Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | ₹30.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹30.1 L+₹18,849 (0.63%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | ₹30.1 L+₹18,849 (0.63%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹31.2 L+₹1.3 L (4.30%)Rejected-Finance | ₹31.2 L+₹1.3 L (4.30%) | L3 | Rejected-Finance REJECTED |
| 4 | L4₹32.8 L+₹2.9 L (9.64%)Rejected-Finance D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹32.8 L+₹2.9 L (9.64%) | L4 | Rejected-Finance REJECTED |
| 5 | L5₹34.4 L+₹4.4 L (14.8%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | ₹34.4 L+₹4.4 L (14.8%) | L5 | Rejected-Finance REJECTED |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Aug 2021, 6:00 pmClosed
GE Seervices
GE Seervices. visakhapatnam
MANNING OPERATION of RO PLANTS and COMPREHENSIVE MAINTENANCE of RO PLANTS, REPAIRS REPLACEMENT TO EXTERNAL WATER SERVICES, AIR-CONDITIONING AND WATER COOLERS AT AOB RAMBILLI V
2021_MES_460404_2
GE(S)/T06 of 2021-22
Open Tender
Electrical and Maintenance Works
Works
335 days
GE Seervices
Please ref as per Tender douments
7 documents required · 7 mandatory
₹500
DGNP V
₹80,000
24 Sept 2021
30 Jul 2021
14 Aug 2021
30 Jul 2021
13 Aug 2021
30 Jul 2021
30 Jul 2021 - 30 Jul 2021
Amount
RO Plants
Manning and operation of water supply pumps, DG Sets (160 kVA- 02Nos, 100 KVA -01 No & 10 kVA- 01No) and RO Plant (600 LPH & 1000 LPH) at Rambilli premises by one FGM & one Helper including minor repair work to be carried out in pump house, RO Plant and DG sets by technician for eight hours shift (Pumping of raw water and treated water supply to be feed as per scheduled timing, DG Sets to operate during the uninterrupted power supply and technician to be maintained Reverse Osmosis plant, make- ROCHEM/TECHNO AQUA Separation systems and trouble free operation of the plant with correct quality of portable water discharge as per standred norms) Note:- Nos. of Person required :- 02 persons (01 FGM (Skilled) + 01 Helper (Un-Skilled) 3 shift per day Ist shift (0600 Hrs to 1400 Hrs) = 01 FGM & 01 Helper IInd shift (1400 Hrs to 2200 Hrs) = 01 FGM & 01 Helper IIIrd shift (2200 Hrs to 0600 Hrs) = 01 FGM & 01 Helper
Comprehensive Maint of RO plants, any capacity checking the function complete, descalling the membarines, active carbon filter, mechanical filters, replacing of O-Ring, seals, gland packing complete ensuring for the proper outlet quality of potable water complete all as specified and directed by Engr-in-Charge. Technician should be checking the RO Plant every 15 days (twice in a month) or upon complaining by operator and serviceability report to be submitted to Engr-in-Charge. Replacement of spares will be paid and measured separately Note:- 1.Comprehensive maintenance to be done through authorised Maintenance of RO firm and necessary maintenance certificate to be submitted. 2. Each visit will be consdiered as one unit. 3. Dilute hydro chloric acid required deemed to be inclusive of quoted rate.
Supply and fixing of spares and taking out unserviceable all as specified and directed by Engr-in-Charge. NOTE:- Replacement of any other spares other than the listed below (major/minor) if required shall be done by the contractor without any extra cost to the Govt. The list given below is not exhaustive and contractor has to ascertain the actual requirement of spares/ consumable while quoting his rate. However contractor shall not have any further claim in this regard at a later stage.
Feed pump seal
Multiport valve
Pre filter
Carbon media
High pressure pump seal
Needle valve
Control panel
Sand media
Solenoid valve
Fuse for dosing pump
Filter Media per month
Activated carbon filter
Antiscalant for RO plant (60 liter container - 01 No.)
Sodium Hypo Chloride (60 liter container - 01 No.)
Food grade pH enhancer
Filter of 01 KLD 02 No and 02 KLD 01 No
M & L for Repair/replacement to RO plant 600 LPH by replacing DT modules complete with all fitting and fixtures complete all as specified and diected by Engineer in charge.
M & L for Repair/replacement Repair to RO plant 600 LPH by Repair/replacing of HP motor pump, 1 HP capacity, complete with all fitting and fixtures complete all as specified and diected by Engineer in charge.
M & L for replacement of three plungers of 1/3 HP,4000lph 340 Rpm, 3 Phase, 415V three plunger reciprocating pump, 300/45 of 1000 LPH RO plant by replacing ceramic coating plunger,piston oil seal, oil gasket, gland ring, gland rope 6 mm dia, stuffing box gasket, valve spring, o ring, header block stud, nut & washers, lub oil and gland spring also replacing DT modules etc including testing complete all as specified and directed by engineer in charge.
Contractor to be provide complete water analysis of water as per IS: 10500 : 2012, Certified from Govt approved Lab (NABL ACcredated) Some of the parameters given are as under below inclusive and not limited to and also certificate of potable drinking water to be submitted for the same complete all as specified and directed by Engr-in-Charge
(1.1) Chemical Analysis: (a) pH value (b) Electrical conductivity (c) Turbidity (d) TDS (e) TSS (f) Hard ness (g) Iron (h) Chlorides (j) Fluorides (k) Magnesium (l) Sulphate (m) Nitrate (n) Total alkalinity (o) Residual free chlorine (1.2) Chromium (Heavy metal in ground water) (1.3) Bacteriological parameters (a) Total Coliform (b) Faecal Coliform (c) E.Coli
Supply of and replacement of 8" membranes -03 Nos of suitable size to the 1000 lph RO plant complete all as specified and directed by Engr-in Charge. Note : The labour for fixing the membranes included in the Sch A item Sl No.03
DG SETS : Servicing of DG set capacity 100 to 160kVA and taking out the defective/unserviceable parts and re-assembling the same after repair/replaced and testing complete all as specified and directed. (Note : spare parts shall be measured and paid separately as supply only here in after).
Diesel filter
Oil filter
Oil pressure gauge
Hose pipe set with clamps & clips complete
Ampere meter
Volt meter
Air filter
Fan belt
Repairing of self starter by replacement & bearing, field coil, GM bushes varnishing & testing as directed.
Repair & over hauling of injector Nozzle including calibration 100-160 KVA DG set in authorised factory and testing by pressure machine on required pressure as specified & directed.
All as per item No. 27 above but DG set 10 KVA, (Note :-spare parts shall be measured and paid separately as supply only here in after)
Diesel filter
Oil filter
Hose pipe set with clamps & clips complete
Air filter
Fan belt
Ampere meter
Volt meter
Repair & over hauling of FIP including replacement of defective parts as required including calibration in authorised factory/dealers & testing complete all as specified and directed by Engineer-in-Charge.
Repairing of dynamo including replacement of armature field coil, GM bushes, heating, varnishing, testing complete all as directed.
Taking out carefully unserviceable fuel injector pump assembly of 160kVA DG set of 1500 RPM Make:- CUMMINS/KIRLOSKAR/KEC/CROMTON, cleaning/ oiling/servicing fuel injector pump assembly , recalibration of Fuel Injector Pump after replacing unserviceable nozzles/Bearing bush with roller/ Delivery valve with washer and spring/Roller Bearing. /Bearing end plate etc.,re-assembling and fixing the same in position and testing the Fuel Injector Pump assembly all as specified and directed by Engineer-in-Charge.
Supply & replacement of maintenance free battery of capacity 12V 180 AH battery terminal complete all as specified and directed by EIC.
Supply and filling lubrication oil SAE-40 ( 20 W- 40 grade) of Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE.
Replacement of asbestos ropes with new asbestos rope of existing size of exhaust pipe 160 kVA D.G. Set.
Replacement of asbestos ropes with new asbestos rope of existing size of exhaust pipe 7.5 to 10 KVA D.G. Set.
Dismantling of oil sump and decanning old engine oil from DG set upto 7.5 kVA to 10 kVA capacity and cleaning the oil sump chamber by removing settled particals, sludge etc for pressure vacume including rectify the leakage by welding including refixing the same by replacement new nuts, bolts clamps all as specified and directed.
Dismantling of oil sump and decanning old engine oil from DG set upto 160 kVA capacity and cleaning the oil sump chamber by removing settled particals, sludge etc for pressure vacume including rectify the leakage by welding including refixing the same by replacement new nuts, bolts clamps all as specified and directed.
Disconnecting, and taking out carefully old unserviceable rectifier of any make and capacity,suppling and fixing new rectifier of existing make suitable for 7.5 kVA to 160 kVA DG set complete all as specified and directed.
EXTERNAL WATER SUPPLY
Taking out defective submersible openwell pump set of capacity 7.5HP from open well/UG sump for repair by lifting GI tubing of size 65 mm from up to 40feet to 10 to 15feet depth after disconnecting electrical and pipe line connection, complete by means of chain pully block or other T & P, transporting to workshop including repair/replacement of worn out parts, servicing and overhauling complete with oilling/greasing, lubricating the parts and reassembling and painting of submersible pumpset with motor with one coat of synthetic enamel paint after clearing and scrubbling and shifting back to openwell/ UG Sump, lowering commissioning and testing on full load complete all as specified and directed by Engineer-in-charge. Note:- (i) The rate quoted for this item shall includes labour charge only for maint repair and replacement of defective / UNSV spares / accessories. Spares are to measured and paid separately under subsequent items. (ii) Cost of other minor items/spares such as nut, bolts washers, gaskets, paints etc which are not covered under Sch 'A' but required for effective functioning of the plant shall be deemed to included in this item.
Supply only following items / parts for 7.5HP submersible openwell pump set.
(a) Thrust bearing
(b) Gun metal bearing bush.
(c) Stainless steel studs and nuts
(d) Impeller
(e) Seal
(f) Impeller key
(g) Rotor sleeve
Replacement of PVC water tank of 10000 Ltrs cap, rotational moulded polyethylene water storage tank (cylindrical vertica with closed top) hoisted and fixed in position including dismatling of existing tank with complete all as specified directed by Engr-in-Charge.
Dismantling the motor of submersible openwell pumpset of capacity 7.5HP, removing the existing burnt out winding and rewinding with PVC copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and filling of cooling oil with oil seal and terminal lead for AC, 3Phase, 415volts grade and other petty items required for making motor functional and motor reassembling and testing with complete all as specified directed by Engr-in-Charge.
Desilting of open /shallow well dia of 25 feet and 25 feet depth at Rambilli premises by bailling out of water from the well through pump set, removing the silt (mud/sand etc) from the floor of the wells and deposting not exceeding 50 metre, cleaning the inside vertical surface of the wells with wire brushes including removing the large growth and removing the large floating of suldge on the water completely including one coat of wash of inner surfaces with complete all as specified directed by Engr-in-Charge.
Taking up of unserviceable / rusted tubing and connections of 15mm bore from excavated trench / walls / floors / ceiling etc complete all as directed.
All as per item No. 69 herein before but for 20 mm bore pipe
All as per item No. 69 herein before but for 25 mm bore pipe
All as per item No. 69 herein before but for 40 mm bore pipe
All as per item No. 69 herein before but for 50 mm bore pipe
Supply and laying GI tubing of 15 mm bore galvanized medium grade of any length including all fittings such as bend, elbow, tee and union on floors/ walls/ceilings with complete all as specified directed by Engr-in-Charge.
All as per item No. 74 herein before but for 20 mm bore pipe
All as per item No. 74 herein before but for 25 mm bore pipe
All as per item No. 74 herein before but for 40 mm bore pipe
All as per item No. 74 herein before but for 50 mm bore pipe
Supply and laying GI tubing of 15 mm bore galvanized medium grade of any length including all fittings such as bend, elbow, tee and union in trenches with complete all as specified directed by Engr-in-Charge.
All as per item No. 79 herein before but for 20 mm bore pipe
All as per item No. 79 herein before but for 25 mm bore pipe
All as per item No. 79 herein before but for 40 mm bore pipe
All as per item No. 79 herein before but for 50 mm bore pipe
Cutting the existing GI steel tubing 25mm bore and screwing the cut ends (or length) screw on pipe to form connector in trenches, floors or on walls and ceiling for alterations or addition and rejointing including connecting up with GI union with complete all as specified and directed by Engr-in-charge
All as per item No. 84 above but for 40mm bore pipe
Replacement of unserviceable gun metal globe or gate valve of brass heavy duty ISI marked with iron wheel head, butterfly handle screwed both ends for iron pipe of 15 mm bore complete in place of all as directed fixed in wall and groundwith complete all as specified and directed by Engr-in-charge
All as per item No. 86 here in before but for iron pipe of 20mm bore
All as per item No. 86 here in before but for iron pipe of 25mm bore
Cutting the existing damaged 50mm dia GI/HDPE pipe line in position supply and inserting by reducing the dia of pipe tee/elbow testing including necessary earth work in sludgy soil, dewatering and refilling the same in layers with complete all as specified and directed by Engr-in-charge
M & L for construction of brick masonary (230 mm thick wall) valve pipt of size 450 x 450 x700mm inner dimension including necessary earth work , PCC 1:4 8, 75 mm thick Type D-2 using 40 mm graded stone aggregate as in foundation , brick wall build in CM 1:6, rendering 15 mm thick with CM 1: 6 externally upto 15 CM below GL and CM 1:4 internally and providing MS Sheet cover 3.15 mm thick welded with hinges including necessary locking arrangement and complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level)with top edge of earth plate not less than 1.5 mtr below GL connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part I connecting to earth points and testing on completion with and including 15 mm bore light grade GI protection pipe (7.5 mtr long) for earth lead including P C C 1:2:4 type B1 chamber pit with pre cast R C C1:2:4 type B1 cover slab40 mm thick reinforced with 6 mm dia MS bar C/C 100 mm both ways with lifting hook made out of 6 mm dia MS rod, watering arrangement with GI light grade 20 mm bore watering pipe with funnel, wiremesh, common salt, charcoal filling necessary excavation in any type of soil with complete all as specified directed by Engr-in-Charge.
Replacement of submersible PVC insulated cable of 650/1100 volts grade 3 core 6sqmm with flexible copper conductor water resistant quality ISI marked in replacement with complete all as specified directed by Engr-in-Charge.
Replacement of PVC water tank of 1000 Ltrs cap, rotational moulded polyethylene water storage tank (cylindrical vertica with closed top) hoisted and fixed in position including dismatling of existing tank with complete all as specified directed by Engr-in-Charge.
Replacement of HDPE pipe 50mm bore of pressure rating 6kgf/sqcm laid in trenches including connected accessories with complete all as specified directed by Engr-in-Charge.
All as per item No. 94 herein before but for 32 mm bore pipe
All as per item No. 94 herein before but for 25 mm bore pipe
Replacement of ball brass valves 25mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed by Engr-in-Charge.
All as per item No. 97 herein before but for 20 mm bore pipe
Supply and fixing PVC connection 15mm dia 450mm long including clamps and nuts all as specified.
AIR CONDITIONING & REFRIGERATION
Servicing/repairing of the following cooling appliances from its existing position and refixing of the same after repairing including/cleaning filter removing internal dust by using air blower and vacuum cleaner, oiling, greasing wherever required including checking / testing after completion all as specified and as directed. Note : Unserviceable/defective items which is required to be replaced shall be measured and paid separately.
Water coolers 120/80 ltr & 120/150 ltr
Split type AC 1.5 ton/2 ton capacity
Window type AC 1.5 ton/2 ton capacity
Refrigerator 165/310 ltr capacity
Deep Freezer
The chemial servicing of 11 TR conderser unit by descaling agent diluted HCL for outdoor units (condensers) and filter cleaning for indoor units of the same complete all as specified and directed by Engr-in-Charge.
Finding the leakage in refrigerant system by nitrogen pressure test etc and rectifying the leakage by brazing including installation and complete testing of the following cooling appliances with complete all as specified directed by Engr-in-Charge.
Water cooler 120/80 ltr & 120/150 ltr
Split type AC 1.5 ton/2 ton capacity
Window type AC 1.5 ton/2 ton capacity
Refrigerator 165/310 ltr capacity
Deep Freezer
All as per item No. 108 but of package type Ac plant 11TR Indoor/Outdoor units
M&L for Charging of refrigeration gas (R-22/134a/ HCFC/R407/R404 etc ) to existing Window AC/ Split AC /Deep Freezer/Deepe/Refrigerator/Package type AC of any description, any make & in any position to makeup required pressurewith complete all as specified directed by Engr-in-Charge.
M&L for replacement of the following parts/items of split/window type AC 1.5 ton / 2.0 ton capacity, water cooler 80 ltr / 150 ltr capacity, refrigerator 165 ltr / 310 ltr capacity, and desert coolers etc complete all as specified and as directed.
Starting capacitor of 80/100 mfd capacity Make: Asian/Keltern/Unistar/EPSCO/Keal
Starting capacitor of 100/120 mfd capacity Make : Asian/Keltern/Unistar/EPSCO/Keal.
Running capacitor of 4.5 MFD
Running capacitor of 30 MFD/36 MFD capacity .Make : Asian/Keltron/Unistar/EPSCO/Keal
Starting capacitor of capacity 10 MFD/20MFD. Make : Asian/Keltern/Unistar/EPSCO/Keal
Running capacitor of 4 MFD. Make : Asian/Keltron/Unistar/EPSCO/Keal
Thermostat switch for water cooler Make : Renutral/Shriram/Indfoss
All as per item No. 116 above but AC 1.5 ton/2.0 ton capacity, Split/window type Make : Renutral/Shriram/Indfoss
All as per item No. 116 above but for Refrigerator.
Wiring kit for water cooler
window type / split type AC
PVC air filter for split AC
PCB for Cooling Only 2/1.5 TR Split Ac.as per existing make
Brass service valve for split type A/C of size 5/8” or 3/8'' dia service valve all as approved.
Refrigerator Freezer coil & freezer coil type/roll bound type complete suitable for 165 ltr. to 230 ltr. capacity
Brass Nipple 15 mm dia for inlet and out let connection of water cooler
Drain Pipe PVC flexible 1¼” dia with one end circle clip
CP brass Push cock, 15 mm. Dia.
M&L for replacement of 3 core flexible copper cable of size 40/0.0076 with thimble etc complete all as specified and as directed.
S&F in repair plug top 3, pin 5 Amp complete all as specified
S&F in repair plug top 3, pin 15 Amp complete all as specified
M&L for replacement of burnt compressor including dismantling the unserviceable burnt after disconnecting suction/discharge side copper tube bolts rubber pads and washers connecting copper tubing by welding blazing nut flaring and repairing of gas leakage if any and complete in the following cooling appliances all as specified and as directed.
Water cooler 80-150 ltr per hours cooling capacity.
Window type AC/split type AC of 1.5 ton capacity
Split type AC 2.0 ton capacity
Refrigerator 165 ltr capacity
Refrigerator 310 ltr capacity
Deep Freezer 200 to 315 ltr capacity
M&L for replacement of blower fan motor of existing size and capacity in cooling unit of split type AC capacity 1.5 TR/ 2.0 TR complete all as specified and as directed by EIC.
M&L for replacement of Condensor fan motor of existing size and capacity in outdoor unit of split type AC capacity 1.5 TR/ 2.0 TR complete all as specified and as directed by EIC.
M&L for replacement of cooper tube of size 1/4" or 3/5'' dia for cooling unit to condensing unit for split Acs all as specified and as directed by EIC.
Ditto all as per item No.147 above but of size 1/2'' or 5/8" dia
M&L for replacement of insulation for cooper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split Acs all as specified and as directed by EIC.
M&L for writing/making SL, SM, MES Nos with black/white paint with stencil on indoor and outdoor unit of split Acs window type Acs water cooler desert coolers, stabilizers of any make and any c capacity all as specified and as directed by EIC.
M&L for replacement of metal clad socket outlet 3 pin of capacity 20 Amps 240V complete all as specified and as directed.
M&L for replacement of metal clad plug top of capacity 20 Amps, 240V complete all as specified and as directed.
M&L for condenser of refrigerator of capacity upto 310 Ltrs incl taking down old unsrvicable and refixing the same with necessary nut and bolts with complete all as specified and as directed.
M & L for replacement of UV system suitable to 1000 LPH complete all as specified and directed by E-in-Charge
M&L for repair/replacement rusted body, supoort base plates, water tray etc of tinkering of water coolers of capacity upto 120/150 ltrs and necessary nut and bolts with complete all as specified and as directed.
M&L for replacement of float valve 15mm bore of brass with L type nipple & polythene float valve complete all as specified and as directed.
GVR CONSTRUCTIONS
SAI ENGINEERING WORKS
P VENKATA RAO
MONITOR ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .