Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAdmitted-Finance 140 1 110 N S C BOSE ROAD REGENT PARK KOLKATA WEST BENGAL 700040 | KOLKATA | KOLKATA | WEST BENGAL | 700040 | ₹10.0 L | L1 | Admitted-Finance |
| 2 | L2₹10.0 LAdmitted-Finance 01 OPPOSITE D C OFFICE LAL CHOWK ANANTNAG LAL CHOWK ANANTHNAG JAMMU KASHMIR 192101 UDYAM JK 01 0002801 | ANANTNAG | JAMMU AND KASHMIR | 192101 | ₹10.0 L | L2 | Admitted-Finance |
| 3 | L3₹10.1 LAdmitted-Finance | ₹10.1 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CALTECH L3 | S S ENTERPRISE L1 | BLUE STAR AND CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | TOTAL | 1 | Nos | 8,47,009 ₹10.1 L | 8,36,196.5 ₹10.0 L | 8,41,981.5 ₹10.0 L |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
14 Mar 2026, 5:00 pmClosed
Ex. Engineer(E), Lighting/Crematorium Deptt.
Office of the DG (E) LIGHTING DEPARTMENT Kolkata Municipal Corporation 5, SN Banerjee Road Kolkata-700 013 West Bengal
Restoration and Upgradation of Brick-Built Chimney and Duct line including Motor Servicing and Allied Works for the Air Pollution Control System Connected with Furnace No. 1 and 2 of the Old Complex at Sirity Burning Ghat
2026_KMC_1018044_1
KMC/LTG/CRM/14/SBG/2025-26
Open Tender
Miscellaneous Services
15 days
Sirity Burning Ghat
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹20,000
25 May 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
14 Mar 2026
6 Mar 2026
TOTAL
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Supply and Fixing of 450 mm dia S.S.-304 Damper of 2mm thick plate with both end flanges
DESIGN, SUPPLY AND DELIVERY AT SITE, INSTALLATION OF 90 DEGREE BEND WITH 400 MM DIA MADE OF 3MM THICK SS 304 SHEET AD LABOUR CHARGES IN ALL COMPLETE AS PER TECHNICAL SPECIFICATION LAND DIRECTION OF E.I.C.
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. (RATE IN RS. PER MTR) 6 SQ MM 2 CORE BEARING HOUSING AND COMPLETE THE NECESSARY REPAIRING WORKS AS PER DIRECTION OF E.I.C. UPTO 75KW LT SQ. CAGE IM
DESIGH, SUPPLY AND DELIVERY AT SITE, INSTALLATION OF CIRCULAR DUCT OF 400 MM DIA AND ONE METER LONG MADE OF 3MM THICK SS304 SHEET AND LABOUR CHARGES IN ALL COMPLETE AS PER TECHNICAL SPECIFICATION AND DIRECTION OF E.I.C
DESIGN, SUPPLY AND DELIVERY AT SITE, INSTALLATION OF SQUAR TO ROUND OF 5 MM THICK SS 304 SHEET AD LABOUR CHARGES IN ALL COMPLETE AS PER TECHNICAL SPECIFICATION LAND DIRECTION OF E.I.C
DESIGN, SUPPLY AND DELIVERY AT SITE, INSTALLATION OF CONE(CROWL) OF 5 MM THICK SS 304 SHEET AD LABOUR CHARGES IN ALL COMPLETE AS PER TECHNICAL SPECIFICATION LAND DIRECTION OF E.I.C
BUILDING WORKS (B) DISMANTLING, CUTTING CHASE, HOLES ETC. 1. Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. (a) In ground floor including roof
BUILDING WORKS (B) DISMANTLING, CUTTING CHASE, HOLES ETC 13. Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
BUILDING WORKS ( C ) Brickworks,Concrete Works etc 9?...Controlled Cement concrete grade mix with well graded stone chips (20 mmnominal size) including adequate plasticiser & excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 360 Kg of OPC [43/53 grade ] cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] With Pakur Variety M 40 Grade of Concrete
Supply and fixing the S.S 304 plates 14 S.W.G.( 2 mm) thick 980mm x 225mm complete cutting and grinding
Supply and delivery of the following bearing (Make: SKF):6406
DOUBLE BALL BEARING FOR SN-E SHAFT OF I.D FAN (12000CU.M/HR): Supply and fixing of the Roller bearing in the shaft of blower (SKF make 22312E/C3)
PALMER BLOCK: a) Supply, fitting and fixing C.I palmer block for suitable to EN-24, 60 mm dia shaft including proper alignment and fixing in the pedestrian of the blower for free run of impeller.
Supply and fixing of Adapter Sleeve with oil groove (H313/PC) for 25 HP I.D. Fan/Blower (specially for APC devices of Wooden Pyres
Supply and fixing of Locating Ring(FRB 12/180) for 40 HP I.D. Fan/Blower (specially for APC devices of Wooden Pyres
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
form.pdf
Tender Documents • 0.73 MB
BOQ_2502105.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid