| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹48.7 L+₹1.1 L (2.25%)Rejected-Finance 37 A MURGI MAHAL SADAR BAZAR PO BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹48.9 L+₹1.3 L (2.69%)Rejected-Finance NEAR MOHANPURA BALAJI ROAD TEH KISHANGARH RENWAL DIST JAIPUR 303603 | JAIPUR | RAJASTHAN | 303603 | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹49.0 L+₹1.4 L (2.89%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹49.2 L+₹1.6 L (3.28%)Rejected-Finance MISTRY GHAT MONIRAMPORE PO BARRACKPORE DIST 24 PARGANAS NORTH WEST BENGAL PIN 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
30 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
PROVN OF ONE SEPTIC TANK OF OFFICERS MESS, PROVN OF COVERED SHED WITH HARD STANDING INFRONT OF BLDG NO. 36 AT BSO YARD, PROVN OF STANDBY SEWAGE SUBMERSIBLE PUMP AND OTHER CONNECTED WORKS FOR RCTC AREA, PROVN OF EXTENSION OF EXISTING
2023_MES_611853_1
8805/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹92,000
Yes
19 Sept 2023
2 Aug 2023
1 Sept 2023
2 Aug 2023
30 Aug 2023
16 Aug 2023
Amount
PART-I Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Surface excavtion not exceeding 30cm in deep and averageing 15cm deep and geting out in soft/loose soil.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Bringing approved earth filling, earth obtained from out side of Defence land to a distance exceeding 5.00 Km but not exceeding distance 15 Km and depositing where directed and spreading and levelling in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for broken bricks hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole, landings cover slab for manhole, chullah hoods, chajjas, water through, managers, shelves and similar articles set in cement mortar (1:4) complete all as specified and directed. (NOTE: Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor and reinforcement shall be measured and paid Separately.)
M&L for cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in benching inside of manhole, coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in benching inside of manhole, coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
Cutting upto a depth of 12.5cm into concrete walls and trimming surface as required, girth exc. 30cm complete all as specified and directed.
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:4) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for 25 mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in damp proof course to horizontal surface including necessary form work complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of rolled mild steel angle iron roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F of framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F of 1mm thick lath steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple including one shop coat of primer; erected in position as indicated, complete: push pull or manual type including taking down old unserviceable rolling shutter complete all as specified and directed.
S&F of 1mm thick lath steel rolling shutters, gear operated type with beval gear box and crank handle with out ball bearing, as specified including top cover, anchoring rod, hasp and staple including one shop coat of primer; erected in position as indicated, complete: push pull or manual type including taking down old unserviceable rolling shutter complete all as specified and directed.
Taking down steel rolling shutters any type and refixing in same opening after easing and adjusting and minor repair completed all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base of foot path/ paving complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base of foot path/ paving complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection & floor including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 40 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor etc finished even and smooth with using extra cement complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) laying over and including 50mm thick sand filling complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles (vertical) 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thick or equivalent set and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 10 mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
M&L for 20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) as screed bed complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for applying one coat of synthetic enamel paint (1st grade quality) after preparation of old steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick putty on wall surfaces after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on newly plastered surface of walls including preparation of surface after complete removal of existing treatment complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 15 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 20 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F of 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F of 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F of 15mm dia bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 20mm dia ball valve high pressure of PTMT (minimum weight 210 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor after complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F of LLDPE Sepctic Tanks, on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, vent shaft, connection etc complete for fixing in any type of including connection etc vent shaft complete upflow filter including media etc complete for 50 users all as specified and directed.
M&L for soak wells of size 1.20m dia X 3.00m effective depth (internal), excavation in any type of soil, foundation in PCC (1:3:6) , walls of honey combed masonry with top ring of M-25 (nominal mix) concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/CWC complete with brick bats complete all as specified and directed.
PART-II (ELECTRICAL WORK) Supply, installation, commissioning and testing of automatic sewage submersible pump set of capacity 7.5HP, 3 phase, 415 volts, 50 Hz suitable for min 12m head and min 50000 LPH discharge including connection to existiing DOL starter for making pump automatic including necessary items required for automation, pump should be capable of dischargeing sludge and solid upto 35mm size pump complete all as specified and as directed.
M&L for desludging of sewage collection sump by taking out sewer slurry using buckets and pullys of total depth 7.50m including depositing at a distance not exceeding 500m from starting point and taking out serviceable/ unserviceable non clog sewage submersible pump motor carefully and re-install the same after thorough cleaning, overhauling and servicing with removing of all sewage sludge complete testing and commissioning all as specified and as directed. (Note:- Maximum storage capacity of sewage sump will be 10000gallon.)
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of pain complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
S& F of 40mm to 80mm dia PVC heavy duty suction hose pipe including clamp and other fixing arrangements for connection outlet of submersible pump to required location complete all as specified and as directed.
S& F of roller stainless steel chain having roller dia min 12mm and pitch min 8mm along with hooks for holding pump under sewage water complete all as specified and as directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One ceiling fan/exhaust fan point controlled by one switch and one regulator.
S&F of ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of integrated LED bulk head luminaires of 10 watts pressure die cast housing acrylic diffuser ans frame with IP 65 protection complete all as specified and directed.
S&F of 3mm thick PVC rectangular block sheet cover for mounting switch of size 350mm x 300mm complete all as specified and directed.
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / L&T Cat No.DBSPN008GD or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F of MCB, SPN, 32 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work after and including taking down old unserviceable sub main wiring complete all as specified and directed. {Note : (i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate}.
S&F of heavy duty type exhaust fans AC single phase 230/240 V of size 225 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 225mm-900RPM or equivalent model of Crompton Greaves as approved).
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
SWAPAN CONSTRUCTION
SHANKAR CONSTRUCTION CO
FALCONS INDIA
SWWAPAN BUILDERS
ABHISHEK CONSTRUCTION CO
PUNAM ENTERPRISE
N. MUKHERJEE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .