Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC H NO 54 8 DARMYANA MUHALLA DISTT MANDI 1750051 | MANDI | MANDI | HIMACHAL PRADESH | 175005 | L1 | Accepted-AOC Bidder is L1 | |
| 2 | L2₹36.5 L+₹13,178.25 (0.36%)Rejected-Finance | L2 | Rejected-Finance Quoted rate is highest |
Tender Value
₹37.4 L
EMD Value
₹74,715
Closing Date
14 Jun 2021, 3:00 pmClosed
Superintending Engineer IIT Mandi
O/o Superintending Engineer IIT Mandi Kamand Distt. Mandi H.P.
Re-Tender for Channelization of roof water of various blocks (C29,30,31,32,34, 36, 37, 10, 13, 14, 15, 16, 24, 23 and C-22, B-13, 14, 23, 21, 20, 16, 09, 17, 24, 26, 25, 10, 12, 18, 15, 19, A10 and A12) at North Campus of IIT Mandi.
2021_IITMD_626597_2
IITMandi (CW)/SE-1118/2021-22/306-08 dt 13/04/2021
Open Tender
Civil Works
Item Rate
120 days
North Campus of IIT Mandi
Please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹74,715
1 Jul 2021
21 May 2021
15 Jun 2021
21 May 2021
14 Jun 2021
21 May 2021
21 May 2021 - 11 Jun 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, in all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within all lead for all kinds of soil, as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within all lead for all kinds of soil, Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia, as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 160 mm diameter as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Coupler 160 mm as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Coupler 110 mm as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 160 mm bend as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Bend 87.5° 110 mm bend as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Demolishing cement concrete manually/ by mechanical means including disposal of material within all lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) as per the entire satisfaction and direction of engineer-in-charge including carriage of material in all lead and lift.
Providing and fixing brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 as per entire satisfaction and direction of Engineer -in- Charge including carriage of material in all lead and lift.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick as per entire satisfaction and direction of Engineer -in- Charge including carriage of material in all lead and lift.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W./PVC pipes including bed concrete as per standard design : 100 mm diameter PVC pipe as per entire satisfaction and direction of Engineer -in- Charge including carriage of material in all lead and lift.
"Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W./PVC pipes including bed concrete as per standard design : 160 mm diameter PVC pipe as per entire satisfaction and direction of Engineer -in- Charge including carriage of material in all lead and lift"
"Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 as per entire satisfaction and direction of Engineer -in- Charge including carriage of material in all lead and lift"
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single tee 160X160X160 mm as per entire satisfaction and direction of Engineer -in- Charge including carriage of material in all lead and lift
deepanshu gautam govt cont
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .