Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC | ₹19.5 L Quoted ₹22.4 L | L1 | Accepted-AOC Being reasonable |
| 2 | L2₹33.5 L+₹11.1 L (49.8%)Rejected-Finance | ₹33.5 L+₹11.1 L (49.8%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹39.4 L+₹17.1 L (76.4%)Rejected-Finance 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | ₹39.4 L+₹17.1 L (76.4%) | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Sept 2024, 6:00 pmClosed
GE (KH) YOL
GE (KH) YOL, YOL CANTT, HP
Repair/Maint of Voltage stabilizer, DG sets, lightening conductor, misc items and Repair/replacement and maint of distribution transformer, switch gears and connected works at Yol Cantt
2024_MES_669348_1
GE/Y-62/2024-25
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (KH) YOL
₹80,000
Yes
18 Oct 2024
31 Aug 2024
28 Sept 2024
31 Aug 2024
27 Sept 2024
14 Sept 2024
Amount
PART-I: Servicing, overhauling and periodical maintenance of DG sets of following capacity including cleaning internal parts thoroughly, replacement oil filter, fuel filter, air cleaner, turbo charger etc making smooth valve seats of inlet and exhaust valves including replacement of minor parts such as nut, bolts, washers, banjo nut, bolts, washers, locking nuts, circle clips, `O’ Rings, Gasket, main cylinder head joint screws, stud small springs as deemed necessary or ordered complete and reassembling after replacement of unserviceable parts including painting with one coat of synthetic enameled paint of existing color after removing dust, dirt and oil by caustic soda etc, commissioning and testing on connected load complete specified and directed by Engr-In-Charge. (Note : The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced spare parts which are catered in schedule for supply only shall be measured and paid for separately. however essential parts/work which is required for sound engineering practice will be deemed to include in the coated rate of this item).
(a) DG set of Capacity 20/32.50/35 KVA.
(b) DG set of Capacity 62.50 KVA.
(c) DG set of Capacity 100/125 KVA.
(d) DG set of Capacity 200 KVA.
Supply only of the following items/spare parts to be incorporated in DG Sets against item No 1 here-in-before.
Lubricant oil filter element complete with plane washer, 'O' ring etc . Make-Mico/flit guard/donalson (a) DG set of Capacity 20/32.50/35 KVA.
(b) Ditto all as per item No. 2.01 but DG set of Capacity 62.50 KVA.
(c) Ditto all as per item No. 2.01 but DG set of Capacity 100/125 KVA.
(d) Ditto all as per item No. 2.01 but DG set of Capacity 200 KVA.
Micro Super Fuel filter & Pre filter element complete with plane washer, 'O' ring etc. Make-Mico/flit guard/donalsona. (a) DG set of Capacity 20/32.50/35 KVA.
(b) Ditto all as per item No. 2.05 but DG set of Capacity 62.50 KVA.
(c) Ditto all as per item No. 2.05 but DG set of Capacity 100/125 KVA.
(d) Ditto all as per item No. 2.05 but DG set of Capacity 200 KVA.
Air filter element complete with plane washer, 'O' ring etc. Make-Mico/flit guard/donalson (a) DG set of Capacity 20/32.50/35 KVA.
(b) Ditto all as per item No. 2.09 but DG set of Capacity 62.50 KVA.
(c) Ditto all as per item No. 2.09 but DG set of Capacity 100/125 KVA.
(d) Ditto all as per item No. 2.09 but DG set of Capacity 200 KVA.
Draining-out old spoiled lubrication oil from DG Sets of 10 to 200 KVA capacity, cleaning thoroughly the sump including supply and filling lubrication oil SAE-40 into the chamber/sump all as specified and directed by Engr-In-Charge. Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL
Supply and fixing flexible pipe, filter to lub oil cooler including banjo bolt washers, copper asbestos washer, spring washer nuts and bolts for DG set of Capacity 20 to 200 KVA complete all as specified.
M&L for rewinding of alternator with `F' class copper wire as per existing gauge after dismantling the old coil cleaning throughly and winding with super enameled copper conductor of existing size and gauge, varnishing drying complete including transportation from site to workshop and back after repairing and refixing the same in DG set with testing DG set Capacity upto 200 KVA, complete all as specified and directed by Engr-in-charge.
Disconnecting and taking down old unserviceable self starter for DG set Capacity upto 200 KVA, 12Volt and dismantling, complete for repair and replacement of the Following parts :- (a) Armature – 01 No (b) Solenoids switch – 01 No. (c) Field coils – 01 No. (d) Commentator – 01 No. (e) Carbon brush – 02 Nos. (f) Bendex assembly – 01 No.
M&L for complete wiring of DG Set control panel with suitable existing size of copper multistranded wire of any core incl taking down old unsv wiring of Capacity 20-200 KVA, complete all as specified and directed by Engr-in-charge.
Supply and fixing in repalacement of Power Contactor 4 Pole 60 Amp AC-1 rating, 2NO+2NC arrangement, 440 volt, complete all as specified and directed by Engr-in-charge.
M & L for Door joint and handle locks arrangement for any size/capacity DG set, complete all as specified and directed by Engr-in-charge.
Supply and fixing brass terminal for batteries including taking out and removing existing unserviceable terminals, complete all as specified and directed by Engr-in-charge.
Dismantling complete radiator assembly, cleaning and de-scaling of choked water tubes and jackets of radiator, cleaning the fins of radiator with acid including brazing of worn out copper tubes, body and fins and making complete the water body leak proof and testing by pressure including replacement of the worn out minor spares such as plain washers, spring washers, screws nuts, bolts, joints, rubber hoses with clip etc, complete all as specified and directed by Engr-in-charge.
Material and labour for top up coolent for DG sets complete all as specified and directed. Make: CASTROL - RADICOOL HEAVY DUTY COOLANT or Equivalent of SERVO, VEEDOL
Supply and fixed in replacement maintenance free battery duly initially charged 12 volt 180 AH, complete all as specified and directed by Engr -in-charge. Make: Exide/Amaron/TATA Green.
Supply and fixed in replacement maintenance free battery duly initially charged 12 volt 150 AH, complete all as specified and directed by Engr -in-charge. Make: Exide/Amaron/TATA Green.
Supply and fixed in replacement maintenance free battery duly initially charged 12 volt 120 AH, complete all as specified and directed by Engr -in-charge. Make: Exide/Amaron/TATA Green.
Supply and fixed in replacement Over current relay definite time Non directional, definite time & current adjustable setting 0.5 -5A 1-10A /0.1-1A time 0-10 sec of exzisting make Teknika Type TE 510 internal.
Supply and fixed in replacement auto cut switch up to 63 KVA as per existing make all as per directed bt Engr-in-Charge.
Supply and fixed in replacement Solenoid switch 12 volt. Make :- Kirloskar
S&F in replacement Automatic Changeover switchs of capacity Upto 100 Amps operated 415V, 50 Hz conforms IS/IEC 60947-1 & 3 Make :- Havells/Standard/L&T
Disconnecting all incomming /outgoing electric conenction carefully of fully automatic servo voltage stabilizer having capacity 20 to 100 KVA and transport to work shop for repair/servicing and including, dismantling top cover of stabilizer and taking out the coil, drain out the transformer oil and refilling after dehydration of transformer oil, cleaning internaly, including replacement of unserviceable body nuts, bolts, washers, top gaskets of cork sheet 6mm thick, replacement of internal circuit wiring if any suitable size of copper wire and painting of stabilizer with heat resistant smoke grey synthetic enameled paint including preparation of old rusted surfaces and writting MES NO, SM MES No, capacity, Ser No, Location etc and reinstallation/Connecting electric connection with replacement of proper size Aluminium lugs and testing on full load at site. Note:- Spare parts shall be measured and paid separatly.
Supply only synchronous motor single phase 230 Volt suitable for servo voltage stabilizer having capacity 20 to 100 KVA.
Supply only PCB suitable for servo voltage stabilizer having capacity 20 to 100 KVA.
Supply only dimmer motor suitable for servo voltage stabilizer capacity 20 to 100 KVA
Supply only toggle On/Off switches for stabilizer capacity 20 to 100 KVA.
Supply only Volt meter 0-500 Amp 96mm squre type 3 phase 230 volt 50 Hz.
Supply only Ampere meter 0-400 Amp, 96mm square type 3 phase 230 volt 50 Hz with CT of suitable ratio.
Supply only gun metal Gate or Glove valve 20 mm for drain out of oil.
Supply only transformer oil of approved quality as per IS having dielectric strength more than 60 KV in 2.50mm gap for filling in voltage stabilizer or for topping up as required, complete all as specified and directed by Engr-in-charge.
S&F in repairs two side retro reflective sign board of inner size 3 feet x 2 feet with outer frame including stainless steel tubing 40mm bore and length 6 feet for proper support of sign board including foundation with PCC type C-2 1:3:6 (20mm graded aggregate) of size 0.2mx0.2mx0.2m at both side of stainless steel pillars. Sign board printed with green colour Retro radium based colour and laminated English Alphabets with deptt logo on both side as per existing sample at user site and taking out old unsv board, complete all as specified and directed by Engr-In-Charge.
S&F MCCB 4 pole with fixed thermal and fixed magnetic release, 100 Amps having rupturing capacity 25 KA, including taking out old MCCB, complete all as specified and directed.
S&F MCCB 4 pole with fixed thermal and fixed magnetic release, 63 Amps having rupturing capacity 25 KA, including taking out old MCCB, complete all as specified and directed.
Replacement of Earthing complete with Galvanised steel earth plate electrode 60cmx60cmx6.30mm thick buried directly in ground to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.50 mtr below ground level, earth plate surrounded by 15 cm thick packed layer of charcoal and common salt alternatively upto 90 cm and connected with and including GI strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of GI. 40 mm bore GI pipe light grade from earth plate up to testing point for protection of strip and 20 mm bore GI pipe medium grade with wire mesh and funnel for watering including necessary excavation and earth work PCC chamber (1:3:6) type C-2 with RCC cover complete all as shown in electrical plate No 3 of MES schedule Part I of SSR Part I (2009) complete all as specified. NOTE:- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B, 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lieu of CI cover and the rate includes in the unit rate of item. (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate includes in the unit rate of item. (iii) Earth pit chamber and RCC cover shall be painted with red paint over a primer coat and the rate includes in the unit rate of item.
Repair and replacement of Aluminium strip 25 x 3.15mm fixed on roof, pillars, wall etc, including porcelain isolater having not less than 50mm height with screws & saddles and placed at an interval not less than 50cm in such a manner that strip shoulde not touch the wall /roof/pillar surface etc,. for roof conductors and down conductors above ground above roof/wall/pole, complete all as specified and directed.
Supply and fixed in repair of single pointed air termination copper rod 12mm dia, 300mm long having one end flat with one 10mm dia hole fixing on roof top including fixing/fitting of termination rod at one end of GI pipe 25mm dia stand post with the help of nuts, bolts etc and making connection with roof/down conductors and making fixing arrangement of air termination rod over the GI pipe along with aluminium strip etc, complete all as specified and directed.
Supply and fix in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw, complete all as specified and directed.
GI strip 25x4mm with saddle and fixing screw etc. for down conductors from terminal block to earthing pit above ground including taking out old, complete all as specified and as directed.
Mild steel galvanised light grade 50mm dia tubing with all fitting on pole including taking out old pipe, complete all as specified.
M&L for checking earthing result using earth testing machine for lightening conductors and submitting the results to MES power house duly signed by user, complete all as specified & directed by Engr-In-Charge.
Supply, installation, Commissiong and Testing of totally enclosed LT panel box outddor type, CPRI type tested, LT 440 Volts, 50 Hz, 3 Phase 4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate following accessories with front and rear opening doors, handle type locking arrangement powder coated internally and externally shall have angle iron legs of appropriate size and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 , using 40 mm graded crushed stone aggregate as recommended by manufacturer or directed including earth work complete comprising of following : Incoming: (a) 400 Amp rated Bus bar chamber comprising 4 Nos Aluminium strip bus bars PVC insulated made of aluminium strip of size (50 x 6) mm. PVC sheathed with colour coding. (b) MCCB having current rating 320 Amp with rupturing cap 35 KA , AC 415 Volts four pole complete with spreader links. (Qty -01 Nos). (c) Multifunctional digital panel meter with LCD display flush mounting type of size 96X96 mm, accuracy class 1, suitable for CTs with secondary current 5A having provision of display parameters such as voltage, Amp, Frequency, Power factor, KW, KV etc. (Qty - 01 No). (d) Current transformer of ratio 400 / 5amps, current rating primary up to 400 amps and secondary 5 amps, accuracy class 1, VA burden 10 VA including necessary wiring using PVC insulated copper conductor cable of appropriate size as per standard engineering practice.(Qty - 1 No Set of three). (e) LED Phase Indicator Lamp (Qty - 01 Set of Three). Outgoing : (a) MCCB having current rating 160 Amp with rupturing cap 25 KA , AC 415 Volts three pole complete with spreader links. (Qty -01 Nos). (b) MCCB having current rating 100 Amp with rupturing cap 25 KA , AC 415 Volts three pole complete with spreader links. (Qty -02 Nos). (c) MCCB having current rating 63 Amp with rupturing cap 25 KA , AC 415 Volts three pole complete with spreader links. (Qty -02 Nos)
Supply & filling electrolytic distilled water for maintaining battery of DG Sets, complete all as specified and directed.
Supply only rubber hand gloves (ISI Marked) suitable for working with 11 KV HT lines, complete all as specified and directed.
Supply only Megger BM5500 5 KV Insulation Resistance Tester, Range:100 KOHM to 1TOHM, 1.4mA with digital and analogue display, Five test ranges; 250 V, 500V, 1000V, 2500V and 5000V, Guard terminal to shunt surface leakage currents, CATIII 600 V Safety rating, Power Supply 12V DC 1.25 A min, 220-240 V, 50Hz mains Power, Dimensions 220 mm x 115 mm x163 mm , IP40, Battery life : 5 hours @ 5 KV into 100 MOHM with AA Alkaline LR6 complete all as specified and directed. Make: Megger Part number: 1011-656
Supply only Amprobe TIC PRO 300 High voltage detector Ranges: For High voltage (1500 V to 122 Kv AC) & For Low Voltage (30 to 1500 V AC), verifies presence of voltage from 30 VAC to 122000 VAC without contacting the conductor with alert warns that voltage is present with bright flashing lights and loud beeps , Push button self-test verifies that tester is working properly, Ergonomic design includes a convenient handle and a universal adaptor for use with TIC 410A Hot Stick attachment to extend reach, Drop-proof to 6 feet (1.8 metre), Power source: 9V Battery, Battery type : AA, IP Rating : IP67, visual and audible voltage indication.
M&L for stone aggregate of size 20mm spreading over sand layer in the sub stations areas including proper levelling, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.50 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, complete all as specified and directed.
M & L for PCC 1:3:6, type C-2 with using 40 mm graded stone aggregate as in foundation and mass concrete, complete all as specified and directed.
Rolled sections as in Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240s, steel work, complete all as specified and directed.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade FE 410-W (Gde E-250) quality A, steel work, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, including taking down old roof sheets, complete all as specified and directed.
Mild Steel framed work as Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete, conforming to Fe 290 Gde E-165, complete all as specified and directed.
Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker MCB TPN of capacity 63 Amps, complete all as specified & directed.
S & F of Glow Sign Board PVC Acrylic sheet Housed in angle iron frame box type cover with GI Sheet with 02 Nos LED light fitting complete with accessories of size length 16 Feet X 1 Feet width outer frame made of angle iron of stand and proper support of sign board including foundation with PCC type C2 1:3:6 (20mm graded aggregate) of size 0.2 m X0.2m X 0.3m at both side of MS Angle pillars. Sign board printed with blue and white combination colour including dept logo on both size as per existing sample at user site including taking out old unsv vinyl board, complete all as specified and directed by Engr-In-Charge.
S & F of Glow Sign Board PVC Acrylic sheet Housed in angle iron frame box type cover with GI Sheet with 01 Nos LED light fitting complete with accessories of size length 4 Feet X 4 Feet width outer frame made of angle iron of stand and proper support for wall at main power house Sign board printed with blue and white combination colour including dept logo on both size as per existing sample at user site including taking out old unsv board, complete all as specified and directed by Engr-In-Charge.
S & F of Glow Sign Board PVC Acrylic sheet Housed in angle iron frame box type cover with GI Sheet with 02 Nos LED light fitting complete with accessories of size length 22 Feet X 1 Feet width outer frame made of angle iron of stand and proper support of sign board including foundation with PCC type C2 1:3:6 (20mm graded aggregate) of size 0.2 m X0.2m X 0.3m at both side of MS Angle pillars. Sign board printed with blue and white combination colour including dept logo on both size as per existing sample at user site including taking out old unsv vinyl board, complete all as specified and directed by Engr-In-Charge.
Taking down old U/S Street Light fittings of any make or any capacity from the pole of 9 Mtr after disconnecting the electric connection carefully, complete all as specified and directed by Engr-In-Charge.
S&F High performance IP66, 45W LED Street Light fixture with housing made of die cast aluminum with street optic lens and glass diffuser for uniform light distribution and inbuilt Surge Protection Device (SPD) suitable for bracket of dia Ø 35/40 mm on existing poles, complete all as specified and directed. Make: Havells Cat Part No : ENDURASUNDOWNSL45WLED765PASYBOTG or Bajaj Cat Part No - ENXT P 54L WH PO PC SD MT or Orient Cat Part No : LSFT-045-C
Material and labour for servicing /testing and calibration of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 630/800 Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required. (xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish. (xv) Replacement of Dashpot/shock absorbers . (xvi) Replacement of carbon brush of spring charging motor (b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay. Note:- Job should be carried out by specialised contractor with expert team of CG/Alstom/Areva/Schneider make Breaker.
HRC fuse of rating 2 to 6 Amp any type to suit existing system, complete all as specified and directed.
Supply and fix including Taking down Epoxy/ resin cast CT of dual core dual ratio 100-50/5+5A with 5 P 10 for protection and class-I accuracy having 15 VA burden, complete all as specified and directed.
Supply and fixing in replacement of Trip coil with plunger with working voltage 24 volts DC suitable for existing panel, complete all as specified and directed.
Supply and fixing in replacement of Closing coil with working voltage 24 volts DC suitable for existing panel, complete all as specified and directed.
Supply and fixing in replacement of Charging Spring motar of VCB trolley, complete all as specified and directed.
Taking down old UNSV insulator and Supply and fixing in replacement Epoxy resin cast insulator suitable for 11 KV VCB of Complete in all respect all as specified and directed.
Supply only insulation Tape for HT for (electro maintenance and protection), each peice 5 mtr long, complete all as specified and as directed in Engr-in Charge.
M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 11/0.433 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration, complete all as specified and directed by Engr-In-Charge. Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule here-in-after as supply only.
M&L labour for alternative arrangement by hiring, transportation of transformer of capacity upto 400 KVA in place of unserviceable copper /aluminium wound from transformer of capacity upto 400 KVA, opening top cover and carrying out the following work complete all as specified and directed by Engr-In-Charge:- (a) Dismantling of all attachment viz breather assembly, conservator, oil temperature gauge, HT/LT bushing minor repairs etc. as required and directed and keeping aside for reuse. (b) Taking out the core with winding assembly. (c) Removing of complete winding from core and dismantling the core, cleaning of core laminate sheet and keeping aside for reuse (d) Cleaning of complete transformer tank oil fins, removing of sludge, and making the inside surface of tank dry by blowing of hot air as directed and specified. (e) Painting of outside surfaces of transformer complete by means of spray machine as directed. (f) Rewinding of HT/LT leg coil complete using copper wire /strip of appropriate gauge, size and turn as per existing with double paper coated insulation including all requisite insulating materials like packing sleeves, separator, tapes etc. heating, varnishing the core and winding assembly after framing up top and bottom steel structure of transformer all as specified and directed. (g) Replacement of all insulating materials other than incorporated for rewinding of HT/LT coils as per existing. (h) Fixing only HT procelain bushing with studs, nuts, washers 3 Nos. and LT procelain bushing with studs, nuts, and washers 4 Nos. and connection with primary and secondary windings and reconnecting with the main terminals as required and directed. (j) Replacement of all unserviceable gasket from top cover, HT/LT bushing with new one by using rubberised gasket sheet 4.0mm/6.0mm thick duly pasted with suitable adhesive . (k) Replacement of unserviceable bolts with new one and fixing of existing serviceable bolts, nuts, washers of different sizes and tightening properly. Note :- The contractor shall give written warranty of one year from the certified date of completion for the repaired transformer. HT/LT leg coils and transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule here-in-after as supply only.
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in transformer or for topping up as required and directed by Engr-In-Charge.
Supplying and fixing in replacement (at site/workshop), Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 400 KVA and re-connecting electrically and mechanically, testing, complete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transformer oil, opening of top cover by unscrewing nuts, bolts, washers and suitable size pad type bus bar almuminium and nut bolt washers etc.
Supplying and fixing in replacement (at site/workshop), Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 400 KVA and connecting electrically and mechanically, testing, complete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transformer oil, opening of top cover by unscrewing nuts, bolts washers and suitable size pad type bus bar almuminium and nut bolt washers and reconnection.
Supplying and fixing in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers, capacity upto 400 KVA, complete all as specified and directed.
M&L or rewiding of HT/LT coils of transformer of capacity 25 KVA to 400 KVA with super enamelled copper winding wire of appropriate gauge and proper number of turns alongwith insulating material eg leatheroid, paper insulation, cotton tapes, Empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish, heating/drying etc, complete all as specified and directed by Engr-in-Charge.
M&L or rewiding of HT/LT coils of transformer of capacity 25 KVA to 400 KVA with super enamelled Aluminium winding wire of appropriate gauge and proper number of turns alongwith insulating material eg leatheroid, paper insulation, cotton tapes, Empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish, heating/drying etc, complete all as specified and directed by Engr-in-Charge.
Maintenance & repair of Compact substation(3Way/4way) from OEM at various location of following capacity (Note: rate quoted deemed to be inclusive of any type of T&P, testing kits, wiring of any type of existing size wire & tagging, CT's, metering and Metering Display device, manpower, including any Spare parts parts required on site and required at site for any type of maintenance). 1) IEC 62271.202, Type CSS - SN, Transformer: 11/0.433kV, upto 400 kVA The scope of work is as follow:- (A). RMU 630A (HT Side) 1. Checking and making fuctionality of RMU mechanism in auto and manual mode. 2. Checking and toping up of SF6 gas of any quantity, rate quoted deemed to be inclusive of any type of T&P required at site and producing certifate of same from OEM. 3. Checking and making functional breakers ON/OFF operation, manually & electrically. 4. Functional checking of all electrical & mechanical interlock operation of RMU. 5. Testing of CTs & Relays with testing kit and producing certificate of same from OEM. 6. Caliberation of Relays and producing certifate of same from OEM. (B). Transformer (upto 400 KVA) 1. Checking and making Transformer functional. 2. Checking and toping up of oil level in T/F. 3. Checking and making Functional of cooling fan, if available. 4. Checking function of hooter/Buzzer. 5. Routine test of Transformer and producing test certificate of same.
(C). LT Side. 1. Checking and making all the ACB & MCCBs fuctional. 2. Checking and making all the ACB/MCCBs ON/OFF operation manually & electrically. 3. Checking and adjusting and servicing all the ACB and ACB relay setting as per load conditions, Metering devices, CT's and wiring of any type and producing certificate of the same. 4. Repair/replacement to APFC panel capacitor bank of 25KVAR x 4 (max) and APFC relay setting, repairing LCD display, repairing/replacing CT's, fans, contactors of any type, fuse is deemed to be included in quoted rate. 5. Repair replacement of battery charger upto 24 Volts is deemed to be included in quoted rate. 6. Repair/replacement of flash out Bus bar & insulators of any length, rating and any quantity is deemed to be included in quoted rate. 7. Repair/replacement of unserviceable handle assembly FNX/FN type, auxillary contact kit, LED indication of any colour, push button etc. is deemed to be included in quoted rate. Note: Job should be carried out by Specialised Contractor with expert team of Schneider make RMU.
Material & Labour for repairing of cable termination 95 sqmm including additional cable braid earth, lug seal, new lug and anti traction tube, complete all as specified and directed.
M&L for servicing of ACB with Microprocessor (Make: crompton greaves), Range (800-1250Amps) 415V, 50Hz,50 KA, after taking shut down and properly replacing flash out bus bars, settings relays and their mechanism, repairing charging mechanism & handle, removing wornout parts, repacing and testing and commissioning, complete all as specified and directed by engineer-in-charge. Note:- T&P and Parts required to make the ACB are deemed to be included in quoted rates.
S&F of Space Heater of rating 80W/200W with Thermostat (25 degree to 65 degree) in Bus Chamber, Cable chamber & Breaker Chamber with Copper Wiring for connection from Control chamber to given location incliding all accessories i.e lugs, Cable tie, screws, nuts etc, complete all as specified and directed by engineer-in-charge.
M/S MALHI CONSTRUCTIONS (BID ID -3101209)
Eshaan Construction Co. (BID ID -3117184)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .