| 1 | L1₹26.8 LAccepted-AOC NETAJI COLONY WARD NO 36 SILIGURI 734 006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | ₹26.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.5 LRejected-Finance RAJA RAMMOHAN ROY ROAD SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | ₹27.5 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹27.9 LRejected-Finance H 65 8 127 58 SURYA NAGAR SILIGURI 734 006 | SILIGURI | JALPAIGURI | WEST BENGAL | 734006 | ₹27.9 L | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M/S KUMAR ENTERPRISE L3 | M/S. P K ENTERPRISE L2 | M/S S.T. HIGH VOLTAGE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing Window / Split type RAC machine carefully from its original location and covering this exsisting position by acp/Eboard & including carying & deposited to section store as instructed by the EIC | 28 | Each | 500 ₹14,000 | 400 ₹11,200 | 355 ₹9,940 |
| 2.00Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required | ||||||
| 2.10 | i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 476 | RM | 200 ₹95,200 | 200 ₹95,200 | 188 ₹89,488 |
| 3.00Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc.including supplying sockets. | ||||||
| 3.10 | a) 2.5 sq mm. | 50 | set | 8 ₹400 | 10 ₹500 | 7 ₹350 |
| 3.20 | b) 4.0 sq mm. | 100 | set | 9 ₹900 | 10 ₹1,000 | 8 ₹800 |
| 4.00 | Supplying and fixing 240/415V, 16A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. | 28 | Each | 250 ₹7,000 | 244 ₹6,832 | 240 ₹6,720 |
| 5.00 | Supplying and fixing 25 A OLP - 3+ A.C Starter making necessary connection with PVC cu wire and earth continuity wire incl S & F of 175mm x 100mm GI box flushed in wall with voltage check, Amp check, incl. all connection & mewnding good the damages. (Make- Electron OLP3 +) | 28 | Each | 1,875 ₹52,500 | 1,910 ₹53,480 | 1,865 ₹52,220 |
| 6.00 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc | 28 | Each | 465 ₹13,020 | 453 ₹12,684 | 450 ₹12,600 |
| 7.00 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections | 28 | Each | 167 ₹4,676 | 163 ₹4,564 | 160 ₹4,480 |
Tender Value
Refer Docs
EMD Value
₹53,000
Closing Date
4 Dec 2025, 12:00 pmClosed
EE/DED
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Replacement of AC Machine more than 10 years old by new AC Machine along with ancillary EI work at Siliguri District Hospital, Darjeeling.
2025_WBPWD_945227_1
WBPWD/EE/DED/e-NIT-44 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
30 days
SILIGURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹53,000
Yes
12 May 2026
12 Nov 2025
8 Dec 2025
12 Nov 2025
4 Dec 2025
12 Nov 2025
Amount
Dismantling the existing Window / Split type RAC machine carefully from its original location and covering this exsisting position by acp/Eboard & including carying & deposited to section store as instructed by the EIC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc.including supplying sockets.
a) 2.5 sq mm.
b) 4.0 sq mm.
Supplying and fixing 240/415V, 16A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS.
Supplying and fixing 25 A OLP - 3+ A.C Starter making necessary connection with PVC cu wire and earth continuity wire incl S & F of 175mm x 100mm GI box flushed in wall with voltage check, Amp check, incl. all connection & mewnding good the damages. (Make- Electron OLP3 +)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections
S&D of minimum High Wall inverter type Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with Rotary Compressor with minimum Cooling Capacity of (6.6KW-7.00 KW), Air flow rate (630-875) CFM, suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wireless remote & all other accessories complete with refrigerent with 25 A Plug Top (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/Sharp/ Mitsubishi Heavy/Voltas)i) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas)
Installation, testing & commissioning of 1/1.1/1.5/1.8/2/2.2 ton AC machines complete with outdoor condensing unit on iron angle / powder coated bracket & indoor cooling unit on wall with suitable bracket . Rate is inclusive of cutting of wall for making holes and mending good the damages.
REFRIGERANT PIPING:- Supply and drawing 5/8" & 3/8" or 1/2" & 1/4" copper refrigerant pipes with 9 mm thick rubber nitrile rubber insulation an Al foil tape complete fittings Elbows, Bends, Supporting arrangement on walls along with other accessories on the surface of wall
DRAIN PIPING Supply & laying drain Water piping work out of UPVC/ HDPE hard pipes (Make HB / Supreme / Oriplast) incl. fitting , accessories bends, elbows, tees, flanges, tapings, etc. 20mm hard PVC pipe (heavy type) for water drainage.
Supply & fixing of SPN DB (2+10) with IP 43 protection, powder coated, provision for housing DP Contactor, concealed in wall after cutting the wall & mending good the damages to original finish/ on flat iron frame incl painting, connection & provision for earthing attachment incl. following accessories. [Make:Legrand /Schneider /Siemens /Crabtree/ L&T]
i) 40 A DP MCB Isolator -1no
ii) 25 A double pole Contractor ML1.5 -1no.
iii) Programmable Digital time switch -1no.
iv) Toggle Switch-1No
v) LED indication lamp- 1 set (1 Red & 1 Green)
vi) 16A SP MCB-1 no.
with complete interconnection and locking arrangement as per direction of E.I.C.
S & F of 3 core 4 sq.mm. PVC Cu cable for connection between indoor & outdoor units (Make: Polycab/ Finolex/ KEI/ Gloster)
S & F of 4 core 2.5sq.mm. PVC Cu cable for connection between indoor & outdoor units (Make: Polycab/ Finolex/ KEI/ Gloster)
M/S. P K ENTERPRISE (BID ID -7535621)
M/S KUMAR ENTERPRISE (BID ID -7431135)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
WBF2911.pdf
Tender Documents • 0.50 MB
BOQ_2245701.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid