Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹41.3 L
EMD Value
₹82,520
Closing Date
16 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
SPL REPAIR TO STPs OF CENTRAL and NORTH ZONE AND PROVN OF SHED FOR PARKING OF 50 CAPACITY OF TWO WHEELER/ BICYCLE AND 02 X CAR FOR PATIENTS/ TROOPS AT KIRPAN DIV MI ROOM UNDER GE (NORTH) BINNAGURI
2025_MES_717489_4
8701/08/2025-26/09/E8
Open Tender
Civil Works
Item Rate
180 days
Binnaguri cantonment
D class Category a(i)
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹82,520
Yes
15 Nov 2025
15 Nov 2025
18 Dec 2025
15 Nov 2025
16 Dec 2025
24 Nov 2025
Demolition of RCC as in slab beam lintels, shelves chajjas reinforcement cut as required to facilitate demolition complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plu
M&L for sliding door bolt of 300mm long plate Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F mild steel work such as window guard bars and similar work conforming to Fe – 290 Grade – E 165 complete all as specified and as directed.
Taking down cement plaster on wall / Ceiling of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for brick work with fly ash bricks straight or curved on plain exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for preparation of old plastered surface and Applying two coats of oil bound distemper over a coat wall care putty over plastered surfaces including priming the surface complete all as specified and directed
M&L for 25mm thick pre-polished and chemically treated smooth finish exterior grade coloured chequered tile (300X300)as in path including 15 mm thick Screed bed in CM 1:6 all as complete and as specified and directed.
M&L for kota stone slab polished 18 to 20mm thick in riser or steps, skirting, dado and pillar laid over 10 mm thick screed bed cement screed (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Fixing only chain link fencing including lines wires any mesh size and type of any standard rails straining bolts etc including provision of binding wire complete all as specified and as directed.
S&F 75 mm bore PVC(SWR) pipe socketed in any length with rubber ring joints,laid in trenches or in floors complete all as specified and as directed.
Per Sqm
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soft/loose soil complete all as specified and as directed.
All as per item No 96 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No 96 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No 96 here in before but for one light point controlled by one, two way switch 5 Amps
All as per item No 96 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S&F of switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F switch piano flush type 5 amps single pole two way complete all as specified and as directed
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
S&F of switch piano flush type 15/16 amps single pole one way complete all as specified and as directed.
S&F of Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish complete all as specified and as directed.
S&F switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type complete all as specified and as directed.
S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F LED white glass Lamp 1x9/10 Watt 230V Base-22 complete all as specified and directed.
S & F deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 120 mm including taking down existing unserviceable. complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable. complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 200 mm x 100 mm including taking down existing unserviceable. complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable. complete all as specified and as directed.
S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
M&L for Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 Security light fitting luminaire with high power LEDs as light source and driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor cable from ceiling rose to fitting and GI Pipe bracket made out of GI pipe medium grade 1.2 Mtr long 32 mm dia , MS clamp, nut, bolt and washers including taking down the old unserviceable fitting complete all as specified and as directed.
M&L for sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 4.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic conduit complete all as specified and as directed. (NOTE : Two run of submain wiring cable alongwith one run of earth wire with and including 25mm dia PVC conduit pipe shall be measured as one unit length).
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 25 to 100 Amps of breaking capacity 16 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one all as specified and directed including taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
S&F in repair MCB, Single pole & neutral, 32 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI strip 25x4 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade f
or protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4.0 mm dia mm as earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations of poles etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and leveling complete as specified and directed .
Supply and laying sub class B bricks of size 230x125x73mm(+/- 10% tolerance limit) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
Laying only old burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and as directed.
Horizontal boring suitable for 50mm bore steel tubing, under road/ pavement / hard standing etc.,not exceeding 10 Metres in length, in any type of soil, suitable for passing through up to 50 mm bore, galvanised steel tubing,complete all as specified and as directed.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed.
Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material and keep serviceable material for reuse in safe custody of any size complete as directed (Note:- Excavation/earth work shall be measured & paid separately under relevant item of this schedule)
Supply, laying ,jointing and testing LT underground electric power cable crossed linked XLPE insulated, two or more core galavanised steel strip or wire armoured / PVC insulated armoured cable heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipes etc fixing and connecting accessories such as Aluminium cable lugs, cable glands , nut , bolts , washers etc complete all as specified and as directed. Note: (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items)
Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A').
Material and labour for LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 6000 lumen, system wattage 60 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed.
Material and labour for disconnection of all electric connection and taking down of street light fittings of any type , size , capacity and model removing of unserviceable spares or accessories for repair/ replacement of the same including reconnecting and refixing of street light to its existing position viz pole / high mast and testing complete all as directed.
Material and labour for LED flood light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminum frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 20000 lumen, system wattage 200 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed.
Material and labour for Digging out incoming and outgoing cables of any sizes from loop near junction box/ feeder pillar box in tranches, cutting burnout uninsulated portion of cable and rectify the defect and relaying the XLPE cable under ground aluminum conductor in trenches and returning and filling the excavated soil and connecting the cables with bus bars including provision of lugs as applicable and testing complete all as specified.
Supply and fixing loop in- loop out fuse junction box of internal dimension 250 x 200 x 100mm made of FRP sheet with weather proof canopy and locking screw fitted with and including 50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing , mounted in the box, fixing on street pole/rail poles including necessary aluminum clamps, suitable glands, lugs and GI nut and bolt and 01 SP of 6 Amp for controlling including taking down old unserviceable junction box all as specified and as directed Note : Contractor shall provide cable lugs and PVC gland of suitable size if required on site for connecting cable in junction box.
Supplying and fixing in repair single run 3 core , 2.50 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy duty cable PVC insulated and PVC sheathed from pole junction box to light fitting complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate for coping / pedestal of poles including necessary form work, fair finishing to exposed surfaces by using extra cement complete all as specified and as directed.
M & L Painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line/ for street light with two coat of aluminum paint after scratching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writing with black synthetic paint/ Sticker, including painting strips in alternate from bottom to top with three strips of black synthetic paint & two strips of Yellow/ Sky blue paint (as per existing pattern through out
the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on PCC copping of pole and re-numbering of pole with approved size of letter ( Example - P- 001) with synthetic enamel paint of white colour background and black colour lettering complete all as specified and as directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender.pdf
Tender Documents • 1.68 MB
BOQ_828652.xls
BOQ • 0.47 MB
Sch.pdf
Additional Documents • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .