Supply of various laboratory Item in Agricultural Research Station Mandor at Agriculture University Jodhpur.
2020_AGUJD_178291_1
122 DATED 17.02.2020
Open Tender
Laboratory and scientific equipment
Item Rate
25 days
Jodhpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
1000 Zonal Director Research, ARS, Mandor, Jodhpur
₹38,000
Yes
29 Feb 2020
19 Feb 2020
29 Feb 2020
19 Feb 2020
29 Feb 2020
19 Feb 2020
Amount
Lab Items (including FOR at ARS, Mandor)
Double Stage Distillation Unit It should be complete with glass flask with heating elements, glass coil internally at bottom, metallic stand, rings clamps & electrical fitting complete with glass fitting. Flask capacity should be at least 5 liters. Double Stage Distillation Unit It should be complete with glass flask with heating elements, glass coil internally at bottom, metallic stand, rings clamps & electrical fitting complete with glass fitting. Flask capacity should be at least 5 liters.
Digital Weighing Balance LED Display Pan size should be 90mm, accuracy 1 mg (0.001gm) with maximum weight capacity of 120 g
Electronic Weighing Balance LED Display Pan size should be 320mm x 360 mm, accuracy 1 g with maximum weight capacity of 60 kg. It should be battery operated for field use with good battery backup.
Ordinary Rain Gauge (Non Recording) Non recoding Rain Gauge should be manufactured as per IS: 5225 : 1969. It should be manufactured from non corrosive fiber glass reinforced plastic container. It should be consist of collector assembled with brass ring, funnel, locking rings and base. The Rain Gauge should be supplied with 2 liter bottle and two measuring cylinders for measuring rainfall in millimeter. Collection area should be 200 sq. cms.
Maximum & Minimum Thermometer It should measure Maximum (hi) and Minimum (low) temperatures in Celsius (°C) and Fahrenheit (°F), ranging 0 to 50. It should have provision for wall mounting.
Thermo-hygrometer - Digital It should be consists of hygrometer with alarm sensor LID displaying temperature, relative humidity, date and time.
Sunshine Recorder It should be made as per IMD & IS : 7243 – 1970, fitted complete in all parts such as described for Campbell Stokes, glass spheres, sphere supports, sphere clamps, card supports, support screws, leveling screws, lock nuts, check nuts, base plates. It should be supplied with all types of sunshine cards.
Digital Soil Moisture Meter It should have 4 digits, 10mm LCD, with operating temperature & humidity range from 0 deg C to 50 deg C (32 deg F to 122 deg F) & <= 85%, accuracy in moisture : +/-(0.5%n+0.1), Temp : +/-0.8 deg C, Resolution of 0.1, measuring range of moisture up to 70 percent and temperature -10 deg C to 65 deg C, size approx: 178 x 68 x 39 mm, power supply by batteries 4×1.5V AA, with warranty of at least one year.
Digital Colony Counter It should have 4 digit LED display, counting plate with illuminated standard, digital increments of count by 1, maxi. colony count 9999, with 100 mm dia lens
Soxhlet Extraction Unit It should be 6 Test Mantle type with flask capacity 50-500 ml, 2 vertical 2 horizontal rod with adaptors and screw to hold the flasks with glass parts. Outer MS duly Powder Coated.
Tarpaulin It should be high tensile strength and puncture resistance, light weight, flexible, tough and durable heat sealed hemming strong joints; no stitches, protective UV stabilized on both sides, long lasting even in sunny outdoors, made of at least 125 GSM Sheets (at least 12 ft X 12 ft size, preferably blue in colour)
Knapsack Sprayer It should be agricultural sprayer of capacity 16 litres, which can be suitably customized for both right or left hand operation for spraying on field crops. It should be sturdy 6 mm thickness anti-corrosive high density polymer tank and stainless steel lance, total weight of the sprayer should be less than 4 kg. It should be supplied with 3 types of nozzle including single, double and flat fan and spare parts washers, nozzles, chemical filter basket
Sickle It should be 8 inch sickle with single or double edge with handle for harvesting field crops.
Soil Thermometer It should be 100 mm long brass cone at bottom, measuring range of temperature 100°C or 180°F
Infra Red Thermometer It should have LCD with back light, laser targeting, one hand operation, temperature range -50 to 550°C
Autoclave Vertical Inner Chamber 304 Grade S.S. & Outer M.S. Should be with wing nut type locking arrangement, Spring Loaded SafetyValve, Steam pressure 5 to 20 psi, Pressure Gauge, Pressure Release Valve, Water Level Indicator & drain Valve, Size -350 x550mm (14”*22”) Capacity - 50 liter, Load 3 Kw.
Spectrophotometer Optical System: Double Beam, UV VIS Wavelength Range : 190-1100nm Mode : Basic/Quantitative/Wavelengthscan), DNA Protein Test/Kinetics Scanning Speed : Fast/ Medium/ Low Bandwidth : 1nm, Tungsten lamp Wavelength Accuracy : ± 0.3nm Wavelength Repeatability : 0.2nm Photometric Accuracy : ± 0.3%T Light Source : Deuterium, Tungsten – Halogen, Xenon Lamp
Flame Photometer Na 0 to 100 ppm, K 0 to 100ppm, Ca 15 to 100 ppm, Li 10 to 100 ppm Sensitivity: 5 ppm -10 ppm, Readout 21/2, Digit Bright Red LED Display. Accuracy +-2%upto 40 ppm, +-5% above 40 ppm Auto Ignition, Measure one element at a time, Repeatability +- 2 Count Detector Silicon Photo Diode Filters Narrow Band Interface Glass Filters, Nebulizer Black Bakelite, Axial Flow Type, Flame System LPG and Dry oil free air, Warm up time 10 Minutes with Air Compressor
Water bath Incubator shaker Cooling, Digital, Double wall, Inner SS304, Outer MS Powder Coated, Shaking speed 40 to 140 Cycles pm, shaking tray to hold Flasks 25 /50/100/250 or T Tube, Temp. 50C to 600C +-10C
Dry bath Temp. settings range : -10oC~100oC Temp. accuracy : ≤±0.3oC Temp. uniformity : ≤±0.3oC Timing range: 1min ~ 99h59min/∞ Multi points running: Yes (Max 5points)
Conductivity Meter Digital Digital LED display 31/2 Digit in 5 ranges with temperature sensor, conductivity cell, 0-1000ms in 5 range. Conductivity Accuracy : ±1% F.S Temperature Range : 0~100°C Temperature Compensation : 0~50°C, Automatic or Manual.
Convection Microwave Oven Minimum 10L Capacity, Touch Key Pad, Quartz heater, Concealed Heating & Stainless steel cavity.
Trinocular Research Microscope Illumination: Light source: X-LED3; light intensity control using a knob on left side of the frame. LED power: 3.6W, comparable to a 35W halogen bulb. Color temperature: 6300K, LED average lifetime: 50000h. Power supply: Input 110/240Vac, 50/60Hz; Output 6Vdc 1A, Max. required power: 6W, Observation modes: Brightfield, Upgradability: 1, 2, 4 Filter Fluorescence Attachment, Phase Contrast Attachment, Polarization & Multi Head Attachment, Focusing: Coaxial coarse and fine focusing mechanism (graduated, 0.002mm) with upper stop, to prevent the contact between objective and specimen. Flat fine focusing knob on the right side. Adjustable tension of coarse focusing knob. Stage: Double layer with mechanical sliding stage, size 175x145, X-Y movement range 78x54mm. Belt-drive in X direction. Anti-scratch surface. Vernier scale on the two axes, accuracy 0,1 mm. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Head: Biinocular observation head, inclined 30° and rotatable 360°. Diopter adjustment on left eyepiece. Interpupillary adjustment 48-75 mm. Eyepieces: Widefield eyepieces WF10X/20 with field number 22. Objectives: Infinity E-PLAN objectives: E-Plan IOS 4X, N.A. 0.10, W.D. 16.8 mm, E-Plan IOS 10X, N.A. 0.25, W.D. 5.8 mm, E-Plan IOS 40X, N.A. 0.65, W.D. 0.43 mm, E-Plan IOS 100X, N.A. 1.25, W.D. 0.13 mm (oil immersion), All objectives have anti-fungus treatment. Condenser: Abbe condenser, sliding-in, N.A. 0.90 with centering system. Accessories: Instruction manual and dust cover should be included. CAMERA SPECIFICATION: Digital camera resolution 6.3 Mega Pixels (3072 x 2048), Signal output USB3.0, Sensor Size 1/1,8” Sensor technology CMOS, Image format 4/3, Pixel size 2,4 x 2,4 microns, Frame rate full resolution, 30 fps (3072 x 2048) Frame rate other resolutions, 38 fps (1536 x 1024), Sensitivity 425 mV at 1/30sec, Dark signal 0,15 mV at 1/30sec, Color Depth 8 Bit - 12Bit, Exposure Time, 0.1 msec - 15 sec, Binning 1x1; 2x2, IR fi lter 380-650 nm (IR-cut fi lter), Camera power PC USB, C-mount, OS WINDOWS / Mac OS X / Linux. ACCESSORIES, CS-mount, Optical adapters, Calibration Slide, 3,0 m USB cable, Installation manual, CD rom. SOFTWARE SPECIFICATION System requirements Windows XP / Vista / win7 / win8 / 32-64 bit / usb 2.0, Capture features Continuous auto white balance, continuous auto exposure, averaging, subsampling, image capture, extended exposure, Control parameters Brightness, goal brightness, gain, gamma, exposur time, colors set, contrast, saturation, flip.
Backup Batteries Dry 29 batteries backup system of 10 KV
Electronic weighing balance IS mark, Capacity: 220g, Resolution: 0.1 mg, Class type: I, Display: LCD, Speed of measurement: 2 second, Automatic tare provision, mains operated power requirement, single phase power supply, EMFC sensing element, 12 Voltz
Coloured printer: Printer Type – Office Jet; Functionality - All-in-One (Print, Scan, Copy) , Scanner type – Flat bed; Printer Output – Colour, Connectivity - USB, Wi-Fi, Wi-Fi Direct, Ethernet, HP Smart App, Page size supported - A4, A5, A6, B5, C5, C6, DL envelope ; Duplex Print - Automatic ; Print resolution - Up to 4800 x 1200 optimized DPI (Colour), Up to 1200 x 1200 rendered DPI (Black) ; Auto-Document Feeding feature ; Compatible Ink Cartridge - HP 965 Black, Yellow, Cyan, Magenta Original Ink Cartridges - One of each comes free with the printer; Yield - 2000 pages (Black & White), 1600 pages (Colour), Duty Cycle (Maximum monthly recommended prints) - Up to 30,000 pages per month
Elab Solution
The Scientific Suppliers
The Chemical Center
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .