| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.0 L+₹1.1 L (6.80%)Rejected-AOC | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹17.8 L+₹1.9 L (12.1%)Rejected-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹18.9 L+₹3.0 L (18.7%)Rejected-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L4 | Rejected-AOC Become L4 | |
| 5 | L5₹19.5 L+₹3.6 L (22.8%)Rejected-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L5 | Rejected-AOC Become L5 |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
10 Oct 2019, 6:00 pmClosed
GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARAILI
Repair replacement of security lights conversions of HPSV lamp and florescent lights LED lights and repair to transformers VCBs and connected items at Misa Camp under GE South Tezpur
2019_MES_281454_1
8442
Open Tender
Civil Works - Others
Item Rate
180 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹42,000
Yes
27 Jan 2020
12 Sept 2019
12 Oct 2019
12 Sept 2019
10 Oct 2019
27 Sept 2019
Amount
Dismantling and taking down light fitting single / double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories complete all as specified and directed.
Supply and fixing LED street lights not less than 30W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP65 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions. Make :- Eveready Cat No. LEDSL030I57-02 or equivalent of Philips / Havells India Ltd./ Surya Roshni Ltd. / Bajaj / Wipro / GE/ M/s Simoco Telecommunications(South Asia) Ltd
Supply and fixing LED street lights not less than 60W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP66 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions. Make :- Eveready Cat No. LEDSL060I5-02 or equivalent of Philips / Havells India Ltd./ Surya Roshni Ltd. / Bajaj / Wipro / GE/ M/s Simoco Telecommunications (South Asia) Ltd
Supply and fixing LED street lights not less than 45W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP65 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions. Make :- Eveready Cat No. LEDSL04515-02 or equivalent of Philips / Havells India Ltd./ Surya Roshni Ltd. / Bajaj / Wipro / GE/ M/s Simoco Telecommunications(South Asia) Ltd
Supply and fixing LED street lights not less than 70W with a single piece of pressure die cast aluminium housing and secondary optics and individual LEDs for a better light distribution and control with IP65 degree of protection and integrated driver with 10KV surge protection complete as per manufacturer's instructions. Make :- Eveready Cat No. LEDSL07215-02 or equivalent of Philips / Havells India Ltd./ Surya Roshni Ltd. / Bajaj / Wipro / GE/ M/s Simoco Telecommunications(South Asia) Ltd
S & F powered by inbuilt, isolated electronic LED driver (SMPS based constant current supply) with lower THD, output open, short circuit protection, phase to phase protection, over voltage protection, surge voltage protection including taking down old unserviceable LED driver complete all as specified and as directed.
M & L for making swan neck end size of not exc. 32mm GI pipe for mounting street light at top of existing LT pole including cutting, welding, reaming, finishing ,bending in appropriate size at existing location as directed .
M & L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as speccified and directed by GE.
S & F multicore round 2core cable of size 1.5sqmm PVC insulated and FR PVC round shethed,copper conductor (flexible) 1100volts , conforming to IS 694 for connecting security light from junction box and nacked overhead conductor to security light end terminal as directed.
Supply and fixing LED not less than 9W LED bollard for pathways and gardens are made with aluminium extrusion for sturdiness and better finish, UV stabilized injuction moulded oval polycarbonate diffuser for spot-free lighting and IP 65 degree of protection with fixing accessories complete as per manufacturer's instructions. Make :- Eveready Cat No. LEDBOLLARDA009I3-IR or equivalent of Philips / Havells India Ltd./ Surya Roshni Ltd. / Bajaj / Wipro / GE/ M/s Simoco Telecommunications(South Asia) Ltd
Supply connecting , glanding ,laid in ground/ fixing on surface of wall/ drawn through in GI Pipe etc connecting ,thembling and testing of LT under ground aluminiun conductor, XLPE insulated, PVC sheathed, electric power heavy duty 1100 volt grade earthed galvanised steel wire/ strip armoured 4 core 16 Sqmm cable complete all as specified and directed.
Supply connecting , glanding ,laid in ground/ fixing on surface of wall/ drawn through in GI Pipe etc connecting ,thembling and testing of LT under ground aluminiun conductor, XLPE insulated, PVC sheathed, electric power heavy duty 1100 volt grade earthed galvanised steel wire/ strip armoured 2 core 6 Sqmm cable complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
M&L for sand cushioning with clean dry sand for protection of under ground cable complete all as specified and as directed. Note :- Punned thickness of sand layer shall be measured and paid to contractor.
M&L for Brick Sub Class 'B' locally available best quality laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection complete all as specified and as directed.
S & F thermoplastic cable junction boxes IP65 ''weather proof'' for outdoor installation with knockout for cable entry-Black colour with terminal for cable suitable size with glands protection ,dimension of box not less than 210x310x116 mm including connectors clamp made out of MS with nuts & bolts with washer for fixing in poles for connecting conductor of street light including MCB SP 6-32 Amps 1no, 100A rating bus bar 4 nos mounted on insulators and all cable fixed with suitable lugs and suitable cable gland complete all specified and as directed. (Make:-Hensel cat part no K8500 or equivalent make of Sintex Industries Ltd./Any other approved make of HQ E-in-C's Br or HQ CE Eastern Command) Note:-(a) Materials for fixing like MS clamps, nuts, bolts & washers are measured & paid separately under relevant item of schedule. (b) Labour for fixing of MS clamp, nuts & bolts shall deemed to be included in unit rates. (c) Unit rate shall include connecton between existing incoming LT cable lines to new junction box.
S & F thermoplastic cable junction boxes IP65 ''weather proof'' for outdoor installation with knockout for cable entry-Black colour with terminal for cable suitable size with glands protection ,dimension of box not less than 139x119x70 mm including connectors clamp made out of MS with nuts & bolts with washer for fixing in poles for connecting conductor of street light including MCB SP 6-32 Amps 1no, mounted on insulators and all cable fixed with suitable lugs and suitable cable gland including necessary PCC foundation for landscape light complete all specified and as directed. (Make:-Hensel cat part no K8060 or equivalent make of Sintex Industries Ltd./Any other approved make of HQ E-in-C's Br or HQ CE Eastern Command) Note:- (a) Materials for fixing like MS clamps, nuts, bolts & washers are measured & paid separately under relevant item of schedule. (b) Labour for fixing of MS clamp, nuts & bolts shall deemed to be included in unit rates. (c) Unit rate shall include connecton between existing incoming LT cable lines to new junction box and cost of necessary PCC foundation for landscape light.
Supply and fixing MCCB ,4 pole, TPN, 415 volts ,microprocessor based , rated 63 Amps,having repturing capacity 16 KA - 01 No as incomer complete. Note :- All MCCBs of sch shall be conforming Ics= 100% Icu as per IEC 60947 -2 and front LED indication (ready, overload pre-alarm & over load).
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long, single swan neck type inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint incl preparation of surfaces complete all as specified and directed. The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. NOTE : Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work.
M&L for cement contrete 1:4:8 type D- 2 40 mm graded stone aggregate as in foundation of pole filling and mass concrete in complete all as specified and as directed.
M&L for cement contrete 1:3:6 type C- 1 20 mm graded stone aggregate as in mud stops, rounded or chamfered on edges etc complete all as specified and as directed.
M&L for cement contrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof, kerb or mud stops rounded or charfered on edgees ,coping etc complete all as specified and as directed.
Supply and fixing GI pipe of dia 40mm to wall / pole / laid in trenches of medium grade with required clamping arrangements to fix with the pole complete and connecting to existing pipe line all as specified and as directed.
Supply, Installation, testing and commisioning of CPRI approved LT panel of size not less than 0.5m x 0.5m x 0.4m Indoor type totally enclosed dust and vermin proof, free standing, factory fabricated, fully compartmentalized in design suitable for 415 volts, 3 phase, 50 Hz, 4 wire AC system conforming to IS : 375 all as specified herein after. Degree of protection shall not be less than 1P-51 as per IS : 2147 and it shall be suitable to withstand a Fault level of 50 KA (rms) for one second. Busbars shall be of copper not less than 100 Amps rated capacity . Cross section of Busbars for each phase and neutral shall be same. All the Busbars shall be air insulated and will be codified in Red, Yellow, Blue and Black colours as per the standard practices using heat shrinkable sleeves. Copper busbars shall be made of high conductivity 99.9% pure copper of ETP grade. All the busbars shall have full round edges and shall be suitably braced with non-hygroscopic SMC supports of 660 volts grade. Copper Bus bar should be provided for MCCBs. Note:- MCCB will be measured and paid under relevant item of schedule.
Taking down the HT vacuum circuit breaker of any make, capacity from 400-630 Amps, 11 KV, 800Amps for servicing, repairs and re-assembling complete comprising of the following including testing and commissioning all as directed. (a) Dismantling the VCB from the enclosure consisting of vacuum interrupter assembly, socket contacts, checking the serviceability of all parts, cleaning, alignment of closing/opening mechanisms and re-assembling the unit complete. (b) Cleaning the external surface of bushings with CRC/ Tri-chloro-ethylene to remove the accumulation of carbon or any other deposits. (c) Checking the vacuum interrupter assembly and contacts and ensure the alignment of contacts. (d) Dismantling the spring charging mechanism of the VCB, checking the operations of the closing/tripping through closing/tripping coils electrically as well as manual charging including cleaning re-adjusting worn out parts etc. (e) Checking the condition of the spring charging motor along with gear box including servicing to the motor commutator bushes, lubrication of bearing surfaces etc. (f) Checking the ratchet wheel assembly, driving and charging parts and adjust. (g) Inspecting all bolts, nuts, pins and ensure collar pins are in place and they are tight and opened properly. h) Applying petrolium jelly to moving contact arms and Doctor beck solution to insulated parts moving arms of breaker and reassembling the unit
Decarbonising/ cleaning and painting complete 11 KV HT panels board, cubicle type, consists of bus bar chamber, circuit chamber and metering chambers by opening the spout/bus covers, inspecting the bus bar joints, cleaning of bus bars, checking the bus bar spouts and circuit spouts for any flashovers/ cracks, applying Anti - Track Busbar Insulation Tape to the bus bars and applying Anti tracking Paint Red solution for insulating to spouts having moderate tracking, applying HT insulated red compound/ Monoplast compound at the bus bar joints after tightening of joints, cleaning of bus bar insulators and bus bars with CRC ,painting Panel (both inside and outside) with one coat with synthetic enamel paint and ensure proper decarbonisation and re-assembling complete all as directed. NOTE :- (i) Cost of additional hardware like bolts, nuts, washers and spring washers, petroleum jelly etc, to put the breaker in serviceable condition is deemed to be included in the item rate quoted for the repairs. (ii) Old unserviceable spare parts removed from the breakers shall be accounted for under schedule of credit .
Supply only strip space heaters with thermostat switch of rating 230V, 80W with necessary wiring with 1.5sq.mm copper conductor wire, electrical connections with suitable lugs and proper dressing complete including replacement of necessary bolts and nuts washers etc. all as directed.
Taking out Unserviceable HRC/HBC Fuse and Supply and Fix new HRC /HBC fuse 2-32 Amps Cylindrical fuse link all as specified and directed.
Supply,Laying ,testing, and commissioning size 3x95 sqmm cross-sectional area XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric cable with aluminium conductor 11000 volts grade, in tranches / fixing on wall by saddel/ fixing on poll / drawn through GI pipes all as specified and directed.
Material and labour for filtration of transformer oil of Transformer 500 KVA with ultra high vacuum filteration machine and checking dielectric strength (BDV), dielectric dissipation factor, neutralizing value (total activity), upto 60 KV with 2.5 mm Gap sludge content, flush point of transformer oil from Standard Testing Laboratory all as specified. Refilling the transformer oil in the shell of transformer after carrying out filteration and heating up oil to achive required dielectric strength and submitting the test result after filteration of oil in proper proforma duly signed.
Supply and fill Transformer oil with high viscosity, high resistance to oxidation & thermal stability all as specified and directed. MAKE-CASTROL/INDIAN OIL/HPCL
Material and labour for painting to 500 KVA transformer scrapping and removing oil paint and applying one coats of synthetic enamel paint by taking due care for HT/LT side supply all as specified and directed.
Supply & Fix syntheic mat of size not less than 2m x 1m x 19 mm including taking out old Unseveciable Syntheic mat all as specified and directed.
Suppy and fix in repair of breather with silica gel crystal (1 kg) type all as directed.
Supply and fixing in replacement to old by new Danger notice plate of 1.6 mm thick mild stell sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts and nuts of approved size for LT 25x15 cm size all as specified and directed. Note :- Instruction shall be written in three lauguage Hindi, English and Assami on notice board.
Supply and fixing end termination jointing kit ,11000 volt grade (earthed) ,suitable to 3 core 95 sqmm aluminium conductor XLPE armoured heavy duty cable, cold shinkable suitable indoor type with jointing material and accessories.
Supply and fixing straight through jointing kit ,11000 volt grade (earthed) ,suitable to 3 core 95 sqmm aluminium conductor XLPE armoured heavy duty cable, cold shinkable suitable indoor type with jointing material and accessories.
M & L for complete over hauling of transformer ( Indoor type 500 KVA, 11/0.4KV) comprising of the following scope of works :- (a) Disconnecting carefully all electrical connection from HT/LT side of transformer after proper shut down. (b) Checking the leakage of transformer oil from tank joints, bushings, inlet/out let valves ,breather etc ,servicing,openning the transformer and disconnect the star and delta connection for HT and LT windings ,testing the insulation resistance.
S & F epoxy Bushings for LT, 440 Volt side of the transformer for connecting outgoing cable with all the accessories including taking down old unserviceable bushings complete all as specified.
S & F rotary operating handle for tripping and closing VCB , 11Kv including taking down complete all as specified and directed.
S & F epoxy Bushings for HT ,11000 Volt side of the transformer for incoming cable with all the accessories including taking down old unserviceable bushings complete all as specified.
M&L for earthing complete with GI earth plate electrode 600x 600 x 6 mm burried directly in ground vertical to a depth not less than 2.25 mtrs below ground level with the top edge of earth plat at a depth not less than 1.5 mtrs below normal ground level connected to GI earth strip in size 32x6 mm by means of nut bolts and washers etc. connected to sub LT Panel including necessary excavation earth work ,PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth chamber 40 mm thick RCC cover with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate 40 mm dia GI pipe medium grade for watering, funnel, protection pipe ,adequate quantity of commen salt, charcoal etc. and connecting upto main sub panel complete all as specited and shown in electrical plate No. 3 of MES Sch Part -1 complete all as directed by GE.
M.S. Construction
MAHANTA ENTERPRISES
Flint India
D G Corporation
KAMAKHYA CONSTRUCTION AND BUILDERS
SONI ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .