Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.5 LAccepted-Finance | ₹62.5 L | L1 | Accepted-Finance Selected |
| 2 | L2₹68.2 LAccepted-Finance GROUND FLOOR G 1154 A MANSAROVAR PARK SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | ₹68.2 L | L2 | Accepted-Finance Selected |
| 3 | L3₹68.5 LAccepted-Finance 03 SHRI RAM ARCADE SHRIRAM PARISAR KHAJURI KALAN BHOPAL MADHYA PRADESH 462022 UDYAM MP 10 0000330 | BHOPAL | MADHYA PRADESH | 462022 | ₹68.5 L | L3 | Accepted-Finance Selected |
Tender Value
₹93.3 L
EMD Value
₹1.9 L
Closing Date
7 Mar 2026, 12:00 pmClosed
Executive Engineer (E)
O/o EE(E) PWD EMD M-351, R.No.185, Old Sectt Delhi
Upgradation, Renovation, Rehabilitation works and shifting of JJB-I and III at Sewa Kutir Complex, Kingsway Camp, Delhi. (SH- Electrical Work).
2026_PWD_287972_1
132/2025-26/EMD M-351/EE(E)
Open Tender
Miscellaneous Services
180 days
Sewa Kutir
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹1.9 L
9 Mar 2026
28 Feb 2026
7 Mar 2026
28 Feb 2026
7 Mar 2026
28 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
6 x 1.5 sq. mm
Supplying and drawing following pair 0.5 sq mm FRLS PVC insulated copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing suitable size GI box with modular plae and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plug)
Supplying and fixing suitable size GI box with modular plae and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required. (suitable for fixing in 2 Module box)
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required.
1 Run of cable
2 run of cable
3 run of cable
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Supplying, Installation, Testing and Commissioning of 300 mm Sweep 900 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd.
Supplying, Installation, Testing & Commissioning of 250 mm sweep, 1200 rpm or better, fresh air fan, Max. Power Consumption <= 45 Watt and Minimim Air Delivery >= 720 CMH, fixing the same in existing opening/ventilation window i/c providing and fixing min. 6mm thick bakelite sheet in the existing opening etc., cutting in proper size making good the damages i/c earthing & connection with 1.5 Sqmm FRLS PVC copper wire etc. as required.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim .
S.I.T.C of 6-10 W LED bulkhead fitting made out of CRCA sheet duly power coated/Cast Aluminium body, confirming to IP66, suitable for operation on 240 V, 50 Hz AC Supply having power factor ≥ 0.90, complete i/c making connection, testing and commissioning etc complete as reqd. (Note:- Contractor shall submit 5 Years guarantee certificate of respective manufacturer along with the fitting).
Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 Amp, 30KA, FPMCCB
150 A, 16 KA,TPMCCB
200 A,36KA,FPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer MCCBs) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required.
For 14 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 50 sq. mm (32 mm)
3½ X 70 sq. mm (35 mm)
3½ X 150 sq. mm (50mm)
Supplying & laying one number XLPE insulated PVC sheated Al. Conductor armoured Power cable of 1.1 KV grade of following sizes Conforming to IS. 7098/1988 with upto date ammendment on existing RCC/ HUME/ STONEWARE/ Metal/ HDPE pipe/on Surface, loose with proper saddeling complete etc. as required.
3½ X 50 sq. mm
3½ X 70 sq. mm
3½ X 150 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II (Ammended on date as IS :16205 Part – 24:2018) complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
Supply, Installation, Testing Commissioning of following decorative ornamental Steel Poles made out of galvanized Mild Steel tubes i/c Single decorative ornamental bracket. The poles are primer coated and painted with polyurethane paint. The pole has a service window at the bottom comprising four way 25 Amp connector terminal and a MCB poles has a mild steel base plate having four numbers mounting holes and can be mounted with four numbers anchor bolts i/c foundation bolt & making foundation of suitable size i/c connection in mcb, testing and commissioning etc as reqd.
3 Mtr height having 114mm dia x 4mm thickness x 1000mm height at bottom and 75mm dia x 3mm thickness x 2000mm height at Top with cast aluminium emb.
S.I.T.C of following LED Post Top Lantern fitting made out of CRCA sheet, duly powder coated /Aluminium body, confirming to IP - 66, suitable for operation on 150 V to 270 V,(5500 to 6500K), 50 Hz AC Supply, having power factor ≥ 0.95, CRI > 80, Luminaries efficacy ≥ 80 lumen/watt , Driver efficiency > 85%, 10 kv surge protection, L-70 Life 50,000 burning hours. complete i/c dismentaling of existing fitting if any, connection, etc complete as reqd. (Note:- Contractor shall submit 5 Years gurantee certificate of respective manufacturer along with the fitting).
Supplying, installation, testing & Commissioning of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal, carbon Plus SS Thrust bearing, stator body of cast iron, having following HP Rating, phase, Head range, Discharge range respectively, conforming to IS : 14220: 2018 and CED coated casting, BEE 3 star or more performance rating, Motor shall be IE2 class as per IEC 60034-2-1:2007, IEC 60034-30:2008 & IS12615:2011, including making connection suitable for Sump well, lowering of the pump along with GI pipe & cable(s), installation with complete fitting and accessories, jointing of electrical cables up to starter, angle Iron frame work of 35mmx35mmx6mm with Nut Bolts complete in all respect as approved by Engineer in charge etc. as required.
5.0 HP/3.7 KW, 3-Ø, (14 -27) Mtr, (990-500) LPM
Supplying, fixing, testing and commissioning of ISI marked GM Gate valve (Double Flanged) of PN 1.6 rating Class-I flanges screwed in bonnet non rising stem complete with nuts, bolts, washers, gaskets conforming to IS:778-1984 of following sizes as required :
50mm dia
Supplying, fixing, testing and commissioning of ISI marked GM Non Return valve (Double Flanged) of PN 1.6 rating Class-I flanges screwed in bonnet non rising stem complete with nuts, bolts, washers, gaskets conforming to IS:778-1984 of following sizes as required :
50mm dia
Providing, laying, testing & commissioning of following size GI pipe 'B' Class (ISI marked) conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc.and laying in open complete as required.
50mm dia.
Supplying, Laying & fixing of following size copper conductor (conforming to IS:8130 (2013)) PVC insulated and PVC sheathed (ISI marked) Flat submersible cable confirming to (IS:694) of 1.1 kV grade, clamping the cable with pipe line of Pump in Bore/ Sump tank and up to the control panel in existing pipe / open trench / Cable tray / on surface including making connection, testing etc. as required.
3 core, 4.0 Sq.mm.
Supplying, installation, testing and commissioning of Indoor floor mounted modular, sectionalised, compartmentalized, dust & vermin proof, extendable type MV cubicle panel having enclosure protection class IP 42 of suitable size & 350 mm deep of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, i/c mounting base frame consist of MS channel of size 75x75xx5 mm, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with 4 nos. electrolytic grade high conductivity Aluminium busbar extensible type, DMC/SMC busbar supports, suitable for 3 phase 415 V 50 HZ AC supply i/c all connection and interconnections in panel board i/c providing and fixing the following switchgear mounted thereon complete with connections & testing etc. as required. (Note :- The Front area of Panel shall not be less then 1.50 Sq.m. and Depth of Panel not less then 350 mm) 1. All the MCCB’s shall be Ics = 100% Icu. 2. All the MCCB’s shall have O/L+S/C+ E/F( only for Microprocessor base release)
(I) BUS BARS 4 strip aluminium bus bars of minimum of 300 Amps, 36 KA for 1 Sec. capacity with heat shrinkable coloured sleeves and including DMC/SMC bus bars supports at required intervals complete for cross section, size supports at their spacing etc. for with standing fault level of 25 MVA for 1 Sec. The size of bus bar shall be provided considering the current density of aluminium bus bar 1.0 Amp. /Sqmm. (II) INCOMING 200 Amps FP MCCB with Ics= 100% Icu = 36KA having Thermal magnetic releases having extendable rotary handle, Spreader links, neutral link,Aux. trip contact block, digital multi function meter with 3 nos. 250/5 CL-1, 15 VA resin cast metering CT, 6 nos. LED indication lamp for R,Y,B, ON, OFF & TRIP, 4 nos. control MCB and 3 nos. toggle switch with each MCCB = 1 no. (III) OUTGOING (a) 100Amps TP MCCB with Ics= 100% Icu = 25KA having thermal magnatic releases for O/L and S/C protection having extendable rotary handle and Spreader links = 3 No. (b) 63Amps TP MCCB with Ics= 100% Icu = 25KA having thermal magnatic releases for O/L and S/C protection having extendable rotary handle and Spreader links = 3 No. (c) Danger notice plate =1 No.
Supplying, installation, testing and commissioning of Indoor floor mounted modular, sectionalised, compartmentalized, dust & vermin proof, extendable type MV cubicle panel having enclosure protection class IP 42 of suitable size & 350 mm deep of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, i/c mounting base frame consist of MS channel of size 75x75x5 mm, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with 4 nos. electrolytic grade high conductivity Aluminium busbar extensible type, DMC/SMC busbar supports, suitable for 3 phase 415 V 50 HZ AC supply i/c all connection and interconnections in panel board i/c providing and fixing the following switchgear mounted thereon complete with connections & testing etc. as required.(Note :- The Front area of Panel shall not be less then 1.20 Sq.m. and Depth of Panel not less then 350 mm)1. All the MCCB’s shall be Ics = 100% Icu. 2. All the MCCB’s shall have O/L+S/C+ E/F( only for Microprocessor base release)
(I) BUS BARS 4 strip aluminium bus bars of minimum of 200 Amps, 50 KA for 1 Sec. capacity with heat shrinkable coloured sleeves and including DMC/SMC bus bars supports at required intervals complete for cross section, size supports at their spacing etc. for with standing fault level of 25 MVA for 1 Sec. The size of bus bar shall be provided considering the current density of aluminium bus bar 1.0 Amp. /Sqmm. (II) INCOMING 100 Amps FP MCCB with Ics= 100% Icu = 25KA having thermal magnatic releases for O/L and S/C protection having extendable rotary handle, Spreader links, neutral links Aux. trip contact block, digital volt meter with inbuilt VSS, digital ammeter with inbuilt ASS and 1 set 160/5A CL-1 15 VA resin cast metering CT, 6 nos. LED indication lamp for R,Y,B, ON, OFF & TRIP, 4 nos. control MCB and 3 nos. toggle switch with each MCCB = 1 No. (III) OUTGOING a) 63Amps TP MCCB with Ics= 100% Icu = 25KA having thermal magnatic releases for O/L and S/C protection having extendable rotary handle and Spreader links = 5 Nos. b) 63 Amp 10KA C curve DP MCB = 5 Nos. c) Danger notice plate =1 No.
Fabrication, Supplying, installation, testing and commissioning of Outdoor type double door floor mounted modular, sectionalised, compartmentalized, extendable type MV cubicle panel/ feeder pillar with enclosure protection class IP 42 having front surface area minimum 1.20 Sq. Mtr. & 400 mm deep of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with 4 nos. 100 Amp. electrolytic grade high conductivity Aluminium busbar extensible type, DMC/SMC busbar supports, suitable for 3 phase 415 V 50 HZ AC supply i/c providing and fixing the following switchgear mounted thereon complete with panel shall have 02 Nos. common Copper earth bus of size 20 mm x 3.0 mm size at the rear with 2 Nos earth stud (All the MCCBs shall be Ics= 100% Icu)
Incomer 63 Amp. 25 KA 4 Pole thermal magnetic release MCCB with O/L, S/C protaction, Spreader link, Auxiliary contact and Extended Rotatory handle - 1 No. Digital Multifunction LED meter class 1.0, with RS-485 - 1 No. Metering CT's CL-1, 15 VA resin Cast-63/5A-3 Nos. LED Indication for R,Y,B and ON, OFF- 5 Nos. 2A control SP MCB 10KA - 4 Nos. BUS BAR 4 strip aluminium bus bars of minimum of 100 Amps, 50 KA for 1 Sec. capacity with heat shrinkable coloured sleeves and including DMC/SMC bus bars supports at required intervals complete for cross section, size supports at their spacing etc. for with standing fault level of 25 MVA for 1 Sec. The size of bus bar shall be provided considering the current density of aluminium bus bar 1.0 Amp. /Sqmm. Outgoing DOL starter suitable for upto 10.0 HP pump (TP MCB rating rating upto 40 A,10 KA) complete with Power contactor TP AC-3 duty, Motor protection having inbuilt over load, earth fault, locked rotor and single phasing protection feature complete with all accessories and internal wiring with minimum 2.5 Sqmm PVC insulated copper conductor wire, timers and relays as required, push buttons for start/stop in anual mode, LED indication lamps, Control MCB etc, Ameter, voltmeter. = 3 Nos. Providing and Fixing of MS Base channel of size 50mm x 50mm x 5 mm thick Danger Notice plate of size 200 mm x 150 mm x 2 mm thick - 1 No. 32 A TP MCB 10KA- 2 Nos., 32 A DP MCB 10KA- 2 Nos. All Control wiring shall be done with 2.5 sqmm FRLS Copper wire.
Fabrication, Supplying, installation, testing and commissioning of Outdoor type double door floor mounted modular, sectionalised, compartmentalized, extendable type MV cubicle panel having front surface area minimum 1.0 Sq. Mtr. & 300 mm deep of suitable size with enclosure protection class IP 42 fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with 4 nos. 100 Amp. electrolytic grade high conductivity Aluminium busbar extensible type, DMC/SMC busbar supports, suitable for 3 phase 415 V 50 HZ AC supply i/c providing and fixing the following switchgear mounted thereon complete with panel shall have 02 Nos. common Copper earth bus 20 mm x 3.0 mm size at the rear with 2 Nos earth stud (All the MCCBs shall be Ics= 100% Icu)
Incomer 63 Amp. 25 KA 4 Pole thermal magnetic release MCCB with O/L, S/C protaction, Spreader link, Auxiliary contact and Extended Rotatory handle - 1 No." Digital Multifunction LED meter class 1.0, with RS-485 - 1 No. Metering CT's CL-1, 15 VA resin Cast- 63/5A-3 Nos. LED Indication for R,Y,B and ON, OFF- 5 Nos. 2A Control SP MCB 10 KA- 4 Nos. 63 A Power contactor FP AC1 Duty - 1Nos. Analog Time Switch Daily -1 No" Outgoing Providing and Fixing of MS Base channel of size 75mm x 75mm x 5 mm thick Danger Notice plate of size 200 mm x 150 mm x 2 mm thick - 1 No. 32 A TP MCB 10KA- 2 Nos., 32 A DP MCB 10KA- 3 Nos. All Control wiring shall be done with 2.5 sqmm FRLS Copper wire.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying Installation Testing and Commissioning of 8 MP IP IR Dome Camera having following specifications and features etc :- 1) Type of Camera: Dome Camera 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 meter for colour view in night. 9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP @25/30 fps & D1@25/30 fps; 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Water Marking 17) Onboard Storage: Camera should support built-in Micro
SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device, 19) Edge Analytics: Tripwire, Intrusion, Motion Detection 20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port 22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) System Capability: ONVIF 25) VMS: Camera shall support open source VMS 26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 27) Ethernet: 1 RJ 45 10/100 Ethernet port 28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE 30) Enclosure: IP67 weather proof, IK10 31) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
8 MP (3840 × 2160) or better IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal otorized lens Dome Camera.
Supplying Installation Testing and Commissioning of 8 MP IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Type of Camera: Outdoor Bullet Camera 2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt Smart IR LED's with effective distance upto 50 Mtrs integrated IR and 30 meter for colour view in night 9) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP @25/30 fps & D1@25/30 fps; 14)
Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Digital Water Marking 17) Onboard Storage; Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device, 19) Edge Analytics: Tripwire, Intrusion, Motion Detection 20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port 22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) User Access: Minimum 08 Users 25) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation). 26) VMS: Camera shall support open source VMS 27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 28) Ethernet: 1 RJ 45 10/100 Ethernet port 29) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 30) Power Requirement: 12VDC/24VDC/ PoE (802.3af)/ePoE 31) Enclosure: IP67 weather proof, IK10 32) Operating Condition: Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 33) IR life: 40000 hours or higher 34) Video Bit rate: 32 KBPS - 8 MBPS or better 35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
8 MP (3840 × 2160) or better IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera.
Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video ompressions : H.265 or better, H.264, MJPEG 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions.
4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0) 8) Video Output Ports: 2x HDMI and 2 VGA 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.
18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF 22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection
32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C I Pv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
15U Rack
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Copper Patch Cords of length 1m (3ft)
Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.
55 inch or larger
Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
10TB (Terabytes)
Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubrication Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level
Alternator Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all
standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. (F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/ connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.
17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) .
The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 6.4, Capacity > 40 and <70 ISEER 6.5, Capacity > 70 ISEER 6.6 for ECSBC+ Building)
Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor)
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2mm
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2mm
Providing and fixing of rigid UPVC 6kg/Sq.Cm condensed water drainage pipe from Indoor unit to nearest disposal point (in toilet/ outside rain water harvesting system or as approved by architect/ consultant / Engineer-in-charge) of following sizes complete with fittings, supports as per specifications duly insulated with 6 mm thick closed cell / cross linked / Elastomeric nitrile rubber / polythene foam insulation etc. as required at site.
25 mm dia
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
50 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.37 MB
132UpgradationRenovationRehabilitationJJBIJJBIIISewaKutirComplex.pdf
Tender Documents • 2.36 MB
BOQ_381805.xls
BOQ • 0.60 MB
Download all tender documents and submit your bid