| 1 | 1₹2.2 CrAccepted-AOC | ₹2.2 Cr | 1 | Accepted-AOC Lowest bidder |
| 2 | 2₹2.5 Cr+₹33.9 L (15.6%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹2.5 Cr+₹33.9 L (15.6%) | 2 | Rejected-Finance 2nd lowest bidder |
| 3 | 3₹2.6 Cr+₹44.2 L (20.3%)Rejected-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹2.6 Cr+₹44.2 L (20.3%) | 3 | Rejected-Finance Highest bidder |
| 4 | Rejected-Technical ASHOK MARG LUCKNOW UTTAR PRDESH 226001 | LUCKNOW | UTTAR PRADESH | 226001 | - | - | Rejected-Technical Tender fee and EMD not received in the office on due date and time |
| 5 | Rejected-Technical | - | - | Rejected-Technical Tender fee and EMD not received in the office on due date and time |
Tender Value
₹2.3 Cr
EMD Value
₹4.7 L
Closing Date
2 Jun 2020, 6:00 pmClosed
Asst.GM(E--E)-II
O/o Airport Director, AAI, Calicut International Airport, Malappuram - 673 647
Operation and Maintenance of Electrical and Mechanical Installations of Terminal Buildings, Technical Block, Residential Colony, Car Park, Street Lights Water Supply, Fire Fighting etc. of Calicut International Airport during 2020-22
2020_AAI_47284_1
AAI/CL/ENGG(E)/NIT-01/2020-21
Open Tender
Electrical Works
Works
730 days
AAI, Calicut International Airport
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,130
AAI, Calicut
₹4.7 L
24 Jul 2020
21 May 2020
10 Jun 2020
22 May 2020
2 Jun 2020
22 May 2020
22 May 2020 - 2 Jun 2020
Amount
Operation and periodic maintenance of all Electrical and Mechanical installations at different buildings/installations of airport such as Terminal building, Residential Colony, Pump Houses including but not limited to: operation of pumps for water supply and firefighting, lift, escalator, different switchgears, Carpark/street lighting including rectifying defects/faults/breakdowns in round the clock shifts, on all days including Sundays, all Holidays including preparation & maintenance of associated log books and records etc, complete as required.
Engaging of unskilled labour for carrying out casual/unspecified works like clearing of site, shifting of inventory, and other miscellaneous Electrical works as per instructions from Engineering in charge ( 1 man day = 8 hours of work).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 6 sq. mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 20 mm
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 25 mm
Supply and fixing PVC casing capping of following sizes on surface as reqd. 20 mm x 12 mm
Supply and fixing PVC casing capping of following sizes on surface as reqd. 25 mm x16 mm
Supply and fixing PVC casing capping of following sizes on surface as reqd. 38 mm x16 mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 4 Module (100mmX75mm`)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required 6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in surface/recess etc as required. 1 or 2 Module
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc as required. 4 Module
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. ( GROUP B)
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 75 mm X 60 mm deep
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc .with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Repairing of earth pit by demolishing the existing damaged brick work, making fresh brick work, plastering the same, providing and fixing MS hinged cover, numbering the earth pit with suitable paint etc as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc.as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq.mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width,m and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) including form work etc as required.
Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 20 mm nominal size) including form work etc as required.
Spray painting with two or more coat of synthetic enamel paint of approved brand, manufacturer and colour to give an even shade for distribution boards,Fire hydrant Pipes, Internal & External Electrical panels/ Junction boxes/feeder pillars, etc. provided in the Terminal Buildings, Technical Block and other Ancillary Buildings including cleaning the surface, applying two or more coats of primer wherever necessary,removing, shifting of installations from existing site to a suitable site for painting where ever required.Scope also includes re-lettering / new lettering of various distribution boards/ panels wherever required.
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m. (a) All kinds of soil Pipes, cables etc, not exceeding 80 mm dia.
Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. bituminous portion
Replacing the damaged bearing of 25 HP jockey pump motor coupling including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required
Replacing the damaged bearing of 120 HP main fire pump motor coupling including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required
Replacing the damaged rubber bush of 120 HP main fire pump motor coupling including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required
Replacing the damaged rubber bush of 25 HP jockey pump motor coupling including labour charges for dismantling the coupling, refixing the coupling , ensuring proper shaft alignment etc. as required
Lifting and lowering of submersible pump along with the installed pipe from bore well ( up to 400 feet max) including dismantling the defective submersible motor, pump set and installing the serviceable motor pump set with the existing pipe, arranging T&P and necessary consumables etc complete as required Submersible pumps installed with HDPE/PVC Pipe
Lifting and lowering of submersible pump along with the installed pipe from bore well ( up to 400 feet max) including dismantling the defective submersible motor, pump set and installing the serviceable motor pump set with the existing pipe, arranging T&P and necessary consumables etc complete as required Submersible pumps installed with GI pipe with Sockets/ Flanges
Lifting of defective submersible/ monoblock motor pump set from openwell/sump and dismantling the same and installing the serviceable motor pump set arranging T&P and necessary consumables including lifting and lowering into sump/openwell etc complete as required (Serviceable Motor will be provided by AAI).
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Borewell) Above 2 HP and up to 5 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Borewell) Above 5 HP and up to 10 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Borewell) Above 10 HP and upto 15 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Borewell) Above 15 HP and upto 17.5 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Openwell/sump) Above 2 HP and up to 5 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Openwell/sump) Above 5 HP and up to 10 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Submersible Motor (Openwell/sump) Above 10 HP and upto 15 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Monoblock Pump Motor Above 2 HP and up to 5 HP
Rewinding of following type of motors with enameled/Teflon coated copper wire varnishing & baking along with gunmetal bushes, thrust bearing etc and including to&fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) Monoblock Pump Motor Above 5 HP and up to 10 HP
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 2 HP and up to 5 HP Thrust bearing
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 2 HP and up to 5 HP Bushes
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 2 HP and up to 5 HP Shaft sleeve
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 2 HP and up to 5 HP Thrust plate
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 5 HP and up to 10 HP Thrust bearing
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation . Submersible Motor (Openwell/Borewell/sump) Above 5 HP and up to 10 HP Bushes
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 5 HP and up to 10 HP Shaft sleeve
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 5 HP and up to 10 HP Thrust plate
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 10 HP and upto 15 HP Thrust bearing
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 10 HP and upto 15 HP Bushes
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 10 HP and upto 15 HP Shaft sleeve
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Submersible Motor (Openwell/Borewell/sump) Above 10 HP and upto 15 HP Thrust plate
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Monoblock Pump Motor Above 2 HP and up to 5 HP Bearing
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Monoblock Pump Motor Above 2 HP and up to 5 HP Bushes
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Monoblock Pump Motor Above 2 HP and up to 5 HP Shaft sleeve
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Monoblock Pump Motor Above 5 HP and up to 10 HP Bearing
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Monoblock Pump Motor Above 5 HP and up to 10 HP Bushes
Servicing of the following capacity submersible/mono block pumps including replacing the following components and refixing back complete as required and making the pump suitable for satisfactory operation. Monoblock Pump Motor Above 5 HP and up to 10 HP Shaft sleeve
Repairing of Soft starter (Make: L&T, Model : EMX3-0145B-V4-C1-H) used for fire fighting main electric pump, includingrepair/ replacement of any components like SCR, control card, display etc. including testing and commissioning of the same. The cost shall include to and fro transport of the soft starter to the service location of the specialized agency/L&T authorized centre as the case may be.
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 600mm. Sweep aircirculators
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 450mm. Sweep aircirculators
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 300/380mm. Sweep Exhaust fan 900rpm heavy duty
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 300mm. Sweep Exhaust fan 1400 rpm light duty
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 1200mm. Sweep ceiling fan
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 400 mm. sweep wall mounting fan
Rewinding of following type of Air Circulators/ceiling fans/exhaust fans with enamelled copper wire, baking, varnishing, overhauling, greasing, refitting of motor etc and including to & fro transportation etc. complete as required (Burnt copper need not be returned to AAI. Rate shall be quoted accordingly) 400 mm. sweep pedestal fan
Maintenance of Addressable Fire Alarm System consisting of Fire Loop, Addressable Panel, Fire Alarm Repeater Panel, Photo Electric Smoke Detectors, Multi detectors, Heat detectors, Beam Detector, Manual Call Point, Response Indicator, Fault Isolator, Hooter / Sounder, Control Relay Module, Monitor Module etc. as complete installed at various locations as detailed in the inventory list, by monthly servicing and attending breakdown repairs including replacement of defective component/devices, Corrections, re-installation, repair, replacement, modification, programming of PC, device configuration and ID assigning, firmware configuration etc. complete as and when required, through specialist agency/ OEM/ manufacturer whenever required. The scope shall also include Comprehensive all inclusive (Hardware and OS) maintenance of computer system , installed with fire alarm detection and warning system including all connected devices such as CPU, keyboard, mouse, monitor, printer, UPS etc. ( Service for one month = 1 JOB)
Providing services for obtaining certificate of approval/ license for firefighting and alarm system at Calicut International airport, including liaisoning with the concerned state/central govt.department, preparation of all documents and drawings required, providing any expert support for preparation of the application form, follow up with the departments etc. as required till the issuance of the license/certificate by the concerned authority to AAI.
Rectification of fire alarm system by checking all individual smoke/heat detectors/MCP/Beam detectors replacing the faulty ones, including making interconnections of the cable to the detectors, making all field devices of the fire alarm system serviceable in all respect, programming the fire alarm panel by including all devices which are not reflected in the panel, configuring the management software to show all new devices programmed, etc. to make the fire alarm system 100% serviceable and intact in all respect, complete to the satisfaction of the Engineer In Charge. The detectors/MCP/beam detectors/ cable for interconnection of detectors will be provided by AAI.
Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors). The item shall be suitable for integration to Edwards EST fire alarm control panel.
Supplying, Installing, Testing and Commissioning of UL / EN listed (Latest Version) Addressable motorized auto align Beam detector with transmitter, receiver & control panel as per specification, complete as required. The item shall be suitable for integration to Edwards EST fire alarm control panel.
Supply, installation, testing and commissioning of UL / EN listed (latest version) loop powered addressable Hooter-cum- strobe with inbuilt fault isolator / isolator module with adjustable sound level in the range of min. 90 dB to Max. 120 dB at 1M distance complete with termination etc. as required and as per enclosed specification. The item shall be suitable for integration to Edwards EST fire alarm control panel.
Supply and laying of 2 x 1.5 sq.mm. FRLS armoured cable, 600 / 1000V rated with annealed copper conductor, as per applicable IS standards, on surface / recess/ on channel/ cable tray/above false ceiling.
Blue Star Limited
Voltas Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .