.4 | cum | 7,932.89 ₹3,173.16 | 9,167.33 ₹3,666.93 | 7,932.89 ₹3,173.16 |
| 1.03 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete | 14.56 | sqm | 386.16 ₹5,622.49 | 446.25 ₹6,497.40 | 386.16 ₹5,622.49 |
| 1.04 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 111.27 | kilogram | 112.43 ₹12,509.97 | 129.93 ₹14,456.63 | 112.43 ₹12,509.97 |
| 1.05 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 2.09 | cum | 10,488.77 ₹21,879.57 | 12,120.93 ₹25,284.25 | 10,488.77 ₹21,879.57 |
| 1.06 | 13.1.1 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand) | 3.85 | sqm | 369.76 ₹1,423.58 | 427.3 ₹1,645.10 | 369.76 ₹1,423.58 |
| 1.07 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 3.48 | cum | 318.47 ₹1,107.32 | 368.03 ₹1,279.63 | 318.47 ₹1,107.32 |
| 1.08 | OD243551/2025-2026 Fabrication, supply, conveyance and installation of ACP sheet name board indicating the cost involved, the commencement, completion and inauguration date etc. | 1.6 | sqm | 2,234.73 ₹3,575.57 | 2,582.48 ₹4,131.96 | 2,234.73 ₹3,575.57 |
| 2.00ELECTRICAL WORKS-8 Mtr Octagaonal Mini Mast | ||||||
Tender Value
₹6.3 L
EMD Value
₹15,673
Closing Date
26 Jan 2026, 3:00 pmClosed
Assistant Manager (PED)
STEEL INDUSTRIALS KERALA LTD.ATHANI P.O,THRISSUR- 680 581
S and I of 4 No. of 8 Mtr Octagonal Mini Mast system with 3 x 100W LED Flood Lights and 2 Nos. of 8 Mtr Tubular Mini Mast systems with 3 x 100W LED Flood Lights at various locations in Thiruvilwamala GP, Thrissur Dist Annual Pj 2025-26, Pj No.106/26
2026_SILK_826881_2
SILK/PED/S-195/2025-26/2974
Open Tender
Miscellaneous Works
120 days
Thiruvilwamala
As per the tender documents
6 documents required · 6 mandatory
₹1,478
₹15,673
Yes
31 Mar 2026
19 Jan 2026
27 Jan 2026
19 Jan 2026
26 Jan 2026
19 Jan 2026
19 Jan 2026 - 26 Jan 2026
CIVIL WORKS- 8 Mtr Octagaonal Mini Mast
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
13.1.1 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
ELECTRICAL WORKS-8 Mtr Octagaonal Mini Mast
90.15.1.1 Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.7 Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.14.1.2 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
OD243562/2025-2026 Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a 25A/1.5HP capacity. It features 5 On/Off program settings for daily and weekly schedules, along with manual start, ON delay, and OFF delay settings. Equipped with a high-precision, industrial-grade chip and strong anti-interference capabilities, the timer can automatically turn on and off the power supply of various electrical equipment according to the time set by the user. The controlled objects can include street lights, light boxes, neon lights, and high/mini mast systems. It also includes a sufficient battery backup for time memory in case of power failure, and comes with suitable fittings for use in a distribution box or MV panel with FRLS PVC insulated 1.5 mm single core cable suitable for control wiring towards contactor
OD243559/2025-2026 Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC, 50Hz operation. It can control street lights, light boxes, neon lights, high/mini mast systems, and induction loads.
OD243560/2025-2026 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 2.5 sq. mm
OD243561/2025-2026 Supply and installation of an IP20 Surge Protective Device (SPD) with suitable fittings for a distribution box or MV panel. Specifications include: Voltage Protection Level (Up), Nominal Voltage: 230V, UOC: 10kV, L-N: 7kV, L-PE: 7kV, N-PE: 7kV, Nominal Discharge Current (8/20µs): 10kA, Total Discharge Current (8/20µs): 60kA, Response Time: <35 ns, Ambient Temperature (Ta): -10 to 55°C.
OD243564/2025-2026 Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2- way neutral links mounted on DMC/SMC base.
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.3 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD243563/2025-2026 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required3.15 mm copper conductor (10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
CIVIL WORKS-8 Mtr Tubular Pole Mini Mast
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
13.1.1 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
ELECTRICAL WORKS-8 Mtr Tubular Pole Mini Mast
OD243552/2025-2026 Supply installation testing and commissioning of 8 Meters round pole made of galvanized iron 4 inch round in bottom with 2.5-3 inch round/combination of various size, bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for wind speed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos, luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation etc, complete Casting two layer of epoxy coating with good paint finished.
90.15.4.7 Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.14.1.2 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
OD243554/2025-2026 Supply and installation of a Digital timer, operating at 220-250 VAC, 50Hz, with a 25A/1.5HP capacity. It features 5 On/Off program settings for daily and weekly schedules, along with manual start, ON delay, and OFF delay settings. Equipped with a high-precision, industrial-grade chip and strong anti-interference capabilities, the timer can automatically turn on and off the power supply of various electrical equipment according to the time set by the user. The controlled objects can include street lights, light boxes, neon lights, and high/mini mast systems. It also includes a sufficient battery backup for time memory in case of power failure, and comes with suitable fittings for use in a distribution box or MV panel with FRLS PVC insulated 1.5 mm single core cable suitable for control wiring towards contactor
OD243558/2025-2026 Supply and installation of a double pole 25A Contactor, rated for 220-250 VAC, 50Hz operation with suitable copper socket. It can control street lights, light boxes, neon lights, high/mini mast systems, and induction loads.
OD243555/2025-2026 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 2.5 sq. mm
OD243557/2025-2026 Supply and installation of an IP20 Surge Protective Device (SPD) with suitable fittings for a distribution box or MV panel. Specifications include: Voltage Protection Level (Up), Nominal Voltage: 230V, UOC: 10kV, L-N: 7kV, L-PE: 7kV, N-PE: 7kV, Nominal Discharge Current (8/20µs): 10kA, Total Discharge Current (8/20µs): 60kA, Response Time: <35 ns, Ambient Temperature (Ta): -10 to 55°C.
OD243553/2025-2026 Supply and fixing HRC fuse base of 32 A using suitable nut and bolt, 32 A 2-way neutral links mounted on DMC/SMC base.
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.3 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.6.5.12 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD243556/2025-2026 Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor (10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
Lumsum Heading
Connection charges - KSEB
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_1391543.xls
BOQ • 0.32 MB
GCC.pdf
Tender Documents • 0.42 MB
PROFILE.pdf
Additional Documents • 0.03 MB
Download all tender documents and submit your bid