Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Accepted contract, being lowest | |
| 2 | L2₹23.3 L+₹1.1 L (4.84%)Rejected-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L2 | Rejected-AOC Rejected, being lowest | |
| 3 | L3₹25.1 L+₹2.9 L (12.9%)Rejected-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L3 | Rejected-AOC Rejected, being lowest | |
| 4 | L4₹29.4 L+₹7.1 L (32.1%)Rejected-AOC 121004 | L4 | Rejected-AOC Rejected, being lowest | |
| 5 | L5₹32.2 L+₹10.0 L (44.8%)Rejected-AOC | L5 | Rejected-AOC Rejected, being lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
12 Jul 2025, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2025_MES_714438_1
GE MAINT EZHIMALA 8759
Open Tender
Civil Works
Item Rate
330 days
Ezhimala
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹70,000
Yes
1 Aug 2025
13 Jun 2025
18 Jul 2025
13 Jun 2025
12 Jul 2025
28 Jun 2025
13 Jun 2025 - 20 Jun 2025
Amount
Notes for all items of BOQ:- 1. The contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safety measures are to be adopted by contractor on site. 3. The contractor shall provide and deploy sufficient electrician ( as approved by GE/ Engineer in charge) shall report at 9.00 hrs to JE E/M / Engineer in charge to collect the complaints job card in working days and complete the same complaint within 24 Hrs. 4. The complaints shall be rectified within 24 hrs if the complaints is/are not attended / not completed with in 24 hrs ( except repair/ replacement of major items) recovery will be done at Rs. 500 per complaint per day. 5. For major parts like replacement of MCB, DBs, MCCBs etc should be rectified within 3 working days, if the contractor not rectify within time then recovery will be done at Rs. 1000 per complaint per day. 6. After completion of Job work complaint, the contractor has to produce job card duly signed by user & JE /Engineer in charge. 7. If contractor failed to provide their electrician to attend the complaints then recovery will be done at Rs. 1000 per day.
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete including fittings such as switches ceiling roses, pendent, regulators, sockets, etc including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
Material and labour for color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC casing and capping suitable size modular metal flush box/PVC box fitted with modular cover plate with frame (inner/ outer plate) for mounting switches,sockets,regulators etc including FRLS 1.5 sqmm earth wire copper insulated connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Notes:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral and earth conductor. (iii) The wiring shall be done strictly by following proper colour coding using red , blue, yellow for phase, black for neutral and green for earth leads. (iv) Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm.
(a) One light/ fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amps on the same board with other switches
(c) 5 Amps socket point on independent board Note: Size of copper earth wire must be equal to size of current carrying conductor upto size 16 sqmm
All as per item No.03 here in above but 2.5 sqmm for 15 Amps socket on independent board complete all as specified and directed by Engr-in-charge.
Material and labour in replacement of old unserviceable sub main wiring color coded using 2 runs of 2.5 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through PVC casing capping along with 1 run of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
Material and labour in replacement of old unserviceable sub main wiring using 2 runs of 4 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing capping along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
Material and labour in replacement of old unserviceable sub main wiring using 2 runs of 6 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC casing capping along with 1 run of 6 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly complete including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge. Notes for item No. 05 to 07:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) One run of PVC conduit/casing and capping along with 3 runs of respective size of PVC insulated copper conductor cable will be measured as one unit. (iii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
Material and labour in replacement of old unserviceable sub main wiring color coded using 2 runs of 2.5sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through existing conduit along with 1 run of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly, including taking down the unserviceable wiring complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement of old unserviceable sub main wiring using 2 runs of 4 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through existing conduit along with 1 run of 4 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement of old unserviceable sub main wiring using 2 runs of 6 sq mm FRLS PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through existing conduit along with 1 run of 6 sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Notes for item No. 08 to 10:- (i) Necessary PVC rigid junction boxes for identifying junction as required on site/ directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. (ii) Three runs of respective size of PVC insulated copper conductor cable will be measured as one unit. (iii) Strictly follow the proper colour code red/yellow/blue for phase, black for neutral and green for earth.
Material and labour in replacement of old unserviceable sub main wiring using 2 runs of 1.5 sq mm FRLS , IS 694 PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through and including PVC conduit of suitable size not less than 20mm dia medium grade surface on wall along with 1 run of 1.5sq mm PVC insulated copper conductor FRLS cable as earth lead connected to common earth dolly including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
Material and labour in replacement of old unserviceable switch piano, flush mounting type, single pole, one AC 230V grade 5 Amps ISI marked including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
All as per item No.12 here in above but 15 Amp ISI marked including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable socket outlet 3 pin 5 amp multi pin type ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable socket outlet 3 pin 15 amp multi pin type ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable fan regulator electronic step up type 100/120 Watt AC 230 watts including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable ceiling rose 3 pole 240V PVC/Poly carbonate insulated body ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable modular switch one way 6 Amps 1 module ISI markedincluding taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable modular socket 6 Amps 2 module multi pin ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable modular switch one way 16 Amps 1 module ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable modular socket 16 Amps 2 module ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable modular white cover plate with frame 1 module complete all as specified and directed by Engineer-in-Charge.
All as per item No 22.00 above but 2 module all as specified and directed by the Engr-in-Charge
All as per item No 22.00 above but 3 module all as specified and directed by the Engr-in-Charge
All as per item No 22.00 above but 4 module all as specified and directed by the Engr-in-Charge
All as per item No 22.00 above but 6 module all as specified and directed by the Engr-in-Charge
All as per item No 22.00 above but 8 module all as specified and directed by the Engr-in-Charge
All as per item No 22.00 above but 12/18 module all as specified and directed by the Engr-in-Charge
Supply and fix in replacement of old unserviceable modular box suitable for fixing 1/2 module complete all as specified and directed by Engineer in charge. Note:- The rate quoted for replacing of modular box is deemed to be inclusive of necessary cement/putty work and finishing work of white wash /colour wash for matching with existing surface.
All as per item No.29 above but 3 module complete all as specified and directed by Engineer-in-Charge.
All as per item No.29 above but 4 module complete all as specified and directed by Engineer-in-Charge.
All as per item No.29 above but 6 module complete all as specified and directed by Engineer-in-Charge.
All as per item No.29 above but 8/12 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable switch socket combination 5/16 Amps 5 in one flush type ISI marked including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable MCB single pole 6 to 32 Amps capacity 230 Volts, C series 10 KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable MCB single pole and neutral 32 Amps capacity, 50 Hz ,230 Volts C series 10 KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable MCB triple pole & neutral , 40 Amps, 415 Volts AC, C-Series including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable RCBO's for earth leakage protection double pole 300 mA, 40 Amps including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable modular AC socket with MCB single pole 25/32Amps, C-Series, AC 240 Volts including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable lamp holder, PVC type suitable for pendent/batten fittings including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable fan regulator(Modular) electronic step up type 100/120 Watt AC 230 Volts including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable hylam sheet 3 mm thick suitable for switch boards etc including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of 9 W LED lamp, BEE rated white/warm white with base B22 complete all as specified and directed by Engineer-in-Charge. Make:- Havells/Philips/Crompton/Bajaj/Wipro.
Supply and fix in replacement of old unserviceable MCB DB SPN 240V double door outdoor type, 12 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable MCB DB TPN 415V double door type, 6 way with bus bar of appropriate current carrying capacity, neutral link, earth bar and din rail including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable decorative ultra slim round profile 1 feet 5Watt with extruded poly carbonate ready to use pack making connection to existing ceiling rose to fitting with 3 core, 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Havells Model No. ELITE PRIDE PLUS 5W LED 6000K or equivalent in Philips/Wipro/Havells/Bajaj.
Supply and fix in replacement of old unserviceable surface and wall mounted 10 W 2 feet LED batten,making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model TRIMLINE-LDL-10W-CDL or equivalent in Philips/ Wipro/ Havells/Bajaj.
Supply and fix in replacement of old unserviceable wall mounted 20 W 4 ft LED batten, making connection to ceiling rose to fitting with 3 core 1 sqmm including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton TRIM LINE. LDL-20-CDL or equivalent in Philips/Wipro/ Havells/ Bajaj.
Supply and fix in replacement of old unserviceable LED down light fitting 12W white/ warm white with round shaped making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model PEARL NIOS-R-LCDSPLN-R-12-CDL / Philips/Wipro/ Havells/Bajaj.
Supply and fix in replacement of old unserviceable LED down light fitting 18W white/ warm white with round shaped making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model PEARL NIOS-R-LCDSPLN-R-18-CDL/ Philips/Wipro/ Havells/Bajaj.
Supply and fix in replacement of old unserviceable LED white/ warm white bulk head fitting 10W making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including taking down the unserviceable items complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model STUD- LBHP-10-CDL / Philips/Wipro/ Havells/Bajaj.
Supply and fix in replacement of old unserviceable surface mounted 18W luminaire 1x1 tile, making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:-Crompton Model PEARL NIOIII- S-LCTLSNE-18-FO-CDL/ Philips/Wipro/ Havells/Bajaj.
Supply and fix in replacement of old unserviceable recess mounted 36W luminaire 2x2 making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton. Model PolarisNIO I LCTLRNE-36-FO-CDL / Philips/Wipro/ Havells/Bajaj.
Supply and fix in replacement of old unserviceable surface mounted 36W luminaire 2x2 tile, making connection to ceiling rose to fitting with 3 core 1 sqmm copper conductor including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engineer-in-Charge. Make:- Crompton Model Polaris NIO III I LCTSNE-36-FO-CDL / Philips/Wipro/ Havells/Bajaj.
Material and labour for checking / replacing the worn out parts such as rubber pulley, locking pin, nuts and washer of ceiling fan any size complete with one coat of synthetic enamel white paint by spraying after cleaning all dust etc complete all as specified and directed by Engr-in-Charge.
Material and labour for painting exhaust fan of any sweep complete with one coat of synthetic enamel suitable paint by spraying after cleaning all dust etc complete all as specified an directed by Engr-in-Charge.
Material and labour for painting wall mounting fan / air circulator of any sweep complete with one coat of synthetic enamel suitable paint by spraying after cleaning all dust etc complete all as specified an directed by Engr-in-Charge. Note:- Repair works for item No. 55 to 57 shall be measured and paid seperately.
Material and labour for dismantling / opening the ceiling fan of 1200/1400 mm sweep of any make, removing the old defective winding carefully, cleaning the inner parts and re-winding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specifed and directed by Engineer-in-Charge.
Material and labour for dismantling/opening the exhaust fan of 300 mm sweep of metal body of any make, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and directed by Engineer-in-Charge.
All as per item No.59 above but for 450 mm sweep exhaust fan metal body complete all as specified and directed by Engineer-in-Charge.
All as per item No.59 above but for plastic body 250 mm sweep exhaust fan complete all as specified and directed by Engineer-in-Charge.
Material and labour for dismantling/opening the wall mounted fan 400mm sweep of metal body, any make, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and directed by Engineer-in-Charge.
Material and labour for dismantling/opening the air circulator fan 630 mm sweep of metal body, any make, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and directed by Engineer-in-Charge.
Material and labour for dismantling ceiling fan of any size and sweep, removing old bearing and buses of any size, supply and fixing new bearing of suitable size and of make SKF /TATA /NBC/Lucas and buses including greasing, reassembling and testing complete all as specified and directed by Engineer-in-Charge.
Material and labour for dismantling wall mounting fan of any size and sweep, removing old bearing and buses of any size, supply and fixing new bearing of suitable size and of make SKF/TATA/NBC/Lucas and buses including greasing, reassembling and testing complete all as specified and directed by Engineer-in-Charge.
Material and labour for dismantling exhaust fan of any size and sweep, removing old bearing and buses of any size, supply and fix with new bearing of suitable size and of make TATA/NBC/SKF/Lucas and buses including greasing, reassembling and testing complete all as specified and directed by Engineer-in-Charge.
Material and labour for removing old unserviceable fan capacitor, supply and fixing new capacitor 2.5mfd 440Volts of suitable make and size including testing the fan complete all as specified and directed by Engineer-in-Charge.
Material and labour for removing defective old capacitor, supply and fixing new capacitor of 4 mfd suitable for exhaust fan/air circulator of any size, make, model and testing complete all as specified and directed by Engineer-in-Charge.
Material and labour for removing defective old capacitor, supply and fixing new capacitor of 6 mfd suitable for exhaust fan/air ciculator of any size, make, model and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable exhaust fan louver up to 300 mm dia including taking down of old louver and matching disturbed surface by proper painting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable exhaust fan louver 450 mm dia including taking down of old louver and matching disturbed surface by proper painting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable ceiling fan blade 1200/ 1400mm sweep as per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable exhaust fan blade 300/ 450 sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable exhaust fan blade 250 mm sweep (plastic) complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable air circulator blade 400/ 630mm sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable air circulator blade 450/ 630mm sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable base asssembly of air circulator including painting of matching colour for any sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable rear dom of air circulator including painting of matching colour as per front side for any sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable wall mounted fan grill set complete including taking down of old one for any sweep as per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable air circulator grill set complete including taking down of old one for any sweep as per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable ceiling fan down rod as approved of any sweep and 2.1 mtr long complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of old unserviceable ceiling fan down rod as approved of any sweep and 1.5 mtr long complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of old unserviceable ceiling fan down rod as approved of any sweep and 0.9 mtr long complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of old unserviceable canopy of matching colour as existing suitable for ceiling fan of any sweep complete all as specified and directed by Engineer-in-Charge.
Material and labour for dismantling the existing geyser 25/50 ltrs capacity and transporting to work shop for repair, opening the body carefully and taken out the container and arrest the water leakage by bracing/soldering the copper/brass rods and refixing and return back to site and refixing at the existing location complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable thermostat 0° C to 80° C for geyser complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable geyser element 1500W, cup type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable geyser element 1500 W, triangular type complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable PVC hot water connection pipe 45 cm long complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of old unserviceable indication lamp square/ round in red and green colour, 230 Volts AC complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair rigid non-metallic 25mm PVC casing capping exclusive of wall rawl plugs/gitti and screw, including making good the existing disturbed surface using wall putty and matching colour emulsion paint complete all as specified and directed by Engr-in-charge.
JEETH CONSTRUCTION (BID ID -3347390)
SREEKRUPA ENTERPRISES (BID ID -3348044)
Neptune Engineers and Builders (BID ID -3356739)
TAMS ASSOCIATES (BID ID -3345733)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .