Supply and fixing Distribution Boards DBs at HAL Korwa
8029
HAL/KWD/PM/23/SPR/217
Works
Accessories Complex - Avionics Divn - Korwa
₹0
₹42,710
22 Jul 2024
22 Jun 2024
22 Jun 2024
22 Jul 2024
Hindustan Aeronautics Limited Avionics Division, Korwa Post Office : HAL The : Amethi Dist : Amethi (UP) - 227412
Name of work: "Supply and fixing Disritbution Boards (DBs) at HAL Korwa."
Name of The Contractor :
BILL OF QUANTITIES WITH SPECIFICATIONS
The tenderers are requested to read the following before quoting:
1 The payment terms shall be governed as per the terms indicated in General conditions of contract.
2 Basic Rate to be quoted for each item.Subject work is called on works contract basis and prevailing GST of 18% has been added in the BOQ on overall total. Any revision on this GST rate is to HAL account.
3 Sucessful offer that is L-1 (Lowest offer) will be determined including GST.
4 Amount towards GST will be paid along with RAR payment against invoice.
5 The tenderers are requested to abide by the rules of prevailing GST act.
6 This BOQ specification has to be read in conjunction with technical specifications and tender drawings. Any ambiguty in these have to be brought to the knowledge of contract section before submission of tender to avoid future claims/dispute.
Sl. No Specification of item Quantity Unit Rate in Figs excluding GST Rate excluding GST in words Amount Excluding GST in Figs (E=C*A)
1 Supply, Fixing and Testing of 12-Way Vertical TPN double door DB of suitable for FP Isolator 100A as incomer and TP/SP Lexic C type MCBs as outgoing by dismantelling the existing old 12 way MDS/Loadster-make concealed DBs, MCBsetc. complete in all respect as per direction of EIC as following:- i) DB construction: CRCA sheet steel with powder coated, IP 43-IK-09 protection, Duly fitted DIN channel, Insulated Neutral link, Insulated Earth bar, Insulated Bus bar, Detachable gland plate, metal door, Blanking Plate etc. ii). New DB will be concealed in wall by cutting the wall of appropriate size and making good surrface by plastering cement of 1:3 ratio. iii). Proper connection the existing incomming and outgoing points. iv). Supply and fixing of suitable size of lugs in incommer cable and gland (if required) as per site requirement. v). Supply and connecting the suitable size wire such as 1.5/2.5/4 sqmm FRLS PVC insulated single core copper cable for extending the outgoing points (if required) as per site requirement. vi). Supply and fixing of Electrical Danger sticker (440 Volt). vii). Shifting of old loadster DBs, MCBs etc. to store. viii). Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider Note: All civil work for dismanteling of old DB and fixing of new DB will be in vendor scope. 20 Nos. 0.00
2 Supply, Fixing and Testing of 8-Way Vertical TPN double door DB of suitable for FP Isolator 100A as incomer and TP/SP Lexic C type MCBs as outgoing by dismantelling the existing old 8-way MDS/Loadster-make concealed DBs, MCBsetc. complete in all respect as per direction of EIC as following:- i) DB construction: CRCA sheet steel with powder coated, IP 43-IK-09 protection, Duly fitted DIN channel, Insulated Neutral link, Insulated Earth bar, Insulated Bus bar, Detachable gland plate, metal door, Blanking Plate etc. ii). New DB will be concealed in wall by cutting the wall of appropriate size and making good surrface by plastering cement of 1:3 ratio. iii). Proper connection the existing incomming and outgoing points. iv). Supply and fixing of suitable size of lugs in incommer cable and gland (if required) as per site requirement. v). Supply and connecting the suitable size such as 1.5/2.5/4 sqmm FRLS PVC insulated single core copper cable for extending the outgoing points (if required) as per site requirement. vi). Supply and fixing of electrical danger sticker (440 Volt). vii). Shifting of old loadster DBs, MCBs etc. to store. viii). Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider Note: All civil work for dismanteling of old DB and fixing of new DB will be in vendor scope. 50 Nos. 0.00
3 Supply, Fixing and Testing of 4-Way Vertical TPN double door DB of suitable for FP Isolator 63 A as incomer and TP/SP Lexic C type MCBs as outgoing by dismantelling the existing old 8-way MDS/Loadster-make concealed DBs, MCBsetc. complete in all respect as per direction of EIC as following:- i) DB construction: CRCA sheet steel with powder coated, IP 43-IK-09 protection, Duly fitted DIN channel, Insulated Neutral link, Insulated Earth bar, Insulated Bus bar, Detachable gland plate, metal door, Blanking Plate etc. ii). New DB will be concealed in wall by cutting the wall of appropriate size and making good surrface by plastering cement of 1:3 ratio. iii). Proper connection the existing incomming and outgoing points. iv). Supply and fixing of suitable size of lugs in incommer cable and gland (if required) as per site requirement. v). Supply and connecting the suitable size such as 1.5/2.5/4 sqmm FRLS PVC insulated single core copper cable for extending the outgoing points (if required) as per site requirement. vi). Supply and fixing of electrical danger sticker (440 Volt). vii). Shifting of old loadster DBs, MCBs etc. to store. viii). Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider Note: All civil work for dismanteling of old DB and fixing of new DB will be in vendor scope. 12 Nos. 0.00
4 Supply, Fixing and Testing of 8-Way SPN double door DB of suitable for DP Isolator 63A as incomer and SP Lexic C type MCBs as outgoing by dismantelling the existing old 8 way MDS/Loadster-make concealed DBs, MCBs etc. complete in all respect as per direction of EIC as following:- i) DB construction: CRCA sheet steel with powder coated, IP 43-IK-09 protection, Duly fitted DIN channel, Insulated Neutral link, Insulated Earth bar, Insulated Bus bar, Detachable gland plate, metal door, Blanking Plate etc. ii). New DB will be concealed in wall by cutting the wall of appropriate size and making good surrface by plastering cement of 1:3 ratio. iii). Proper connection the existing incomming and outgoing points. iv). Supply and fixing of suitable size of lugs in incommer cable and gland (if required) as per site requirement. v). Supply and connecting the suitable size such as 1.5/2.5/4 sqmm FRLS PVC insulated single core copper cable for extending the outgoing points (if required) as per site requirement. vi). Supply and fixing of Electrical Danger sticker (440 Volt). vii). Shifting of old loadster DBs, MCBs etc. to store. viii). Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider Note: All civil work for dismanteling of old DB and fixing of new DB will be in vendor scope. 30 Nos. 0.00
5 Supplying and fixing of 100 A, FP, 415V, Isolator suitable as incommer for above 12 way, 8-way, TPN DB making connection and testing as per direction of EIC. Make :Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider 70 Nos. 0.00
6 Supplying and fixing of 63 A, FP, 415V, Isolator suitable as incommer for above 4-way TPN DB making connection and testing as per direction of EIC. Make :Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider 12 Nos. 0.00
7 Supplying and fixing of 63A, Double poles (DP), 240V, Isolator suitable as incommer for above 8 way SPN DB making connection and testing as per direction of EIC. Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider 30 Nos. 0.00
8 Supplying and fixing of 32A, 415V,10KA, 'C' curve miniature circuit breaker (MCB) of Triple poles (TP) suitable as outgoing for above 12 way, 8 way, 4 way TPN DBs making connection and testing as per direction of EIC. Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider 200 Nos. 0.00
9 Supply and fixing 05 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single poles (SP) suitable as outgoing for above DBs complete with connection and testing as per direction of EIC. Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider 1500 Nos. 0.00
10 Supply and fixing 63 amp, DP, rating 240V, RCCB , having a sensitivity current 30mA in the existing MCB DB complete with connection, testing and commissioning as per direction of EIC. Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider 30 Nos. 0.00
11 Supply and fixing 63 amp, FP, rating 415V, RCCB , having a sensitivity current 30mA in the existing MCB DB complete with connection, testing and commissioning as per direction of EIC. Make: Legrand /Havells /L&T /C&S Electric/ Hager/Schneider 12 Nos. 0.00
12 Supply, making & testing of earth pit for earthing as per IS standard (IS 3043 : 1987 or latest), the job involves digging of pit, supply & fixing of GI earth pipe 4.5 mtrs long, 40mm dia, class B, make Jindal/TATA, including accessories and providing masonry encloser with cover plate having locking arrangment and watering pipe with Charcoal & salt (40 Kg each approx) suitable GI reducer CI funnel CI hinged Chamber cover, GI nipple etc as per direction of EIC. 25 Nos. 0.00
13 Supply and laying of 25mm X 5 mm GI strip at surface/ 0.50 meter below ground as strip earth electrode, including connection/ terminating with G. I. nut, bolt, spring, washer etc. as per direction of EIC. 800 Meter 0.00
Total (Rs.) 0.00
Add GST @18% 0.00
Grand Total amount including GST (Rs.) 0.00
Total Amount in words
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
NIT.pdf
TENDER_DOCUMENT • 0.29 MB
TechnicalBid.pdf
TENDER_DOCUMENT • 4.52 MB
PriceBid.xlsm
TENDER_DOCUMENT • 0.08 MB
PQFreeView.pdf
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .